• 제목/요약/키워드: Advanced Lamp

검색결과 127건 처리시간 0.026초

저압 전원선의 고조파 분석 (A Study on the Analysis of Harmonics on Low-voltage AC Lines)

  • 이복희;백영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1885-1887
    • /
    • 2004
  • This paper presents the aspect and distribution of voltage and current harmonics being made at low voltage power systems. The voltage and current harmonics in power systems supplying various loads were monitored and analyzed. We have examined the results compared to advanced countries' harmonics control standards. As a result, the current harmonics were significantly greater than the voltage harmonics. In particular, the harmonics of currents flowing through loads with power switching electronics was pronounced. Also, the contents of current harmonics of street lamp circuits was about 30%, and it was decreased to 12.3% with the installation of scries reactor. On the whole, The measured results of voltage and current harmonics exceeds the regulation limits recommended by IEEE std 519-1992.

  • PDF

분기기 고장 시 열차사고방지를 위한 안전시스템 모델링 (A Study on the Safety System Modeling to Prevent Train Accident by Turn-out Failure)

  • 유광균;노성찬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.724-730
    • /
    • 2011
  • A turnout serves to switch train from one line to another. The turnout consists of a Point which is switchs the rail to induce direction, and a Crossing which is cross over two line on the plane surface, and a Lead where is middle section in Point to Crossing. Point machine, consists of a turnout, is important facilities in railway signal, that is safety issue relates in derailment of the train. Recently, train delay and accident frequently occurred because of the turnout include in a point machine trouble of electrical and mechanical. So in order to prevent train accident the research is advanced, install of normal and reverse indication lamp in a point machine, development of adherence detector for sensing the status of adhesion between the stock rails and tongue rails etc. In this paper investigates the problem which is connected with a turnout trouble, include in a point machine, occurrence at the time of train accident, and then proposed to the safety system model in order to prevent the train accident in turnout.

  • PDF

Shear-induced Migration of Brownian Suspension in a Pressure-driven Microchannel Flow

  • Kim Y.W.;Jin S.W.;Kim S.W.;Yoo J.Y.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.84-85
    • /
    • 2004
  • Experimental study was conducted to characterize shear-induced lateral migration of $1.0-{\mu}m-diameter$ Brownian particles flowing through a rectangular microchannel which can be used to deliver small amount of liquids, drugs, biological agents and particles in microfluidic devices. Measurements were obtained by using a mercury lamp with a light of 532-nm wavelength, an inverted epi-fluorescence microscope, and a cooled CCD camera to record particle images. Peclet number was used as a parameter to assess the lateral distribution of the particles at a fixed volume fraction of $0.1\%$. It was shown that as Pe increased, particles were moved toward the centerline of the channel, which is in good agreement with previous studies.

  • PDF

Design of Solar Cell Cooling System Using Convection Phenomena

  • Lee, Jae-hyuk
    • International journal of advanced smart convergence
    • /
    • 제9권2호
    • /
    • pp.123-128
    • /
    • 2020
  • We constructed a cooling system for solar cells using convection phenomena and investigated its cooling performance. The cooling system didn't need any driving power or water resources. The convection cooler manufactured with a right-triangle shape of an air duct was attached to the rear of the solar cell to confirm that cooling was performed using convection phenomena. When the ratio of duct width to attachment surface width was 3:7, and the ratio of entrance height and exit height of duct was 5:1, it showed the best cooling performance. Comparative experiments with solar cells without convection cooler showed that cooling effects from 16.5℃ to 20.9℃ occurred after 40 minutes exposed to the 1300W Xenon lamp condition.

DESIGN AND DEVELOPMENT OF THE COMPACT AIRBORNE IMAGING SPECTROMETER SYSTEM

  • Lee, Kwang-Jae;Yong, Sang-Soon;Kim, Yong-Seung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.118-121
    • /
    • 2007
  • In recent years, the hyperspectral instruments with high spatial and high spectral resolution have become an important component of wide variety of earth science applications. The primary mission of the proposed Compact Airborne Imaging Spectrometer System (CAISS) in this study is to acquire and provide full contiguous spectral information with high quality spectral and spatial resolution for advanced applications in the field of remote sensing. The CAISS will also be used as the vicarious calibration equipment for the cross-calibration of satellite image data. The CAISS consists of six physical units: the camera system, the Jig, the GPS/INS, the gyro-stabilized mount, the operating system, and the power inverter and distributor. Additionally, the calibration instruments such as the integrated sphere and spectral lamps are also prepared for the radiometric and spectral calibration of the CAISS. The CAISS will provide high quality calibrated image data that can support evaluation of satellite application products. This paper summarizes the design, development and major characteristic of the CAISS.

  • PDF

양친매성 스쿠아릴리움색소 초박막의 전기적 특성 (Electrical Properties of Amphiphillic Squarylium Dye Ultra Thin Films)

  • 정순욱
    • 한국응용과학기술학회지
    • /
    • 제20권2호
    • /
    • pp.177-181
    • /
    • 2003
  • Ultra-thin films of amphiphillic squarylium dye were prepared on the hydrophillic substrate by Langmuir-Blodgett(LB) technique. In this study, the photoelectric properties of a amphiphillic squarylium dye LB film was investigated. The visible light(${\lambda}$ = 684nm ) of xenon lamp was illuminated on the amphiphillic squarylium dye LB films and light absorptivity and photoconductivity were observed. The photoconductivity was nearly constant regardless of nominal layer number. The photoelectric properties of the amphiphillic squarylium dye LB films with bottom electrode showed better than that top electrode.

일반 광원을 이용한 PIV의 속도 측정 (Velocity Measurement of PIV Using a General Light Source)

  • 이교태
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.559-564
    • /
    • 1999
  • A particle image velocimetry is the representative technique for measuring flow velocities at whole field simultaneously. The present study adopted the PTV method for velocity acquisition in a square enclosure with initially isothermal fluid by using a general lamp-based sheet light source. The enclosure was composed of hot and cold vertical wall and was confined by two horizon-tal adiabatic walls. The drift velocities were measured and the drift was visualized by PTV for a rayleigh number of 5.28{\times}10^8.$ Obtained instant simulataneous velocity vectors show flow pattern and the result of horizontal velocity profile agree well with the numerical result.

  • PDF

New LEDs improve the quality of illumination of full-color holograms recorded with red 660 nm, green 532 nm and blue 440 nm lasers

  • Gentet, Philippe;Gentet, Yves;Joung, Jinbeom;Park, Sungchul;Park, Misoo;Lee, Seunghyun
    • International Journal of Advanced Culture Technology
    • /
    • 제7권4호
    • /
    • pp.274-282
    • /
    • 2019
  • This paper discusses the main requirements in today's full-color holograms illumination and evaluates the last generation of LEDs, the actual best light source to render properly the colors of the holograms and in particular those recorded with red 660 nm, green 532 nm and blue 440 nm lasers. This paper presents also the first prototype of lamp designed especially for this kind of holograms.

저압 전원계통에서 고조파 양상의 분석에 관한 연구 (A Study on the Analysis of Harmonics Aspects on Low-voltage AC Mains)

  • 이복희;백영환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.100-103
    • /
    • 2004
  • This paper presents the aspect and distribution of voltage and current harmonics being made at low voltage power systems. The voltage and current harmonics in power systems supplying various loads were monitored and analyzed. We have examined the results compared to advanced countries' harmonics control standards. As a result, the current harmonics were significantly greater than the voltage harmonics. In particular, the harmonics of currents flowing through loads with power switching electronics was pronounced. Also, the contents of current harmonics of street lamp circuits was about 30%, and it was decreased to 12.3% with the installation of series reactor. On the whole, The measured results of voltage and current harmonics exceeds the regulation limits recommended by IEEE 519-1992.

  • PDF

신경망 적용의 온도장 측정법 개선 방안 (Improvements of Temperature Field Measurement Technique using Neural Network)

  • 도덕희;김동혁;방광현;문지섭;홍성대;장태현;황태규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권2호
    • /
    • pp.209-216
    • /
    • 2005
  • Thermo-chromic Liquid Crystal(TLC) particles were used as temperature sensor for thermal fluid flow. 1K $\times$ 1K CCD color camera and Xenon Lamp(500w) were used for the visualization of a Hele-Shaw cell The characteristic between the reflected colors from the TLC and their corresponding temperature shows strong non-linearity A neural network known as having strong mapping capability for non-linearity is adopted to quantify the temperature field using the image of the flow. Improvements of color-to-temperature mapping was attained by using the local color luminance (Y) and hue (H) information as the inputs for the constructed neural network.