• Title/Summary/Keyword: Adhesive glue

Search Result 87, Processing Time 0.031 seconds

Experimental Evaluation of Shear Bonding Performance of Wood-Steel Composite Members (목재-강재 합성 부재의 전단 부착 성능에 대한 실험적 평가)

  • Park, Keum-Sung;Lee, Sang-Sup;Kwak, Myong-Keun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.4
    • /
    • pp.53-60
    • /
    • 2019
  • In this study, an experimental study was carried out to evaluate the bond shear performance according to the shear connector between the glue-laminated timber and steel interface. Ten block shear specimens were fabricated according to the configuration of the adhesive surface of wood and steel. In addition, four test specimens were produced according to the main variable shape of the wood-concrete shear connector. As a result of the block shear test, the shear strength of the steel-wood adhesive is shown to have a shear performance greater than the wood-wood shear strength. As a result of the push-out test according to the shape of the shear connector, the shear strength increased linearly with the attachment area. The complete composite behavior between the glued-laminated timber and the steel can be secured.

Efficacy of 2 mm Videothoracoscopic Examination and Application of Fibrin Glue in Bullectomy of Primary Spontaneous Pneumothorax (원발성 자연기흉 환자에서 2mm 흉강경 검사와 기포절제술 후 Fibrin Glue 도포의 효용성)

  • 이덕헌;금동윤;박창권
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.438-443
    • /
    • 2004
  • Background : The treatment strategy for urinary spontaneous pneumothorax has progressively changed with the introduction of video-assisted thoracic surgery (VATS). Recently, we modified the strategy of primary spontaneous pneumothorax. If the patient had mild dyspnea and the lung was minimally collapsed, 2 mm thoracoscopic examination was performed. If no blob or bullae was inspected, the intrathoracic air was evacuated through the 2 mm thoracoscopic troca without closed thoracostomy, and if the blob and bullae was noted, the 10 mm thoracoscopic bullecotomy was carried out immediately and also application of fibrin glue was substituted for pleural abrasion. We compared the clinical outcomes of modified treatment strategy with conventional strategy in primary spontaneous pneumothorax. Material and Method: Patients were divided into four groups. Group I (n=21) underwent 2 mm thoracoscopic examination. Group II (n=68) underwent closed thoracostomy. Group III (n=56) underwent VATS and application of fibrin glue. Group IV (n=87) underwent VATS and pleural abrasion. The duration of chest tube drainage, the duration of hospitalization and the recurrence rate were compared between group I and group II and between group III and group IV. Result: Mean age, sex, location of pneumothorax were not different in all groups. In group I, the blob or bullae were existed in 12 patients, In remaining 9 patients, the bleb or bullae was not inspected. The mean duration of hospitalization in 9 patients were 2.4 $\pm$1.0 day and in group II were 3.9$\pm$2.1 day (p=0.014). There was 1 case of recurrence among the 9 patients in group I and 26 recurrences in group II (p=0.149). The mean duration of chest tube drainage were not difference in group III and IV (group III: 2.8$\pm$1.8 day, group IV: 3.0$\pm$2.5 day). The mean duration of hospitalization was shorter in group III than group IV (group III: 5,6$\pm$2.7 day, group IV: 1.3$\pm$3.3 day)(p=0.002). There was no recurrence in group III and 7 recurrences in group IV (p=0.043). Conclusion: Our modified treatment strategy of primary spontaneous peumothorax was effective in short hospital course and low recurrence rate.

Study on the manufacturing of high-frequency heating Japanese cedar laminated board by finger jointing method (1) - Gluing characteristics of Japnese cedar board by PVAc emulsion adhesives - (핑거접합방식에 의한 삼나무의 고주파가열 집성판 제조에 관한 연구 (1) - 삼나무 판재의 초산비닐수지 접착특성 -)

  • So Won-Tek;Chai Jyung-Ki
    • Journal of the Korea Furniture Society
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This experiment was carried out to investigate the gluing characteristics of poly vinyl acetate emulsion adhesive(PVAc) on the Cryptomeria japonica laminated boards. This sample trees are major planting species and have been planted in southern district for a long time. The optimum gluing conditions for laminated board were summarized as follows; the amount of spreading glue, assembly time, clamping pressure, and clamping time for PVAc resin were $200g/m^2$, 10min., $5kg/cm^2$, and 6hrs., respectively, and the relative formulae between extension ratio(x) and block shear strength(y) was $y=-9.6x+85.2(R^2=0.95)$.

  • PDF

An Experimental study on bonding performance evaluation of Bi-compressive strength concrete according to surface preparation (접착 면 처리 방법에 따른 이종 압축강도 콘크리트의 접착성능 평가에 관한 실험적 연구)

  • Kim, Min-Seong;Lim, Hee-Seob;Lee, Han-Seung;Yang, Won-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.282-283
    • /
    • 2014
  • An active study on UHPC, which has been recently used in high-rise building and bridges, is in progress. However, research on adhesion strength of normal concrete and UHPC is required to be studied due to the lack of information. In this study, experimental research progress for adhesion strength (shear strength of adhesive surface) evaluation of Bi-compressive strength concretes (UHPC, Normal concrete) is proceeded. First, specimens using glue are produced and surface treatment methods of concrete bonded section are considered. Second, Direct Shear test is applied on concrete bonded section of UHPC (80~180MPa) and Normal Concrete (NC). As a result of this study, it is confirmed that bond strength is deteriorated as the difference of intensity ration of NC and UHPC increases.

  • PDF

Joining of Polymer Materials with Ultrasonic Welding (초음파 용접을 이용한 합성수지의 결합)

  • 이철구;정규창
    • Journal of Welding and Joining
    • /
    • v.16 no.2
    • /
    • pp.48-56
    • /
    • 1998
  • This study was performed to find the best bonding conditions by comparing mechanical properties in thermoplastic resin of polyethylene (PE) and polyamide (PA) adhesion. Following results were obtained from the tests with varying welding time and welding pressure. Satisfactory adhesion was executed in ultrasonic welding for the same materials of PE and PA. The best welding conditions were found to be welding time of 1 second, welding pressure of 250kPa for PE-PE weding, 2 second and 350kPa for PA-PA welding. Welding time and welding pressure end to increase with the increase of materials strength. Dissimilar materials were adhered when adhesion and ultrasonc welding were performed simultaneously. The observation of the structure of ultrasonic welding area with microscope showed differenticated structures between well adhered region and badly adhered region.

  • PDF

Adding Effect of TCA-Precipitated Blood Powder to the Phenol Formaldehyde Resin for Plywood (합판용 페놀수지 접착제에 대한 TCA침전 혈액분말의 첨가효과)

  • Lee, Hwa-Hyoung;Lee, Jong-Shin;Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.15-19
    • /
    • 1996
  • To utilize the waste materials and develope wood adhesive from isolated bloods of slaughtered cow and pig and also to prevent water pollution, simple and rapid method of isolation and purification of plasma proteins from pig bloods with trichloroacetic acid(TCA) treatment was developed. Adding of TCA-precipitated blood powder to the phenol formaldehyde resin(PF) improved dry and wet strength of plywood and resulted in fast hot pressing times.

  • PDF

An Assessment of the Deterioration of Fabricated Metal Thread with Light, and Temperature and Humidity Factors: A Focused Study of Asian Textile Collections at the Metropolitan Museum of Art, New York

  • Park, Hae Jin;Hwang, Minsun;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.34 no.4
    • /
    • pp.245-257
    • /
    • 2018
  • To investigate the deterioration of textiles with metal thread, I surveyed 40 textile objects, dating from the 11th to the 19th century from Korea, China, Japan, and Central Asia at the Metropolitan Museum of Art, New York. This survey included various types, widths, and thicknesses of metal thread. In addition, deterioration was examined under the microscope and color information was collected using the spectrophotometer. While investigating metal thread in the collections, I fabricated 12 different types of metal samples with metal leaf(24K gold, silver, and copper leaf), adhesive (hide animal glue and a mixture of hide animal glue and iron oxide red), and paper substrate(Korean mulberry and Taiwanese kozo paper). The accelerated deterioration process of those fabricated samples was carried out using a light box(UV and daylight), and a humidity cabinet. In the light experiment with blue scales textile fading card(aka, blue wool standard), the metal leaf began to peel off during the deterioration process with 756,000 lux-hours UV and daylight. In the temperature and humidity experiment, I could observe the reddish tarnish on copper, and some part of it began to peel off. Color reading on the light exposed samples showed that the degree of color change on the surface follows the amount of exposure as it increased over time. On the other hand, color change on the samples after artificial deterioration using temperature and humidity factors showed random change of color with occasional spikes. Distortion of original shape worsened in the samples exposed to temperature and humidity.

Fibrin Sealant and Lipoabdominoplasty in Obese Grade 1 and 2 Patients

  • Mabrouk, Amr Abdel Wahab;Helal, Hesham Aly;Al Mekkawy, Soha Fathy;Mahmoud, Nada Abdel Sattar;Abdel-Salam, Ahmed Mohamed
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.621-626
    • /
    • 2013
  • Background Ever since lipoabdominoplasty was first developed to achieve better aesthetic outcomes and less morbidity, the rate of seroma formation, especially in obese patients, has disturbed plastic surgeons. The aim of this study was to evaluate the effect of fibrin sealant in the prevention of seroma formation after lipoabdominoplasty in obese patients. Methods Sixty patients with a body mass index (BMI) between 30 and 39.9 were assigned randomly to 1 of 2 groups (30 patients each). Group A underwent lipoabdominoplasty with fibrin glue, while group B underwent traditional lipoabdominoplasty; both had closed suction drainage applied to the abdomen. The patients' demographics and postoperative complications were recorded. Seroma was detected using abdominal ultrasound examinations at two postoperative periods: between postoperative days 10 and 12 and, between postoperative days 18 and 21. Results The age range was 31 to 55 years ($38.5{\pm}9.5$ years) in group A and 25 to 58 years ($37.8{\pm}9.1$ years) in group B, while the mean BMI was 31.4 to 39.9 $kg/m^2$ (32.6 $kg/m^2$) in group A and 32.7 to 37.4 $kg/m^2$ (31.5 $kg/m^2$) in group B. In group A, the patients had a complication rate of 10% in group A versus 43% in group B (P<0.05). The incidence of seroma formation was 3% in the fibrin glue group but 37% in the lipoabdominoplasty-alone group (P<0.05). Conclusions Lipoabdominoplasty with the use of autologous fibrin sealant is a very effective method that significantly reduces the rate of postoperative seroma.

Effects of Adhesion Conditions on Bonding Strength of Pitch Pine Woods for Glued-Laminated Wood (리기다소나무 판재(板材)의 접착조건(接着條件)이 집성재(集成材)의 접착성능(接着性能)에 미치는 영향(影響))

  • Park, Sang-Bum;Kong, Young-To;Jo, Jae-Myeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.48-53
    • /
    • 1988
  • This study was carried out to investigate the effects of pressing time and spreading amount, moisture content, gap-distance with butt to butt joint and adhesives on bonding strength in manufacturing the laminated wood with Pitch pine (Pinus rigida). The results obtained were as follows: 1) The pressing time of 12 hours, 10 kilogram per square centimeter of pressure and 200 gram per square meter of spreading amount were required to reach over 50 kilogram per square centimeter (block shear strength) in manufacturing the laminated wood by aqueous vinyl urethane adhesive. 2) The bonding strength decreased with the increase of moisture content of wood. The block shear strength, however, showed over 100 kilogram per square centimeter when the strength test was carried out after air-drying the laminated wood in high moisture content (30-70%). 3) Regardless of direction of load, every flexural property decreased with the increase of gap-distance with butt to butt joint. However, little of every flexural property was changed at 0.5 millimeter of joint-gap distance. The flexural property of vertically laminated wood (perpendicular to glue line to load direction: 1) showed more than that of horizontally laminated wood (parallel to glue line to load direction: //). 4) Among five adhesives used at this experiment, the bonding strength of aqueous vinyl urethane adhesive was the highest in dry bond and wet tests.

  • PDF

Comparing intra-oral wound healing after alveoloplasty using silk sutures and n-butyl-2-cyanoacrylate

  • Suthar, Pratik;Shah, Sonal;Waknis, Pushkar;Limaye, Gandhali;Saha, Aditi;Sathe, Pranav
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.1
    • /
    • pp.28-35
    • /
    • 2020
  • Objectives: The need for proper wound closure is of paramount importance after any intra-oral surgery. Various wound closure techniques have been described in literature using traditional non-absorbable suture materials. These include like synthetic absorbable sutures, surgical staples and tissue adhesives. Cyanoacrylates are among the most commonly used biocompatible tissue adhesives. To evaluate and compare intraoral wound healing using 3-0 silk sutures and n-butyl-2-cyanoacrylate after alveoloplasty. Materials and Methods: A total of 20 patients requiring bilateral alveoloplasty in the same arch (upper or lower) were included in this study. Patients with any pre-existing pathology or systemic disease were excluded. After alveoloplasty was performed, the wound was closed using 3-0 braided silk sutures on one side, and using n-butyl-2-cyanoacrylate bio adhesive on the other side. Patients were evaluated based on the following parameters: time required to achieve wound closure; the incidence of immediate and postoperative hemostasis; the time to the use of the first rescue medication; the side where pain first arises; and the side where wound healing begins first. Results: Compared to 3-0 silk sutures, cyanoacrylate demonstrated better hemostatic properties, reduced operative time, reduced postoperative pain and better wound healing. Conclusion: These data suggest that cyanoacrylate glue is an adequate alternative to conventional sutures to close the surgical wound after alveoloplasty, and better than are 3-0 silk sutures.