A Brief Study on Smoke Suppression Effects by Sprinkler Spray System (스프링클러설비에 의한 연기제어효과 고찰)

  • Cha, Jong-Ho;Yoon, Myung-O;Choi, Chun-Bae;Lee, Sun-Kyung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.560-565
    • /
    • 2006
  • Sprinkler system is the most effective fire suppression with high confidence among active fire extinguishing systems. According to the installation of the related system on buildings, more separation area of fire protection can be considered to the fire protection design, and also lower differential pressure (12.5 Pascal) is permitted on lobby of fire escape stairs and emergency elevator (25 Pascal shall be considered for none sprinkler system) with economic factor. More details will be handled on the related studies.

  • PDF

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.

A Study on Improvement of Fire-fighter's outfits and fire-fighting scenarios for effective water-extinguishment on ship (효과적인 선상 수소화를 위한 소방원 장구 및 화재진압 시나리오 개선에 관한 연구)

  • Sim, Hyo-Sang;Park, Young-Soo;Ha, Won-Jae
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.100-102
    • /
    • 2016
  • Every crew are in great peril that they should put out a fire on board in person due to a property of ship isolated. Accordingly, it is essential to verify whether the fire-fighter's outfits and fire-fighting scenarios in accordance with present regulations are safe and effective actually. As a result of comparison between shore fire-fighter's outfits and fire-fighting scenarios and those on ship and statistics calculation of the place and frequency of the fire of actual ship, present limitations of fire suppression system and fire-fighter's outfits were proved. In addition, derive the distance to the place on ship that has highest frequency of fire occurrence from examining actual ship's drawings according to their description and size. Finally from experiments in more experimental groups by changing numbers of actual fire-fighters and environment and conduction of survey of a number of crew in active service on ship, the most effective fire-fighter's outfits system and fire-fighting scenarios will be derived.

  • PDF

Forest Fire Damage Analysis Using Satellite Images (위성영상을 이용한 산불재해 분석)

  • Kang, Joon-Mook;Zhang, Chuan;Park, Joon-Kyu;Kim, Min-Gyu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.21-28
    • /
    • 2010
  • Forest fire is one of the main factor disturbing the environment of forest, and it influences greatly the structure and function on forest. The process of vegetation recovery could be decided according to the extent of the damage. It is required a lot of man powers and budgets to understand born severity and process of vegetation rehabilitation at the damaged area after large-fire. However, the analysis of born severity in the forest area using satellite imagery can acquire rapidly information and more objective results remotely in the large-fire area. In this study, the space sensors have been used to map area burned, assess characteristics of active fires. For classifying fire damaged area and analyzing severity of Cheongyang-Yesan fire in 2002, in this paper we use pre- and post-fire imagery from the Landsat TM and ETM+ to compute the evaluate large-scale patterns of burn severity, use the digital stock map to calculate the damaged condition about the forest fires damaged regions and use the NDVI to monitoring the situation of the revegetation.

Evaluation of the Closed-type Sprinkler Head Activation Time (밀폐형 스프링클러 헤드의 동작시간 평가)

  • Moon-Hak, Jee;Sung-Yull, Hong
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2004
  • As a predominant active fire suppression method, closed-type sprinkler systems are used for the purpose of fire control and suppression at the nuclear power plants as well as the industrial facilities. It goes without saying that the proper selection of the system guarantees the adequate actuation of the thermal device. Consequently, the appropriate evaluation should be executed for the thermal behavior with the theoretical and empirical approach. For this purpose, the comparison of activation time for the fusible-link type sprinkler head with the simplified fire case and t-square fire growth case was evaluated. At this paper, the comparison output was presented with the tendency of thermal behavior. In addition, we issued some technical comments for the most appropriate equation in case of the estimation of the sprinkler head activation time. We also raised some idea that should be incorporated for the usage of the t-square equation for the realistic application in the field of the performance-base fire protection approach.

Performance Evaluation of Search Robot Prototypes for Special Disaster Areas (특수재난지역 정찰로봇 시제품의 성능평가연구)

  • Kwark, Jihyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.109-118
    • /
    • 2015
  • Recently, three kinds of search robot prototypes were developed to assume the role of fire fighters for search and rescue missions in special disaster areas with high heat, smoke, toxic gases, or radioactivity. To accomplish search missions, these robots should be able to endure heat, overcome various obstacles, suppress fires, and see through dense smoke. This study investigated the heat resistance, practicality, and fire fighting capacity of these robots. The results show that the small and middle-sized robots were resistant to surrounding temperatures of $100{\sim}200^{\circ}C$, and the fire-fighter-riding robot could endure up to $500^{\circ}C$ for half an hour. The fire-fighter-riding robot showed excellent extinguishing performance on an A-10 class fire model, which was extinguished within 3 min. The robots also showed various capacities for overcoming obstacles and are expected to play an active role in various special disaster areas.

Effects of job satisfaction and spouse support on parenting stress in female fire fighters with preschool-aged children (취학 전 자녀를 둔 여성소방공무원의 직무만족도와 배우자 지지가 양육스트레스에 미치는 영향)

  • Che, Ga-Young;Baek, Mi-Lye
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.1
    • /
    • pp.87-98
    • /
    • 2015
  • Purpose: Job satisfaction, spouse support, parenting stress, and the factors that influence parenting stress in female fire fighters with preschool-aged children were examined. Methods: Data were collected from 180 female fire fighters who worked at the fire station from June to July 2013 and had preschool-aged children. Data were analyzed using SPSS WIN 21.0. Results: Average job satisfaction was 2.81, spouse support was 3.54, and parenting stress was 3.61. Parenting stress was negatively correlated with spouse support and job satisfaction. Job satisfaction and spouse support were positively correlated. Factors influencing parenting stress included employment period (${\beta}$=0.093, p <.05), a husband who is not a fire fighter (${\beta}$=-8.971, p <.05), having three children (${\beta}$=27.395, p <.05), delegating childcare to relatives (${\beta}$=9.605, p <.05), income (${\beta}$=-0.920, p <.05), and spouse support (${\beta}$=-0.589, p <.05). Conclusion: To reduce parenting stress and increase job satisfaction, female fire fighters with preschool-aged children should be assigned to stable administrative work instead of stressful on-site work. Husbands who are fire fighters should take advantage of paternity leave, implemented by the Ministry of Public Safety and Security, to increase their active participation in parenting.

Trend Analysis of Wildland Fires and Their Impacts on Atmospheric Environment over East Asia

  • Shin, Sung-Kyun;Lee, Kwon-Ho
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.22-31
    • /
    • 2016
  • Active fire products from Moderate Resolution Imaging Spectroradiometer (MODIS) satellite observation during the 16 years from 2000-2015 were analyzed to estimate spatial and temporal variations of wildland fires over East Asia (region of interest: $20^{\circ}N-55^{\circ}N$, $100^{\circ}E-150^{\circ}E$). GLOBCOVER 2009 land cover data were also used to investigate the trend in wildfire occurrence with respect to each land cover type. Statistical analysis showed that the highest number of wildland fires occurred in the evergreen and vegetation covered areas, and strong seasonal variations were found in these areas. Total numbers of fires were 283,683 and 202,543, respectively. In particular, the wildland fires in croplands occurred mainly during summer season and distinguishable increasing trends were found. The correlations between number of wildland fires and air pollutants, such as black carbon, organic matter, and carbon monoxide, were also calculated in order to investigate the intensity of the air pollution caused by the wildland fires. Positive correlation between total column carbon monoxide contents and the occurrence of wildland fire was found. In addition, this correlation was higher than the correlation between fire occurrence and black carbon or organic matter. These results indicate that a significant amount of carbon monoxide originated from the wildland fires and influenced the regional atmospheric environment in East Asia.

Developments of Fire-Resistant Wooden Structural Components and Those Applications to Mid- to High-Rise Buildings in Japan

  • Hanai, Atsunari;Nakai, Masayoshi;Matsuzaki, Hiroyuki;Ohashi, Hirokazu
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.3
    • /
    • pp.221-233
    • /
    • 2020
  • Based on past experiences of natural disasters and fires in Japan, it is stipulated by law that fire-resistant buildings larger than a certain size should be unique in the world. Recent interest in global environmental issues has led to the active introduction of wooden buildings also in Japan, and it is expected that wooden buildings will become larger and higher in size. This paper introduces the background of the development of fire-resistant laminated timber with a "Self-Charring-Stop layer", the contents of this development including other related developments, and the application of these technologies. In addition, towards the realization of much larger and higher buildings in the future, the current problems and issues to be solved are set and the necessity of the future technological development is described. Finally, a conceptual model of wooden high-rise building is proposed, which will be able to be constructed in 2025 by the further technological development.

Comparative study on characteristics of domestic and foreign civil anti-disaster organizations (국내외 민간 방재조직의 특성에 관한 비교 분석)

  • Kim, Bo-Kyun;Lee, Jeong-Hyeok;Chae, Jong-Sik
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.127-143
    • /
    • 2021
  • Purpose: The purpose of the study is to investigate the actual state of activity on domestic and foreign civil anti-disaster organizations, related suggestions, and development plans. Methods: This study used the documentary survey research method and the technical approach method. Civil anti-disaster organizations' information was derived from detailed scholarly monographs, specialty publications, and previous studies of master doctorate dissertation. Results: Volunteer Fire Department and voluntary crime prevention groups show problems related to budgetary deficits and volunteer deficiency. In order to resolve these issues, laws must be enacted to guarantee interest and support. In addition, the Citizen Corps Active in Disaster (CAIND) organization requires a dedicated salary system to address the investment of its workforce and the cost of heavy equipment. Moreover, deficiencies were revealed regarding the lack of systems in support of occupational education and training. In conclusion, several weak points require close attention. Conclusion: The results of this comparative analysis study about the domestic and foreign civil anti-disaster organizations provide insight into identity materialization and concept establishment.