• Title/Summary/Keyword: Active Mechanical Equipment

Search Result 37, Processing Time 0.029 seconds

Development and Evaluation of a Hybrid Damper for Semi-active Suspension (반능동 현가장치의 하이브리드형 댐퍼 개발에 관한 연구)

  • Jin, Chul Ho;Yoon, Young Won;Lee, Jae Hak
    • Journal of Drive and Control
    • /
    • v.15 no.1
    • /
    • pp.38-49
    • /
    • 2018
  • This research describes the development model and testing of a hybrid damper which can be applicable to a vehicle suspension. The hybrid damper is devised to improve the performance of a conventional passive oil damper using a magneto-rheological (MR) accumulator which consists of a gas accumulator and a MR device. The level of damping is continuously variable by the means of control in the applied current in a MR device fitted to a floating piston which separates the gas and the oil chamber. A simple MR device is used to resist the movement of floating piston. At first a mathematical model which describes all flows within the conventional oil damper is formulated, and then a small MR device is also devised and adopted to a mathematical model to characterize the performance of the device.

Long Life Design of SSD Test Gender by Reducing Ejecting Force (인출력 저감을 통한 SSD Test Gender의 장수명 설계)

  • Kim, Jae Kyung;Park, Hyung Suk;Lee, Ki Seok;Jeon, Euy sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.139-144
    • /
    • 2020
  • Recently, the electronic equipment industry has become active due to the continuous increase in portable storage media with high-speed information communication, and in particular, the production of SSD(Solid State Drives) for miniaturization of mobile devices and high-speed information communication has increased rapidly. When the SSD is ejecting in the SSD test gender, the necessary ejecting force must be kept constant to have a lifespan applicable to the test device. When the ejecting force increased, it leads to wear of the link for ejecting, which causes a problem in that repeated durability decreases and the ejecting of the SSD becomes impossible. In this paper, the repeated durability test analysis according to the material and the reducing ejecting force design were performed to increase the life of the test gender for SSD inspection. The wear level of the pusher head and ejector was analyzed through repeated durability tests according to the material of the pusher head. The validity of the design was verified through the ejecting force test and repeated durability test of the Test gender, which was designed by carrying out the design to reduce the size and ejecting force of the test gender.

Outer Shape Design of Rotating Medium Antenna Installed on Ship Mast (함정 마스트 장착 레이더용 회전 중형 안테나의 외부 형상 설계)

  • Cho, Ki-Dae;Kim, Ki-Wan;Kwon, Min-Sang;Hong, Seong-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.8
    • /
    • pp.843-850
    • /
    • 2012
  • To satisfy the operational requirements of surveillance radar and the operational concept of a ship combat system, an active-array-type antenna was designed using solid-state transmitters and receivers. The arrangement of the constituent electronic components of the antenna system, considerably large in size, and therefore, the antenna needs to be housed in a box. The rotational antenna system installed on a ship mast is installed in a sealed housing to protect the interior equipment from environmental conditions. The outer shape of the housing is that the antenna should be capable of rotating normally despite strong winds. Furthermore, in recent times, designs with low radar cross section (RCS) have attracted attention from the viewpoint of improving the stealth of the ship. In this light, four types of models are proposed for the outer shape design of the antenna system, and they are investigated from the viewpoint of low RCS design as well as wind load.

Physical Therapy Session Duration in patients with low Back Pain: Descriptive Research (요통 환자에 대한 물리치료방법의 적용 시간을 중심으로 한 기술적 연구)

  • Kim, Suhn-Yeop;Chae, Jung-Byung;Kwon, Jae-Hoak
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.7 no.1
    • /
    • pp.51-66
    • /
    • 2001
  • Objective: The purpose of study was to compare physical therapy duration in relation tohealth care organization system in patients with low back pain. Subjects: Subjects of this study were 759 patients who are receiving physical therapy at 56 health care organization. Methods: Data were collected by questionnaire that had been completed by patients and physical therapist for two months. Physical therapy procedures consisted of modality application, manual therapy, active therapeutic exercise, and patient education. Physical therapy session duration was investigated for each physical therapy procedure. Data were analyzed in relation to the university hospital, hospital, and clinic. Results: The mean age of subjects was $42.84{\pm}15.46$. There were no significant differences in age among three groups. The number of patients diagnosed with herniated disc were 244(32.15%) and with mechanical low back pain was 187(24.64%). The mean treatment duration per day was 53.22 minutes, and the longest treatment duration was 61.28 minutes at the university hospitals (p<0.001). The mean modality application duration was 42.17 minutes, and the longest application duration was 46.26 minutes at the university hospitals (p<0.001). The mean duration for manual therapy was 5.11 minutes, and the longest treatment duration was 5.97 minutes at clinics. The mean duration for active therapeutic exercise was 4.16 minutes. It was 7.60 minutes at the university hospitals, and 2.48 minutes at clinics. There was a significant difference in active therapeutic exercise duration between university hospitals and clinics(p<0.001). For modalities, hot packs(89.33%) and interferential current therapy(60.87%) were mostly applied. For manual therapy, Soft tissue mobilization(32.93%) and manipulation(14.10%) were mostly applied. In general, treatment application duration was longer at University hospital (p<0.05). For therapeutic exercise, exercise without equipment(18.84%) and muscle strengthening (16.73%) were mostly performed. The longest treatment duration for therapeutic exercise was 7.60 minutes at the university hospital(p<0.05). Conclusion: physical therapy session duration for low back pain was 53.22 minutes. Modality application constitutes 79%, manual therapy 10%, active therapeutic exercise 8% of total treatment duration. It is concluded that patients do not participate actively in treatment procedures.

  • PDF

Active control of pump noise of dishwashers using FxLMS algorithm (FxLMS 알고리듬 기법을 이용한 식기 세척기의 펌프 소음 능동 제어)

  • Tark, Un-su;Oh, Han-Eum;Hong, Chinsuk;Jeong, Weui-Bong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.46-54
    • /
    • 2021
  • In this paper, active noise control was performed to reduce radiated noise in the low frequency band of dishwashers. First, through an analysis of the noise environment of the dishwasher, it was confirmed that the pump noise contributed the most to the radiated noise in the low frequency band, From the result of the noise environment analysis, the reference signal was selected to be the vibration signal of the pump body. The reference signal was obtained by using the accelerometer on the pump body, which can prevent acoustic feedback. The error signal sensor was selected as a microphone located at 1 m in front of the dishwasher and 0.5 m in height. And to design the controller, the error signal and the reference signal were measured at the operational rpms of the dishwasher at 2,500 rpm, 2,600 rpm and 2,800 rpm, and the secondary path transfer function was measured. The designed controller was mounted on Digital Signal Processor (DSP) equipment, and the control performance was verified experimentally. As a result of the measurement at the 3 operational rpms, the 7th multiple component of pump operating frequency decreased by 1.93 dB, 4.43 dB, 5.15 dB per rpm, and the 12th multiple component decreased by 6.67 dB, 2.34 dB, 4.28 dB per rpm. And overall Sound Pressure Level (SPL) decreased by 0.84 dB, 2.58 dB, 1.48 dB by rpm.

On the Implementation of an Advanced Judgement Algorithm for Contact Loss of Catenary System (전차선의 집전상태 판단 알고리즘 구현)

  • Park, Young;Jung, Ho-Sung;Yun, Il-Kwon;Kim, Wonha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.850-854
    • /
    • 2014
  • Analyzing dynamic performance between pantograph and contact wire depends on mechanical and electrical conditions such as contact force, currents, aerodynamics of pantograph and tension of overhead contact wire. For the characteristic of dynamic performance between pantograph and overhead contact wire, various evaluation systems are used to measuring of the interaction of the contact line and the pantograph. Among the various methods, the contact force and percentage of arcing are intended to prove the safety and the quality of the current collection system on the train. However, these methods are only capable of measuring on the train which are installed measurement systems. Therefore in this paper, a track-side monitoring system was implemented to measure electrical characteristics from active overhead contact wire systems in order to constantly estimate current collection performance of railway operation. In addition, a method to analyze loss of contact phenomena was proposed. According to simulation results, the proposed system was capable of measuring abnormal electrical behavior of pantograph and contact wires on the track-side. The advantage of the proposed system is possible to detect loss of contact or any other electrical abnormalities of all types of trains within sections from sub to sub without the need to install any on-board equipment on trains.

A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System (특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구)

  • Jung, Heung-Soo;Kim, Min-Young;Kim, Juen-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.36-46
    • /
    • 2008
  • This paper is to study on the Construction of Test circuit and Unification of Experiment Method for high voltage gas-insulated load switch using high power testing system The high power testing system is a equipment to verify electrical and mechanical performance on electrical product. The system consist of short-circuit generator, back-up breaker, making switch, impedance, high voltage transformer, low voltage transformer, measuring and protection system, etc. Using this system, we can test related to high power, for example, short-time current test, active load Current test, magnetizing Current test, capacitive current test, closed loop current test, etc. Standards of high voltage gas-insulated load switch that is in use domestic distribution line are ES 5925-0002, IEC 60265-1, IEC 62271-1 and IEEE C 37.74, etc. In this paper, we standardized on the test procedure, organization of test circuit and analysis of measured data prescribed many difference standards, and applied this test method to 600[MVA] high power testing system. So that we can test the load switch satisfied standards.