• 제목/요약/키워드: Advanced wastewater treatment plant

검색결과 107건 처리시간 0.026초

고도처리 하수처리장 운전조건의 통계분석 (Statistical Analysis of Operating Parameters on Advanced Wastewater Treatment Plant)

  • 이찬형;문경숙
    • 한국환경과학회지
    • /
    • 제14권2호
    • /
    • pp.251-258
    • /
    • 2005
  • Statistical analysis between operating parameters and effluent quality on advanced wastewater treatment plant was performed. Through factor analysis four factors derived varimax rotation were selected each plant. Four components explained $80\%,\;82\%$ of the total variance of the process, respectively. The components on MLE plant were identified in the following order: 1) HRT increase and BOD load decrease by influent decrease, 2) Biomass, 3) SVI increase by internal return increase, 4) Microbial diversity by SRT increase. On $A_2O$ plant, we defined them as follows: factor 1, high MLSS by return rate increase, HRT increase by influent decrease; factor 2, biomass; factor 3, BOD of influent; factor 4 was relate to DO.

하수처리장 연계처리를 위한 가축분뇨 최적 처리공정 선정에 관한 연구 (Determination of Optimal Livestock Wastewater Treatment Process for Linked Treatment in Sewage Treatment Plant)

  • 김충곤;신현곤
    • 유기물자원화
    • /
    • 제20권3호
    • /
    • pp.52-59
    • /
    • 2012
  • 처리공정별 연계처리수질을 검토한 결과 생물학적처리만 거친 생물반응조 처리수의 경우 연계부하율이 $COD_{Mn}$의 경우 1.67%(설계수질 기준), 2.59%(운영수질 기준), T-P의 경우 3.69%(설계수질 기준), 7.67%(운영수질 기준)로 다소 높게 나타났으나 하수처리장 운영에 미치는 영향은 거의 없을 것으로 판단된다. 또한, 고도처리공정인 산화부상분리 처리수 및 생물여과 처리수의 경우 연계부하율은 1% 내외로 고도처리설비 설치 시 과대 설비설치의 우려가 있다. 따라서 S하수처리장의 경제성 및 안정적인 운영을 고려할 경우 생물학적처리인 생물반응조를 거친 처리수를 연계하는 것이 바람직할 것으로 판단된다.

고도처리 효율 향상을 위한 통계적 접근 (Improvement of Operating Efficiency on Advanced Wastewater Plant Using Statistical Approach)

  • 문경숙;민경섭;김승민;이찬형
    • 한국환경과학회지
    • /
    • 제17권4호
    • /
    • pp.405-412
    • /
    • 2008
  • Statistical analysis technique was applied to operating parameters and removal efficiency data sets obtained from advanced wastewater treatment plant during 1 year. Through factor analysis three factors derived varimax rotation were selected each plant. Three components explained 96%, 87% of the total variance of the process, respectively. The components on $A_2O$ Plant were identified in the following order : 1) Shortening the SRT during high-flow period, 2) Keeping biomass high on winter 3) factor was related to DO. On DNR plant, we defined them as follows: factor 1, Prolonged the SRT during high-flow period; factor 2 was related to sludge return; factor 3, Influent BOD during low-DO period. This technique was believed to assist operators in identifying priorities to improve operation efficiency.

파일럿 플랜트 규모에서 일체형 침전부상공정 (SeDAF)의 설계인자 및 운전특성에 대한 실증적 평가 (Empirical evaluation for design parameters and operating characteristics of the integrated sedimentation and dissolved air flotation (SeDAF) process at the pilot-scale plant)

  • 장여주;정진홍;임현만;김원재
    • 상하수도학회지
    • /
    • 제35권1호
    • /
    • pp.1-14
    • /
    • 2021
  • Eutrophication and algal blooms can lead to increase of taste and odor compounds and health problems by cyanobacterial toxins. To cope with these eco-social issues, Ministry of Environment in Korea has been reinforcing the effluent standards of wastewater treatment facilities. As a result, various advanced phosphorus removal processes have been adopted in each wastewater treatment plant nation-widely. However, a lot of existing advanced wastewater treatment processes have been facing the problems of expensive cost in operation and excessive sludge production caused by high dosage of coagulant. In this study, the sedimentation and dissolved air flotation (SeDAF) process integrated with sedimentation and flotation has been developed for enhanced phosphorus removal in wastewater treatment facilities. Design and operating parameters of the SeDAF process with the capacity of 100 ㎥/d were determined, and a demonstration plant has been installed and operated at I wastewater treatment facility (located in Gyeonggi-do) for the verification of field applicability. Several empirical evaluations for the SeDAF process were performed at demonstration-plant scale, and the results showed clearly that T-P and turbidity values of treated water were to satisfy the highest effluent standards below 0.2 mg/L and 2.0 NTU stably for all of operation cases.

가정하수를 cosubstrate로서 사용한 하수-염색폐수-공장폐수의 합병 고도처리 pilot plant 연구 (Pilot Study on the Advanced Treatment of Combined Wastewater with Sewage as a Cosubstrate)

  • 김미경;서상준;류덕희;정동일
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.227-234
    • /
    • 2009
  • In this research, a retrofitting process, which consists of a pretreatment system (coagulation) for dye wastewater combined with a biological nutrient system (MLE process using media), for a sewage treatment plant that has to treat dye wastewater efficiently with domestic wastewater were developed and a pilot plant was operated for verifying adoptability and performance of the developed advanced process for dye wastewater. From the results of the pilot plant operation, BOD 52.9%, $COD_{Cr}$ 55.9%, and color 71.3% were removed in pretreatment of coagulation process and the biodegradability of dye wastewater was improved to $0.32{\sim}0.59BOD/COD_{Cr}$ of the coagulated wastewater from $0.29{\sim}0.43BOD/COD_{Cr}$ of the raw dye wastewater. The final effluent concentrations were BOD of 8 mg/L, $COD_{Cr}$ of 43 mg/L, $COD_{Mn}$ of 18 mg/L, T-N of 8 mg/L, and T-P of 1.3 mg/L, respectively. Color was removed from 1655 to 468 unit by coagulation and then to 123 unit by MLE process. The HPLC analysis of aromatic amines in wastewater showed that decolorization was achieved by cometabolism while aromatic amines were produced by cleavage of azo bonds under anaerobic conditions and these products were removed in an aerobic tank subsequently. Nitrification rates of attached and suspended microorganisms were evaluated comparatively and the acclimating conditions of bacteria on media were validated by the scanning electron microscope.

고급산화공정을 이용한 염료폐수의 처리기술 연구 (A Study on the Dye Wastewater Treatment by Advanced Oxidation Process)

  • 강태희;오병수;박세준;강민구;김종성;강준원
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.267-273
    • /
    • 2005
  • Dye wastewater generally contains strong color and non-biodegradable materials. Therefore, the conventional wastewater treatment plant can hardly meet the regulation of wastewater effluent water. In this study, a pilot plant of the conventional process followed by advanced oxidation process (AOP), was set up to treat the dying wastewater. The treatment efficiencies on the various candidate processes, such as ozone alone, UV alone, ozone/UV, $ozone/H_2O_2$, $H_2O_2/UV$ and $ozone/UV/H_2O_2$, were investigated in the various ozone and $H_2O_2$ doses. As the results, the $ozone/H_2O_2$ process, among the tested processes, showed the highest efficiency for removing color and $COD_{Cr}$. For color removal, the ozone alone process was enough without combining UV or $H_2O_2$. No significantly enhanced efficiency for removing color and $COD_{Cr}$ by UV irradiation was observed because of the very low transmittance of UV light in dye wastewater.

가죽, 모피 가공 및 제조업 폐수처리시설의 경제성 평가 (Economical Assessment of Wastewater Treatment Facilities in Leather Tanning and Finishing Industry)

  • 김재훈;양형재;권오상;이성종
    • 한국물환경학회지
    • /
    • 제23권1호
    • /
    • pp.131-137
    • /
    • 2007
  • Industrial wastewater management guideline and evaluation model of Best Available Technologies for the leather tanning and finishing industry was developed as an economical evaluation model using evaluation of BAT including economical evaluation combined with cost analysis model and cost annualization model in considering of economical factors and non-water environmental factors. It was verified that approximately 10% will be increased annually to modify conventional treatment process ($3,700m^3/d$) of J leather wastewater treatment plant to advanced process of K leather wastewater treatment plant.

전기응집을 이용한 2차 유출수의 질소.인 제거 공정 연구 (Removal of nitrogen and phosphorus of the secondary effluent by electro-coagulation)

  • 한송희;장인성
    • 상하수도학회지
    • /
    • 제26권4호
    • /
    • pp.579-589
    • /
    • 2012
  • To reduce extensive energy costs of the internal recycling for the purpose of denitrification in the advanced wastewater treatment, a post-treatment process using an electro-coagulation to treat nitrate in the secondary effluents is evaluated in this study. Removals of phosphorus and organics in the secondary effluents by the electro-coagulation were also evaluated to propose an alternative advanced wastewatert treatment process. A series of experiments of the electro-coagulation were carried out with the following 4 different samples: synthetic solution containing nitrate only, synthetic solution containing nitrate as well as phosphorus, secondary effluents from activated sludge cultivated in laboratory, and secondary effluents from real wastewater treatment plants. Removals of nitrate and phosphorus in the synthetic solution were 30 and 97 % respectively, which verified the feasibility of the process. Removals of nitrate, phosphorus and COD in the secondary effluents from the cultivated sludge in laboratory were 49, 90 and 19 % respectively. Removal efficiency of the total nitrogen, nitrrate, phosphorus and COD in the secondary effluent from real wastewater treatment plant were 50, 61, 98 and 80 % respectively. The removal of the total nitrogen was less than the nitrate as expected, which is due to the formation of ammonia nitrogen in the cathode. But the proposed scheme could be an energy saving and alternative process for the advanced wastewater treatment if further studies for the process optimization are carried out.

하수처리장의 고도처리 upgrading 설계와 공정 최적화를 위한 다변량 통계분석 (Design of a Wastewater Treatment Plant Upgrading to Advanced Nutrient Removal Treatment Using Modeling Methodology and Multivariate Statistical Analysis for Process Optimization)

  • 김민정;김민한;김용수;유창규
    • Korean Chemical Engineering Research
    • /
    • 제48권5호
    • /
    • pp.589-597
    • /
    • 2010
  • 하수처리 시스템에서의 생물학적 영양염류 기준이 강화됨에 따라, 표준활성슬러지공법으로 운전 중인 하수처리장의 고도처리 공법으로의 개보수 필요성이 증가하고 있다. 그러나 실제 하수처리 시스템에서의 다양한 유입조건 및 운전조건의 복잡한 반응 구성으로 인해 실험을 통하여 개보수된 고도처리공법의 최적조건을 찾는 것은 쉽지 않은 일이며, 이는 많은 시간과 비용을 소모하여 비효율적이다. 따라서 본 연구에서는 활성슬러지공정모델(ASMs)을 기반으로 한 하수처리장의 모델링 및 시뮬레이션 기법을 통하여 하수처리장의 고도처리공법으로의 upgrading 설계를 수행하며, 이를 통계적이며 체계적으로 접근하기 위해 반응표면분석법(Response surface method)을 통한 고도처리공법의 설계 최적화를 수행하였다. 또한 실규모 하수처리장에서의 운전 최적화를 위해서는 하수처리의 동력학적 매개변수에 대한 정확한 분석이 수행되어야 한다. 본 연구에서는 다변량 통계분석 기법인 부분최소승자법(PLS)을 통하여 하수처리 시스템의 동력학적 매개변수 간의 상관관계를 파악하며, 고도처리공법 하수처리장의 운전 결과에 가장 큰 영향을 미치는 매개변수를 도출하였다. 본 연구를 통해 하수처리장의 고도처리공법 upgrading 설계 및 운전 최적화를 위한 방법론을 제시하였으며, 이를 통하여 설계시간 및 경비 절감 등 고도처리공법으로의 고효율적인 개보수가 가능할 것으로 예상된다.

침지식 중공사막을 결합한 Dynamic state 하수고도처리공정(KSMBR process)의 개발 및 현장적용평가 (Development and Field Application of the Advanced Wastewater Treatment process (KSMBR) by Hollow Fiber Submerged Membrane)

  • 김지연;서인석;김홍석;김연권;김병군;최창규;안효원;서완석;장문석
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.358-363
    • /
    • 2006
  • KSMBR process is dynamic state advanced wastewater treatment applied with Trisectional Aeration (TSA) mode combined with membrane. TSA was remodeled conventional intermittent aeration which was operated nonaeration-aeration. TSA operates nonaeration ($N_1$) - aeration (A) - nonaeration ($N_2$) in Trisectional Aeration Reactor (TAR). Organics of influent could be nearly consumed to denitrification without influence by remained DO in TAR and it could be operated about sludge return ratio of 1Q (influent base). The purpose of this study was to apply KSMBR to the full-scale plant and to evaluate efficiency of nitrogen and phosphorus removal and TSA operation. The result of this study, average CODcr/T-N and CODcr/T-P ratio were 7.8 and 59.6, respectively. BOD, TCODcr, SS, T-N, T-P, E-coli removal efficiency were 98.4, 95.2, 73.0, 69.6, 99.95 %, respectively. KSMBR obtained high removal efficiencies of C, N and P when it applied full-scale plant.