• Title/Summary/Keyword: Adaptive Supply

Search Result 148, Processing Time 0.023 seconds

Characteristics Improvement of Hydraulic Servosystem by Using Generalized Minimum Variance Adaptive Control (일반화최소분산 적응제어를 이용한 유압 서보계의 특성개선에 관한 연구)

  • 박용호;김기홍;이진걸
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.388-394
    • /
    • 2003
  • Hydraulic system is difficult to obtain a suitable performance due to the nonlinearity load pressure change and system parameter variation. The requirement of control a1gorithm has been complex in order to satisfy the performance. The adaptive control is a control method which is suggested to achieve the control object under the plant characteristics change. In spite of the case that plant characteristics and the degree of variation are difficult to grasp. the adaptive control could keep the characteristics of closed-loop system generally. In this study. a method of combined generalized minimum variance adaptive control (GMVAC) and output error feedback is proposed, in order to solve the problem of non-minimum phase of plant and the vibration and overshoot in initial response. The control performance according to the variation of characteristics of plant is evaluated by changing the supply pressure. The experimental results show the effectiveness of the proposed scheme.

A Variability Analysis on the Flatfish Production and Revenue using Expectation Hypotheses and GARCH Model

  • Yoon, Hyung-Mo;Yoon, Ji-Young
    • The Journal of Fisheries Business Administration
    • /
    • v.48 no.2
    • /
    • pp.1-17
    • /
    • 2017
  • This work studies the variability of flatfish sales revenue. The theoretical analysis draws functions for equilibrium price and quantity using expectation hypotheses. The functions include unpredictable phenomenon with dummy variable and GARCH. The equilibrium function, using adaptive expectation hypothesis, contains the independent variables of supply and demand, while the equilibrium function, embodying rational expectation hypothesis, includes only the independent variables of supply side, because the demand side disappears by the information extraction process theoretically, if economic subjects build the expectation rational. The empirical analysis shows: the variability of flatfish production has a spillover effect on the variability of revenue with the adaptive expectation hypothesis. In the case when the model has a rational expectation hypothesis, the variability of flatfish production has a spillover effect on the revenue (the mean equation of GARCH model). This study indicates that there is the variability in flatfish production and sales revenue, and the spillover effect between them. The result can help to build of the rational system for the fishery income stability.

A Power-Efficient CMOS Adaptive Biasing Operational Transconductance Amplifier

  • Torfifard, Jafar;A'ain, Abu Khari Bin
    • ETRI Journal
    • /
    • v.35 no.2
    • /
    • pp.226-233
    • /
    • 2013
  • This paper presents a two-stage power-efficient class-AB operational transconductance amplifier (OTA) based on an adaptive biasing circuit suited to low-power dissipation and low-voltage operation. The OTA shows significant improvements in driving capability and power dissipation owing to the novel adaptive biasing circuit. The OTA dissipates only $0.4{\mu}W$ from a supply voltage of ${\pm}0.6V$ and exhibits excellent high driving, which results in a slew rate improvement of more than 250 times that of the conventional class-AB amplifier. The design is fabricated using $0.18-{\mu}m$ CMOS technology.

A Novel Adaptive Biasing Scheme for CMOS Op-Amps

  • Kurkure Girish;Dutta Aloke K.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.3
    • /
    • pp.168-172
    • /
    • 2005
  • In this paper, we present a new adaptive biasing scheme for CMOS op-amps. The designed circuit has been used in an Operational Transconductance Amplifier (OTA) with ${\pm}1$ V power supply, and it has improved the positive and negative slew rates from 2.92 V/msec to 1242 V/msec and from 1.56 V/msec to 133 V/msec respectively, while maintaining all the small-signal performance parameter values the same as that without adaptive biasing (as expected), however, there was a marginal decrease of the dynamic range. The most useful features of the proposed circuit are that it uses a very low number of components (thus not creating severe area penalty) and requires only 25 nW of extra stand-by power.

Adaptive Neural PLL for Grid-connected DFIG Synchronization

  • Bechouche, Ali;Abdeslam, Djaffar Ould;Otmane-Cherif, Tahar;Seddiki, Hamid
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.608-620
    • /
    • 2014
  • In this paper, an adaptive neural phase-locked loop (AN-PLL) based on adaptive linear neuron is proposed for grid-connected doubly fed induction generator (DFIG) synchronization. The proposed AN-PLL architecture comprises three stages, namely, the frequency of polluted and distorted grid voltages is tracked online; the grid voltages are filtered, and the voltage vector amplitude is detected; the phase angle is estimated. First, the AN-PLL architecture is implemented and applied to a real three-phase power supply. Thereafter, the performances and robustness of the new AN-PLL under voltage sag and two-phase faults are compared with those of conventional PLL. Finally, an application of the suggested AN-PLL in the grid-connected DFIG-decoupled control strategy is conducted. Experimental results prove the good performances of the new AN-PLL in grid-connected DFIG synchronization.

Supply Chain Planning in Multiplant Network (다중플랜트 네트워크에서의 공급사슬계획)

  • Jeong Jae-Hyeok;Mun Chi-Ung;Kim Jong-Su
    • Proceedings of the Society of Korea Industrial and System Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.203-208
    • /
    • 2002
  • In case of the problems with multiple plants, alternative operation sequence, alternative machine, setup time, and transportation time between plants, we need a robust methodology for the integration of process planning and scheduling in supply chain. The objective of this model is to minimize the tardiness and to maximize the resource utilization. So, we propose a multi-objective model with limited-capacity constraint. To solve this model, we develope an efficient and flexible model using adaptive genetic algorithm(AGA), compared to traditional genetic algorithm(TGA)

  • PDF

Reinforcement leaning based multi-echelon supply chain distribution planning (강화학습 기반의 다단계 공급망 분배계획)

  • Kwon, Ick-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.323-330
    • /
    • 2014
  • Various inventory control theories have tried to modelling and analyzing supply chains by using quantitative methods and characterization of optimal control policies. However, despite of various efforts in this research filed, the existing models cannot afford to be applied to the realistic problems. The most unrealistic assumption for these models is customer demand. Most of previous researches assume that the customer demand is stationary with a known distribution, whereas, in reality, the customer demand is not known a priori and changes over time. In this paper, we propose a reinforcement learning based adaptive echelon base-stock inventory control policy for a multi-stage, serial supply chain with non-stationary customer demand under the service level constraint. Using various simulation experiments, we prove that the proposed inventory control policy can meet the target service level quite well under various experimental environments.

Leakage Detection of Water Distribution System using Adaptive Kalman Filter (적응 칼만필터를 이용한 상수관망의 누수감시 기법)

  • Kim, Seong-Won;Choi, Doo Yong;Bae, Cheol-Ho;Kim, Juhwan
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.10
    • /
    • pp.969-976
    • /
    • 2013
  • Leakage in water distribution system causes social and economic losses by direct water loss into the ground, and additional energy demand for water supply. This research suggests a leak detection model of using adaptive Kalman filtering on real-time data of pipe flow. The proposed model takes into account hourly and daily variations of water demand. In addition, the model's prediction accuracy is improved by automatically calibrating the covariance of noise through innovation sequence. The adaptive Kalman filtering shows more accurate result than the existing Kalman method for virtual sine flow data. Then, the model is applied to data from two real district metered area in JE city. It is expected that the proposed model can be an effective tool for operating water supply system through detecting burst leakage and abnormal water usage.

An Adaptive Equalizer for High-Speed Receiver using a CDR-Assisted All-Digital Jitter Measurement

  • Kim, Jong-Hoon;Lim, Ji-Hoon;Kim, Byungsub;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.155-167
    • /
    • 2015
  • An adaptive equalization scheme based on all-digital jitter measurement is proposed for a continuous time linear equalizer (CTLE) preceding a clock and data recovery (CDR) in a receiver circuit for high-speed serial interface. The optimum equalization coefficient of CTLE is determined during the initial training period based on the measured jitter. The proposed circuit finds automatically the optimum equalization coefficient for CTLE with 20", 30", 40" FR4 channel at the data rate of 5 Gbps. The chip area of the equalizer including the adaptive controller is 0.14 mm2 in a $0.13{\mu}m$ process. The equalizer consumes 12 mW at 1.2 V supply during the normal operation. The adaptive equalizer has been applied to a USB3.0 receiver.

Evaluation of a Self-Adaptive Voltage Control Scheme for Low-Power FPGAs

  • Ishihara, Shota;Xia, Zhengfan;Hariyama, Masanori;Kameyama, Michitaka
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.3
    • /
    • pp.165-175
    • /
    • 2010
  • This paper presents a fine-grain supply-voltage-control scheme for low-power FPGAs. The proposed supply-voltage-control scheme detects the critical path in real time with small overheads by exploiting features of asynchronous architectures. In an FPGA based on the proposed supply-voltage-control scheme, logic blocks on the sub-critical path are autonomously switched to a lower supply voltage to reduce the power consumption without system performance degradation. Moreover, in order to reduce the overheads of level shifters used at the power domain interface, a look-up-table without level shifters is employed. Because of the small overheads of the proposed supply-voltage-control scheme and the power domain interface, the granularity size of the power domain in the proposed FPGA is as fine as a single four-input logic block. The proposed FPGA is fabricated using the e-Shuttle 65 nm CMOS process. Correct operation of the proposed FPGA on the test chip is confirmed.