• 제목/요약/키워드: Advanced Wastewater Treatment

검색결과 377건 처리시간 0.027초

용수 및 폐수 처리를 위한 오존 마이크로버블 적용 (Application of Ozone Microbubbles in the Field of Water and Wastewater Treatment)

  • 남귀웅;정진호
    • Ecology and Resilient Infrastructure
    • /
    • 제3권4호
    • /
    • pp.256-262
    • /
    • 2016
  • 급격한 산업화와 인구증가로 인한 화학물질 사용량의 증가는 기존의 수 처리 방식의 대부분을 차지하는 생물학적 공정의 한계를 불러온다. 이와 같은 문제를 해결하기 위한 방법으로 고급산화공정의 하나인 오존 마이크로버블 기술이 최근 주목을 받고 있다. 본 논문에서는 마이크로버블의 물리학적 및 화학적 특성에 대해 논하고, 다양한 독성 오염물질의 제거를 중심으로 마이크로버블 오존산화공정을 분석하였다. 또한 다른 처리 기술과 결합한 오존 마이크로버블 기술의 용수 및 폐수처리 전망을 논하였다.

Advanced Treatment of Wastewater from Food Waste Disposer in Modified Ludzack-Ettinger Type Membrane Bioreactor

  • Lee, Jae-Woo;Jutidamrongphan, Warangkana;Park, Ki-Young;Moon, Se-Heum;Park, Chul
    • Environmental Engineering Research
    • /
    • 제17권2호
    • /
    • pp.59-63
    • /
    • 2012
  • This paper proposes a modified Ludzack-Ettinger (MLE) type membrane bioreactor (MBR) as a method of treatment for wastewater from food waste disposer. Micro-membrane filtration allows for an extremely low concentration of suspended solids in the effluent. The effluent of the reactor in question is characterized by a relatively high level of non-biodegradable organics, containing a substantial amount of soluble microbial products and biomass. Results obtained in this paper by measurement of membrane fouling are consistent with biomass concentration in the reactor, as opposed to chemical oxygen demand (COD). The MLE process is shown to be effective for the treatment of wastewater with a high COD/N ratio of 20, resulting in are markedly high total nitrogen removal efficiency. Denitrification could be improved at a higher internal recycle ratio. Despite the low concentration of influent phosphorus, the phosphorus concentration of the outflow is seen to be relatively high. This is because outflow phosphorous concentration is related to COD consumption, and the process operates at along solids retention time.

하수처리장 방류수에 존재하는 항생제 내성인자가 하천에 미치는 영향 (Effect of antibiotic resistant factors in effluent of wastewater treatment plant on stream)

  • 장예진;유용재;설우준;차창준;이옥재;채종찬
    • 미생물학회지
    • /
    • 제53권4호
    • /
    • pp.316-319
    • /
    • 2017
  • 하수처리장 방류수와 하천 중의 항생제 내성인자 분포에 대한 상관성을 분석하기 위해 방류수와 상류 하천수, 하류 하천수를 대상으로 항생제 내성유전자와 전파 관련 유전자를 조사하였다. 3개 지점에서 134~183개의 항생제 내성유전자(ARG) 및 전파 관련 유전자(MGE)가 검출되었으며, 1개의 16S rRNA 유전자에 대한 ARG 및 MGE 유전자의 상대적인 총 합이 0.063~0.422 copy로 분석되었다. ARG와 MGE의 수와 존재량은 방류수에서 가장 높게 검출된 반면, 총 세균 수는 가장 적게 검출됨으로서 하수처리 과정에서 사멸된 세균에 포함된 유전자들이 검출된 것으로 판단된다. 또한 MGE의 존재량 양상이 ARG의 존재량과 상관관계를 보임으로서 항생제 내성균들의 내성기작이 자연내성보다는 획득내성일 가능성을 제시하였다.

정수처리공정에서 NOM 거동과 소독부산물 발생특성 (Characterization of NOM Behavior and DBPs Formation in Water Treatment Processes)

  • 김상은;구윤희;유명진;장현성;이수원;한선희
    • 상하수도학회지
    • /
    • 제21권4호
    • /
    • pp.395-407
    • /
    • 2007
  • Disinfection by-products(DBPs) are formed through the reaction between chlorine and natural organic matter(NOM) in water treatment. For reducing the formation of chlorinated DBPs in the drinking water treatment, there is a need to evaluate the behavior of NOM fractions and the occurrence of DBPs for each fraction. Among the six fractions of NOM, the removal of HPOA and HPIN got accomplished through coagulation and sedimentation processes. Advanced water treatment processes were found to be most significant to remove the HPOA and HPON. It was found that HPOA made the most THMFP level than any other fractions and HPIA and HPOA formed higher HAAFP. The fraction of NOM with MW less than 1k Da was 32.5~54.3% in intake raw water. Mostly the organic matter with MW more than 1k Da was removed through coagulation and sedimentation in the drinking water treatment processes. In case of advanced water treatment processes, the organic matter with MW 1k~100k Da decreased by means of ozone oxidation for high molecular weight substances. As the result low molecular organic matter increased. In the BAC and GAC processes, the organic matter with MW less than 100k Da decreased.

하수성분중 비규제대상 유기오염물질의 정성적 특성에 관한 연구 (A Study on the Qualitative Characteristics of Non-Regulated Organic Pollutants in Municipal Wastewater)

  • 신진환;정영도
    • 한국지반환경공학회 논문집
    • /
    • 제8권3호
    • /
    • pp.5-10
    • /
    • 2007
  • 본 연구는 도시하수와 응집, 오존처리, UV와 같은 물리화학적 방법으로 처리된 하수 속에 함유되어 있는 비 규제 유기오염물의 GC/MS를 통한 정성적 분석결과를 나타내었다. 하수 속에 함유된 주요 유기오염물질로는 식품 또는 가정, 공업적 사용으로부터 배출된 물질이 주류를 이루었다. 하수처리장의 생물학적 공정으로부터 몇몇 유기오염물질들의 처리효율은 효과적이었지만 일부의 유기오염물질의 제거는 그리 효과적이지 못하였다. 그러므로 생물학적 방법으로 처리가 효과적이지 못한 물질들의 처리를 위한 고도처리방법의 적용과 가정에서의 이러한 물질이 함유된 제품의 사용에 좀 더 적극적인 조절이 필요 할 것이다. 본 연구에서 얻은 결과는 하천유역에서 이들 오염물질의 특성 및 생태계에 대한 오염물질의 배출 평가에 기여를 할 수 있을 것이다.

  • PDF

공공하수처리시설에서 수질오염물질 유입 및 배출 특성 고찰 - 산업폐수 및 매립지 침출수 연계처리 시설을 중심으로 - (A study on characteristics of influent and effluent pollutants in public sewage treatment works combined with industrial wastewater and landfill leachate)

  • 정동환;조양석;안경희;김은석;김창수;정현미
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.673-682
    • /
    • 2016
  • In this study, we investigated influent and effluent water pollutants in 53 Public Sewage Treatment Works (PSTWs) where industrial wastewater or landfill leachate is combined four times for two years from 2014 to 2015. Also, we analyzed the characteristics of heavy metals and volatile organic carbons at influent and effluent of these PSTWs caused by sewage treatment combined with industrial wastewater or landfill leachate. As a result, six heavy metals such as barium, copper, iron, manganese, nickel and zinc, and four volatile organic carbons (VOCs) including phenols, di(2-)ethylhexyl phthalate (DEHP), formaldehyde and toluene were observed above detection limits in most of PSTWs. Also, it was revealed that six heavy metals such as hexavalent chromium, mercury, cadmium, chromium, nickel and selenium, and four VOCs including 1,1-dichloroethylene, vinyl chloride, naphthalene, and epichlorohydrin were observed more frequently according to precipitation. As a result of reviewing the monitoring data on "Water Quality Monitoring Networks" in lower watersheds of PSTWs, both heavy metals and VOCs were below detection limits, indicating that the effluent water had little influence on the watershed. Nevertheless for the better management of influent and effluent pollutants in PSTWs, it is necessary to establish the advanced management plans for water pollutants in PSTWs, which include a list of priority substances management, monitoring plans, and guidelines for industrial wastewater and landfill leachate combined in PSTWs.

전기화학적 처리에 의한 배추 절임염수 재이용 가능성 평가 (Evaluation of brine reuse on salting of chinese cabbage using electrochemical process)

  • 정희숙;이은실;한성국;한응수
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.541-548
    • /
    • 2014
  • The pickling brine generated from the salting process of kimchi production is difficult to treat biologically due to very high content of salt. When pickling brine is treated and discharged, it cannot satisfy the criteria for effluent water quality in clean areas, while resources such as the salt to be recycled and the industrial water are wasted. However, sterilization by ozone, UV and photocatalyst is expensive installation costs and operating costs when considering the small kimchi manufacturers. Therefore there is a need to develop economical process. The study was conducted on the sterilization efficiency of the pickling brine using electrochemical processing. The electrochemical treatment of organic matters has advantages over conventional methods such as active carbon absorption process, chemical oxidation, and biological treatment because the response speed is faster and it does not require expensive, harmful oxidizing agents. This study were performed to examine the possibility of electrochemical treatment for the efficient processing of pickling brine and evaluated the performance of residual chlorine for the microbial sterilization.

복합미생물제제를 이용한 RCM공법의 선박오수 처리장치 적용에 관한 연구 (Advanced Treatment of Shipboard Sewage by RCM Process with BM)

  • 하신영;김인수
    • 한국항해항만학회지
    • /
    • 제38권5호
    • /
    • pp.451-456
    • /
    • 2014
  • 본 연구에서는 유입수의 변동이 심하고 전문가가 부재한 환경인 선박에서 발생하는 오수의 효과적인 처리를 위하여 RCM공법을 선박오수처리장치에 적용하는 실험실 규모의 실험을 수행하였다. 질소 인의 고도처리 효율과 선박이라는 특수환경과의 접목성을 검토한 결과 RCM공정에 유효미생물을 주입하는 방법은 선박환경에 적합한 것으로 평가되었다. 또한 RCM공정은 활성슬러지 공정에서 배출되는 슬러지는 배출시키지 않고 슬러지액화분해조(SDC)에서 재분해하여 순환함으로써, 최근 해양투기가 금지됨으로 인해 문제가 되고 있는 슬러지의 발생량을 최소한으로 하여 친환경적인 수처리가 가능하다. 복합미생물제제 주입 후 미생물 관찰결과 고도처리에 유리한 미생물종의 출현을 확인하였으며 이들의 상호기작으로 질소 인의 처리에 도움을 주어 처리효율이 높은것이라 판단된다. 유기물 제거효율 실험결과 $BOD_5$, CODcr T-N, T-P의 처리효율이 각각 96, 97, 78, 81.68 %로 나타나 Membrane이나 Filter없이도 강화되어가는 해양오염기준을 충족시킬 수 있는 공정으로 판단된다.

UF/RO 공정을 이용한 정유공장 방류수의 재활용을 위한 고도처리 (Advanced Treatment for Reuse of Oil Refinery Process Wastewater using UF/RO Processes)

  • 이광현
    • 멤브레인
    • /
    • 제10권4호
    • /
    • pp.220-229
    • /
    • 2000
  • 본 연구는 한외여과 중공사형 모듈과 역삼투 나권형 모듈로 구성된 모듈 set 1∼7을 이용하여 모듈 set에 따른 순수 및 2차 처리수의 투과 flux를 고찰하고, 적용압력과 온도변화에 의한 한외여과 막과 역삼투 막의 분리 특성을 고찰하였다. 탁도와 SS는 한외여과 막에서 효율적으로 제거되며 COD, T-N, TDS 등은 역삼투 막에서 우수한 제거효율을 나타내었다. 적용압력과 온도의 증가에 따른 투과 flux는 선형적으로 증가하는 경향을 보였다. 이로부터 한외여과 및 역삼투 막은 정유공장 방류수의 고도처리 및 재활용을 위해 적합한 것으로 나타났다.

  • PDF

수생식물을 이용한 농촌주택 하수의 고도처리 자연정화법 (Advanced Wastewater Treatment-Natural Septic Method of Rural Housing sewage Using an Aquatic Plants)

  • 신방웅;방성택;신민철;이상을
    • 한국농촌건축학회논문집
    • /
    • 제2권1호
    • /
    • pp.89-100
    • /
    • 2000
  • Recently, according to the increase of population and rapid growth of industry, the amount of effluent pollutant has been rising in natural water. In these pollutant, nutrients such as nitrogen and phosphor are told that these evolve the odor, color and eutrophication in rural housing sewage and lake regulary. Many researches have been carried out to remove these nutrients from effluents and will have to be studied more deeply. Especially, because of the sewage of rural housing and livestock, environmental pollution raises serious problem in a rural community. This method is developed to solve the problem environmentally friendly. Using the natural energy(wasteheat, earthheat, solar engery) and the growth properties of aquatic plants are most efficient method to absorb the nutrients and denitrification and phosphor uptake.

  • PDF