• 제목/요약/키워드: Actual heating energy usage

검색결과 6건 처리시간 0.026초

건축물에너지효율등급 평가프로그램에 의한 공동주택 난방에너지 소요량과 실제 사용량 비교 (Comparing the actual heating energy with calculated energy by the amended standard building energy rating system for apartment buildings)

  • 이아람;김정국;김종훈;정학근;장철용;송규동
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.103-107
    • /
    • 2015
  • Purpose: Since September 1st, 2013, subjects of the evaluation have been expanded, and the evaluation standard has been detailed to enable Building energy rating system for all buildings. Accordingly, the new evaluation program (ECO2) has been developed, and therefore, apartment applied after September 1st, 2013 were evaluated with the new evaluation program. Therefore, this research suggests the improvement plan to figure out reasons for the evaluation result calculation and to calculate the evaluation results close to the actual energy usage by analyzing and comparing primary energy consumption as a result of the new evaluation program (ECO2) and actual heating energy usage on the same building. Method: When comparing evaluation results of the new evaluation program (ECO2) and actual heating energy usage, the tendency was similar but different. Also when comparing seasonally, the tendency was similar, but the different between actual heating energy usage and primary energy consumption during winter is greater than during spring or fall, and when comparing seasonal electric usage, heating alternatives were used through increased electrical usage during winter compared to during spring or fall. Result: Therefore, when evaluating apartment with the new program (ECO2) in the future, evaluation items relevant to the use of heating alternatives should be added, and the modification factor should be added according to the region. Based on the evaluation results of the research and actual energy usage, the Modification factors of the central part and the southern part were calculated respectively as 0.5 and 0.8.

Inverse Model Toolkit을 이용한 리모델링 건축물의 에너지 성능평가 사례 (A Case Study on Energy Performance Analysis of Retrofitted Building Using Inverse Model Toolkit)

  • 권경우;이석주;박준석
    • 설비공학논문집
    • /
    • 제26권8호
    • /
    • pp.394-400
    • /
    • 2014
  • Several models and methods have been developed to verify the improvement of energy performance in retrofit buildings. The verification is important to confirm the effectiveness of new technologies or retrofits. Inverse model toolkit proposed by ASHRAE evaluates the changes of the energy performance of retrofit buildings by using actual energy consumption data. In this study, the inverse model toolkit was used to analyze heating and cooling energy performance of an office building. Analyzed coefficients of correlation of actual energy consumption with estimated energy consumption was above 0.92 and well fitted. It was confirmed that energy consumption of natural gas decreased by 43.4% and also that electricity decreased by 13.8%, after the retrofit of the case building. For the energy usage, cooling energy was increased by 7.4%, heating energy was decreased by 42.3%, hot water and cooking were increased by 3.4%, lighting and electronics were decreased by 19.3%, and the total energy was decreased by 18.9%.

도심 임대아파트의 에너지 및 상수 소비 특성에 관한 연구 (An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment)

  • 서윤규;김주영;홍원화
    • 한국주거학회논문집
    • /
    • 제20권6호
    • /
    • pp.39-46
    • /
    • 2009
  • It has been a serious problem to consume the energy of apartment while increasing to use of heating & cooling System because of residence environmental upgrades. Great attention has been shown to the problem of the rental apartment, so there are few reports of energy consumption about the rental apartment in korea. To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072\;m^2$ per year and typical energy consumption unit was $604.2\;MJ/m^2$ on $74.4\;m^2$ of area and $448.8\;MJ/m^2$ on $105.8\;M^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an typical energy consumption unit standard through this research, apartments should use energy more efficiently.

Cool Tube System 사례를 활용한 환기부하 절감방안 (Ventilation Load Reduction Plan Using Cool Tube System Case)

  • 정민영;박진철;양영권
    • 토지주택연구
    • /
    • 제10권1호
    • /
    • pp.25-32
    • /
    • 2019
  • In this study, the case analysis data on underground temperature are presented. In addition, numerical analysis of the ventilation load reduction plan was derived according to the residence schedule change for the building with cool tube. The research scope and method are as follows. The overall system principle was examined through reviewing the theory of the Cool tube system. Case study and analysis were conducted. Numerical simulation was used to examine the change in energy usage. Also, the change of load energy in case of varying amount of ventilation was derived based on actual building room schedule. When the Cool tube system was applied to the residential buildings, the cooling load was reduced from 3,331 kW to 193 kW, which showed a reduction effect of about 90%.The heating load was reduced from 42,276kW to 32,575kW by 23%.Also, result shows that the cooling load decreased by 24% and the heating load decreased by 66% when the number of ventilation according to the occupancy schedule was applied.

공동주택의 급탕부하 지속시간 및 부하 패턴에 관한 실증연구 (An Empirical Study of Hot Water Supply Patterns and Peak Time in Apartment Housing with District Heating System)

  • 김성민;정광섭;김영일
    • 에너지공학
    • /
    • 제21권4호
    • /
    • pp.435-443
    • /
    • 2012
  • 세계는 원유재고 감소와 국제 정세의 불안정으로 인해 지속적으로 상승하고 있는 유가와 화석연료 사용으로 인한 환경오염에 관심이 고조되고 있다. 국내의 경우 원유를 100% 수입하고 있으며, 사용되고 있는 에너지의 에너지원 중 97%를 수입에 의존하고 있기 때문에 유가 상승에 따른 영향은 더욱 민감하게 나타난다. 국내에 수입되고 유통되는 에너지의 97% 중 1/3 이상이 사무소나 주거용 난방, 급탕 및 취사용으로 사용되고 있다. 이에 따라 정부는 물론 산업체, 연구소 등에서 사무소 및 주거용 에너지 소비패턴으로 인한 경제적인 부담을 줄이고, 고효율 저에너지 기술개발을 통해 소비에너지를 절약함과 동시에 탄소배출을 억제하는 신기술에 대한 연구가 활발하게 이루어지고 있다. 우리나라는 국토가 좁은 반면 인구밀도가 높고, 인구의 도시집중화로 공동주택의 주거비율이 높은 추세이기 때문에 최근 공동주택단지는 초고층화, 대형화가 되고 있으며, 이로 인해 급수 급탕에 대한 사용패턴도 변화하고 있다. 하지만 현재 급수 급탕에 대한 설계 자료는 대부분 외국의 설계 기준과 현장 경험치에 의해 산출된 데이터에 의존하고 있으며, 사용실태에 대한 기초자료가 부족한 실정이며, 이로 인해 급수 급탕 설비 설계 시 과대 또는 과소 설계가 되는 문제가 발생하고 있다. 본 연구에서는 공동주택의 공급자 측 급탕 열 공급환경과 사용자측 열사용량을 측정하여, 급탕부하가 발생하는 시간과 사용 실태 및 패턴을 파악함으로써, 효율적인 공급자 측 급탕설비 설계와 관리를 위한 기초자료를 제시하고자 한다.

부산지역 대형병원 냉방장비의 용량설정 실태조사 (Survey Study of Optimal Cooling Equipment Capacity of the Large Hospitals in Busan City)

  • 이지원;진경일;김세환
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.105-110
    • /
    • 2014
  • The basic factors determining the amount of energy used in hospital buildings are weather conditions and building factors. But the real energy consumer is central plant equipment such as boilers and chillers that produce thermal energy for heating and cooling. Inaccurate decision of the primary equipment's size can cause a high initial-cost, an excessive equipment space, a wasted energy by low operation-efficiency and shortening of the machine's life. In this reason, the decision of optimal size for central plant equipment is very important. There are several factors for the decision such as an operation factor, a factor (equipment factor), piping losses and a simultaneous usage factor applied in the sizing process except a basic cooling load. But there is no standard method for applying those factors. Usually, factors are applied individually by an experience or custom of each engineer. In this study, the authors emphasize the meaning and the problem of those factors, examine them by analyzing factors which were applied to actual practices, and propose the recommendation value of safety, load, operation factors and application methods.