• Title/Summary/Keyword: Adaptive Setting Zone

Search Result 8, Processing Time 0.021 seconds

Digital Distance Relay with Adaptive Protection Zone (Adaptive보호범위를 가진 송전선로 보호용 디지털 거리계전기)

  • Jung, Chang-Ho;Lee, Jae-Gyu;Jung, Byung-Tae;Ahn, Bok-Shin
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.893-895
    • /
    • 1998
  • This paper presents the adaptive setting method of distance relay under the single line ground fault. The apparent impedance measured at the relaying point and actual impedance is different because of fault resistance and various prefault loading condition. For a resistance earth fault detection, relay setting zone is adaptively changed with measured load current and bus voltage at the relaying point to avoid maloperation.

  • PDF

A Study on Distance Relay of Transmission UPFC Using Artificial Neural Network (신경회로망을 이용한 UPFC가 연계된 송전선로의 거리계전기에 관한 연구)

  • Lee, Jun-Kyong;Park, Jeong-Ho;Lee, Seung-Hyuk;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.37-44
    • /
    • 2004
  • This paper represents a new approach for the protective relay of power transmission lines using a Artificial Neural Network(ANN). A different fault m transmission lines need to be detected classified and located accurately and cleared as fast as possible. However, The protection range of the distance relay is always designed on the basis of fixed settings, and unfortunately these approach do not have the ability to adapt dynamically to the system operating condition. ANN is suitable for the adaptive relaying and the detection of complex faults. The backpropagation algerian based multi-layer protection is utilized for the teaming process. It allows to make control to various protection functions. As expected, the simulation result demonstrate that this approach is useful and satisfactory.

Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication (전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발)

  • Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.

A Study on Operation Zone of Adaptive Distance Relay on Transmission Line Connected UPFC Between Kangjin and Jangheung (UPFC가 연계 된 강진-장흥 송전선로 보호용 거리계전기의 동작특성에 관한 연구)

  • Lee, Seung-Hyuk;Jung, Chang-Ho;Kim, Jin-O;Jung, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.305-307
    • /
    • 2003
  • This paper presents an apparent impedance calculation procedure for distance relaying of transmission line involving FACTS (Flexible AC Transmission System) devices, particularly the UPFC (Unified Power Flow Controller), between Kangjin and Jangheung in Korea. With the changes of UPFC's parameters, the measurement and protective range (trip boundaries) of the adaptive distance relay can also be changed. So, it is the most important part in the field of system protection to analyze the operating characteristic of relaying system. The presence of UPFC significantly affects the trip boundaries which are also adversely affected by fault resistance combined with remote end infeed. This paper presents the apparent impedance calculations and the distance relay setting characteristics for faults involving the UPFC in the KEPCO system.

  • PDF

Analysis of the applicability of parameter estimation methods for a transient storage model (저장대모형의 매개변수 산정을 위한 최적화 기법의 적합성 분석)

  • Noh, Hyoseob;Baek, Donghae;Seo, Il Won
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.10
    • /
    • pp.681-695
    • /
    • 2019
  • A Transient Storage Model (TSM) is one of the most widely used model accounting for complex solute transport in natural river to understanding natural river properties with four TSM key parameters. The TSM parameters are estimated via inverse modeling. Parameter estimation of the TSM is carried out by solving optimization problem about finding best fitted simulation curve with measured curve obtained from tracer test. Several studies have reported uncertainty in parameter estimation from non-convexity of the problem. In this study, we assessed best combination of optimization method and objective function for TSM parameter estimation using Cheong-mi Creek tracer test data. In order to find best optimization setting guaranteeing convergence and speed, Evolutionary Algorithm (EA) based global optimization methods, such as CCE of SCE-UA and MCCE of SP-UCI, and error based objective functions were compared, using Shuffled Complex-Self Adaptive Hybrid EvoLution (SC-SAHEL). Overall results showed that multi-EA SC-SAHEL with Percent Mean Squared Error (PMSE) objective function is the best optimization setting which is fastest and stable method in convergence.

A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance (2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구)

  • 이원석;정창호;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.221-226
    • /
    • 2004
  • Power system has recently used Double-circuit Line and Multi-circuit Line in the industrial development. This has an advantage of system stability and reliability, but the complexity of the system has a disadvantage that makes it difficult to protect the power line. Double-circuit Line has two operation conditions in the Single-circuit operation and Double-circuit operation, so it has mutual impedance. To make it possible for the remaining single-line to operate independently while there is a fault with first line or when maintenance is needed, a trip region for the single-circuit operation should be set in order to set the relay trip region. An optimal trip region for each operation, a different operational conditions for the relay setting should be calculated. In this paper, trip regions of each operation condition have been compared by considering mutual impedance and fault resistance that led to the calculation of fault impedance. Also, as we know that one of the advantages in the distance relay is the back-up protection, we calculated the trip region(Zone-2) in consideration of the mutual impedance.

A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance (2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구)

  • 이원석;정창호;김진오
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.221-221
    • /
    • 2004
  • Power system has recently used Double-circuit Line and Multi-circuit Line in the industrial development. This has an advantage of system stability and reliability, but the complexity of the system has a disadvantage that makes it difficult to protect the power line. Double-circuit Line has two operation conditions in the Single-circuit operation and Double-circuit operation, so it has mutual impedance. To make it possible for the remaining single-line to operate independently while there is a fault with first line or when maintenance is needed, a trip region for the single-circuit operation should be set in order to set the relay trip region. An optimal trip region for each operation, a different operational conditions for the relay setting should be calculated. In this paper, trip regions of each operation condition have been compared by considering mutual impedance and fault resistance that led to the calculation of fault impedance. Also, as we know that one of the advantages in the distance relay is the back-up protection, we calculated the trip region(Zone-2) in consideration of the mutual impedance.

The Immunological Position of Fibroblastic Reticular Cells Derived From Lymph Node Stroma (림프절 스트로마 유래 Fibroblastic Reticular Cell의 면역학적 위치)

  • Jong-Hwan Lee
    • Journal of Life Science
    • /
    • v.34 no.5
    • /
    • pp.356-364
    • /
    • 2024
  • Lymph nodes (LNs) are crucial sites where immune responses are initiated to combat invading pathogens in the body. LNs are organized into distinctive compartments by stromal cells. Stromal cell subsets constitute special niches supporting the trafficking, activation, differentiation, and crosstalk of immune cells in LNs. Fibroblastic reticular cells (FRC) are a type of stromal cell that form the three-dimensional structure networks of the T cell-rich zones in LNs, providing guidance paths for immigrating T lymphocytes. FRCs imprint immune responses by supporting LN architecture, recruiting immune cells, coordinating immune cell crosstalk, and presenting antigens. During inflammation, FRCs exert both spatial and molecular regulation on immune cells through their topological and secretory responses, thereby steering immune responses. Here, we propose a model in which FRCs regulate immune responses through a three-part scheme: setting up, supporting, or suppressing immune responses. FRCs engage in bidirectional interactions that enhance T cell biological efficiency. In addition, FRCs have profound effects on the innate immune response through phagocytosis. Thus, FRCs in LNs act as gatekeepers of immune responses. Overall, this study aims to highlight the emerging roles of FRCs in controlling both innate and adaptive immunity. This collaborative feedback loop mediated by FRCs may help maintain tissue function during inflammatory responses.