• Title/Summary/Keyword: Activity Monitor

Search Result 367, Processing Time 0.027 seconds

Quality of Sleep and Heart Rate Variability by Physical Activity in High School Students (고등학생의 신체활동에 따른 수면의 질 및 심박변이도)

  • Park, Min Sun;Choi, Mona;Lee, Hyangkyu;Lee, Myoungho
    • Child Health Nursing Research
    • /
    • v.21 no.3
    • /
    • pp.195-203
    • /
    • 2015
  • Purpose: This study was done to investigate quality of sleep and heart rate variability by the physical activity in high school students. Methods: A survey that measures physical activity and quality of sleep was distributed to 118 students at Y High School. Heart rate variability was obtained using the LXC3203 heart rate monitor. The data of 105 students were analyzed using descriptive statistics, t-test, x2-test, and ANOVA with $Scheff{\acute{e}}$ test. Results: Boys and students with part-time jobs had significantly higher physical activity. The quality of sleep was significantly high when the students were non-smokers, felt healthy, happy, less stressed, and satisfied with their school lives. Mean heart rate was significantly higher among girls, and standard deviation from normal to normal R-R intervals were high in boys. Physical activity had no significant relationships with quality of sleep and heart rate variability. Conclusions: Physical activity should be encouraged for high school students, especially for girls. An experimental study with different intensity and time of physical activity is recommended to examine the relationships with quality of sleep and heart rate variability in the future.

Differential Expression of Arabidopsis Cab Promoters in Organs of Transformed Tobacco Plants (형질전환된 담배식물체의 기관에 따른 Arabidopsis Cab Promoter의 차별적 실험)

  • 홍순조
    • Journal of Plant Biology
    • /
    • v.35 no.3
    • /
    • pp.229-235
    • /
    • 1992
  • Differential expression of the three chlorophyll afb binding (cab) protein gene (cabl, cab2, and cab3) promoters of Arabidopsis thaliana was studied in tobacco plants transformed with cab-CAT (chloramphenicol acetyltransferase) translational fusions. CAT activity was measured to monitor the activities of the cab promoters. The activity of cabi promoter was higher than the other two in transformed tobacco leaves and also in calli and shoots derived from the leaves. Their activities were organ-specific and were the lowest in roots, medium in stems, and the highest in leaves. The relative activity of cabi promoter in stems comparing to it activity in leaves was, however, much higher than the values of cab2 and cab3. When the cab promoter activity was expressed as CAT activity per unit chlorophyll instead of CAT activity per unit protein, the relative cab] promoter activity (stem/leaf) became almost unity. This result suggests that cab2 and cab3 show photosynthetic organ-specificity but cabl does not. Similar result was obtained in the differentiation process of stems and leaves from shoots derived from the transgenic tobacco leaves.leaves.

  • PDF

Development of device for cat healthcare monitoring using Smartphone

  • Nam, Heung Sik;Lee, Moon Joo;Kim, Geon A
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.11
    • /
    • pp.157-163
    • /
    • 2022
  • In this paper, we propose to develop a Bluetooth Health Device Profile (HDP)-based smartphone system to utilize it for early detection of urinary tracts diseases that occur a lot in cats. Therefore, based on Bluetooth HDP, we developed a device and mobile application system (Mycatner®) that can monitor cat activity, toilet usage, urinary disease, and health status, and evaluated its availability to monitor cat health status. The specific feature of this system is that it can measure the number of cat urination frequencies to identify abnormal conditions suspected of urinary tract diseases early, and second, it can be tested with urine test paper and shared with animal hospitals, reducing time and cost. As a result, it is evaluated that the developed device capable of wireless monitoring the urinary system health status of cats is the first in our knowledge.

Evaluation of Radioactive Stack Air Effluents from the Advanced Fuel Science Building at KAERI (한국원자력연구원 새빛연료과학동 굴뚝방출 방사능 평가)

  • Chang, S.Y.;Kim, B.H.
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.3
    • /
    • pp.121-126
    • /
    • 2008
  • Radioactivities of the stack air effluents from the Advance Fuel Science Building (AFSB) at KAERI have been investigated and evaluated. In this AFSB, nuclear fuels for the HANARO research reactor have been fabricated and the advanced nuclear fuels have been studied. A stack air monitoring system has been continuously operating to monitor the stack air effluents from the facility to protect the environment. As the results of the periodical radioactivity measurement and both the gamma and alpha spectrometry for the millipore filters taken from the stack air monitor from January until March 2008, a trace amount of primordial $^{40}K$ and the short-lived decay products of natural borne $^{222}Rn$ and $^{220}Rn$ have been detected. However, the radioactivities have rapidly decayed to the level below the Minimum Detectable Activity (MDA) of the counting system. Therefore, it was evaluated that no uranium isotopes have been released to the atmosphere from the stack of the AFSB at KAERI.

A study on monitoring the subsidence of the gas utilities using GPS techniques (GPS를 이용한 가스설비 침하 감시 기술 연구)

  • Cho S.H.;Jeon K.S.;Park P.H.;Park J.U.;Joh J.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.2 s.7
    • /
    • pp.53-61
    • /
    • 1999
  • The safety of gas utilities is intimidated by many causes. Among them, subsidence is a dominant cause to decrease the safety of gas utilities. So it is very important to monitor the displacement of subsidence. The purpose of this study is to on-line monitor the subsidence of gas utilities using Static GPS(Global Positioning System)technique. Static GPS technique, which is one of various GPS techniques and originally applied to monitor the crustal activity, was applied for two gas station in Korea Gas Corporation. Prior to applying this technique to the field, i.e, gas station, a preliminary test was peformed to confirm the accuracy of this technique. As a result, it was proved that this technique can measure the displacement of gas utilities three dimensionally by sub-millimeter. After getting confirmation of GPS technique, we applied this technique for two gas stations and monitored the amount of subsidence during 5 months. As a result of field test, we can conclude that the gas stations was subsiding several millimeters in a year.

  • PDF

Monitoring Techniques for Active Volcanoes (활화산의 감시 기법에 대한 연구)

  • Yun, Sung-Hyo;Lee, Jeong-Hyun;Chang, Cheol-Woo
    • The Journal of the Petrological Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.119-138
    • /
    • 2014
  • There are various ways to monitor active volcanoes, such as the method of observing the activity of a volcano with the naked eye, the method of referring to the past eruptive history based on the historic records and the method of monitoring volcanoes by using observation equipment. The most basic method from the observation equipment-using methods to monitor volcanoes is seismic monitoring. In addition to this, the ways to monitor volcanoes are as follows: resonance observation which may be effective to remove artificial noises from the seismic activities that are recorded in the seismograph, ground deformation by using precision leveling, electronic distance measurement, tiltmeter, GPS, and InSAR observation method, volcanic gas monitoring, hydrologic and meteorological monitoring, and other geophysical monitoring methods. These monitoring methods can make volcanic activities effectively monitored, determine the behavior of magmas in magma chambers and help predict the future volcanic eruptions more accurately and early warning, thus, minimize and mitigate the damage of volcanic hazards.

Implementation and evaluation of the BCG measurement system for non-constrained health monitoring (무구속 건강모니터링을 위한 심탄도 계측 시스템 구현 및 평가)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • This research proposes measuring of BCG(ballistocardiogram) to monitor heart activities in a non-constrained environment, at home or work. Unlike with ECG, measuring BCG does not require the attachment of leads on the subject's body and allows signal measuring in a non-constrained state. It enables effective long-term monitoring of cardiac conditions. In this study a chair type BCG measurement system to continuous monitor the activity of the heart is implemented. The instrument consists of upper petal and ready for press of chair load cell sensor is attached to measure the change of the object's weight. In order to extract the output ballistic signal from the weight and force sensor signals. Beside the signal processing circuit for the digital conversion, the ballistic signal is detected using DAQ equipment. Signal processing algorithm including wavelet transforms for noise cancellation, template matching for normalization and peak detection in BCG is developed. ECG and BCG were concurrently measured to evaluate the performance of the system, and comparing the characteristics of the two signals verified the possibility of the system in non-constrained and nonconscious health monitoring.

Patch Type Body Temperature Measurement System for Ubiquitous Healthcare (U-헬스케어를 위한 패치형 체온 측정 시스템)

  • Kim, Hyun-Joong;Yang, Hyun-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1628-1634
    • /
    • 2011
  • With the advancement of ubiquitous computing technology, u-Healthcare (i.e. ubiquitous health care), is regarded as a key application for information society, which provides health management service at anytime in anywhere. To implement U-Healthcare system, it is essential to monitor stable biological information in daily life. In this paper, we proposed a small size, light weight, patch type real time temperature monitoring system based on wireless sensor network (WSN) technology to monitor patients' body temperature without any inconvenience of activity.

The Development of VOC Measurement System Uging PCA & ANN (PCA와 ANN을 이용한 VOC 측정기기 개발)

  • Lee Jang-Hoon;Kwon Hyuk-Ku;Park Seung Ho;Kim Dong-Jin;Hong Chol-Ho
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.2
    • /
    • pp.161-167
    • /
    • 2004
  • Air quality monitoring is a primary activity for industrial and social environment. The government identifies the pollutants that each industry must monitor. Especially, the VOCs (Volatile Organic Compounds), which are very harmful to human body and environment atmosphere, should be controlled under the government policy. However, the VOCs, which have not been confirmed in emission sources are very difficult to monitor. It is needed to develop the monitoring system that allow the continuous and in situ measurement of VOCs mixture in different environmental matrices. Gas chromatography and mass spectrometry are the most prevalent current techniques among those available for the analysis of VOCs. But, they need a large size analytical instrument, which costs a great deal for purchase and operation. In addition, it has some limitations for realtime environmental monitoring such as location problems and slow processing time. Recently, several companies have commercialized a portable VOCs measurement systems, which cannot classify various kinds of VOCs but total quantities. We have developed a VOCs measurement system, which recognizes various kinds and quantities of VOCs, such as benzene, toluene, and xylene (BTX). Also, it can be used as a stand- alone type and/or fixed type in the vehicle with rack for real -time environmental monitoring.

Practical Application Method of Holter Monitoring with Unipolar Precordial Chest Lead in Dog (개에서 단극 심장 앞 흉부유도를 이용한 Holter monitoring의 임상적 적용 방법)

  • Jung, Yun-Chan;Bhang, Dong-Ha;Kim, You-Seok;Hwang, Cheol-Yong;Youn, Hwa-Young
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.128-132
    • /
    • 2011
  • Holter monitoring has been recognized as an useful noninvasive instrument for monitoring the cardiac electrical activity over 24 to 48 hours. Because the surface electrocardiogram (ECG) is recorded only for several seconds to minutes, it often misses or underestimates the underlying arrhythmia. The surface ECG is also easily influenced by depolarization potentials from skeletal muscle by the movement of patient (especially muscle tremor). However, holter monitoring is less affected by such factors. There has been no precedential report in veterinary medicine applying digital holter monitor with unipolar precordial chest lead using 4 electrodes. This article describes its clinical indications, equipment and technical application method in dogs.