• 제목/요약/키워드: Active Noise Barrier

검색결과 24건 처리시간 0.022초

Visualization and classification of hidden defects in triplex composites used in LNG carriers by active thermography

  • Hwang, Soonkyu;Jeon, Ikgeun;Han, Gayoung;Sohn, Hoon;Yun, Wonjun
    • Smart Structures and Systems
    • /
    • 제24권6호
    • /
    • pp.803-812
    • /
    • 2019
  • Triplex composite is an epoxy-bonded joint structure, which constitutes the secondary barrier in a liquefied natural gas (LNG) carrier. Defects in the triplex composite weaken its shear strength and may cause leakage of the LNG, thus compromising the structural integrity of the LNG carrier. This paper proposes an autonomous triplex composite inspection (ATCI) system for visualizing and classifying hidden defects in the triplex composite installed inside an LNG carrier. First, heat energy is generated on the surface of the triplex composite using halogen lamps, and the corresponding heat response is measured by an infrared (IR) camera. Next, the region of interest (ROI) is traced and noise components are removed to minimize false indications of defects. After a defect is identified, it is classified as internal void or uncured adhesive and its size and shape are quantified and visualized, respectively. The proposed ATCI system allows the fully automated and contactless detection, classification, and quantification of hidden defects inside the triplex composite. The effectiveness of the proposed ATCI system is validated using the data obtained from actual triplex composite installed in an LNG carrier membrane system.

셀룰로우스 기반의 EAPap 작동기의 PEDOT_PSS/Pentacene를 이용한 Schottky diode 성능 개선 (Improved performance of PEDOT:PSS/pentacene Schottky diode on EAPap)

  • 임현규;조기연;강광선;김재환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.77-81
    • /
    • 2007
  • Pentacene was dissolved in N-methyspyrrolidone (NMP) and mixed with poly(3,4-ethylenedioxythiophene), poly(styrenesulfonate) (PEDOT:PSS). The solution color changed from deep purple to intense yellow. As the dissolution time increased, visible absorption decreased and ultraviolet (UV) absorption increased. PEDOT:PSS or Pentacene-PEDOT:PSS was spin-coated to control the layer thickness. Three-layered Schottky diodes consisting of Al, PEDOT:PSS or PEDOT:PSS-pentacene, and Au with thickness of 300nm, respectively, were fabricated. The current densities of $4.8{\mu}A/cm^2$ at 2.5MV/m and $660{\mu}A/cm^2$ at 1.9MV/m were obtained for the Au/PEDOT:PSS/Al and Au/Pentacene-PEDOT:PSS/Al Schottky diodes, respectively. The current density of the Schottky diode was enhanced by about two orders of magnitude by doping pentacene to PEDOT:PSS.

  • PDF

능동형 방음벽 개발을 위한 에러센서 위치 연구 (A Study of Sound Pressure Characteristics of Error Sensors by Position in Active Noise Barrier Development)

  • 차상곤;김동환;안드레이 트로신;최장철;신은우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1756-1757
    • /
    • 2011
  • 본 논문에서는 FXLMS 알고리즘을 이용하여 3차원 폐공간(반무향실)에서의 순음(125Hz)을 이용하여 부 음원과 에러센서의 위치 변화에 따른 소음저감 정도를 분석하였으며, 이 결과를 바탕으로 능동형 방음벽의 구현의 기초자료로 활용하고자 하였다. 부음원(제어스피커, 이하 부음원)과 에러센서간 거리차는 0.5m, 1.5m, 2.5m를 대상으로 실험을 실시하였으며 그 중 거리차가 1.5m 지점의 경우, 125Hz부근에서는 최대 18.3dB, Overall(80Hz~200Hz)값은 18.2dB(A)의 소음저감 효과가 있는 것으로 나타나, 가장 효과적인 부음원과 에러센서간의 거리차인 것으로 평가되었다.

  • PDF

감조하천에 연결된 하수처리장 방류구의 거품 형성기작 해석 및 거품발생 저감기술의 실험적 현장적용 (Explanation of Foaming Mechanism and Experimental Application of Foam Reduction Techniques in the Treated Wastewater Outlet of Wastewater Treatment Plant Connected to a Tidal River, Korea)

  • 신재기;조영수;김영성;강복규;황순진
    • 생태와환경
    • /
    • 제49권3호
    • /
    • pp.187-196
    • /
    • 2016
  • 본 연구는 감조하천과 연결된 하수처리장 방류구에서 발생하는 거품의 형성기작 해석과 저감기술의 실험적용을 위하여 2015년 3월부터 2016년 7월까지 수행하였다. 거품은 방류구와 하천 수면 사이의 낙차에 의한 공기연행과 거품확산방지막에 의한 내부축적이 원인이었다. 특히 썰물 때와 방류량이 많을 때에 거품성장이 가장 활발하였다. 이를 해결하기 위하여 방류수로와 방류구에 각각 미세스크린 망과 수중방류 인공수로장치를 각각 설치한 후 실험하였다. 거품 저감효과는 각각 약 85.0~92.0%, 70.7~85.6% 범위였다. 또한, 거품뿐만 아니라 소음 등 부가적인 문제점도 해결할 수 있었고, 무엇보다도 민원예방에 기여할 것으로 본다. 본 연구는 단일 하수처리장을 대상으로 하였으나, 국내 다른 하수처리장의 유사한 사례에도 응용될 수 있을 것으로 사료된다.