• 제목/요약/키워드: Adsorption Tower

검색결과 27건 처리시간 0.03초

악취처리를 위한 건식 중공 흡착탑에 대한 유동해석 (Flow Analysis of Dry-Type Hollowed Adsorption Tower for Treatment of Deodorization)

  • 조은만;정원훈;김봉환
    • 한국기계가공학회지
    • /
    • 제21권7호
    • /
    • pp.64-70
    • /
    • 2022
  • The aim of this study is to improve the purification efficiency of odor gas by increasing the contact area between an odor gas and adsorbent. To analyze the flow in the adsorption tower, the flow characteristics in the hollow activated carbon-adsorption tower are identified by applying the loss model, which is a porous flow analysis model. The flow characteristics are investigated for pressure loss, velocity distribution, turbulent kinetic energy, and residence time distribution. The results show that the hollow adsorption tower performs better than the solid adsorption tower in terms of pressure loss and performance. The inner diameter of the hollow region inside the adsorption tower is 0.64 m (Di/Do = 0.37). Furthermore, the adsorbent performance is unaffected even when adsorbent stages are installed to replace the adsorbent.

시화반월산업단지 활성탄 공동재생시스템 적용을 위한 활성탄 흡착탑 개선에 따른 환경적 효과분석 (A Study on the Environmental Effects of Improvement of Activated Carbon Adsorption Tower for the Application of Activated Carbon Co-Regenerated System in Sihwa/Banwal Industrial Complex)

  • 최여진;이영우;정구회;김덕현;박승준
    • 청정기술
    • /
    • 제27권2호
    • /
    • pp.160-167
    • /
    • 2021
  • 본 연구에서는 시화반월산업단지에서 보편적으로 사용하고 있는 일반형 활성탄흡착탑과 활성탄 공동재생시스템 적용을 위해 개발된 카트리지형 활성탄흡착탑으로 개선하여 얻게 되는 환경적 효과분석을 고찰하였다. 일반형 활성탄흡착탑 4개소와 카트리지형 활성탄흡착탑 2개소를 선정하여 사용하고 있는 활성탄의 물성특성을 분석하고 환경오염물질의 저감효율을 비교 분석하였다. 그 결과, 카트리지형 활성탄 흡착탑에 사용되는 활성탄은 요오드흡착력 800 mg g-1 이상의 양질의 활성탄으로 확인되었으며 교체주기내에서 양호한 수준으로 활성탄 흡착성능이 유지되는 것으로 확인되었다. 환경오염물질 저검효율 분석결과 카트리지형 활성탄 흡착탑의 경우 THC (Total Hydrocarbon), toluene 및 MEK (Methylethylketone) 성분의 처리효율이 각각 71%, 77% 및 80%로 좋은 처리효율을 보인 것으로 확인되었다. 일반형 활성탄 흡착탑은 처리효율이 매우 낮아 배출오염물질을 처리하는 방지시설로서의 역할을 제대로 하지 못하고 있었다. 일반형 활성탄 흡착탑을 카트리지형 활성탄 흡착탑으로 개선하여 운영 시 배출오염물질을 저감시킬 수 있을 것으로 판단된다.

바이오가스 마이크로 터빈 발전용 전처리시스템 전산유동해석 (Computational Fluid Dynamics Analysis of the Pretreatment System for Livestock BIO-GAS MGT Power Generation)

  • 허광범;박정극;임상규;김재훈
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.260-263
    • /
    • 2008
  • KEPCO(Korea Electric Power Corporation) is performing the nation's first biogas-MGT project as an effort to encourage the utilization of wasted biogas which contains useful CH4. The goals of this project are to develop the Pretreatment system of Livestock bio-gas and set up the biogas-MGT co-generation system. The project will not only utilze flared biogas as precious energy but also improve the economics of the plant a lot. The pretreatment system mainly consists of sulfur removal tower, biogas compressor and many filtering systems. A computational fluid dynamics study in the bio gas sulfur removal tower and sulfur absorption filter was carried out. Understanding of the flow in the sulfur removal tower and sulfur adsorption filter obtained by this study can be used to identify the problems in the sulfur removal tower and to improve the sulfur removal efficiency of the sulfur removal tower. Resistance material modeling is used to simulate the sulfur adsorption filter, and the resistance coefficient was adjusted to reflect the experimental pressure loss value. And the pressure loss change with the flowrate is predicted

  • PDF

활성탄의 기공구조에 따른 아세톤 증기와 톨루엔 증기의 흡착 및 탈착특성 비교 (Comparison of Adsorption and Desorption Characteristics of Acetone Vapor and Toluene Vapor on Activated Carbons According to Pore Structure)

  • 이송우;나영수;안창덕;이민규
    • 한국환경과학회지
    • /
    • 제21권10호
    • /
    • pp.1195-1202
    • /
    • 2012
  • The purpose of this work is to study the adsorption and desorption characteristics of acetone vapor and toluene vapor from adsorption tower in the VOCs recovery device. The six kinds of activated carbon with different pore structures were used and the adsorption and desorption characteristics were compared according to pore structure, desorption temperature, and adsorption method, respectively. Adsorption capacity of acetone vapor and toluene vapor by batch method was higher than that by dynamic method. Especially, activated carbon with medium-sized or large pores had more difference in adsorption capacity according to adsorption methods as a result of gradually condensation of vapors on relatively mesopore and large pores. Activated carbons with relatively large pores and relatively small saturated adsorption capacity had excellent desorption ability.

활성탄 흡착탑의 실용화를 위한 최적 유동특성 선정 및 열처리 조건에 따른 황화수소 포집능 향상 연구 (Investigation of Optimum Condition of Heat Treatment and Flow to Improve H2S Adsorption Capacity for Practical use of an Activated Carbon Tower)

  • 장영희;김봉환;김성수
    • 공업화학
    • /
    • 제32권1호
    • /
    • pp.91-96
    • /
    • 2021
  • 본 연구에서는 다양한 환경 공정에서 사용되는 황화수소 제거용 흡착탑 효율을 향상시키기 위해 유동 분석 및 흡착성능 향상 연구를 수행하였다. 연구를 위해 상업적으로 이용 가능한 다양한 활성탄에 칼륨(potassium, K)을 담지하여 개질 활성탄을 제조하였다. 또한 열처리 여부에 따라 흡착 성능과 열처리 과정에서 변화된 표면 특성 사이의 높은 상관관계를 고찰하고자 하였다. 함침법을 통해 K로 코팅된 활성탄은 57배 이상의 흡착 성능을 확인하였다. 이는 균일한 기공 형성과 탄소 표면의 K의 강한 결합은 황화수소의 화학적 및 물리적 흡수에 기여한다고 판단하였다. 다양한 상용 활성탄의 표면 구조에 대한 SEM 분석은 열처리를 통한 표면 특성의 변형으로 인해 기공 구조가 파괴되어 흡수 성능이 저하되는 것으로 확인하였다. 각 활성탄의 압력 손실 특성은 입자 크기와 모양에서 가장 낮은 압력 손실이 관찰되었다. 따라서 2~4 mesh 크기의 탄소입자 범위와 불규칙한 모양이 흡착탑의 성능을 향상시키고 경제적 효율성을 확보할 수 있다고 제안하였다.

수소 정제 시스템의 건조 타워 열전달 해석을 위한 응용 프로그램 코드 개발 (Development of an Application Program Code for Dryer Tower of Heat Transfer Analysis in Hydrogen Purification System)

  • 권수인;진병석;최경민
    • 한국수소및신에너지학회논문집
    • /
    • 제34권4호
    • /
    • pp.334-341
    • /
    • 2023
  • The purity of hydrogen finally purified in the hydrogen purification process system is greatly influenced by the uniformity of the purification temperature of the dry tower. A in-house code that can be easily used by field designers has been developed to predict the capacity of the appropriate heat source and the time to reach the temperature of the dry tower. A code was developed to predict unsteady heat transfer using Visual Basic for Applications. To verify the developed code, a grid independence test was performed, and finally, calculations were performed for two cases. In the first case, the time for the temperature of the heater jacket to reach 360℃ was about 1,400 seconds when the supply heat source was 1,000 W. And in the second case, the time for the temperature of the heater jacket to reach 360℃ was about 710 seconds when the supply heat source was 2,000 W. It was confirmed that the developed code well describes the actual test data of the regeneration process of adsorption and desorption, and it is judged that the code developed in the design process of various capacity systems will be effectively applied to the heat capacity calculation in the future.

혐기성 소화 가스로부터 황화합물의 제거 (Removal of Sulfur Compounds from Anaerobic Digestion Gas)

  • 최도영;장성철;안병성;최대기
    • 공업화학
    • /
    • 제19권1호
    • /
    • pp.31-36
    • /
    • 2008
  • 혐기성소화가스(ADG)를 원료로 수소를 제조하여 연료전지에 활용할 경우 ADG에 포함된 황화합물이 개질기의 촉매와 연료전지의 전극에 독으로 작용하므로 금속이온이 담지된 활성탄을 이용하여 황화합물을 제거하였다. 수분과 산소농도에 따라 고정층 흡착량이 변화하였으며, 산소 0.2 vol%, RH 90% 이상일 때 가장 높은 흡착량을 나타내었다. 본 연구에서는 KI 첨착한 활성탄에서 황화합물의 흡착특성을 고정층에서 동특성 실험을 통해 관찰하고 그 결과를 기준으로 흡착탑을 설계 제작 현장실험을 실시하였다.

고도 정수처리장에서의 과불화합물 거동 (Behavior of perfluorinated compounds in advanced water treatment plant)

  • 임채승;김형준;한개희;김호;황윤빈;김극태
    • 상하수도학회지
    • /
    • 제34권5호
    • /
    • pp.323-334
    • /
    • 2020
  • Adsorption by granule activated carbon(GAC) is recognized as an efficient method for the removal of perfluorinated compounds(PFCs) in water, while the poor regeneration and exchange cycles of granule active carbon make it difficult to sustain adsorption capacity for PFCs. In this study, the behavior of PFCs in the effluent of wastewater treatment plant (S), the raw water and the effluents of drinking water treatment plants (M1 and M2) located in Nakdong river waegwan watershed was monitored. Optimal regeneration and exchange cycles was also investigated in drinking water treatment plants and lab-scale adsorption tower for stable PFCs removal. The mean effluent concentration of PFCs was 0.044 0.04 PFHxS g/L, 0.000 0.00 PFOS g/L, 0.037 0.011 PFOA g/L, for S wastewater treatment plant, 0.023 0.073 PFHxS g/L, 0.000 0.00 PFOS g/L, 0.013 0.008 PFOA g/L for M1 drinking water treatment plant and 0.023 0.073 PFHxS g/L, 0.000 0.01 PFOS g/L, 0.011 0.009 PFOA g/L for M2 drinking water treatment plant. The adsorption breakthrough behaviors of PFCs in GAC of drinking water treatment plant and lab-scale adsorption tower indicated that reactivating carbon 3 times per year suggested to achieve and maintain good removal of PFASs. Considering the results of mass balance, the adsorption amount of PFCs was improved by using GAC with high-specific surface area (2,500㎡/g), so that the regeneration cycle might be increased from 4 months to 10 months even if powdered activated carbon(PAC) could be alternatives. This study provides useful insights into the removal of PFCs in drinking water treatment plant.

고순도 수소제조를 위한 PSA 공정에서 활성탄 충전길이 효과 (Effects of activated carbon packing length in PSA process for production of high-purity hydrogen)

  • 백은규;최민호;서성섭
    • 청정기술
    • /
    • 제7권2호
    • /
    • pp.127-132
    • /
    • 2001
  • 수소 등 다성분 혼합가스로부터 고순도의 수소를 얻기 위한 PSA 조업에 있어서 흡착탑 내 활성탄 층 충전길이의 효과를 연구하였다. 기-고상 간 물질전달은 LDF 식을 사용하였고 각 조성물질의 비선형 흡착등온선으로 변형 Langmuir 식을 사용하였다. 각각 다른 흡착성능을 가진 활성탄과 제올라이트 2개의 흡착제를 한 개의 흡착탑 내에 연속 충전시킨 결과 제품의 순도와 회수율 면에서 흡착제의 충전길이 비가 매우 중요하였다. 120 cm인 흡착탑 내 최적의 활성탄 층 길이는 $CO_2$ 농도가 최종 제거되는 부위로 결정되는데 이 때 제품의 최고 순도를 나타내는 지점이 65cm였다.

  • PDF

해수에서 6가 크롬 제거를 위한 흡착제로서의 산처리 적니 적용성 검토 (Applicability Assessment of Acid Treated Red Mud as Adsorbent Material for Removal of Six-valent Chromium from Seawater)

  • 강구;엄병환;김영기;박성직
    • 한국농공학회논문집
    • /
    • 제55권5호
    • /
    • pp.17-23
    • /
    • 2013
  • Six-valent chromium ($Cr^{6+}$) is a highly toxic pollutant, supplied in a variety of industrial activities such as leather tanning, cooling tower blowdown, and plating. Herein, we investigated the removal of $Cr^{6+}$ from aqueous phase using low-cost adsorbents. Steel slag, montmorillonite, illite, kaolinite, red mud, and acid treated red mud with 0.5, 1.0, and 2.0 M HCl were used as adsorbent for the removal of $Cr^{6+}$ and the results showed that acid treated red mud with 2.0 M HCl (ATRM-2.0 M) had higher adsorption capacity of $Cr^{6+}$ than other adsorbents used. Accordingly, $Cr^{6+}$ removal by ATRM-2.0 M were studied in a batch system with respect to changes in initial concentration of $Cr^{6+}$, initial solution pH, adsorbent dose, adsorbent mixture, and seawater. Equilibrium sorption data were described well by Freundlich isotherm model. The influence of initial solution pH on $Cr^{6+}$ adsorption was insignificant. The use of the ATRM-2.0 M alone was more effective than mixing it with other adsorbents including red mud, zeolite, oyster shell, lime stone, and montmorillonite for the removal of $Cr^{6+}$. The $Cr^{6+}$ removal of the ATRM-2.0 M was slightly less in seawater than deionized water, resulting from the presence of anions in seawater competing for the favorable adsorption site on the surface of ATRM-2.0 M. It was concluded that the ATRM-2.0 M can be used as a potential adsorbent for the removal of $Cr^{6+}$ from the aqueous solutions.