• 제목/요약/키워드: Actual insolation condition

검색결과 3건 처리시간 0.016초

실제 일사량 조건에서의 최적 MPPT 제어주기 (Optimum MPPT Control Period for Actual Insolation Condition)

  • 류단비;김용중;김효성
    • 전력전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.99-104
    • /
    • 2019
  • Solar power generation systems require maximum power point tracking (MPPT) control to acquire maximum power using inefficient and high-cost PV modules. Most conventional MPPT algorithms are based on the slope-tracking concept. The perturb and observe (P&O) algorithm is a typical slope-tracking method. The two factors that determine the MPPT performance of P&O algorithm are the MPPT control period and the magnitude of the perturbation voltage. The MPPT controller quickly moves to the new maximum power point at insolation change when the perturbation voltage is set to large, and the error of output power will be huge in the steady state even when insolation is not changing. The dynamics of the MPPT controller can be accelerated even though the perturbation voltage is set to small when the MPPT control period is set to short. However, too short MPPT control period does not improve MPPT performance but consumes the MPPT controller resources. Therefore, analyzing the performance of the MPPT controller is necessary for actual insolation conditions in real weather environment to determine the optimum MPPT control period and the magnitude of the perturbation voltage. This study proposes an optimum MPPT control period that maximizes MPPT efficiency by measuring and analyzing actual insolation profiles in typical clear and cloudy weather in central Korea.

학습공간으로 이용되는 대학주변 커피전문점의 조명 실태 및 평가 (The Actual State and Evaluation of Artificial Lighting on Coffee Houses Using Study Place around University)

  • 최솔지;최윤정
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.53-62
    • /
    • 2011
  • This study aimed at suggesting improvement of lighting environment of the coffee house using study place. To this end, a series of field investigation was conducted in four possible target coffee houses around university. The field measurement included measurement of general illuminance and tabletop illuminance, observing illumination condition, and status of artificial lighting. Also, on-site questionnaire survey was administrated to 80 users of field measurement targets about using characteristics of coffee house and user's subjective response on light environment. The results are summarized as follows: (1) According to questionnaire survey, most of users checked 'learning (study and reading)' in 'purpose of coffee house using', and 'slightly dark' was checked most in each subjective response (brightness on general space and on tabletop at daytime/night); (2) as results of measurements on general illuminance and on tabletop illuminance during daytime, only one coffee house was suitable for standard; (3) as results of measurements on illuminance during night, all target coffee houses were not met the standard; (4) as results of uniformity ratios, almost uniformities of general illuminance were not met the standard except one case. The common problems of lighting environment of coffee house were analyzed as lack of daylight illumination e.g. having low amount of sunshine from skylight, un-uniformity of insolation by floor plan and absence of window blind, and un-uniformity of artificial luminous intensity e.g. lack of the number or brightness of artificial lighting, using the indirect lighting, using only local lighting, and non-uniform arrangement of artificial lighting.

Performance Analysis of Double-Glazed Flat Plate Solar Collector with Cu-based Solar Thermal Absorber Surfaces

  • 이정헌;정다솔;남영석
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.157.1-157.1
    • /
    • 2016
  • In this work, we experimentally investigated the solar absorption performance of Cu-based scalable nanostructured surfaces and compared their performance with the conventional TiNOX. We fabricated Cu-based nanostructured surfaces with a controlled chemical oxidation process applicable to a large area or complex geometry. We optimized the process parameters including the chemical compounds, dipping time and process temperature. We conducted both lab-scale and outdoor experiments to characterize the conversion efficiency of each absorber surfaces with single and double glazing setup. Lab-scale experiment was conducted with $50mm{\times}50mm$ absorber sample with 1-sun condition (1kW/m2) using a solar simulator (PEC-L01) with measuring the temperature at the absorber plate, cover glass, air gap and ambient. From the lab-scale experiment, we obtained ${\sim}91^{\circ}C$ and $94^{\circ}C$ for CuO and TiNOX surfaces after 1 hr of solar illumination at single glazing, respectively. To measure the absorber performance at actual operating condition, outdoor experiment was also conducted using $110mm{\times}110mm$ absorber sample. We measured the solar flux with thermopile detector (919P-040-50). From outdoor experiment, we observed ${\sim}123^{\circ}C$ and $131^{\circ}C$ for CuO and TiNOX with 0.6 kW/m2 insolation at double glazing, respectively. We showed that the suggested nanostructured CuO solar absorber has near-equivalent collection efficiency compared with the state-of-the-art TiNOX surfaces even with much simpler manufacturing process that does not require an expensive equipment.

  • PDF