• Title/Summary/Keyword: Active antenna

Search Result 288, Processing Time 0.028 seconds

Improvement of lower hybrid current drive systems for high-power and long-pulse operation on EAST

  • M. Wang;L. Liu;L.M. Zhao;M.H. Li ;W.D. Ma;H.C. Hu ;Z.G. Wu;J.Q. Feng ;Y. Yang ;L. Zhu ;M. Chen ;T.A. Zhou;H. Jia;J. Zhang ;L. Cao ;L. Zhang ;R.R. Liang;B.J. Ding ;X.J. Zhang ;J.F. Shan;F.K. Liu ;A. Ekedahl ;M. Goniche ;J. Hillairet;L. Delpech
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4102-4110
    • /
    • 2022
  • Aiming at high-power and long-pulse operation up to 1000 s, some improvements have been made for both 2.45 GHz and 4.6 GHz lower hybrid (LH) systems during the recent 5 years. At first, the guard limiters of the LH antennas with graphite tiles were upgraded to tungsten, the most promising material for plasma facing components in nuclear fusion devices. These new guard limiters can operate at a peak power density of 12.9 MW/m2. Strong hot spots were usually observed on the old graphite limiters when 4.6 GHz system operated with power >2.0 MW [B. N. Wan et al., Nucl. Fusion 57 (2017) 102019], leading to a reduction of the maximum power capability. With the new limiters, 4.6 GHz LH system, the main current drive (CD) and electron heating tool for EAST, can be operated with power >2.5 MW routinely. Long-pulse operation up to 100 s with 4.6 GHz LH power of 2.4 MW was achieved in 2021 and the maximal temperature on the guard limiters measured by an infrared (IR) camera was about 540 ℃, much below the permissible value of tungsten material (~1200 ℃). A discharge with a duration of 1056 s was achieved and the 4.6 GHz LH energy injected into the plasma was up to 1.05 GJ. Secondly, the fully-active-multijunction (FAM) launcher of 2.45 GHz system was upgraded to a passive-active-multijunction (PAM), for which the density of optimum coupling was relatively low (below the cut-off value). Good coupling with reflection coefficient ~3% has been achieved with plasma-antenna distance up to 11 cm for the new PAM. Finally, in order to eliminate the effect of ion cyclotron range of frequencies (ICRF) wave on 4.6 GHz LH wave coupling, the location of the ICRF launcher was changed to a port that is located 157.5° toroidally from the 4.6 GHz LH system and is not magnetically connected.

Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.

Studies on the External Structure of the Cuticle of Silkworm pupa (Bombyx mori L.) (가잠용외피의 외부구조에 관한 조사연구)

  • 윤종관
    • Journal of Sericultural and Entomological Science
    • /
    • v.20 no.2
    • /
    • pp.10-14
    • /
    • 1978
  • There are relatively many reports have been issued on he active movement of cuticle of larva. which tend to protect their body, however, only a few reports have been disclosed on the cuticle of pupal body except the small portion of rectangle which shown tortoise-shell shape. In this connection, many portion of the external structure of pupal cuticle has been studied and the following. results were found: 1) No. spot of rectangle which is sculptured in the surface of cuticle that born by branching. out of the development of cell in imaginal bud of antenna and head were found. However, in the compound eye of net shaped sculpture was found in the (equation omitted) shaped parts which holding. the diameter of about 8u and the surrounding area has the small bump and the one is dark brown coloured comparing with shape. 2) The sculpture shape of thorax is a little different than in the head. However, (equation omitted) portion is varies from the segment to segment. In general, it is not very clear than the compound eye in the head, the dark brown bump shape is slowly fade a from the prothorax, mesothorax to metathorax. 3) The surface of intersegment membrane is colourless or slightly yellow, and the entire surface has stripped marking with thine lines. 4) In the abdominal segment, there are many and small sculptures in net shape around the (equation omitted) shape portions. 5) The size of sculpture in (equation omitted) portion of abdomen is smaller than one in thorax, and in the same segment, the dorsal is smaller than abdomen and the rear portion of the segment is larger than the front of segment. 6) After the 7th abdominal segment, no intersegmental membrane is found and the cuticle of the external structure is the same as external structure of the segment. 7) The seta is not found in head, compound eye, antenna and wing which portions were subdivided by development of imagined bud of the cell, no seta is found in cuticle of the segment in the general cell of the larva stage and also in the dorsal and intersegmental membrane.

  • PDF

Evaluating of the Effectiveness of RTK Surveying Performance Based on Low-cost Multi-Channel GNSS Positioning Modules (다채널 저가 GNSS 측위 모듈기반 RTK 측량의 효용성 평가)

  • Kim, Chi-Hun;Oh, Seong-Jong;Lee, Yong-Chang
    • Journal of Cadastre & Land InformatiX
    • /
    • v.52 no.2
    • /
    • pp.53-65
    • /
    • 2022
  • According to the advancement of the GNSS satellite positioning system, the module of hardware and operation software reflecting accuracy and economical efficiency is implemented in the user sector including the multi-channel GNSS receiver, the multi-frequency external antenna and the mobile app (App) base public positioning analysis software etc., and the multichannel GNSS RTK positioning of the active configuration method (DIY, Do it yourself) is possible according to the purpose of user. Especially, as the infrastructure of multi-GNSS satellite is expanded and the potential of expansion of utilization according to various modules is highlighted, interest in the utilization of multi-channel low-cost GNSS receiver module is gradually increasing. The purpose of this study is to review the multi-channel low-cost GNSS receivers that are appearing in the mass market in various forms and to analyze the utilization plan of the "address information facility investigation project" of the Ministry of Public Administration and Security by constructing the multi-channel low-cost GNSS positioning module based RTK survey system (hereinafter referred to as "multi-channel GNSS RTK module positioning system"). For this purpose, we constructed a low-cost "multi-channel GNSS RTK module positioning system" by combining related modules such as U-blox's F9P chipset, antenna, Ntrip transmission of GNSS observation data and RTK positioning analysis app through smartphone. Kinematic positioning was performed for circular trajectories, and static positioning was performed for address information facilities. The results of comparative analysis with the Static positioning performance of the geodetic receivers were obtained with 5 fixed points in the experimental site, and the good static surveying performance was obtained with the standard deviation of average ±1.2cm. In addition, the results of the test point for the outline of the circular structure in the orthogonal image composed of the drone image analysis and the Kinematic positioning trajectory of the low cost RTK GNSS receiver showed that the trajectory was very close to the standard deviation of average ±2.5cm. Especially, as a result of applying it to address information facilities, it was possible to verify the utility of spatial information construction at low cost compared to expensive commercial geodetic receivers, so it is expected that various utilization of "multi-channel GNSS RTK module positioning system"

A Time Comparison Measurement Technique for eLoran Receivers (시각비교를 위한 eLoran 수신기 지연측정 기술)

  • Lee, Chang-Bok;Lee, Jong-Koo;Lee, Young-Kyu;Hwang, Sang-wook;Yang, Sung-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.40 no.6
    • /
    • pp.385-390
    • /
    • 2016
  • ELoran Systems can provide Position, Navigation, and Time services with comparable performance to Global Positioning Systems (GPS) as a back up or alternative system. High timing and navigation performance can be achieved by eLoran signals because eLoran receivers use "all-in-view" reception. This incorporates Time of Arrival (TOA) signals from all stations in the service range because each eLoran station is synchronized to Coordinated Universal Time (UTC). Transmission station information and the differential Loran correction data are transmitted via an additional Loran Data Channel (LDC) on the transmitted eLoran signal such that eLoran provides improved Position Navigation and Timing (PNT) over legacy Loran. In this paper, we propose a technique for adapting the delay time compensation values in eLoran timing receivers to provide precise time comparison. For this purpose, we have designed a system that measures time delay from the crossing point of the third cycle extracted from the current transformer at the end point of the transmitter. The receiver delay was measured by connecting an active H-field, an E-field and a passive loop antenna to a commercial eLoran timing receiver. The common-view time transfer technique using the calibrated eLoran timing receiver improved the eLoran transfer time. A eLoran timing receiver calibrated by this method can be utilized in the field for precise time comparison as a GNSS backup.

A Design and Fabrication of a Compact Ka Band Transmit/Receive Module Using a Quad-Pack (쿼드팩을 이용한 소형 Ka 대역 송수신(T/R) 모듈의 설계 및 제작)

  • Oh, Hyun-Seok;Yeom, Kyung-Whan;Chong, Min-Kil;Na, Hyung-Gi;Lee, Sang-Joo;Lee, Ki-Won;Nam, Byung-Chang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.389-398
    • /
    • 2011
  • In this paper, the design and fabrication of a transmit/receive(T/R) module for Ka-band phased array radar is presented. A 5bit digital phase shifter and digital attenuator were used in common for both transmitter and receiver considering unique Ka-band characteristic. The circulator was excluded in the T/R module and was placed outside T/R module. The transmitting power per element antenna is designed to be about 1 W and the noise figure is designed to be below 8 dB. The designed T/R module RF part has a compact size of $5\;mm{\times}4\;mm{\times}57\;mm$. In order to implement the T/R module, MMICs used in T/R module was separately assessed before assembly of the designed T/R module. The transmitter of the fabricated T/R module shows about 1 W at 5 dBm unit module input power and the receiver shows a gain of about 20 dB and a noise figure of below 8 dB as expected in the design stage.

Mapping Precise Two-dimensional Surface Deformation on Kilauea Volcano, Hawaii using ALOS2 PALSAR2 Spotlight SAR Interferometry (ALOS-2 PALSAR-2 Spotlight 영상의 위성레이더 간섭기법을 활용한 킬라우에아 화산의 정밀 2차원 지표변위 매핑)

  • Hong, Seong-Jae;Baek, Won-Kyung;Jung, Hyung-Sup
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_3
    • /
    • pp.1235-1249
    • /
    • 2019
  • Kilauea Volcano is one of the most active volcano in the world. In this study, we used the ALOS-2 PALSAR-2 satellite imagery to measure the surface deformation occurring near the summit of the Kilauea volcano from 2015 to 2017. In order to measure two-dimensional surface deformation, interferometric synthetic aperture radar (InSAR) and multiple aperture SAR interferometry (MAI) methods were performed using two interferometric pairs. To improve the precision of 2D measurement, we compared root-mean-squared deviation (RMSD) of the difference of measurement value as we change the effective antenna length and normalized squint value, which are factors that can affect the measurement performance of the MAI method. Through the compare, the values of the factors, which can measure deformation most precisely, were selected. After select optimal values of the factors, the RMSD values of the difference of the MAI measurement were decreased from 4.07 cm to 2.05 cm. In each interferograms, the maximum deformation in line-of-sight direction is -28.6 cm and -27.3 cm, respectively, and the maximum deformation in the along-track direction is 20.2 cm and 20.8 cm, in the opposite direction is -24.9 cm and -24.3 cm, respectively. After stacking the two interferograms, two-dimensional surface deformation mapping was performed, and a maximum surface deformation of approximately 30.4 cm was measured in the northwest direction. In addition, large deformation of more than 20 cm were measured in all directions. The measurement results show that the risk of eruption activity is increasing in Kilauea Volcano. The measurements of the surface deformation of Kilauea volcano from 2015 to 2017 are expected to be helpful for the study of the eruption activity of Kilauea volcano in the future.

Studies on Biology and Control of the Mulberry Small Weevil, Baris deplanata ROELOFS (Coleoptera: Curculionidae) (뽕나무애바구미의 생태 및 방제에 관한 연구)

  • 백현준;백운하
    • Journal of Sericultural and Entomological Science
    • /
    • v.18 no.2
    • /
    • pp.65-78
    • /
    • 1976
  • The mulberry small weevil, Baris deplanata ROELOFS, has highly infested mulberry trees in Korea. As the damage caused by the mulberry small weevil in mulberry fields has been increased over the country since 1969, the authors has carried out a series of biological and controlling studies on the pest from 1971 to 1972. The results obtained are summarized as follows. 1. The adult weevil is elongate oval in shape with black in color and the probocis is long as usual in curculionidae. The size of adult female is 3.30${\pm}$0.04mm in length, 1.47${\pm}$0.04mm in width, and the length of proboscis is 1.25${\pm}$0.014mm, while adult male is 3.28${\pm}$0.06mm in length, 1.40${\pm}$0.04mm in width, and the length of proboscis is 1.30${\pm}$0.02mm. The antenna is geniculate consisting of 12 segments. The terminal sternite of the abdomen has a pointed tip in male but not in female. 2. The egg is long oval in shape, milky white in color, 0.51${\pm}$0.05mm in length and 0.32${\pm}$0.02mm in width. 3. The mature larva is cylindrical and light yellowow in color except the head of dark brown, and legless, 3.88${\pm}$0.06mm in length, 1.40${\pm}$0.02mm width, each segment bearing many wrinkless and short setae. 4. The pupa is long oval, milky white and exarate, 3.53${\pm}$0.09 in length, 1.40${\pm}$0.03mm in width. 5. Majority of the species has one generation through a year and overwinters as adult in xylem of withered branch and come out again from late April to early May in next year. But some of the female oviposit in the same year and the offsprings overwinter as larva (0.4%) or pupa (0.1%) 6. The eggs are mostly laid under the cork layer of withered branch and the number of eggs deposited by an adult female is 73.44${\pm}$8.74, the average egg-laying period is 33.88${\pm}$6.04 days. The incubation period is 11.69${\pm}$0.39 days, the larval period 45.04${\pm}$1.63 and the pupal period 11.05${\pm}$0.49 days. The period of adult's activity is 46.7${\pm}$5.90 days. 7. The larvae feed on the cambium under the bark and adults feed on the winter bud, the latent bud, the leaf stalk and the base of newly shoot. 8. An active period of adults was observed during the period of 4 months from April to July. However, the peak of adult-density occurred in the early May (in the fields of spring-prunning) and early to middle June(in the fields of summer-prunning). 9. There is a positive correlation between the density of larvae and diameter and length of the branches. 10. The pattern of distributions of the adult of mulberry small weevil is negative binomial distribution. 11. The chalcid fly was disclosed to be a natural enemy which was parasite on the larvae of mulberry small weevil and its parasitic ratio was 11.9%. 12. Phosvel D, Malix D, Salithion EC, DDVP EC, and Phosvel EC were effective for the control of adults and Satchukoto-S EC, and Salithio EC were effective for the control of larvae.

  • PDF