• Title/Summary/Keyword: Adiabatic expansion

Search Result 36, Processing Time 0.028 seconds

An Experimental Study on Application of Hydrocarbon Refrigerants for Heat Pump (히트펌프에서 탄화수소냉매 적용에 관한 실험적 연구)

  • Yoo, Seong-Yeon;Park, Dong-Seong;Kang, Tae-Seok;Lee, Je-Myo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1264-1269
    • /
    • 2004
  • This research describes the application of hydrocarbon refrigerants for heat pump system which is needed for fish farm. Tested refrigerants are HCFC-22 and hydrocarbon refrigerants(CARE 50 and ASR-20). CARE 50 is mixture of R-290 and R-170, and ASR-20 is mixture of R-152a, R-290 and other additives. Heat pump consist of shell and tube heat exchanger, scroll compressor, expansion valve and accumulator. Manual expansion valve is used for testing of wide range evaporating temperature. Hydrocarbon refrigerants show a good performance as an alternative for HCFC-22 in the range of evaporating temperature from $-6^{\circ}C$ to $6^{\circ}C$.

  • PDF

Measurement of Adiabatic Wall Temperature on an Impinging Surface by Under-expanded Jet (과소팽창된 충돌제트에 의한 단열벽면 온도 측정)

  • Yu, Man-Sun;Lee, Jang-Woo;Kim, Byung-Gi;Cho, Hyung-Hee;Hwang, Ki-Young;Bae, Ju-Chan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.79-84
    • /
    • 2005
  • An experimental investigation for impingement of under-expanded, axisymmetric jets on a flat plate has been conducted, and the surface pressure, the adiabatic wall temperature distributions on the plate have been measured in detail. For the explanation on the wall temperature distributions, the total temperature distributions along a free jet have also been measured with total temperature probes. In this study, the under-expansion ratio and the nozzle-to-plate distance have been considered as experimental parameters. Depending on nozzle-to-plate distances, different distributions of adiabatic wall temperature are shown by the energy separation at a jet edge and a impinged surface. Also, the recovery factor on a stagnation point decreases significantly due to the isolation of fluid particles in a central region.

A Study on the domestic power plant roof waterproofing system & insulation efficiency (국내 발전소 지붕방수설계 시스템 및 단열 성능에 관한 연구)

  • Chung, Kwang-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.1
    • /
    • pp.33-42
    • /
    • 2011
  • As the development of construction technology and new materials, building requirements has been varied gadually. Comfortable environment and serviceability of production activity and energy conservation are being dealt with very seriously. Recently localization of engineering technology of Power Plant, however, construction materials and domestic technology are being developed forcingly. According to above topics this thes is going to study roof waterproofing, thermal insulation and evaluate adiabatic performance and evaluation of properties of waterproofing materials and energy conservation. The results of studying and evaluating of roof waterproofing, thermal insulation and adiabatic performance of Power Plant are as follows. 1. Sheet waterproofing method is better than that of asphalt waterproofing method in that adaptability of wearhertight, thermal resistant, contraction and expansion. 2. It is required to replace polyurethane or ethylene used as thermal insulation with rock wool which is noncombustible materials. 3. It is recommended to usd outer insulation method than inner insulation method due to superioty of outer insulation method. Efficiency of insulation materials used in power plant is generally good except perlite mortar used in the power plant(YGN 1-2, GRI 1-2).

An Approximate Analysis Method to Predict Power Output Characteristics of Stilting Engine (스터얼링 기관의 근사 출력 계산법)

  • 김태한;장익주;이시민
    • Journal of Biosystems Engineering
    • /
    • v.20 no.3
    • /
    • pp.205-216
    • /
    • 1995
  • A fast and inexpensive approximate analysis method to predict power output characteristics of the Stilting engines in a preliminary design stage was investigated. In basic equations proposed by Walker, typical temperatures of working fluids in expansion and compression spaces were treated as those of working fluids in heater and cooler respectively. While the temperature of working fluid in the expansion space was actually lower than that of working fluid in the heater, the temperature of working fluid in the compression space was higher than that of working fluids in the cooler. In this paper, the working fluid temperature of expansion space was treated as lower than the heater temperature and that of compression space was treated as higher than the cooler temperature. Also, according to them, the power output characteristics of the Stirling engine were evaluated with respect to the GPU-3 and 4-215 Stilting engines. The following conclusions were drawn from the analysis. 1. Using the available experimental data from the GPU-3 Stirling engine, it was shown that the approximate analysis predicts the brake power with a maximum error of 19 percent at 1, 000rpm and with a minimum error of 3 percent at 2, 000rpm. 2. The approximate analysis data which for the GPU-3 Stirling engine were much closer to the experimental data than those of adiabatic 2nd order and 3rd order analysis within 1, 500rpm to 2, 500rpm. 3. The approximate analysis data which for the GPU-3 and 4-215 Stilting engines were much closer to the experimental data than those of the Beal number analysis.

  • PDF

A Study on the Characteristics of the Adiabatically Expanded Polyolefin Structured Foams (단열 발포 폴리올레핀계 구조체의 특성에 관한 연구)

  • Hwang Jun-Ho;Kim Woo-nyon;Jun Jae-Ho;Kwak Soon-Jong;Hwang Seung-Sang;Hong Soon-Man
    • Polymer(Korea)
    • /
    • v.29 no.6
    • /
    • pp.605-612
    • /
    • 2005
  • This study investigates the isothermal crystallization behaviors of polypropylene-polyethylene-(1-butene) terpolymer and the adiabatically expanded polyolefin structured foams. For this purpose, butane gas was used as a physical blowing agent. Avrami equation has been used to interpret theoretically the experimental results obtained by either DSC or polarized optical microscope. It is believed that elongation induced crystallization occurring during the adiabatic expansion process has resulted in an increase in crystallization rate, eventually leading to a faster growth rate of spherulites and an increase in the nucleation density. An analysis of the foam by SEM images showed that the structure of foam is uniform (below diameter 30 $\mu$m closed cell) In addition, the thermal conductivity and the compressive strength of the polyolefin structured foams was measured. The thermal conductivity of foamed resin with excellent insulation characteristics is reduced compared with unfoamed resin. The compressive strength is decreased with increase in the expansion ratio.

Fundamental Properties of Fly ash Concrete Containing Lightly Burnt MgO Powder (저온 소성한 MgO 분말을 함유한 플라이애시 콘크리트의 기본 물성)

  • Choi, Seul-Woo;Jang, Bong-Seok;Lee, Kwang-Myong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.475-481
    • /
    • 2013
  • Although the lightly burnt MgO at $850{\sim}1000^{\circ}C$ has expansibility, it does not lead to unsound concrete. The expansion of MgO could compensate for shrinkage of concrete for a long-term, because the hydration of MgO occurs at a slow pace. Recently, the study and application of mineral admixture such as fly ash and blast furnace slag have increased for the hydration heat reduction, durability improvement, and reducing $CO_2$ emission in the construction industry. Thus, it is necessary to research on the concrete that contains both a mineral admixture and MgO as an expansion agent. This study investigates fundamental properties of fly ash concrete with lightly burnt MgO through various experiments. The adiabatic temperature test results showed that the fly ash concrete with MgO of the 5% replacement ratio had the slower pace of the temperature rise and the lower final temperature than the fly ash concrete. The influences of MgO on long-term compressive strength varied depending on water-binder ratio, and the long-term length change test results indicated the expansion effects of the FA concrete containing MgO.

A Three-Dimensional Numerical Analysis of In-Cylinder Flows in Reciprocating Model Engine (3차원 모형기관 실린더내의 흡입과정 유동에 대한 수치해석)

  • 하각현;김원갑;최영돈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.3
    • /
    • pp.1-12
    • /
    • 1994
  • A model engine having a flat cylinder head and a piston face and an off-center intake valve is investigated in this analysis. Calculation domain is confined to the half of the cylinder with swirl free inlet velocity condition. Due to the absence of measured inlet conditions, the inlet flowrates during induction period are calculated from overall mass and energy conservation requirements. Finite difference equation for velocity and pressure were solved by modified SIMPLER algorithm, standard k-$\varepsilon$turbulence model and hybrid scheme. From the result of prediction, dimensionless velocity distribution and turbulence intensities are investigated at each crank angle.

  • PDF

Development and Evaluation of Hy-CPC (Hy-CPC의 개발 및 성능평가)

  • Lee, Hong-Ku;Hwang, In-Kyu;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.10 no.3
    • /
    • pp.93-97
    • /
    • 2014
  • Condensation particle counter (CPC) has been one of the most important basic instrument for measuring number concentration of submicron aerosols. The principle of the CPC is to expose aerosols to a supersaturated vapor and cool down which causes adiabatic expansion. The particles grow by heterogenous nucleation to a sufficient size for easy detection by optical method. However, for growth by condensation, CPC essentially needs both saturater and condensor causing a heavy system. Therefore, it is hard to install commercial CPC to tethered balloon package system. In this study, we developed customized CPC for tethered balloon package system called Hy-CPC which is lighter and smaller in structure than commercial CPCs, and evaluated activation efficiency and detection efficiency by Hy-CPC using electrostatic method (electrometer and Faraday cup).

Basic Properties of Dam Concrete using Fly Ash (Fly Ash를 이용한 댐 콘크리트의 기본 물성에 관한 연구)

  • 송영철;우상균;방기성;정원섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.619-624
    • /
    • 1999
  • The purpose of this study is to provide the optimum mix design of fly ash concrete to be placed at the concrete face rockfill dam for pumped storage power plats. The basic performance tests including compressive strength, modulus of elasticity, unit weight, coefficient of thermal expansion, shrinkage, adiabatic temperature rise and analysis of thermal stress were conducted for fly ash concrete. From this study, the fly ash concrete represented the better results in the aspects of basic performance and economy than ordinary portland cement concrete. Especially the concrete mix design containing 15% of fly ash is recommended to be applied in the construction of the concrete face rockfill dam for pumped storage power plants.

  • PDF

Study on the Parameters affecting Thermal Stress in Mass Concrete (매스콘크리트에서 온도응력에 영향을 주는 인자에 대한 연구)

  • 이대근;김종우;하재담;김기수;차수원;오병환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.211-216
    • /
    • 1998
  • Parameter analysis of mass concrete structures of two types subjected to heat of hydration and surface heat transfer is presented. Thermal stress analysis is conducted through the 3D FEM program. Thermal and mechanical properties of concrete, for example, conductivity, heat capacity, density, thermal expansion coefficient are varied from 80% to 120% of a reference value, and the change of thermal stress against the parameter is achieved respectively. As a result of the analysis, the parameter affecting thermal stress most significantly is an adiabatic temperature rise in the case of wall-type structure, and an initial temperature of concrete in the case of slab-type structure, respectively.

  • PDF