• 제목/요약/키워드: Adiabatic Line

검색결과 34건 처리시간 0.02초

$Au/YBa_2Cu3O_7$ 곡선에 인가가능 전압 (Voltage Applicable to $Au/YBa_2Cu3O_7$ Meander Lines)

  • 김혜림;임성우;유승덕;박충렬;양성은;김우석;현옥배
    • Progress in Superconductivity
    • /
    • 제12권1호
    • /
    • pp.62-67
    • /
    • 2010
  • We investigated the voltage applicable to $Au/YBa_2Cu3O_7$ (YBCO) meander lines. The meander line was fabricated by patterning Au/YBCO thin films grown on sapphire substrates by photolithography. It was subjected to simulated AC fault currents, and the resistance was measured and analyzed. The samples were immersed in liquid nitrogen during the experiment for effective cooling. The voltage applicable to the meander lines depended on the fault duration. Dependence was strong at short fault durations, and weak at long durations. When the voltage was plotted as a function of the fault duration on a log-log scale, data fell more or less on straight lines for all meander lines. In other words, the voltage applicable to Au/YBCO meander lines on sapphire substrates was inversely proportional to $t^b$, where t is the fault duration and b ranges from 0.4 to 0.5. The results were analyzed quantitatively with the concept of heat balance. Under adiabatic condition, the voltage is to be inversely proportional to $t^{0.5}$ for all samples. Less value of b for some samples is thought to be due to cooling of the samples by liquid nitrogen.

마이크로채널관 내 2상 유량분배, 상분리 및 압력강하 (Two-Phase Flow Distribution, Phase Separation and Pressure Drop in Multi-Microchannel Tubes)

  • 조홍기;조금남;윤백;김영생;김정훈
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.828-837
    • /
    • 2004
  • The present study investigated two-phase flow distribution, phase separation and pressure drop in multi-microchannel tubes under adiabatic condition. The test section consisted of inlet and outlet headers with the inner diameter of 19.4㎜ and 15 parallel microchannel tubes. Each microchannel tube brazed to the inlet and outlet headers and had 8 rectangular ports with the hydraulic diameter of 1.32㎜. The key experimental parameters were orientation of header (horizontal and vertical), flow direction of refrigerant into the inlet header (in-line, parallel and cross flow) and inlet quality (0.1, 0.2 and 0.3). It was found that the orientation of the header had relatively large effect on the flow distribution and phase separation, while the inlet quality didn't affect much on them. The horizontal header showed the better flow distribution and phase separation characteristics than the vertical one. The parallel flow condition with the horizontal header showed the best performance for the flow distribution and phase separation characteristics under the test conditions. Two-phase pressure drops through the microchannel tubes with the horizontal header were higher than those of the microchennel tubes with the vertical header due to gravitational effect.

합성가스(H2/CO)/공기 예혼합 충돌화염의 연소 및 열전달 연구 Part II : 열전달 특성 (A Study on Combustion and Heat Transfer in Premixed Impinging Flames of Syngas(H2/CO)/Air Part II: Heat Transfer Characteristics)

  • 심근선;정병규;이용호;이기만
    • 한국수소및신에너지학회논문집
    • /
    • 제25권1호
    • /
    • pp.59-71
    • /
    • 2014
  • An experimental study has been conducted to investigate the heat transfer characteristics of laminar syngas/air mixture with 10% hydrogen content impinging normally to a flat plate of cylinder. Effects of impinging distance, Reynolds number and equivalence ratio as major parameters on heat fluxes of stagnation point and radial direction were examined experimentally by the direct photos and data acquisitions from heat flux sensor. In this work, we could find the incurved flame behavior of line shaped inner top-flame in very closed distance between flat plate and burner exit, which has been not reported from general gas-fuels. There were 3 times of maximum and 2 times minimum heat flux of stagnation point with respect to the impinging distance for the investigation of Reynolds number and equivalence ratio effect. It was confirmed that the maximum heat flux of stagnation point in 1'st and 2'nd peaks increased with the increase of the Reynolds number due to the Nusselt number increment. There was a third maximum rise in the heat flux of stagnation point for larger separation distances and this phenomenon was different each for laminar and turbulent condition. The heat transfer characteristics between the stagnation and wall jet region in radial heat flux profiles was investigated by the averaged heat flux value. It has been observed that the values of averaged heat flux traced well with the characteristics of major parameters and the decreasing of averaged heat flux was coincided with the decreasing trend of adiabatic temperature in spite of the same flow condition, especially for impinging distance and equivalence ratio effects.

2020년 3월 18일-20일 영동지역 강풍 사례 연구 (A Case Study of Strong Wind Event over Yeongdong Region on March 18-20, 2020)

  • 안보영;김유준;김백조;이용희
    • 한국지구과학회지
    • /
    • 제42권5호
    • /
    • pp.479-495
    • /
    • 2021
  • 본 연구는 2020년 3월 18일부터 20일까지 영동지역에 강풍이 발생했던 사례(남고북저형, 대류권계면 접힘에 의해 급격하게 발달하는 저기압)의 종관 및 열역학적/운동학적특성을 조사하기 위해 AWS 관측 자료, 종관 일기도, ECMWF 재분석 자료, 레윈존데, 윈드프로파일러 자료를 이용하였다. 분석결과, 사례 기간 영동지역 5개소에서 관측된 최대 순간 풍속은 20 m s-1 이상으로 나타났으며 대관령(27.7 m s-1)에서 가장 강하게 나타났다. 종관분석에서는 남고북저형의 기압배치와 함께 영동지역으로 등압선의 모양이 사인(sin)파 형태를 보이며 강한 기압경도력에 의해 강풍이 발달하다가 3월 19일부터는 한반도 북부지역에서 하루 내에 19 hPa 이상의 기압 하강과 함께 발달하는 저기압에 의해 지속적인 강풍이 발달했다. 북강릉 단열선도에서 역전층의 고도는 하층 강풍대와 함께 산 정상의 약 1-3 km 고도에 위치하였고, 레윈존데 및 수직 측풍 장비(윈드프로파일러)의 연직 바람장 분석 결과와 일치함을 확인할 수 있었다. 특히 열역학적 및 운동학적 연직 분석에서, 하층에서 온위의 연직 경도에 의한 강한 바람과 대류권계면 접힘에 의한 위치 소용돌이도의 발달이 영동지역 강풍 발생에 큰 역할을 한 것으로 사료된다.