• Title/Summary/Keyword: Active unit

Search Result 739, Processing Time 0.029 seconds

Investigation of Delirium Occurrence and Intervention Status in Intensive Care Unit at a Hospital and Perception of Delirium by Medical Staff (일 종합병원 중환자실의 섬망 발생 및 중재 현황과 의료진의 섬망 인식 조사)

  • Kang, Yi-Seul;Kim, Soon-Hee;Lee, Min-Jeoung;Lee, Hyo-Jin;Lim, Oak-Bun;Hong, Sang-Bum;Choi, Hye-Ran
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.1
    • /
    • pp.71-86
    • /
    • 2023
  • Purpose : This study aims to investigate the status of delirium intervention in adult intensive care unit (ICU) patients and the perception of this delirium by medical staff. Methods : This retrospective study involves 185 patients, whereas, a descriptive survey is conducted with 197 medical staff members. Results : The delirium group includes 100 patients (54.1%). The incidence of delirium is 64.9% in the medical ICU, 65.9% in the surgical ICU, 42.4% in the neuro ICU, and 46.5% in the cardiac ICU. The percentages of delirium prevention intervention differs between the two groups: 65.0% in the delirium group and 95.3% in the non-delirium group. The medical staff recognize that delirium is a common problem in the ICU (100.0%) and requires active medical intervention (98.5%). Conclusion : The length of stay at the ICU is longer in the delirium group than in the non-delirium group. It is necessary to standardize delirium prevention and treatment protocols to be equally applicable to all ICU patients.

High Resolution Hydroacoustic Investigation in Shallow Water for the Engineering Design of Railroad Bridge (철도교량 설계 지반조사를 위한 고분해능 수면 탄성파반사법의 응용 사례)

  • ;Swoboda Ulrich
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.231-238
    • /
    • 2001
  • To investigate the underground structure of shallow water, Han-river near Yangsou-Ri, high resolution hydroacoustic measurements were carried out for the engineering design of railroad bridge. The acoustic source was a Boomer with an energy of 90 to 280J and in a frequency range up to about 16KHz. The reflected signals were received by using both traditional hydrophones(passive element) and a specially devised receiver unit(active element) mainly composed of piezofilms and preamplifier. They are connected to the "SUMMIT" data acquisition system(DMT-GeoTec company), where the sampling interval was set to 1/32㎳. The source position was continuously monitored by a precision DGPS system whose positioning accuracy was on the order of loom. For the quality control purposes, two different source-receiver geometries were taken. That is to say, the measurements were repeated along the profile everytime depending on the different source energy(175J, 280J), the receiving elements(passive, active) and two different source-receiver geometries. It was shown that the data resolution derived from a proper arrangement with the active hydrophone could be greatly enhanced and hence the corresponding profile section caused by the regular data processing system "FOCUS" accounted excellently for the underground formation below the shallow water.w the shallow water.

  • PDF

A Design of Lowpass Active Filter for ADLS Tx/Rx Stage (ADSL 송수신단용 저역통과 능동필터 설계)

  • Lee Geun-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.1
    • /
    • pp.38-42
    • /
    • 2005
  • CMOS analog lowpass filters using speech signal bandwidth for a Asymmetrical Digital Subscriver Line(ADSL) modem are presented. Designed active lowpass filters are composed of the CMOS complementary high-swing cascode stage which can increase transconductance of an active element. As a result, their cutoff frequency are 138kHz and 1,100kHz respectively. A low-voltage high-swing cascode integrator which improved on a gain and unit gain frequency used to design the filters. The designed filters are verified by HSPICE simulation with the $0.251{\mu}m\;CMOS\;n-well$ Parameter and a single 2.5V power supply.

Active Alignment and Performance Evaluation of Micro Hybrid Lens for Small Form Factor Optical Pickup (초소형 광 픽업용 하이브리드 렌즈의 능동 정렬 및 성능평가)

  • Kang Sung-Mook;Lee Jin-Eui;Cho Eun-Hyoung;Sohn Jin-Seung;Park No-Cheol;Park Young-Pil
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.154-159
    • /
    • 2005
  • The next generation of optical storage systems requires higher numerical aperture (NA) objective lenses and shorter wavelength laser in order to improve the unit areal density. A blu-ray technology satisfies a miniaturization and a high capacity which are the requirements of the portable device. In this paper, we analyze the optical performance of hybrid micro lens and do active alignment. The hybrid micro lens is manufactured by using a wafer based fabrication technology. Optical components of hybrid micro lens are evaluated. The measurement of the optical power, the spot size and the wavefront error awe performed to evaluate the hybrid micro lens with NA 0.85. Using the measured data, we estimate if the performance of hybrid micro lens corresponds to the designed performance. After the performance of hybrid micro lens is evaluated, the integrated optical pickup and the hybrid micro lens are assembled by active alignment using UV curing and the optical performance of SFFOP is satisfied with BD specifications.

  • PDF

Multi-Channel Active Noise Control System Designs using Fuzzy Logic Stabilized Algorithms (퍼지논리 안정화알고리즘을 이용한 다중채널 능동소음제어시스템)

  • Ahn, Dong-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3647-3653
    • /
    • 2012
  • In active noise control filter, IIR filter structure which used for control filter assures the stability property. The stability characteristics of IIR filter structure is mainly determined by pole location of control filter within unit disc, so stable selection of the value of control filter coefficient is very important. In this paper, we proposed novel adaptive stabilized Filtered_U LMS algorithms with IIR filter structure which has better convergence speed and less computational burden than conventional FIR structures, for multi-channel active noise control with vehicle enclosure signal case. For better convergence speed in adaptive algorithms, fuzzy LMS algorithms where convergence coefficient computed by a fuzzy PI type controller was proposed.

Active Alignment and Performance Evaluation of Micro Hybrid Lens for Small Form Factor Optical Pickup (초소형 광 픽업용 하이브리드 렌즈의 능동 정렬 및 성능평가)

  • Kang, Sung-Mook;Lee, Jin-Eui;Cho, Eun-Hyoung;Sohn, Jin-Seung;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.79-84
    • /
    • 2006
  • The next generation of optical storage systems requires higher numerical aperture(NA) objective lenses and shorter wavelength laser in order to improve the unit areal density. A blu-ray technology satisfies a miniaturization and a high capacity which are the requirements of the portable device. In this paper, we analyze the optical performance of hybrid micro lens and do active alignment. The hybrid micro lens is manufactured by using a wafer based fabrication technology. Optical components of hybrid micro lens are evaluated. The measurement of the optical power, the spot size and the wavefront error are performed to evaluate the hybrid micro lens with NA 0.85. Using the measured data, we estimate if the performance of hybrid micro lens corresponds to the designed performance. After the performance of hybrid micro lens is evaluated. the integrated optical pickup and the hybrid micro lens are assembled by active alignment using UV curing and the optical performance of SFFOP is satisfied with BD specifications.

  • PDF

Vibration control of small horizontal axis wind turbine blade with shape memory alloy

  • Mouleeswaran, Senthil Kumar;Mani, Yuvaraja;Keerthivasan, P.;Veeraragu, Jagadeesh
    • Smart Structures and Systems
    • /
    • v.21 no.3
    • /
    • pp.257-262
    • /
    • 2018
  • Vibrational problems in the domestic Small Horizontal Axis Wind Turbines (SHAWT) are due to flap wise vibrations caused by varying wind velocities acting perpendicular to its blade surface. It has been reported that monitoring the structural health of the turbine blades requires special attention as they are key elements of a wind power generation, and account for 15-20% of the total turbine cost. If this vibration problem is taken care, the SHAWT can be made as commercial success. In this work, Shape Memory Alloy (SMA) wires made of Nitinol (Ni-Ti) alloys are embedded into the Glass Fibre Reinforced Polymer (GFRP) wind turbine blade in order to reduce the flapwise vibrations. Experimental study of Nitinol (Ni-Ti) wire characteristics has been done and relationship between different parameters like current, displacement, time and temperature has been established. When the wind turbine blades are subjected to varying wind velocity, flapwise vibration occurs which has to be controlled continuously, otherwise the blade will be damaged due to the resonance. Therefore, in order to control these flapwise vibrations actively, a non-linear current controller unit was developed and fabricated, which provides actuation force required for active vibration control in smart blade. Experimental analysis was performed on conventional GFRP and smart blade, depicted a 20% increase in natural frequency and 20% reduction in amplitude of vibration. With addition of active vibration control unit, the smart blade showed 61% reduction in amplitude of vibration.

Development of Facial Emotion Recognition System Based on Optimization of HMM Structure by using Harmony Search Algorithm (Harmony Search 알고리즘 기반 HMM 구조 최적화에 의한 얼굴 정서 인식 시스템 개발)

  • Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.3
    • /
    • pp.395-400
    • /
    • 2011
  • In this paper, we propose an study of the facial emotion recognition considering the dynamical variation of emotional state in facial image sequences. The proposed system consists of two main step: facial image based emotional feature extraction and emotional state classification/recognition. At first, we propose a method for extracting and analyzing the emotional feature region using a combination of Active Shape Model (ASM) and Facial Action Units (FAUs). And then, it is proposed that emotional state classification and recognition method based on Hidden Markov Model (HMM) type of dynamic Bayesian network. Also, we adopt a Harmony Search (HS) algorithm based heuristic optimization procedure in a parameter learning of HMM in order to classify the emotional state more accurately. By using all these methods, we construct the emotion recognition system based on variations of the dynamic facial image sequence and make an attempt at improvement of the recognition performance.

The Effect of Passive Lung Expansion Technique and Active Respiration Enhancement Technique on Lung Function in Healthy Adults (수동폐확장과 능동호흡강화 기법이 건강한 성인 폐기능에 미치는 영향)

  • Lee, Donggin;Lee, Yeonseop
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.155-161
    • /
    • 2020
  • Purpose : This study was conducted to investigate the effect of positive active pressure technique and active breathing technique on lung function in healthy adults. Methods : In this study, the passive lung expansion technique and active respiration enhancement technique using an air mask bag unit were conducted in 30 normal adults to observe changes in pulmonary function with forced vital capacity (FVC), Forced expiratory volume at one second (FEV1). In order to observe the change in the level of respiratory function, we would like to investigate the peak expiratory flow (PEF) and the forced expiratory flow (FEF 25-75 %). Results : As a result of this study, there was no significant difference in comparison between the passive lung expansion technique and the active breathing enhancement technique (p>.05). The passive lung expansion technique effectively increased the effortful expiratory volume and the median expiratory flow rate of 1 second (p<.05). And the passive lung expansion technique effectively increased the effortless lung capacity and the maximum expiration flow rate (p<.05). Conclusion : The passive lung expansion technique effectively increases the range of motion of the lungs and chest cages, intrathoracic pressure, and elasticity of the lungs, and the active breathing technique increases the muscle functions such as the diaphragm and the biceps muscles. It is expected that it will be able to selectively improve the respiratory function of patients with respiratory diseases or functional limitations as it is found to be effective.

Management of Tuberculosis Outbreak in a Small Military Unit Following the Korean National Guideline (국내 결핵관리지침에 따른 군내 결핵 집단발병 관리 사례 보고)

  • Ji, Sang Hoon;Kim, Hee Jin;Choi, Chang Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.1
    • /
    • pp.5-10
    • /
    • 2007
  • Background: Korean national guidelines for examining contacts with active pulmonary tuberculosis (TB) are a tuberculin skin test (TST) and chest radiographs. The treatment of a latent TB infection as performed only in those younger than six years of age who test positive for TST. Although there is a high incidence of active TB in young Korean soldiers, the current national guidelines for controlling contacts with active TB in soldiers are insufficient. This study highlights the problems with the Korean guidelines for controlling a TB outbreak in a small military unit. Material and Methods: In December of 2005, there was a tuberculosis outbreak in a military unit with a total of 464 soldiers in Kyung Gi province. The chest radiographs were taken of all the soldiers, and TST were carried out on 408 candidates. Results: In the first screening of the chest radiographs, two active TB patients were detected. By August of 2006, four additional cases were detected, making a total of six cases after the outbreak. All the patients showed active pulmonary TB or TB pleuritis. When the results of TST in the close contacts and non-close contacts were compared, there was a significant difference in the absolute size of the induration($9.70{\pm}7.50mm$ vs. $6.26{\pm}7.02mm$, p<0.001) as well as the ratio of patients showing an induration > 10mm (50.0% vs. 32.0%, p<0.001) and 15mm (33.2% vs. 20.9%, p= 0.005). Conclusion: Although the national guidelines for managing a TB outbreak in a military unit were followed, there were continuous instances of new active TB cases. This highlights the need for new guidelines to prevent the spread of TB.