• Title/Summary/Keyword: Adaptive Grid

Search Result 221, Processing Time 0.034 seconds

An Analytic Framework to Assess Organizational Resilience

  • Patriarca, Riccardo;Di Gravio, Giulio;Costantino, Francesco;Falegnami, Andrea;Bilotta, Federico
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.265-276
    • /
    • 2018
  • Background: Resilience engineering is a paradigm for safety management that focuses on coping with complexity to achieve success, even considering several conflicting goals. Modern sociotechnical systems have to be resilient to comply with the variability of everyday activities, the tight-coupled and under-specified nature of work, and the nonlinear interactions among agents. At organizational level, resilience can be described as a combination of four cornerstones: monitoring, responding, learning, and anticipating. Methods: Starting from these four categories, this article aims at defining a semiquantitative analytic framework to measure organizational resilience in complex sociotechnical systems, combining the resilience analysis grid and the analytic hierarchy process. Results: This article presents an approach for defining resilience abilities of an organization, creating a structured domain-dependent framework to define a resilience profile at different levels of abstraction, and identifying weaknesses and strengths of the system and potential actions to increase system's adaptive capacity. An illustrative example in an anesthesia department clarifies the outcomes of the approach. Conclusion: The outcome of the resilience analysis grid, i.e., a weighed set of probing questions, can be used in different domains, as a support tool in a wider Safety-II oriented managerial action to bring safety management into the core business of the organization.

Topology-aware Packet Size and Forward Rate for Energy Efficiency and Reliability in Dynamic Wireless Body Area Networks (동적 무선 인체 통신망의 에너지 효율과 신뢰성을 위한 토폴로지 인식 기반 패킷 크기 및 포워딩 비율 결정 방법)

  • Nguyen-Xuan, Sam;Kim, Dongwan;An, Sunshin
    • Journal of Internet Computing and Services
    • /
    • v.15 no.2
    • /
    • pp.9-18
    • /
    • 2014
  • The sensors attached on/in a person are moved since human body frequency changes their activity, therefore in wireless body area networks, nodal mobility and non-line-of-sight condition will impact on performance of networks such as energy efficiency and reliable communication. We then proposed schemes which study on forwarding decisions against frequent change of topology and channel conditions to increase reliable connections and improve energy efficiency. In this work, we control the size of packets, forwarding rate based on ratio of input links and output links at each node. We also robust the network topology by extending the peer to peer IEEE 802.15.4-based. The adaptive topology from chain-based to grid-based can optimal our schemes. The simulation shows that these approaches are not only extending network lifetime to 48.2 percent but also increase around 6.08 percent the packet delivery ratio. The "hot spots" problem is also resolved with this approach.

User experience of responsive web on multi-device environment (멀티 디바이스 환경에서 반응형 웹의 사용자 경험)

  • Kang, Jae-Shin;Lee, Young-Ju
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.465-470
    • /
    • 2018
  • This study investigated how layouts can be arranged to improve the user experience in response to changes in the size of responsive webs in a multi - device environment. The layout elements of the responsive web are largely divided into a header, a main concept image, a main content, a sub-content, and a footer. As the screen becomes smaller, the use of drawers and the menu of the scrolling menus rather than the vertical menus will help improve the user experience. The main concept image should be consistent and not lose readability through the use of system fonts. The main content and the sub content should be prevented from being long in the vertical scroll, and the card UI, the table list and the grid list could be alternatively presented for this purpose. Another problem with vertical scrolling is that the placement of user-selectable menus, such as more or new content corrections, is helpful in improving the user experience.

Hierarchical Voltage Control of a Wind Power Plant Using the Adaptive IQ-V Characteristic of a Doubly-Fed Induction Generator

  • Kim, Jinho;Park, Geon;Seok, Jul-Ki;Lee, Byongjun;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.504-510
    • /
    • 2015
  • Because wind generators (WGs) in a wind power plant (WPP) produce different active powers due to wake effects, the reactive power capability of each WG is different. This paper proposes a hierarchical voltage control scheme for a WPP that uses a WPP controller and WG controller. In the proposed scheme, the WPP controller determines a voltage error signal by using a PI controller and sends it to a doubly-fed induction generator (DFIG). Based on the reactive current-voltage ($I_Q-V$) characteristic of a DFIG, the DFIG injects an appropriate reactive power corresponding to the voltage error signal. To enhance the voltage recovery capability, the gains of the $I_Q-V$ characteristic of a DFIG are modified depending on its reactive current capability so that a DFIG with greater reactive current capability may inject more reactive power. The proposed scheme enables the WPP to recover the voltage at the point of common coupling (PCC) to the nominal value within a short time after a disturbance by using the adaptive $I_Q-V$ characteristics of a DFIG. The performance of the proposed scheme was investigated for a 100 MW WPP consisting of 20 units of 5 MW DFIGs for small and larger disturbances. The results show the proposed scheme successfully recovers the PCC voltage within a short time after a disturbance.

Active Damping of LCL Filter for Three-phase PWM Inverter without Additional Hardware Sensors (추가적인 센서가 필요 없는 3상 PWM 인버터의 LCL 필터 능동댐핑)

  • An, Byoung-Woong;Shin, Hee-Keun;Kim, Hag-Wone;Cho, Kwan-Yuhl;Han, Byoung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.10-17
    • /
    • 2013
  • In this paper, a new active damping method of LCL filter without capacitor voltage sensors is proposed for 3 phase PWM Inverter. Normally, L filter or LCL filter is used as an output filter of grid connected PWM inverter. An LCL filter has more excellent performance than L filter to reduce harmonic current, so the small inductance value can be used. However, the resonance problem in LCL filter is happen due to the zero impedance by the addition of LC branch. To solve the resonance problem, the various active damping method has been proposed so far. Generally, the virtual resistor active damping methods is required to additional hardware sensors for measurement of capacitor voltage and current. In this paper, the new active damping method is proposed without any capacitor voltage or current sensors. In the proposed method, the resonance component of the capacitor voltage of LCL filter can be observed by a simple MRAS(Model Reference Adaptive System) observer without additional hardware sensors, and this component is suppressed by feedforward compensation. The validity of the proposed method is proven by simulation and experiment on the 3-phase PWM inverter system.

An Adaptive Control of Smart Appliances with Peak Shaving Considering EV Penetration (전기자동차 침투율을 고려한 피크 부하 저감용 스마트 기기의 적응적 제어)

  • Haider, Zunaib Maqsood;Malik, Farhan H.;Rafique, M. Kashif;Lee, Soon-Jeong;Kim, Jun-Hyeok;Mehmood, Khawaja Khalid;Khan, Saad Ullah;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.730-737
    • /
    • 2016
  • Electric utilities may face new threats with increase in electric vehicles (EVs) in the personal automobile market. The peak demand will increase which may stress the distribution network equipment. The focus of this paper is on an adaptive control of smart household appliances by using an intelligent load management system (ILMS). The main objectives are to accomplish consumer needs and prevent overloading of power grid. The stress from the network is released by limiting the peak demand of a house when it exceeds a certain point. In the proposed strategy, for each smart appliance, the customers will set its order/rank according to their own preferences and then system will control the household loads intelligently for consumer reliability. The load order can be changed at any time by the customer. The difference between the set and actual value for each load's specific parameter will help the utility to estimate the acceptance of this intelligent load management system by the customers.

Analysis of Multi-Agent-Based Adaptive Droop-Controlled AC Microgrids with PSCAD: Modeling and Simulation

  • Li, Zhongwen;Zang, Chuanzhi;Zeng, Peng;Yu, Haibin;Li, Hepeng;Li, Shuhui
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.455-468
    • /
    • 2015
  • A microgrid (MG) with integrated renewable energy resources can benefit both utility companies and customers. As a result, they are attracting a great deal of attention. The control of a MG is very important for the stable operation of a MG. The droop-control method is popular since it avoids circulating currents among the converters without using any critical communication between them. Traditional droop control methods have the drawback of an inherent trade-off between power sharing and voltage and frequency regulation. An adaptive droop control method is proposed, which can operate in both the island mode and the grid-connected mode. It can also ensure smooth switching between these two modes. Furthermore, the voltage and frequency of a MG can be restored by using the proposed droop controller. Meanwhile, the active power can be dispatched appropriately in both operating modes based on the capacity or running cost of the Distributed Generators (DGs). The global information (such as the average voltage and output active power of the MG and so on) required by the proposed droop control method to restore the voltage and frequency deviations can be acquired distributedly based on the Multi Agent System (MAS). Simulation studies in PSCAD demonstrate the effectiveness of the proposed control method.

Designing fuzzy systems for optimal parameters of TMDs to reduce seismic response of tall buildings

  • Ramezani, Meysam;Bathaei, Akbar;Zahrai, Seyed Mehdi
    • Smart Structures and Systems
    • /
    • v.20 no.1
    • /
    • pp.61-74
    • /
    • 2017
  • One of the most reliable and simplest tools for structural vibration control in civil engineering is Tuned Mass Damper, TMD. Provided that the frequency and damping parameters of these dampers are tuned appropriately, they can reduce the vibrations of the structure through their generated inertia forces, as they vibrate continuously. To achieve the optimal parameters of TMD, many different methods have been provided so far. In old approaches, some formulas have been offered based on simplifying models and their applied loadings while novel procedures need to model structures completely in order to obtain TMD parameters. In this paper, with regard to the nonlinear decision-making of fuzzy systems and their enough ability to cope with different unreliability, a method is proposed. Furthermore, by taking advantage of both old and new methods a fuzzy system is designed to be operational and reduce uncertainties related to models and applied loads. To design fuzzy system, it is required to gain data on structures and optimum parameters of TMDs corresponding to these structures. This information is obtained through modeling MDOF systems with various numbers of stories subjected to far and near field earthquakes. The design of the fuzzy systems is performed by three methods: look-up table, the data space grid-partitioning, and clustering. After that, rule weights of Mamdani fuzzy system using the look-up table are optimized through genetic algorithm and rule weights of Sugeno fuzzy system designed based on grid-partitioning methods and clustering data are optimized through ANFIS (Adaptive Neuro-Fuzzy Inference System). By comparing these methods, it is observed that the fuzzy system technique based on data clustering has an efficient function to predict the optimal parameters of TMDs. In this method, average of errors in estimating frequency and damping ratio is close to zero. Also, standard deviation of frequency errors and damping ratio errors decrease by 78% and 4.1% respectively in comparison with the look-up table method. While, this reductions compared to the grid partitioning method are 2.2% and 1.8% respectively. In this research, TMD parameters are estimated for a 15-degree of freedom structure based on designed fuzzy system and are compared to parameters obtained from the genetic algorithm and empirical relations. The progress up to 1.9% and 2% under far-field earthquakes and 0.4% and 2.2% under near-field earthquakes is obtained in decreasing respectively roof maximum displacement and its RMS ratio through fuzzy system method compared to those obtained by empirical relations.

Adaptive Scheduling in a Service-Based Grid Environment (서비스 기반 그리드 환경에서의 적응적 스케쥴링 기법)

  • Lee, Jong-Hyuk;Chin, Sung-Ho;Lee, Hwa-Min;Lee, Dae-Won;Yu, Heon-Chang
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11a
    • /
    • pp.544-546
    • /
    • 2005
  • 서비스를 기반으로 하지 않은 기존의 그리드 환경에서 병렬 작업 처리를 위한 그리드 어플리케이션은 여래 개의 노드에서 병렬적으로 동일한 작업을 수행하였지만, 웹서비스가 통할된 서비스 기반의 그리드 환경에서는 선형 워크플로우가 여러 개의 서비스 노드에 걸쳐 수행된다. 그러므로 그리드 어플리케이션의 수행 속도 항상을 위해서는 서비스와 서비스 간의 관계를 고려하여야 한다. 그러나 그리드 자원이 각 관리영역마다 이질적이고 그리드 자원의 상태가 동적이어서 그리드 어플리케이션의 성능을 예측하기는 어렵다. 또한 서비스 기반의 그리드 컴퓨팅 환경에서는 사용자의 QoS(Quality of Service)를 보장하여 사용자의 요구 사항을 만족시킬 수 있어야 하기 때문에 사용자 요구에 미달하는 성능 저하와 같은 결함이 발생하였을 경우 이에 대처할 수 있는 방법이 필요하다. 따라서 본 논문에서는 서비스 기반 그리드 컴퓨팅 환경의 특징을 반영하는 워크플로우 관리 시스템의 구조를 설계하고 서비스 수행 성능을 예측하기 위한 서비스 특성에 관한 모델링과 적응적 스케쥴링 기법을 제안한다. 제안하는 적응적 스케쥴링 기법에서는 서비스 간의 관계를 고려하기 위해 최대 흐름 알고리즘(Maximum-Flow Algorithm)을 이용하는 방법과 사용자의 QoS에 대한 수행성능을 보장하기 위해 서비스의 성능 저하 시에 발생하는 결항을 포용할 수 있는 방법을 제안한다.

  • PDF

Effect of Boundary Layer Swirl on Supersonic Jet Instabilities and Thrust

  • Han, Sang-Yeop
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.646-655
    • /
    • 2001
  • This paper reports the effects of nozzle exit boundary layer swirl on the instability modes of underexpanded supersonic jets emerging from plane rectangular nozzles. The effects of boundary layer swirl at the nozzle exit on thrust and mixing of supersonic rectangular jets are also considered. The previous study was performed with a 30°boundary layer swirl (S=0.41) in a plane rectangular nozzle exit. At this study, a 45°boundary layer swirl (S=1.0) is applied in a plane rectangular nozzle exit. A three-dimensional unsteady compressible Reynolds-Averaged Navier-Stokes code with Baldwin-Lomax and Chiens $\kappa$-$\xi$ two-equation turbulence models was used for numerical simulation. A shock adaptive grid system was applied to enhance shock resolution. The nozzle aspect ratio used in this study was 5.0, and the fully-expanded jet Mach number was 1.526. The \"flapping\" and \"pumping\" oscillations were observed in the jets small dimension at frequencies of about 3,900Hz and 7,800Hz, respectively. In the jets large dimension, \"spanwise\" oscillations at the same frequency as the small dimensions \"flapping\" oscillations were captured. As reported before with a 30°nozzle exit boundary layer swirl, the induction of 45°swirl to the nozzle exit boundary layer also strongly enhances jet mixing with the reduction of thrust by 10%.

  • PDF