• Title/Summary/Keyword: Aeration efficiency

Search Result 228, Processing Time 0.033 seconds

A Study on the improvement of treatment efficiency in a conventional sewage treatment plant (기존 하수처리장에서의 처리 효율개선에 관한 연구)

  • 안철우;박진식;문추연
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.50-56
    • /
    • 2000
  • In this study, sewage were treated with operating Two-step Aeration System and conventional activated sludge process together in a condition. At the same HRT 8hr of Two-step Aeration System and Activated Sludge Process, BOD treatment efficiency of 1st sedimentation basin effluent 36.9% by Two-step Aeration system was 12.3% higher than 24.65 by Activated Sludge Process and the COD treatment efficiency 39.8% by two-step Aeration System was 11.6.3% higher than 28.2% by Activated Sludge Process. BOD and COD treatment efficiencies of 2nd sedimentation basin effluent were 88.1% and 85.6% Two-step Aeration System and were 83.8% and 82.3% Activated Sludge Process. In the first treatment, as BOD was relatively removed a lot, F/M ratio 0.17, $0.21{\cdot}BOD/kg{\cdot}MLSS.d$ was maintained by Activated Sludge Process. Therefore it was proved that organic matter treatment efficiency by Two-step Aeration System os Higher than by Activated Sludge Process in a aeration time 8hr. $NH_4^{+}-N$ treatment efficiencies were 55.5% by Two-step Aeration System and 39.75 by Activated sludge Process. $NO_3^{-}-N$ concentration in 2nd. sedimentation basin effluent were 3.33% by Two-step Aeration System and 2.36% by Activated Sludge Process. From this result, Two-step Aeration System was proved more advantageous treatment process for nitrification than Activated Sludge Process. The fluctuation range of BOD, COD and SS concentration in 2nd sedimentation basin effluent $16~33mg/{\ell}$, $15~23mg/{\ell}$ and $14~22mg/{\ell}$ by Two-step Aeration System was smaller than $16~57mg/{\ell}$, $15~25mg/{\ell}$ by Activated sludge Process. Overall the fluctuation range in 2nd sediment basin effluent by was smaller than by Activated Sludge Process. As a result, it is possible for this Two-step Aeration with no facility investment and a little of operation condition change in a conventional sewage treatment plant to get stability and nitrification of treatment water quality.

  • PDF

Nitrogen and Phosphorus Removal Characteristics by the Variation of Aeration Time in SBR (SBR에서 포기기간 변경에 따른 질소.인 제거 특성)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.2
    • /
    • pp.116-123
    • /
    • 2009
  • Laboratory scale experiments were conducted to investigate the removal characteristics of nitrogen and phosphorus by the variation of aeration time in four sequencing batch reactors (SBRs). In R1 which has the shortest aeration time as 1 h, MLVSS concentration in reactor decreased by the wash-out of biomass because of the poor sedimentation. The TOC removal efficiencies were almost similar in 3 reactors except R1. At the low aeration time as 1 h, the nitrification was severely inhibited by the deficiency of oxygen. ${NH_4}^+$-N removal efficiency was decreased by the decrease of aeration time. At the aeration time over 2 h, the phosphorus removal efficiency was not affected by the variation of aeration time. The nitrification was inhibited but the phosphorus release and uptake was not inhibited by the decrease of low aeration time. Therefore, we can see that the phosphorus removal microorganisms are superior to nitrification microorganisms in oxygen utilization.

Evaluation of Operation Characteristics with Aeration Time in Intermittent Aeration Membrane Bioreactor (간헐포기 MBR공정에서 포기시간에 따른 운전특성 평가)

  • Lim, Bong-Su;Choi, Bong-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.353-359
    • /
    • 2005
  • This study was conducted to evaluate the operation characteristics with aeration time in intermittent aeration membrane bioreactor. The BOD removal efficiency rate of this process was over than 97% regardless of aeration on/off time. To get over than 82% of nitrogen removal efficiency rate, aeration off time needs more than 70 minutes in reactor. Specific denitrfication rate was 2.68 mg $NO_3-N/gMv/hr$ in 40/80 min aeration on/off time, was 2.6 times more than 60/60 min, and 1.4 times more than 50/70 min in 6,300 mg/L of MLSS concentration. Specific nitrification rate was 1.96 mg $NH_4-N/gMv/hr$ in 50/70 min, was 1.4 times more than 40/80 min, but it was effectded little upon nitrification. Microbial activity was effected little according to aeration on/off time, oxygen demend was reduced according to aeration off time increased and microbial concentration increased. The longer aeration off time become, the higher Extraceller Pollymeric Substance (EPS), 50/70 min and 40/80 min in aeration on/off time was increased 1.6 times and 2.7 times, respectively more than 60/60 min because of increase of operation pressure.

Evaluation of the Oxygen Transfer Parameters (α and F) of a Coarse Bubble Aeration System by Off-gas Column Test (Off-gas Column Test를 이용한 하수처리장 심층포기시스템의 산소전달 매개변수(α와 F)의 산정)

  • Kim, Chul Woong;Lee, Se Ho;Shin, Dong Rok;Lee, Ji Yong;Park, Jae Han;Ahn, Yoon Hee;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1119-1122
    • /
    • 2006
  • Aeration by using diffusers usually requires approximately 50~90% of the total electricity needed to operate WWTP (WasteWater Treatment Plant)s. Accurate evaluation of the oxygen transfer efficiency for an aeration system, and recommendation of a better alternative may help saving WWTP operational costs. Appropriate techniques and methods to achieve this purpose have not been introduced in Korea. In this study, in-process analysis was performed for a coarse bubble aeration system by the off-gas method to evaluate its applicability in Korea. To accomplish this analysis, an off-gas test, unsteady-state clean water test and steady-state off-gas column test was conducted and comparisons to other aeration systems were made. The ${\alpha}$ and the F estimated from the results of the unsteady-state clean water test and the steady-state off-gas column test were 0.61 and 0.90 respectively in a coarse bubble aeration system. The comparison of P.E tube diffusers laid out single spiral roll and ceramic dome diffusers laid out full floor coverage showed that the oxygen transfer efficiency of the coarse bubble aeration system was less than or similar to other aeration systems. But, airflow rates per unit area were 4~5 times greater than other aeration systems. In regards to the oxygen transfer efficiency for airflow rates per unit area, a retrofit to higher efficiency diffusers was urgently needed. This study showed proved that off-gas methods can apply to evaluate diffuser performances to estimate operating factors and to compare other aeration systems in Korea.

Temperature Effect on the Nutrient Removal in the Combined Biological Nutrient Removal System (CBNR) with Anaerobic-Intermittent Aerobic-Modified Oxic Reactors (혐기조-간헐포기조-개량조로 구성된 영양소 제거 공정에서 온도의 영향)

  • Kang, Young-Hee;Han, Gee-Bong
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.639-647
    • /
    • 2006
  • The temperature effect at $20^{\circ}$ and $10^{\circ}$ on the nutrient removal efficiency was evaluated in the combined biological nutrient removal system (CBNR) with anaerobic-intermittent aerobic-oxic reactors. The test was conducted under the conditions of various ratios of intermittent aeration time and distribution of influent raw water to CBNR. The removal efficiencies of organics, nitrogen and phosphorus were a little bit better at $20^{\circ}$ than at $10^{\circ}$. However the large difference of temperature effect on the nutrient removal efficiency between $20^{\circ}$ and $10^{\circ}$ was not appeared because of highly sustained MLSS concentrations in the reactors and controlled intermittent aeration time. In the removal of phosphorus, Mode III (50/70 min in aeration on/off time, 3 times of intermittent aeration) showed more effective compared with short aeration time of Mode IV. In case of N, P removal, the denitrification rate was lower in Mode A with splitted inflow into anaerobic and intermittent aeration basins than in Mode B with sole inflow into anaerobic basin.

Effects of Artificial Filaments Equipped in the Aeration Tank of Aerobic Fermentation System on the Removal Efficiency of Nitrogen of Swine Wastewater Containing High Nitrogen (담체설치가 고질소함유 양돈폐수의 호기발효에 미치는 영향)

  • 손경호;이상락;안정제;권윤정;정태영
    • Journal of Animal Environmental Science
    • /
    • v.6 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • This study was conducted to investigate the effects of artificial filaments equipped in the aeration tank of aerobic·fermentation system on the removal efficiency of swine wastes which were fermented an aerobically and thus containing high nitrogen. Two aerobic fermentation system each consist4s of 4 tanks ; storage tank, 1st and 2nd aeration tank and settling tank were run before and one or three weeks after equipment of artificial filament in the aeration tanks. Total solids concentration tended to increase by aerobic fermentation in all running periods. However, decreased(P<0.05) total nitrogen concentration was shown three weeks after the equipment of artificial filament. Ammonia nitrogen concentration also largely decreased(p<0.05) in both running periods of one and three weeks after equipment of artificial filaments. These results suggest that the artificial filaments may improve the removal efficiency of nitrogen in swine wastewater containing high nitrogen during aerobic fermentation.

  • PDF

Effect of Aeration Intensity on the Treatment Efficiency in Submerged Biofilm Process (침지형 생물막공법에 있어서 포기강도가 처리효율에 미치는 영향)

  • 박종웅
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.1
    • /
    • pp.89-96
    • /
    • 1989
  • An aerated submerged biofilm reactor is the reactor in which influent organic substrates are aerobically oxidized by suspended biomass and attached biomass of biofilm grown on the surface of submerged media. The objective of this study was to investigate the effect of aeration intensity on microbial characteristics and treatment efficiency in submerged biofilm process. In the organic loading rate (4.3kg BOD/$m^{3} \cdot day$), biofilm thickness (420-780$\mu$m) and attached biomass(1.79-2.94mg/cm$^{2}$) increased as the aeration intensity increased (2-8m$^{3}$ air/$m^{2} \cdot hr$), but biofilm density decreased (42.25-37.69mg/cm$^{3}$). The minimum aeration intensity for prevention of deposited biomass was 2m$^{3}$ air/$m^{2} \cdot hr$. The minimum dissolved oxygen of 2.5mg/l had to be maintained for improved efficiency.

  • PDF

Aeration Factor Used To Design The Container Type of Biopile Systems for Small-Scale Petroleum-Contaminated Soil Projects

  • Jung, Hyun-Gyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.2
    • /
    • pp.316-319
    • /
    • 2011
  • Biopiles which offer the potential for cost-effective treatment of contaminated soils are above-ground, engineered systems that use oxygen to stimulate the growth and reproduction of aerobic bacteria for degradation of the petroleum constituents adsorbed to soil in excavated soils. This technology involves heaping contaminated soils into piles and stimulating aerobic microbial activity within the soils through the aeration and/or addition of minerals, nutrients, and moisture. Inside the biopile, microbially mediated reactions by blowing or extracting air through the pipes can enhance degradation of the organic contaminants. The influence of a aeration system on the biopile performance was investigated. Air pressure made to compare the efficiency of suction in the pipes showed that there were slightly significant difference between the two piles in the total amount of TPH biodegradation. The normalised degradation rate was, however, considerably higher in the aeration system than in the normal system without aeration, suggesting that the vertical venting method may have improved the efficiency of the biological reactions in the pile.

A Study on the Treatment of Paper Mill Wastewater with the Addition of High Thermal Microbial Inoculants (고온성 종균제를 이용한 제지폐수 처리)

  • 이성호;임택준;조준형
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.2
    • /
    • pp.54-60
    • /
    • 2002
  • The Wastewater of toilet paper mill recycling recovered milk carton was used as a raw material for this study. According to the actual mill conditions, hydraulic retention time was adjusted to 12 hours and F/M (Food/Micro-organism) ratio was adjusted to 0.23. Temperature of aeration basin was varied from 2$0^{\circ}C$ to 5$0^{\circ}C$. The change of Micro-organisms and removal efficiency of pollutant were investigated at the varied temperature of basin. Aeration basin using high thermal microbial inoculants showed more removal efficiency of SS, COD than aeration basin using conventional microbial inoculants at high temperature. Floc consolidation of aeration basin using high thermal microbial inoculants added sludge was better than that of sludge from aeration basin using conventional microbial inoculants.

Effects of the Variation of Aeration Time in Sequencing Batch Reactor (SBR) (1) - Nutrient Removal (Sequencing Batch Reactor (SBR)에서 포기시간 변경에 따른 영향 (1) - 영양염류 제거)

  • Jeong, No-Sung;Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.35-47
    • /
    • 2011
  • The effect of the variation of aeration time on the removal of organics, nitrogen and phosphorus using synthetic wastewater was investigated in sequencing batch reactors (SBRs) which included DNPAOs and DNGAOs. The cycling times in four SBRs were adjusted to 12 hours and then included different aerobic times as 1 hr, 2.5 hr, 4 hr and 5.5 hr, respectively. Four SBR systems have been operated and investigated for over 40 days. Average TOC removal efficiencies were about 71 % in all SBRs. The $NH_4^+$-N removal efficiency was increased as the increase of aeration time. After changing aeration time, the total nitrogen removal efficiencies of SBRs were shown as 35 %, 85 %, 75 % and 65 %, respectively. Higher phosphorus release and uptake were occurred as the decrease of the aeration time. After all, the overall phosphorus removal efficiency decreased and the deterioration of phosphorus removal was occurred when aeration time was over 4 hr. Denitrification in aerobic conditions was observed, which showed the presence of DNPAOs and DNGAOs. In batch experiments, PAOs were shown as the most important microorganisms for the phosphorus removal in this experiment, and the role of DNGAOs was higher than that of DNAPOs for the nitrogen removal.