• Title/Summary/Keyword: Adjusting p-value

Search Result 83, Processing Time 0.027 seconds

A Packet Collision Avoidance Technique in IEEE1609.4 Based Time Synchronization Multi-channel Environment (IEEE1609.4 기반 시간 동기 멀티채널 환경에서의 패킷 충돌 회피 기법)

  • Jin, Seong-Keun;Lim, Ki-Taeg;Shin, Dae-Kyo;Yoon, Sang-Hun;Jung, Han-Gyun
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.385-391
    • /
    • 2015
  • In this paper, we analyze the communication performance in a time synchronous multi-channel environment and deal with a packet collision avoidance technique to improve it based on IEEE1609.4 for increasing the efficiency of the control channel IEEE802.11p WAVE communication system. In previous works, they tried to solve this problem by message scheduling method on application layer software or changing the value of the random back-off optionally Contention Window. In this paper, we propose a method for adjusting the Channel Guard Interval for packet collision avoidance. The performance was evaluated by the actual vehicle test. The result was confirmed performance over 90% PDR(Packet Delivery Ratio).

Depressive Symptoms on the Geriatric Depression Scale and Suicide Deaths in Older Middle-aged Men: A Prospective Cohort Study

  • Yi, Sang-Wook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.49 no.3
    • /
    • pp.176-182
    • /
    • 2016
  • Objectives: Prospective evaluations of the associations between depressive symptoms and suicide deaths have been mainly performed in high-risk populations, such as individuals with psychiatric disorders or histories of self-harm. The purpose of this study was to prospectively examine whether more severe depressive symptoms assessed using the Geriatric Depression Scale (GDS) were associated with a greater risk of death from suicide in a general-risk population. Methods: A total of 113 478 men from the Korean Veterans Health Study (mean age, 58.9 years) who participated in a postal survey in 2004 were followed up for suicide mortality until 2010. Results: Over 6.4 years of follow-up, 400 men died by suicide (56.7 deaths per 100 000 person-years). More severe depressive symptoms were associated with greater risk of suicide death (p for trend <0.001). The unadjusted hazard ratios (HRs) in comparison to the absence of depression were 2.18 for mild depression, 2.13 for moderate depression, 3.33 for severe depression, and 3.67 for extreme depression. After adjusting for potential confounders, men with a potential depressive disorder had an approximate 90% higher mortality from suicide (adjusted HR, 1.92; 95% confidence interval [CI], 1.38 to 2.68; p<0.001) than men without depression. Each five-point increase in the GDS score was associated with a higher risk of death by suicide (adjusted HR, 1.22; p<0.001). The value of the area under the receiver operating characteristics curve of GDS scores for suicide deaths was 0.61 (95% CI, 0.58 to 0.64). Conclusions: Depressive symptoms assessed using the GDS were found to be a strong independent predictor of future suicide. However, the estimate of relative risk was weaker than would be expected based on retrospective psychological autopsy studies.

Construction of Database for Application of APEX Model in Korea and Evaluation of Applicability to Highland Field (APEX 모델의 국내 적용을 위한 데이터베이스 구축 및 고랭지 밭에 대한 적용성 평가)

  • Koo, Ja-Young;Kim, Jonggun;Choi, Soon-Kun;Kim, Min-Kyeong;Jeong, Jaehak;Lim, Kyoung Jae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.6
    • /
    • pp.89-100
    • /
    • 2017
  • The Agricultural Policy/Environmental eXtender (APEX) model was developed to extend EPIC's capabilities of simulating land management impacts for small-medium watershed and heterogeneous farms. APEX is a flexible and dynamic tool that is capable of simulating a wide array of management practices, cropping systems, and other land uses across a broad range of agricultural landscapes. APEX have its own agricultural environmental database including operation schedule, soil property, and weather data etc., by crops. However, agriculture environmental informations the APEX model has is all based on U.S. As this can cause malfunction or improper simulation while simulating highland field. In this study, database for APEX model to be utilized for South Korea established with 44,814 agriculture fields in Pyeongchang-gun, Korea from 2007 to 2016. And assessed domestic applicability by comparing T-P unit load criteria presented by National Institution of Environmental Research and result of APEX model. As a result of APEX model simulation, average T-P value for decade was 6.18. Average T-P of every year except 2011 was in range of 5.37~10.43 and this is being involved into criteria presented by National Institution of Environmental Research. It is analyzed that adjusting slope factor can make the model applicable for domestic agricultural environment.

A Study on the Additives of mixed Gas charged in Thermostatic Bulb for Expansion Valve (팽창밸브 개폐용 감온통 혼합가스의 첨가제 연구)

  • Kim, Si-Young;Ju, Chang-Sik;Koo, Su-Jin
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.126-132
    • /
    • 2014
  • The P-T characteristics of mixed refrigerant in thermostatic expansion valve sensing bulb were studied using R-134a and R-410A refrigerant. The characteristics of mixed refrigerant were investigated according to pressure variation and the variation of composition ratio of R-134A and R-410A in the temperature range of $-15^{\circ}C{\sim}15^{\circ}C$. The Thermodynamic characteristic values of the mixed refrigerants were identified using the characteristic value analysis program of mixed refrigerant(Refrop v9.0, NIST). The P-T characteristics in the case of the mixing ratio of 90:10 for R-410A and R-134A were the same result as R-22. And the physical properties showed similar results with R-22. The Maximum operating pressure(MOP) of mixed refrigerant showed a tendency to decrease with decreasing the mixing ratio of additive gases($N_2$ or He) gases. The characteristics in the case of the mixing ratio of 80:1 for mixed refrigerant and additive gases were the similar result as Reference refrigerant.(R-22 MOP, Sporlan company) In addition $N_2$ and He, both showed the same results. It was able to confirm that a MOP on the thermostatic expansion valve sensing bulb can be maintained by adjusting the mixing ratio of mixed refrigerant gases and additive gases.

Clinical and Imaging Parameters Associated With Impaired Kidney Function in Patients With Acute Decompensated Heart Failure With Reduced Ejection Fraction

  • In-Jeong Cho;Sang-Eun Lee;Dong-Hyeok Kim;Wook Bum Pyun
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.169-177
    • /
    • 2023
  • BACKGROUND: Acute worsening of cardiac function frequently leads to kidney dysfunction. This study aimed to identify clinical and imaging parameters associated with impaired kidney function in patients with acute decompensated heart failure with reduced ejection fraction (HFrEF). METHODS: Data from 131 patients hospitalized with acute decompensated HFrEF (left ventricular ejection fraction, < 40%) were analyzed. Patients were divided into two groups according to the glomerular filtration rate (GFR) at admission (those with preserved kidney function [GFR ≥ 60 mL/min/1.73 m2] and those with reduced kidney function [GFR < 60 mL/min/1.73 m2]). Various echocardiographic parameters and perirenal fat thicknesses were assessed by computed tomography. RESULTS: There were 71 patients with preserved kidney function and 60 patients with reduced kidney function. Increased age (odds ratio [OR], 1.07; 95% confidence interval [CI], 1.04-1.12; p = 0.005), increased log N-terminal pro b-type natriuretic peptide (OR, 1.74; 95% CI, 1.14-2.66; p = 0.010), and increased perirenal fat thickness (OR, 1.19; 95% CI, 1.10-1.29; p < 0.001) were independently associated with reduced kidney function, even after adjusting for variable clinical and echocardiographic parameters. The optimal average perirenal fat thickness cut-off value of > 12 mm had a sensitivity of 55% and specificity of 83% for kidney dysfunction prediction. CONCLUSIONS: Thick perirenal fat was independently associated with impaired kidney function in patients hospitalized for acute decompensated HFrEF. Measurement of perirenal fat thickness may be a promising imaging marker for the detection of HFrEF patients who are more susceptible to kidney dysfunction.

Hydration Characteristics of Liquid Red Mud Mixed Cement Paste Neutralized with Sulfuric Acid (황산으로 중화시킨 액상 레드머드를 혼입한 시멘트 페이스트의 수화특성)

  • Kang, Suk-Pyo;Hong, Seong-Uk;Kim, Sang-Jin;In, Byung-Eun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.5
    • /
    • pp.431-439
    • /
    • 2022
  • In this study, Neutralized red mud(LRM+S) at a pH of 6-8 was prepared by adding sulfuric acid to liquefied red mud(LRM) at a pH of 10~12. After adding LRM and LRM+S to the cement paste, the hydration heat, compressive strength, and hydration products were examined. The observed accumulated hydration heat revealed that the calorific value of the cement paste with LRM was low and its and peak was delayed when compared with that of plain cement paste(referred to as Plain), whereas the calorific value of the cement paste with LRM+S was similar to that of Plain. At the age of 28 days, the compressive strength of the cement paste with 20% LRM was 55% of the strength of Plain. Using X-ray diffraction, it was determined that the cement paste with 20% LRM exhibited a Ca(OH)2 peak after 3 days, whereas the cement paste with 20% LRM+S and Plain exhibited a Ca(OH)2 peak after an hour. Thus, the strength degradation of cementitious materials was improved by adding neutralized red mud prepared by adjusting the pH of highly alkaline LRM with sulfuric acid.

A Comparison of the Adjustment Methods for Assessing Urinary Concentrations of Cadmium and Arsenic: Creatinine vs. Specific Gravity (요중 카드뮴과 비소의 보정방법 비교 : 요중 크레아티닌과 요비중)

  • Kim, Dong-Kyeong;Song, Ji-Won;Park, Jung-Duck;Choi, Byung-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.6
    • /
    • pp.450-459
    • /
    • 2011
  • Objectives: Biomarkers in urine are important in assessing exposures to environmental or occupational chemicals and for evaluateing renal function by exposure from these chemicals. Spot urine samples are needed to adjust the concentration of these biomarkers for variations in urine dilution. This study was conducted to evaluate the suitability of adjusting the urinary concentration of cadmium (uCd) and arsenic (uAs) by specific gravity (SG) and urine creatinine (uCr). Methods: We measured the concentrations of blood cadmium (bCd), uCd, uAs, uCr, SG and N-acetyl-${\beta}$-D-glucosaminidase (NAG) activity, which is a sensitive marker of tubular damage by low dose Cd exposure, in spot urine samples collected from 536 individuals. The value of uCd, uAs and NAG were adjusted by SG and uCr. Results: The uCr levels were affected by gender (p < 0.01) and muscle mass (p < 0.01), while SG levels were affected by gender (p < 0.05). Unadjusted uCd and uAs were correlated with SG (uCd: r = 0.365, p < 0.01; uAs: r = 0.488, p < 0.01), uCr (uCd: r = 0.399, p < 0.01; uAs: r = 0.484, p < 0.01). uCd and uAs adjusted by SG were still correlated with SG (uCd: r = 0.360, p < 0.01, uAs: r = 0.483, p < 0.01). uCd and uAs adjusted by uCr and modified uCr ($M_{Cr}$) led to a significant negative correlation with uCr (uCd: r = -0.367, p < 0.01; uAs: r = -0.319, p < 0.01) and $M_{Cr}$ (uCd: r = -0.292, p < 0.01; uAs: r = -0.206, p < 0.01). However, uCd and uAs adjusted by conventional SG ($C_{SG}$) were disappeared from these urinary dilution effects (uCd: r = -0.081; uAs: r = 0.077). Conclusions: $C_{SG}$ adjustment appears to be more appropriate for variations in cadmium and arsenic in spot urine.

The Relationship between Lipid Accumulation Product, Insulin Resistance and Obesity in Korean Adults (대한민국 성인에서 한국 성인의 지질 축적 지수와 인슐린 저항성 및 비만의 관련성)

  • Yoon, Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.2
    • /
    • pp.149-156
    • /
    • 2022
  • Lipid accumulation product (LAP) is a new index reflecting central lipid accumulation and is known to be a strong independent indicator for identifying the risk of cardiovascular disease (CVD) or diabetes mellitus (DM). This study was conducted to assess the relationship between the homeostasis model assessment of insulin resistance (HOMA-IR) and LAP according to the presence or absence of obesity in Korean adults. The study was carried out using data from the 2019 Korean National Health and Nutrition Examination Survey (KNHANES) and included 6,090 adults aged 20 years or older. There were several key findings. First, after adjusting for related variables, the mean of the HOMA-IR levels (M±SE, 95% confidence interval) was positively associated with the quartiles of LAP in the overall population (P<0.001), non-obese (P<0.001) or obese groups (P<0.001). Second, in all the groups (overall population, non-obese and obese groups), the mean value of the fasting blood glucose (all, P<0.001), insulin (all, P<0.001), and the metabolic syndrome score (all, P<0.001) increased with the increasing quartiles of LAP. Insulin resistance was thus positively associated with an increase in the LAP in Korean adults with or without obesity.

Fatty liver associated with metabolic derangement in patients with chronic kidney disease: A controlled attenuation parameter study

  • Yoon, Chang-Yun;Lee, Misol;Kim, Seung Up;Lim, Hyunsun;Chang, Tae Ik;Kee, Youn Kyung;Han, Seung Gyu;Han, In Mee;Kwon, Young Eun;Park, Kyoung Sook;Lee, Mi Jung;Park, Jung Tak;Han, Seung Hyeok;Ahn, Sang Hoon;Kang, Shin-Wook;Yoo, Tae-Hyun
    • Kidney Research and Clinical Practice
    • /
    • v.36 no.1
    • /
    • pp.48-57
    • /
    • 2017
  • Background: Hepatic steatosis measured with controlled attenuation parameter (CAP) using transient elastography predicts metabolic syndrome in the general population. We investigated whether CAP predicted metabolic syndrome in chronic kidney disease patients. Methods: CAP was measured with transient elastography in 465 predialysis chronic kidney disease patients (mean age, 57.5 years). Results: The median CAP value was 239 (202-274) dB/m. In 195 (41.9%) patients with metabolic syndrome, diabetes mellitus was more prevalent (105 [53.8%] vs. 71 [26.3%], P < 0.001), with significantly increased urine albumin-to-creatinine ratio (184 [38-706] vs. 56 [16-408] mg/g Cr, P = 0.003), high sensitivity C-reactive protein levels (5.4 [1.4-28.2] vs. 1.7 [0.6-9.9] mg/L, P < 0.001), and CAP (248 [210-302] vs. 226 [196-259] dB/m, P < 0.001). In multiple linear regression analysis, CAP was independently related to body mass index (${\beta}=0.742$, P < 0.001), triglyceride levels (${\beta}=2.034$, P < 0.001), estimated glomerular filtration rate (${\beta}=0.316$, P = 0.001), serum albumin (${\beta}=1.386$, P < 0.001), alanine aminotransferase (${\beta}=0.064$, P = 0.029), and total bilirubin (${\beta}=-0.881$, P = 0.009). In multiple logistic regression analysis, increased CAP was independently associated with increased metabolic syndrome risk (per 10 dB/m increase; odds ratio, 1.093; 95% confidence interval, 1.009-1.183; P = 0.029) even after adjusting for multiple confounding factors. Conclusion: Increased CAP measured with transient elastography significantly correlated with and could predict increased metabolic syndrome risk in chronic kidney disease patients.

Research Trends in Doping Methods on TiO2 Nanotube Arrays Prepared by Electrochemical Anodization (양극산화 기법으로 제조한 TiO2 나노튜브의 촉매 도핑 연구 동향)

  • Yoo, Hyeonseok;Choi, Jinsub
    • Applied Chemistry for Engineering
    • /
    • v.26 no.2
    • /
    • pp.121-127
    • /
    • 2015
  • Nanotubular $TiO_2$ prepared by electrochemical anodization has been significantly used for various applications due to high aspect ratio structures showing a high chemical stability. Morphological properties of nanotubular titanium oxide are easily tailored by adjusting types and compositions of electrolyte, pH value, applied voltage, temperature and anodization time. Since their catalytic properties can be enhanced by doping foreign elements into $TiO_2$, metal as well as non-metal elements are doped into $TiO_2$ nanotubes using different methods. For example, single anodization, thermal annealing, precipitation, and electrochemical deposition have been applied to simplify the doping process. In this review, anodization of Ti to produce $TiO_2$ and doping methods will be discussed in detail.