Current limiting characteristics of transformer type SFCL with coupled secondary windings according to its winding direction

  • Han, Tae Hee;Lim, Sung Hun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권2호
    • /
    • pp.44-47
    • /
    • 2017
  • In this paper, the current limiting characteristics of the transformer type superconducting fault current limiter (SFCL) with the two coupled secondary windings due to its winding direction were analyzed. To analyze the dependence of transient fault current limiting characteristics on the winding direction of the additional secondary winding, the fault current limiting tests of the SFCL with an additional secondary winding, wound as subtractive polarity winding and additive polarity winding, were carried out. The time interval of quench occurrence between two superconducting elements comprising the transformer type SFCL with the additional secondary winding was confirmed to be affected by the winding direction of the additional secondary winding. In case of the subtractive polarity winding of the additional secondary winding, the time interval of the quench occurrence in two superconducting elements was shorter than the case of the additive polarity winding.

Transient Fault Current Limiting Characteristics of a Transformer Type SFCL Using an Additional Magnetically Coupled Circuit

  • Lim, Seung-Taek;Lim, Sung-Hun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권1호
    • /
    • pp.42-45
    • /
    • 2017
  • In this paper, a transformer type SFCL (superconducting fault current limiter) using an additional magnetically coupled circuit was suggested. Its transient fault current limiting characteristics, due to the winding direction of additional coupled circuit, were analyzed through fault current limiting tests. The suggested transformer type SFCL was composed of the primary winding, and one secondary winding wound on the same iron core together with an additional magnetically coupled circuit. That circuit consists of the other secondary winding together with the other SC (superconducting) element connected in parallel with its other secondary winding. As one of the effective design parameters to affect the transient fault current of the SFCL, the fault current limiting tests of the suggested SFCL were carried out considering the winding direction of its additional coupled circuit. It was confirmed that, through the analysis on the fault current tests of the SFCL, the quench sequence of two SC elements comprising the suggested SFCL could be adjusted by the winding direction of the additional coupled circuit.

Cell Balancing Method in Flyback Converter without Cell Selection Switch of Multi-Winding Transformer

  • Kim, Jin-Woong;Ha, Jung-Ik
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.367-376
    • /
    • 2016
  • This paper presents a cell balancing method for a single switch flyback converter with a multi-winding transformer. The conventional method using a flyback converter with a multi-winding transformer is simple and easy to control, but the voltage of each secondary winding coil might be non-uniform because of the unequal effective turn-ratio. In particular, it is difficult to control the non-uniform effect using turn-ratios because secondary coil has a limited number of turns. The non-uniform secondary voltages disturb the cell balancing procedure and induce an unbalance in cell voltages. Individual cell control by adding a switch for each cell can reduce the undesirable effect. However, the circuit becomes bulky, resulting in additional loss. The proposed method here uses the conventional flyback converter with an adjustment made to the output filters of the cells, instead of the additional switch. The magnitude of voltage applied to a particular cell can be reduced or increased according to the adjusted filter and the selected switching frequency. An analysis of the conventional converter configuration and the filter design method reveals the possibility of adequate cell balancing control without any additional switch on the secondary side.

Analysis on Current Limiting Characteristics of Transformer Type SFCL with Additionally Coupled Circuit

  • Lim, Seung-Taek;Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.533-539
    • /
    • 2018
  • In this paper, the transformer type superconducting fault current limiter (SFCL) with additionally coupled circuit was suggested and its peak fault current limiting characteristics due to the fault condition to affect the fault current were analyzed through the fault current limiting tests. The suggested transformer type SFCL is basically identical to the previous transformer type SFCL except for the additional coupled circuit. The additional coupled circuit, which consists of the magnetically coupled winding to the primary and the secondary windings together with another superconducting element and is connected in parallel with the secondary winding of the transformer type SFCL, is contributed to the peak fault current limiting operation for the larger transient fault current directly after the fault occurrence. To confirm the fault current limiting operation of the suggested SFCL, the fault current limiting tests of the suggested SFCL were performed and its effective peak fault current limiting characteristics were analyzed through the analysis on the electrical equivalent circuit.

A Zero Voltage Switching Phase Shift Full Bridge Converter with Separated Primary Winding

  • Kim, Young-Do;Kim, Chong-Eun;Cho, Kyu-Min;Park, Ki-Bum;Cho, In-Ho;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.379-381
    • /
    • 2008
  • Generally additional leakage inductance and two clamp diodes are adopted into the conventional phase shift full bridge (PSFB) converter for reducing the voltage stress of secondary rectifier diodes and extending the range of zero voltage switching (ZVS) operation. However, since additional leakage inductance carries the ac current similar to the primary one, the core and copper loss oriented from additional leakage inductance can be high enough to decrease the whole efficiency of DC/DC converter. Therefore, in this paper, a new ZVS phase shift full bridge converter with separated primary winding (SPW) is proposed. Proposed converter makes the transformer and additional leakage inductor with one ferrite core. Using this method, leakage inductance is controlled by the winding ratio of separated primary winding. Moreover, by manufacturing the both magnetic components with one core, size and core loss can be reduced and it turns out the improvement of efficiency and power density of DC/DC converter. The operational principle of proposed converter is analyzed and verified by the 1.2kW prototype.

  • PDF

노이즈 차폐 변압기의 주파수 특성 분석 (A analysis of frequency characteristics for the noise cut transformer)

  • 김명석;오준식;조현길;한규환;박종화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.957-959
    • /
    • 2005
  • A noise reduction equipment in power systems was device combined in a passive element such as the form of L, R and C. A analysis of frequency characteristics for the transformer models shall be considered the additional capacitance between the windings($C_{ps}$), terminals($C_s$), and winding-ground($C_g$). A noise in transformer is modeled by take account into the different frequency. In case of the high frequency, transformer windings with stray capacitance have lower impedance. Therefore a noise is transferred from primary winding to secondary winding. Noise Cut Transformer(NCT) was the noise reduction device and was normally single phase two-winding type transformer. We analyzed frequency characteristics using the nodal network analysis with the equivalent circuit and the simulation of the MATLAB.

  • PDF

커플드 인덕터를 활용하여 출력 전류 리플을 저감하는 LLC 공진형 컨버터에 관한 연구 (A Study on LLC Resonant Converter Employing Coupled Inductor to Reduce Output Current Ripple)

  • 이용철;강민혁;강찬호;홍성수
    • 전력전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.208-216
    • /
    • 2018
  • In this paper, an LLC resonant converter employing two coupled inductors on the secondary side of the converter is proposed. The conventional LLC converter exhibits serious power loss during secondary winding of the transformer because of generation of tremendous output current ripples. To overcome this problem, an LLC resonant converter with a current doubler as a rectifying circuit was recently proposed. However, the current-doubler rectifying circuit requires coupled inductors with a high coupling ratio to retain the designed resonance characteristics. Therefore, an additional hardware filter is required at the output stage to address large output current ripples. Additional design procedures are also necessary because the inductance component of the added filter affects the designed resonant network. To solve this issue, an LLC resonant converter employing two coupled inductors is proposed in this paper. Mathematical analysis shows that the proposed secondary-side current-doubler circuit does not affect the designed resonance characteristics. The operating principles and theoretical analyses are proven through a simulation and experiments with a 54 V/28 A prototype.

새로운 시분할 다중 제어 기법에 기반한 다중 출력 충전기 (Multiple Output Charger based on the Novel Time Division Multiple Control Technique)

  • 트란반롱;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.13-14
    • /
    • 2013
  • Multiple output converters (MOCs) are widely used for applications which require various kinds of the output voltages due to its advantages in cost, volume, and efficiency. However, most of the MOCs developed so far can regulate only one output tightly and require as many secondary windings in the transformer as the number of the outputs. In this paper, a novel Time Division Multiple Control (TDMC) method to regulate all the outputs in high precision is proposed and applied to the double ended forward converter for the multiple battery charger. Additional benefit of the proposed topology is to require only one secondary winding in the transformer for all the outputs. The proposed converter can charge two different kinds of batteries or same kind of batteries in different state of charges (SOCs) by CC/CV mode independently with the even degree of tight regulation, thereby satisfying the ripple requirements for each battery.

  • PDF

전자석형 리니어 하이브리드모터의 과도특성 해석 (Transient Characteristics of Electromagnet Type Linear Hybrid Motor)

  • 전혜정;전우진;이주;카미야 유우시
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.879-881
    • /
    • 2000
  • This paper treats the electromagnet type linear synchronous motor with induction operation. The proposed motor consists of the primary winding energized by variable frequency supplies and the secondary having an additional solid-conductor besides the field finding. The conductor is useful for not only the self-starting but also the damping effect In the synchronous drive. From the investigation by the experiment and the finite element analysis coupled with both electric circuit and motion equation we verify that the proposed motor is effective for practical use.

  • PDF

이중철심을 이용한 병렬연결된 자기결합형 초전도한류기의 전류제한 및 회복특성 (Current Limiting and Recovery Characteristics of Two Magnetically Coupled Type SFCL with Two Coils Connected in Parallel Using Dual Iron Cores)

  • 고석철;임성훈
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.717-722
    • /
    • 2016
  • 본 논문은 고장발생 초기 고장전류의 크기에 따라 피크전류제한 기능을 갖도록 하나의 철심에 기존 1차 코일과 2차 코일이 병렬로 연결된 초전도 소자 1과 추가적인 철심을 사용하여 3차 권선에 초전도 소자 2가 연결된 자기결합형 초전도한류기를 제안하였다. 이중 철심을 이용하여 코일 1과 코일 2간 병렬로 연결한 자기결합형 초전도한류기가 고장발생시 피크전류를 초전도 소자 1만이 분담하는 것을 확인할 수 있었다. 그 이유는 초기 사고전류의 순간적인 요소가 커서 초전도 소자 1이 ?치되어 작동하였으나, 코일 3에 흐르는 전류가 임계전류를 초과하지 않았고, 이로 인해 초전도 소자 2가 ?치되어 작동하지 않았기 때문이다. 사고 시 피크전류를 순차적인 초전도 소자로 제한하기 위해서는 코일 1이 낮은 자기인덕턴스 값을 갖고 있으면서도 코일 2보다 코일 3이 보다 높은 자기인덕턴스 값을 갖도록 설계해야 할 것이다. 또한, 고장 발생 초기 사고전류의 크기를 결정하는 고장조건 중의 하나인 1차 코일과 2차 코일간의 권선비가 0.25일 때 두 SFCL의 전류제한 및 회복특성에 대한 검증을 선로단락실험을 통해 분석되었다. 이 단락실험의 분석결과, 가극결선인 경우가 감극결선한 경우보다도 전류제한 및 회복특성이 더욱 우수함을 확인할 수 있었다.