• 제목/요약/키워드: Active Sound Control

검색결과 146건 처리시간 0.02초

전통주택의 차음성능 평가에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Performance of Korean Traditional Houses)

  • 김선우;이태강;김형렬;김항;최은석
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.141-148
    • /
    • 2006
  • Korean traditional houses have been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various Passive system of using natural materials, considering micro climate, building lay out, and these system are much natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed the acoustical characteristics of Korean traditional houses varied with lay out and floor plan to reflect the way of control for environmental condition. The reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen are measured in each houses. As a result, the reverberation time of Korean traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building. These above results show that our traditional house are much more emphasized seeking visual privacy of rooms than aural privacy.

항공기용 하니콤 트림판넬의 다채널 능동제어 (Multichannel Active Control of Honeycomb Trim Panels for Aircrafts)

  • 홍진숙
    • 한국소음진동공학회논문집
    • /
    • 제16권12호
    • /
    • pp.1252-1261
    • /
    • 2006
  • This paper summarizes theoretical work on the multichannel decentralized feedback control of sound radiation from aircraft trim panels using piezoceramic actuators. The aircraft trim panels are generally honeycomb structures designed to meet the design requirement of low weight and high stiffness. They are resiliently-mounted to the fuselage for the passive reduction of noise transmission. It is motivated by the localization of reduction in vibration of single channel active trim panels. 12-channel decentralized feedback control systems are investigated in terms of the reduction of noise and vibration for three configurations of sensor actuator pairs. Local coupling of the closely-spaced sensor and actuator pairs was modeled using single degree of freedom systems. The multichannel control system is characterized using the state-space model. For the stability point of view, the relative stability or robustness is evaluated by comparing the real part of eigenvalues of the system matrix for the three configurations. The control performance is also evaluated and compared for the three configurations. It is found that the multichannel system can lead to the globalization of the reduction in vibration and radiated noise. It does not appear to yield a significant improvement in the vibration because of decreased gain margin. However, the reduction in the radiated noise is remarkably improved due to the variation of the vibration pattern with the actuation configurations.

부산 도시철도 3호선 차량 곡선부 스퀼소음 특성 (Analysis of Curve Squeal Noise for Busan Metro Line 3)

  • 홍도관;안찬우;한근조;강현욱
    • 한국정밀공학회지
    • /
    • 제28권4호
    • /
    • pp.427-435
    • /
    • 2011
  • This paper deals with the measurement and analysis of the squeal noise according to the curvature of rail. The squeal noise is generated by the friction between the railway with curve and the wheel. The squeal noise is a big problem in Busan Metro Line 3. If the developing panel type ANC(Active Noise Control) system which is attached to the floor can reduce 5 dB in below 500 Hz, the sound pressure level of the whole band pass can be reduced about 4-4.8 dB in squeal noise above the curvature of R400. Curve squeal noise is the intense high frequency tonal that can occur when a railway vehicle transverses a curve. The frequency range is from around 500 to almost 20,000 Hz, with noise levels up to about 15 dB in curve.

Experimental Investigation of Supersonic Jet Noise Reduction Using Microjet Injection

  • Mamada, Ayumi;Watanabe, Toshinori;Uzawa, Seiji;Himeno, Takehiro;Oishi, Tsutomu
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.622-627
    • /
    • 2008
  • Experiment of active noise control on supersonic jet noise was conducted by use of microjet injection. The microjets were injected to the shear layer of the main jet through 22 small holes at the lip of a rectangular nozzle. Based on the measurement of farfield sound pressure, it was found that the jet noise was effectively reduced by several dB(in some cases up to 10 dB). The power levels of all measurement points were also reduced by use of microjet injection. The microjet affected not only the broadband noise but also the screech tone noise. The sound pressure level, the frequency of the screech tone, and the structure of the jet could be changed by the microjet. Flow visualization with schlieren technique was also made to observe the effect of microjet on the flow field.

  • PDF

IEC60268-21 기반 최신 액티브 스피커 측정 및 분석 기법 소개 (Introduction of a recent active loudspeaker measurement and assessment method based on IEC60268-21)

  • 이신렬
    • 한국음향학회지
    • /
    • 제40권3호
    • /
    • pp.241-246
    • /
    • 2021
  • 현재 라우드스피커 시스템은 다양한 입력 채널 및 앰프를 포함하는 액티브 스피커로 변화하고 있다. 이러한 액티브 스피커의 경우 기존 패시브 스피커 혹은 유닛 단품 측정 표준인 IEC 60268-5 만으로 측정이 불가능한 경우가 많다. 본 논문은 IEC한국 대표로 IEC60268-21 표준을 제정하면서 새롭게 정의한 아날로그, 디지털 입력 및 유선, 무선 입력 채널을 가지고 다양한 제어 기능을 가진 파워 앰프를 내장한 액티브 스피커 측정 표준에 대해 상세하게 알아보고자 한다.

MRI 소음의 특성을 이용한 공동 내부 목표점의 능동소음 제어 (Active Noise Control for Target Point Inside Bore Using Property of MRI Noise)

  • 이록행;박영진;박윤식
    • 한국소음진동공학회논문집
    • /
    • 제24권1호
    • /
    • pp.62-68
    • /
    • 2014
  • Recently, MRI(magnetic resonance imager) scanner is continually used for medical diagnosis and many biomedical researches. When it operates, however, intense noise is generated. The SPL(sound pressure level) of the noise approaches 130 dB especially in 3 T(Tesla) MRI. Meanwhile, more than 3 T MRI scanners have been developed to get higher-resolution images, so louder noise is expected in the future. The intense noise makes patients feel nervous and uncomfortable. Moreover, it could possibly cause hearing loss to patient in extreme cases. For this reason, some active noise control systems have been researched. One of them used feedback Filtered-X LMS(FXLMS) algorithm which is able to control only narrowband noises and possible to diverge in severe case. In this paper, we determine the property of MRI noise. Using the property, we applied a method of open-loop and adaptive control for reducing MRI noise at target point inside bore. We verified performance of the method with computer simulation and preliminary experiment. The results demonstrate that the method can effectively reduce MRI noise at target point.

전력용변압기의 구조진동해석 및 능동소음제어 (Structure Vibration Analysis and Active Noise Control of Power Transformer)

  • 정윤미;최은지;김영달
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1771-1776
    • /
    • 2013
  • Most cases of power transformer failure are caused by physical factors linked to the transient vibrations of multiple 120Hz combinations. In addition, the noise generated in the transformer from this vibration not only directly contributes to the worsening of the work environment but also causes psychological stress, resulting in the worsening of the workers efficiency and of the living environment of the inhabitants around the power plant. Thus, to remedy these problems, the mechanical-excitation forces working on a power transformer were categorized in this study, and the mechanical-damage mechanism was identified through the vibration transfer paths acting on machines or structures. In addition, a study on active noise cancellation in a transformer using the FXLMS algorithm was conducted to develop a system that is capable of multiple-sound/channel control, which resulted in the active noise reduction effect when applied on the field.

저주파 순음소음저감을 위한 능동 순음 소음제어 (Active Tonal Noise Control to Reduce the Low Frequency Tonal Sound)

  • 나희승;박영진
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1037-1042
    • /
    • 1998
  • This paper discusses the dependence of the convergence rate on the acoustic error path in these popular algorithms and introduces new algorithms which increase the convergence region regardless of the time-delay in the acoustic error path. We also Propose a novel control algorithm (AFC/CAFC) for tonal noise cancellation. The proposed algorithm estimates the magnitude and phase of the tonal noise. The algorithm uses the steepest descent method for the phase/magnitude estimation. Performances of tile CAFC algorithm are presented in comparison with those by the AFC algorithm based on computer simulations and experiments.

  • PDF

전달경로의 차이를 이용한 차량용반능동형 머플러의 특성에 관한 연구 (A Research on Characteristics of Semi-active Muffler Using Difference of Transmission Paths)

  • 이종민;김경목;손동구;이장현;황요하
    • 소음진동
    • /
    • 제11권3호
    • /
    • pp.401-409
    • /
    • 2001
  • Passive type mufflers installed on every car haute inherent problem of lowering engine power and fuel efficiency caused by backpressure which is byproduct of complex internal structure. Recent improvements like installing a calve to change exhaust gas path depending on power requirement and rpm have only marginally improved performance. Tremendous amount of recent research works on active exhaust noise control have failed to commercialize because of numerous physical and economical reasons. In this paper, a unique seal-active muffler using difference of transmission paths is presented. In this system exhaust pipe is divided into two and joined again downstream. Exhaust noise is reduced by destructive interference when two-divided noise join again with transmission paths'difference which is half of the wavelength of a main noise frequency. One divided path has a sliding mechanism to change length thereby transmission path length difference is adjusted to entwine rpm change. The proposed system has minimal backpressure and does not need a secondary sound source like a speaker so it can overcome many problems of failed active noise control methods. We have verified proposed system's superior performance by simulation and comparison experiment with passive mufflers.

  • PDF

Human-Robot Interaction in Real Environments by Audio-Visual Integration

  • Kim, Hyun-Don;Choi, Jong-Suk;Kim, Mun-Sang
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권1호
    • /
    • pp.61-69
    • /
    • 2007
  • In this paper, we developed not only a reliable sound localization system including a VAD(Voice Activity Detection) component using three microphones but also a face tracking system using a vision camera. Moreover, we proposed a way to integrate three systems in the human-robot interaction to compensate errors in the localization of a speaker and to reject unnecessary speech or noise signals entering from undesired directions effectively. For the purpose of verifying our system's performances, we installed the proposed audio-visual system in a prototype robot, called IROBAA(Intelligent ROBot for Active Audition), and demonstrated how to integrate the audio-visual system.