• 제목/요약/키워드: Activated-carbon treatment

검색결과 654건 처리시간 0.025초

Removal of ciprofloxacin from aqueous solution by activated carbon prepared from orange peel using zinc chloride

  • Koklu, Rabia;Imamoglu, Mustafa
    • Membrane and Water Treatment
    • /
    • 제13권3호
    • /
    • pp.129-137
    • /
    • 2022
  • In this study, the removal of Ciprofloxacin (CPX) from aqueous solutions was investigated by a new activated carbon adsorbent prepared from orange peel (ACOP) with chemical activation using ZnCl2. The physicochemical properties of orange peel activated carbon were characterized by proximate and ultimate analysis, scanning electron microscopy, BET surface area determination and Fourier transformation infrared spectroscopic studies. According to Brunauer-Emmett-Teller isotherm and non-local-density functional theory, the cumulative surface area, pore volume and pore size of ACOP were determined as 1193 m2 g-1, 0.83 cc g-1 and 12.7 Å, respectively. The effects of contact time, pH, temperature and ACOP dose on the batch adsorption of CPX were studied. Adsorption equilibrium data of CPX with ACOP were found to be compatible with both the Langmuir and Freundlich isotherms. CPX adsorption capacity of ACOP was calculated as 181.8 mg g-1 using Langmuir isotherm. The CPX adsorption kinetics were found to be harmonious with the pseudo-second-order kinetic model. Conclusively, ACOP can be assessable as an effective adsorbent for the removal of ciprofloxacin (CPX) from aqueous solutions.

입자상 활성탄의 흡착과 재생에 의한 PCBs 오염제거 (Decontamination of PCBs by Hybrid Adsorption/Regeneration on Granular Activated Carbon)

  • 홍용표;최종하
    • 대한화학회지
    • /
    • 제46권2호
    • /
    • pp.117-124
    • /
    • 2002
  • 활성탄에 흡착되어 있는 유기질을 처리하기 위하여 역류산화반응이 개발되었고 그것에 대한 평가가 이루어 졌다. 역류산화반응이란 산소의 흐름과 반대로 이동하는 자발적인 불꽃을 이용하여 유기질을 파괴 및 제거함과 동시에 폐활성탄을 재생하는 방법이다. 본 연구를 통하여 얻어진 실험결과를 고찰해 보면, 활성탄의 질량손실과 불꽃의 온도가 산소의 흐름속도에 절대적으로 의존하였고, 재생탄의 비표면적이 거의 완전히 회복되었으며, 특히 활성탄에 흡착되어 있는 열에 안정한 PCBs를 거의 완전히 파괴 및 제거(99.99%이상)할 수 있었다.

정수처리공정에서의 입자분석 적용방안 (Application of Particle Counter in Water Treatment Process)

  • 신상희;전현숙;이찬형;배기수
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.337-342
    • /
    • 2013
  • The particle counter compared with the turbidimeter provides good precision and sensitivity and can get the characteristics of particulates effectively. The purpose of this study is to provide the application of particle counter in sand and activated carbon filters. The particle count by size could be more easily sense when the water quality is changed by the influent of high turbidity or algae. We could decide the optimal backwashing cycles and detect the efficiencies of filters by monitoring the total particle count of effluent in sand and activated carbon filters.

Dissolved Oxygen Removal in a Column Packed with Catalyst

  • Lee, Han-Soo;Hongsuk Chung;Cho, Young-Hyun;Ahn, Do-Hee;Kim, Eun-Kee
    • Nuclear Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.482-487
    • /
    • 1996
  • The dissolved oxygen removal by H$_2$-O$_2$ reaction in column packed with various catalysts wes examined. The catalysts employed were the prepared polymeric catalyst platinum on activated carbon, and Lewatit OC-1045 which is available commercially. The column experiments with the prepared polymeric catalyst showed the dissolved oxygen reduced to 35 ppb which is below the limit in feed water of power plants. This implies the likely application of the prepared catalyst for practical use. The activated carbon required the pre-treatment for the removal of dissolved oxygen, since the surface of activated carbon contains much oxygen adsorbed initially. The Lewatit catalyst exposed the best performance, however, the aged one showed the gradual loss of catalytic activity due to degradation of resin catalyst.

  • PDF

Preparation of Novel Sorbents for Gas-phase Mercury Removal

  • Lee, Si-Hyun;Rhim, Young-Jun;Park, Young-Ok
    • Carbon letters
    • /
    • 제3권4호
    • /
    • pp.187-191
    • /
    • 2002
  • In the present research, we prepared the activated carbon (AC) sorbents to remove gas-phase mercury. The mercury adsorption of virgin AC, chemically treated AC and fly ash was performed. Sulfur impregnated and sulfuric acid impregnated ACs were used as the chemically treated ACs. A simulated flue gas was made of SOx, NOx and mercury vapor in nitrogen balance. A reduced mercury adsorption capacity was obtained with the simulated gas as compared with that containing only mercury vapor in nitrogen. With the simulated gas, the sulfuric acid treated AC showed the highest performance, but it might have the problem of corrosion due to the emission of sulfuric acid. It was also found that the high sulfur impregnated AC also released a portion of sulfur at $140^{\circ}C$. Thus, it was concluded that the low sulfur impregnated AC was suitable for the treatment of flue gas in terms of stability and efficiency.

  • PDF

The Presence of Significant Methylotrophic Population in Biological Activated Carbon of a Full-Scale Drinking Water Plant

  • Kim, Tae Gwan;Moon, Kyung-Eun;Cho, Kyung-Suk
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권12호
    • /
    • pp.1774-1778
    • /
    • 2013
  • Methylotrophs within biological activated carbon (BAC) systems have not received attention although they are a valuable biological resource for degradation of organic pollutants. In this study, methylotrophic populations were monitored for four consecutive seasons in BAC of an actual drinking water plant, using ribosomal tag pyrosequencing. Methylotrophs constituted up to 5.6% of the bacterial community, and the methanotrophs Methylosoma and Methylobacter were most abundant. Community comparison showed that the temperature was an important factor affecting community composition, since it had an impact on the growth of particular methylotrophic genera. These results demonstrated that BAC possesses a substantial methylotrophic activity and harbors the relevant microbes.

Remediation of TCE contaminated groundwater by pretreated granular activated carbon

  • Heo Joong-Hyeok;Lee Ju-Young;Lee Dal-Heui;Chang Ho-Wan
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2005년도 총회 및 춘계학술발표회
    • /
    • pp.375-378
    • /
    • 2005
  • The objective of this study was to clarify the possibility of adsorption trichloroethylene (TCE) of pretreated granular activated carbon (GAC). The chemical solution used for the acidic treatment was phosphoric acid. In addition, the effect of ultrasound on GAC assessed in this experiments. It was observed that the adsorption of TCE were different based on pH value of pretreated GAC. However, natural water such as groundwater has various factors like ionic strength and hardness etc. Therefore, more laboratory work is needed to study about pretreated GAC.

  • PDF

A Development Study on High Quality Drinking Water Production by the Biological Activated Carbon/immersed Membrane Filtration System

  • Inoue, Shiro;Iwai, Tosinori;Isse, Masaaki;Terui, Taturo
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2001년도 국제 Workshop:상수원의 현황과 분리막 상수처리(Water Resource and Menbrane Water Treatment)
    • /
    • pp.155-162
    • /
    • 2001
  • Advanced drinking water production systems, which not only good quality product water, but also provide easy management and mainenance of facilities, and operate on a smaller site area, have been expected to be developed for some time. We are going ahead with a program to deveop an advanced drinking water production system, using immersed membrane filtration combined with biological activated carbon, to meet the need described above. The demonstration plant tests been conducted with surface water from the Yodo-river since Dec. 1998 to measure treatment performance, reliability, and controllability of the system. The quality of product water has consistently remained at a very high level for about 2 years under controlled conditions. Results showed that the re-circulation granular biological activated carbon could suppress the increase of membrane pressure difference and promote a reduction of dissolved organic matter. (This work has been conducted along the ACT21 Programs.)

  • PDF

Application and Development of Activated Carbon Adsorption in Wastewater

  • Zhang, DianYa;Deng, ChengXun;Deng, Xu;Yu, ZhiMin
    • 도시과학
    • /
    • 제8권2호
    • /
    • pp.19-23
    • /
    • 2019
  • With the continuous progress of modern science and technology and the rapid development of economy, with the continuous development of society, the treatment of industrial and domestic sewage has become a hot concern. Toxic substances and non-degradable pollutants in wastewater also have a great impact on the environment. This paper mainly expounds the current environmental situation and the adsorption mechanism of activated carbon. And the application and development of activated carbon adsorption in wastewater.

상수원수 내 이취미 제거효율 향상을 위한 분말활성탄 투입지점의 평가 (Evaluation on the Locations of Powdered Activated Carbon Addition for Improvement of Taste and Odor Removal in Drinking Water Supplies)

  • 김영일;이상진;배병욱
    • 상하수도학회지
    • /
    • 제21권3호
    • /
    • pp.341-348
    • /
    • 2007
  • The efficiency of powdered activated carbon (PAC) for removing taste and odor (T&O) in drinking water supplies is dependent on the contact time, quality of mixing, and the presence of competing compounds. All of these are strongly influenced by the stage in the treatment process at which the PAC is added. In conventional water treatment plants (WTPs), PAC is commonly added into the rapid mixing basin where chemicals such as coagulants, alkaline chemicals, and chlorine, are simultaneously applied. In order to prevent interference between PAC and other water treatment chemicals, alternative locations for addition of PAC, such as at transmission pipe in the water intake tower or into a separated PAC contactor, were investigated. Whatever the location, addition of PAC apart from other water treatment chemicals was more effective for geosmin removal than simultaneous addition. Among several combinations, the sequence 'chlorine-PAC-coagulant' produced the best result with respect to geosmin removal efficiency. Consequently, when PAC has to be applied to cope with T&O problems in conventional WTPs, it is very important to prevent interference with other water treatment chemicals, such as chlorine and coagulant. Adequate contact time should also be given for adsorption of the T&O compounds onto the PAC. To satisfy these conditions, installation of a separated PAC contactor would be the superior alternative if there is space available in the WTP. If necessary, PAC could be added at transmission pipe in the water intake tower and still provide some benefit for T&O treatment.