• Title/Summary/Keyword: Advanced medical device

Search Result 131, Processing Time 0.022 seconds

RFID-based Authentication Protocol for Implantable Medical Device (체내삽입장치에 RFID 기술을 적용한 인증 프로토콜)

  • Jeong, Yoon-Su
    • Journal of Digital Convergence
    • /
    • v.10 no.2
    • /
    • pp.141-146
    • /
    • 2012
  • U-healthcare, which grafted advanced IT technology onto medical technology, is in the limelight because it can provide medical services at anytime and anywhere. U-healthcare system applied RFID technology for Implantable Medical Device (IMD), but patient's biometric information can be easily exposed to third parties. In this article, RFID-based U-healthcare authentication protocol is proposed to prevent illegal usage for personal biometric information exposed to the third patty. The proposed protocol guarantees patients' biometric information integrity as compounding random numbers between administrators and hospital/clinic managers, and uses continuous number SEQ and time stamp T to synchronize IMD/administrators and administrators/hospital managers. Also, to protect user's privacy from the third party, patients' biometric information can be safely guarded by managing patients' security identifiers by administrators.

A Study on the Implementation of WBAN-Based Medical Gateway (WBAN 기반의 의료용 게이트웨이 구현에 관한 연구)

  • Park, Yong-Min
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.6
    • /
    • pp.640-647
    • /
    • 2014
  • The WBAN technology means a short distance wireless network which provides each device's interactive communication by connecting devices inside and outside of body located within 3 meters. It is necessary to develop core technology that the WBAN middleware and application service for WBAN sensor network. A device for gathering patient's biometric information was used zigbex of Hanbaek electronics and we designed the message structure which is collected the biometric information. The gateway design and implementation for the WBAN environment. The embedded system was HBE-empos II of Hanbaek electronics and the WBAN network is implemented to BNC and BN that used for hbe-ubi-zigbex. It was confirmed that the proposed sensor gateway could be used for the interconnection of the proposed system with other networks.

Implementation of the Smart Emergency Medical System (스마트 응급의료 시스템 구현)

  • Park, Hong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.4
    • /
    • pp.646-654
    • /
    • 2011
  • Recently, the task in which the number of people of the emergency medical technician whom it boards the ambulance is unreasonably insufficient and in which the fire fighter one person gets in the ambulance and which transfers the patient comes into question often. When the emergency patient is generated, it has to transfer to the special hospital in which above anything else, the measure which is quick and exact is needed and where there is the medical device which is suitable for particularly, the patient. This paper implementations the emergency medical system by the smart phone. The implemented system monitors the heart beat of the patient the monitoring among the patient transport with the real-time type. It can grasp the medical history information of the patient, and etc. in the past. And the system provides the emergency hospital which the patient requires and the pre-hospital phase provides the environment in which the disposition which is quick and efficient is possible to the emergency patient.

A Study on the Reduction of Organ Motion from Respiration (호흡 운동에 의한 내부 장기의 움직임 감소에 관한 연구)

  • Kim Jae-Gyoun;Lee Dong-Han;Lee Dong-Hoon;Kim Mi-Sook;Cho Chul-Koo;Yoo Seong-Yul;Yang Kwang-Mo;Oh Won-Yong;Ji Young-Hoon
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.179-185
    • /
    • 2004
  • To deal with tumor motion from respiration is one of the important issues for the advanced treatment techniques, such as the intensity modulated radiation therapy (IMRT), the image guided radiation therapy (IGRT), the three dimensional conformal therapy (3D-CRT) and the Cyber Knife. Studies including the active breath control (ABC) and the gated radiation therapy have been reported. Authors have developed the device for reducing the respiration effects and the diaphragm motions with this device were observed to determined the effectiveness of the device. The device consists of four belts to immobilize diaphragm motion and the vacuum cushion. Diaphragm motions without and with device were monitored fluoroscopically. Diaphragm motion ranges were found to be 1.14 ~ 3.14 cm (average 2.14 cm) without the device and 0.72~1.95 cm (average 1.16 cm) with the device. The motion ranges were decreased 20 ~ 68.4% (average 44.9%.) However, the respiration cycle was increased from 4.4 seconds to 3.7 seconds. The CTV-PTV margin could be decreased significantly with the device developed in this study, which may be applied to the treatments of the tumor sited diaphragm region.

  • PDF

History as an Educational Tool: The Educational Turn of the Bakken Museum

  • Shin, Jieun
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.71-85
    • /
    • 2021
  • The history of the Bakken Museum, the Museum of Electricity in Life, is useful to understand the universality and particularity of a local science museum. Beginning with the small collections at the medical device company, the Bakken Museum has expanded its scope and facilities by reidentifying its mission from research institute to educational center. The educational turn of the Bakken Museum has been completed with two remarkable events: the launch of the Summer Institute in 1984 and the construction of the new education facility, New Wing, in 1999. During this change, the museum staff developed unique strategies for public engagement, using the history of science and technology as an educational tool. The shift of the Bakken Museum's mission provides an excellent example of how a local museum could meet the social needs for museums to be educational centers by utilizing its history and collections.

A comparative study to measure the condylar guidance by the radiographic and clinical methods

  • Shreshta, Pragya;Jain, Veena;Bhalla, Ashu;Pruthi, Gunjan
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.153-157
    • /
    • 2012
  • PURPOSE. The study was conducted to compare the radiographic and clinical methods of measuring the horizontal condylar guidance (HCG) values. MATERIALS AND METHODS. The condylar guidance was measured using the radiographic (CT scan) and three clinical methods i.e. the wax protrusive records, Lucia jig record and intraoral central bearing device in 12 patients aged between 20-40 years irrespective of sex. The records were taken and transferred on the semi-adjustable articulator to record the HCG values. The CT scan was taken for 3D reconstruction of the mid facial region. Frankfort horizontal plane (FHP) and a line extending from the superior anterior most point on the glenoid fossa to the most convex point on the apex of articular eminence (AE) was marked on the CT scan. An angle between these two lines was measured on both right and left sides to obtain condylar inclination angle. Three interocclusal protrusive wax and jig records were taken and transferred to the semi adjustable articulator. Three readings were recorded on each side. Similarly the records were taken and transferred to the same articulator using the intra oral central bearing device to record the readings. RESULTS. The statistical analysis showed insignificant differences in the HCG values between the right and left sides [(P=.589 (CT), P=.928 (wax), P=.625 (jig), P=.886 (tracer)]. The clinical methods provided low Pearsons correlation values [(R = 0.423 (wax), R = 0.354 (jig), R = 0.265 (tracer)] for the right as well as the left sides when compared with the CT values. Among the clinical methods, jig and wax method showed strong level of association which is statistically significant while the intra-oral tracer showed weak association with the other two methods. CONCLUSION. The right and left HCG values were almost similar. The CT scan showed higher HCG values than the clinical methods and among the clinical methods, values obtained from all the methods were comparable.

A Review on Clinical Studies on Metabolic Disease Using a Pulse Tonometry Device (맥진기를 활용한 대사증후군 대상 임상연구 고찰)

  • Kim, Ji-hye;Jeon, Young-ju
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.612-623
    • /
    • 2018
  • Objective: The aim of this research was to investigate the current status and limitations of the clinical use of a pulse tonometry device (PTD). Methods: We searched online medical databases, including Oriental Medicine Advanced Searching Integrated System (OASIS), Research Information Sharing Service (RISS), DataBase Periodical Information Academic (DBpia) and PubMed, for clinical studies of metabolic diseases that used PTD. We selected articles on the clinical application of the PTD but excluded duplicate articles, clinical studies without the PTD, and non-clinical studies. In the first screening, 551 articles were selected. Ultimately, we found 10 articles and classified the articles according to the following diseases: hyperlipidemia, diabetes, overweight and obesity, hypertension, and metabolic disease. Results: Of the 10 selected articles, 4 were focused on hypertension. Two articles were focused on overweight or obesity and two articles were focused on the metabolic disease. Conclusions: This study was the first attempt to conduct a systematic review on clinical studies of metabolic disease using the PTD as a primary outcome. We suggest that the standard of pulse wave parameters and operating procedures for the PTD should be further developed. The results of this study are expected to be used as basic information for the planning and progression of clinical studies of metabolic syndrome using PTD.

Comparison between laryngeal tube suction II and laryngeal mask airway in novice users - A manikin study - (초보자에서 후두튜브기도기와 후두마스크기도기의 삽관 비교 - 마네킨 연구 -)

  • Hwang, Ji-Young;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.3
    • /
    • pp.19-28
    • /
    • 2012
  • Purpose : The present study was designed to provide basic data for advanced pre-hospital airway management by comparing the insertion time and success rate between laryngeal tube suction II (LTS II) and laryngeal mask airway (LMA) in a manikin. Methods : A total of 32 participants were novice users to both of devices among paramedic students. After taking the introductory lecture and demonstrations, the participants made an attempt to insert the LTS II and LMA to compare the insertion time and success rate. They marked the easiness of insertion of the score ranged from 1 to 10 score scale and preference of the two devices. Results : The insertion time of the LTS II was significantly shorter than that of the LMA (p =.000). There was no significant difference between LTS II and LMA in the success rate. In the easiness of insertion, the score of LTS II $(8.47{\pm}1.41score)$ was significantly higher than that of LMA $(7.19{\pm}1.98score)$(p =.001). The preference of LTS II (75%) was much higher than that of LMA (25%). Conclusion : The manikin study data showed that the LTS II may be a good alternative airway device for providing and maintaining a patent airway.

A Systematic Review of the Mechanical CPR and Manual CPR on Out-of-Hospital Cardiac Arrest Occurring in High-rise Building

  • ChanHo, Lee;ByounGgil, Yoon;HongBeom, Ahn;YongSeok, Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.434-443
    • /
    • 2022
  • CPR in High-rise building is one of the challenging tasks to 119 paramedics, evacuating patient from the narrow and vertical area. This study was built to compare the method of mechanical CPR and manual CPR is to maximizing on-scene treatment time, and minimizing the hand-off time in cardiac arrest, transporting patient as fast as possible. The electronic data research (Science, Pubmed, Medline, Medline and 55 academic DB interworking) was conducted, and five articles were included by reviewing and excluding through the Covidence program and Review Manager version 5.4(Cochrane Collaboration). OHCA occurring on the higher floor indicates lower in survival. A total studies uniformly reported mechanical CPR is more effective during the high-rise building evacuation, than manual CPR in rate, depth, and hands-on time of chest compression. Use of mechanical CPR device is more suitable in case of High-rise building OHCA to improve the survival rate which is affected by high-quality CPR.

Implementation of a Transcutaneous Power Transmission System for Implantable Medical Devices by Resonant Frequency Tracking Method (주파수 추적 방식에 의한 이식형 의료기기용 무선전력전달 장치 구현)

  • Lim, H.G.;Lee, J.W.;Kim, D.W.;Lee, J.H.;Seong, K.W.;Kim, M.N.;Cho, J.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.401-406
    • /
    • 2010
  • Recently, many implantable medical devices have been developed and manufactured in many countries. In these devices, generally, energy is supplied by a transcutaneous method to avoid the skin penetration due to the power wires. As the most transcutaneous power transmission methods, the electromagnetic coupling between two coils and resonance at a specific frequency has been used widely. However, in case of a transcutaneous power transmitter with a fixed switching frequency to drive an electromagnetic coil, inefficient power transmission and thermal damage by the undesirable current variation may occur, because the electromagnetic coupling state between a primary coil and a secondary coil is very sensitive to skin thickness of each applied position and by person. In order to overcome these defects, a transcutaneous power transmitter of which operating frequency can be automatically tracked into the resonance frequency at each environment has been designed and implemented. Through the results of experiments for different coil surroundings, we have been demonstrated that the implemented transcutaneous power transmitter can track automatically into a varied resonance frequency according to arbitrary skin thickness change.