• Title/Summary/Keyword: Active Thermal Control

Search Result 127, Processing Time 0.026 seconds

Convenient Thermal Modeling for Loss Distribution method of 3-Level Active NPC Inverter using Newton's Law of cooling (Active NPC 인버터의 손실 분배 제어를 위한 뉴턴의 냉각법칙 기반의 간단한 열 모델링 기법)

  • Hyun, Seung-Wook;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.71-80
    • /
    • 2015
  • This paper proposes a convenient thermal modeling method for loss distribution control method of 3-level Active NPC(Neutral Point Clamped) inverter. In the drawback of conventional 3-level NPC, the generated losses can occur unbalance in each switching device, as a result, thermal utilization of designed system has been decreased. In order to compensate unbalanced losses, Active NPC inverter performed loss balancing control with thermal modeling during operation of each switching device. Therefore, this paper deals with a convenient thermal modeling method based on newton's law of cooling rather than conventional thermal modeling method. Both simulation and experimental results based on 10kW 3-level Active NPC inverter confirm the validity of the analysis performed in the study.

Narrowband Active Control of Noise in Thermal Power Plants (협대역 능동소음 제어기법을 이용한 화력발전소 소음제어)

  • 남현도;서성대;황정현
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.34-40
    • /
    • 2001
  • In this paper, a narrowband active noise control system to reduce the noise in thermal power plants is proposed. The narrowband active noise control system contains rectangular wave generator and has a multi channel feed forward adaptive algorithms which uses the adjoint LMS algorithm. Although the effectiveness have been proven in the filtered-X LMS broadband active noise control system, this algorithm has much more computational complexity than that of narrowband active noise control system. The proposed active control system that uses the adjoint LMS algorithm, compared to the previous broadband active noise control system, not only is more effective in controlling narrowband noise but also has a more stable structure. Adaptive filter contains the FIR structure and IIR structure for primary and secondary path models. The simulation proves the effectiveness of the proposed algorithm.

  • PDF

TEC를 이용한 인공위성 열제어 시스템의 특성 고찰

  • 김귀순;이수상;장영근;최해진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.04a
    • /
    • pp.24-24
    • /
    • 1999
  • This study addresses the effectiveness of TEC(Thermoelectric cooler) application for spacecraft thermal control. The required radiator area and power consumption characteristics of active thermal control using TEC are compared with the passive control at BOL and EOL through unsteady thermal analyses by calculating external heat fluxes. When the component operating temperature is low enough in TEC active control, the required radiator area can be smaller than the passive thermal control. TEC also needs less power consumption than the passive control under the condition that the temperature of cooling pars is low enough and/or the design temperature margin of the components is narrow enough.

  • PDF

Analysis of Visible Light Communication Module Degraded by High Dose-Rate Gamma Irradiation using Thermal Infrared Image (적외선 열영상을 이용한 가시광 통신모듈의 고선량 감마선조사에 따른 열화 분석)

  • Cho, Jai-Wan;Hong, Seok-Boong;Koo, In-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.12
    • /
    • pp.1203-1209
    • /
    • 2011
  • In this paper, the degradation evaluation method of VLC (Visible Light Communication) wireless module after high dose rate gamma-ray irradiation using the thermal infrared camera is proposed. First, the heating characteristics of the active devices embedded in the VLC wireless module during the condition of normal operation is monitored by thermal infrared camera. By the image processing technique, the trends of the intensity of the heat emitted by the active devices are calculated and stored. The feature of the blob area including the area of the active devices in the thermal infrared image is extracted and stored. The feature used in this paper is the mean value of the gray levels in the blob area. The same VLC module has been gamma irradiated at the dose rate of about 4.0 kGy/h during 72 hours up to a total dose of 288 kGy. And then, the heating characteristics of the active devices embedded in the VLC wireless module after high dose gamma ray irradiation is observed by thermal infrared camera. The high dose gamma-ray induced degradation of the active devices embedded in the VLC module was evaluated by comparing the mean value of the blob area to the one of the same blob area of the VLC module before the gamma ray irradiation.

Thermal Response and Sensitivity Analysis of Satellite Propulsion Tank (인공위성 추진제 탱크의 열적 반응 및 민감도 해석)

  • Han Cho Young;Lee Kyun Ho;Yu Myoung Jong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.131-136
    • /
    • 2004
  • Thermal control of satellite propellant tank is achieved by patch heaters enabled by thermostat's behavior. It is important to attach the thermostat on the appropriate position of the propellant tank. However its position cannot be given with exact numerics because tank is spherical. Actually the position for thermostat is designated in relevant drawing approximately, therby, the engineer practices depending on his own experience and intuition. The sensitivity analysis for the position of thermostat is performed such that the influence on the thermal behavior and control of tank is examined quantatively. When assembling tank module, the reasonable performance on the thermal control is believed with possible human errors if the uncertainty in the position of thermostat is not quite large.

  • PDF

Thermal sensation based humidity controls for improving indoor thermal comfort and energy efficiency in summer (온열감각 기반 습도제어를 통한 여름철 건물의 열쾌적 및 에너지성능 향상)

  • Moon, Jin Woo;Chin, Kyung-Il;Kim, Sang-Chul;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.75-81
    • /
    • 2014
  • This study aims at investigating the benefit of actively controlling humidity to improve thermal comfort and energy efficiency in climate zones other than hot-dry. For this research purpose, three thermal control strategies, which adopted different initiative degrees in humidity control, were developed - i) temperature controls, ii) temperature and humidity controls, and iii) thermal sensation controls. Performance of the developed strategies were experimentally tested in a full scale mock up of an office environment. The study revealed that air temperature was better controlled in the occupied zone under the first two strategies than the thermal sensation based strategy. On the other hand, the thermal sensation-based strategy maintained thermal sensation levels more comfortably. In addition, energy consumption was significantly reduced when humidity was actively controlled for thermal comfort. The thermal sensation-based control strategy consumed significantly less electricity than the first two strategies. From these findings, this study indicated that adoption of an active humidity control system based on thermal sensation can provide increased thermal comfort as well as energy savings for summer seasons in climatic zones other than hot-dry.

The Effects of Active Warming on Pain, Temperature, and Thermal Discomfort in Postoperative Patients after General Anesthesia for Abdominal Surgery (전신마취 복부 수술 후 적극적인 가온요법이 통증, 체온 및 체온불편감에 미치는 효과)

  • Kim, Unjin;Lee, Yun Mi
    • Journal of Korean Critical Care Nursing
    • /
    • v.10 no.3
    • /
    • pp.53-64
    • /
    • 2017
  • Purpose : This study investigated the effects of active warming using a Warm Touch warming system or a cotton blanket in postoperative patients after general anesthesia for abdominal surgery. Methods : This quasi-experimental study utilized two experimental groups and one control group: a cotton-blanket group (n = 25) were warmed with a cotton blanket and a sheet; a forced-air warming group (n = 24) were warmed with a Warm Touch warming system, a cotton blanket, and a sheet; and a control group (n = 25) were warmed with a sheet. Measurement variables were postoperative pain, body temperature, and thermal discomfort. Data were analyzed using a one-way ANOVA, ${\chi}^2-tests$, Fisher's exact test, and a repeated measures ANOVA. Results : The effects of active warming using a Warm Touch warming system and a cotton blanket on postoperative patients was significant in reducing pain (F = 13.91, p < .001) and increasing body temperature (F = 12.49, p < .001). Conclusion : Active warming made a significant difference in pain and body temperature changes. Active warming methods may help patients' postoperative recovery and prevent complications. Further research is needed to explore the effects and side effects of active warming on recovering normothermia.

  • PDF

THE ORBITAL THERMAL ANALYSIS OF HAUSAT-2 AND ITS THERMAL CONTROL SUBSYSTEM PRELIMINARY DESIGN (HAUSAT-2의 궤도 열해석과 열제어계의 예비설계)

  • Lee Mi-Hyeon;Kim Dong-Woon;Chang Young-Keun
    • Bulletin of the Korean Space Science Society
    • /
    • 2005.04a
    • /
    • pp.129-132
    • /
    • 2005
  • This paper describes BAUSAT-2 orbital thermal analysis and preliminary design of thermal control subsystem. To design thermal control subsystem of HAUSAT-2, we have considered active & passive thermal control method based on basic theory and themal equilibrium equation. Using this result, suitable thermal control method and material have been selected. We have designed thermal control subsystem based on analysis of HAUSAT-2's thermal environments on sun synchronous orbit with altitude 650km, inclination $98^{\circ}$ and thermal distribution and range expectation of each HAUSAT-2's surface. Thermal analysis consists of system level, box level and board level analysis. We have completed system level and box level analysis. Till now, board level analysis of main heat dissipation board in progress. Thermal control subsystem has designed according to thermal analysis result. This design is to maintain all of the HAUSAT-2 components within the allowable temperature limits. In future, STM

  • PDF

The Experimental Research for the Use Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 이용특성에 대한 실험적 연구)

  • Lee, Dong-Won;Kwak, Hee-You
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.82-88
    • /
    • 2013
  • There are the stirring test and drain test in the daily performance test to determine the thermal performance of a domestic solar hot water system. The drain test is a test that measures the discharge heating rate while drain the hot water from the top of the storage tank and supply the city water to the bottom of the tank. From the perspective of the user, this drain test is more effective than the stirring test. In this study, the thermal performance were compared through the drain test for a passive type and an active type domestic solar hot water systems consisting of the same storage tank and collectors. At this point, a passive type was used the horizontal storage tanks, and an active type was used vertical storage tank. In the drain test, when the hot water drained up to the reference hot water temperature, an active type which have vertical storage tank represents excellent daily performance than a passive type which have horizontal storage tank regardless of weather conditions. The reason for this is because the vertical storage tank is advantageous to thermal stratification in the tank. After the drain test, the residual heat for the horizontal storage tank was much more than the vertical storage tank, but in the next day the amount of discharged heat were less than the those of vertical storage tank neither. Thus, the solar water heating system which have horizontal storage tank should be adopted preheating control method rather than separate using control method when connected with auxiliary heat source device.