• Title/Summary/Keyword: Activated sludge process

Search Result 415, Processing Time 0.024 seconds

Degradation of Phenolic Compounds in a Slurry Reactor (슬러리 반응기를 이용한 페놀류 화합물의 분해거동)

  • Lee, Jamyoung;Jung, Yonkyu;Lee, Taejin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.949-957
    • /
    • 2000
  • This study investigates the remediation of the phenol or PNP(p-Nitrophenol) contaminated soils in a slurry reactor by a pure culture, P-99. The application of a pure culture for the phenol decontamination make the degradation rate three times faster than that of the mixed activated sludge. The destruction of 300 mg/L phenol was completed in 26 hours. As 1 mg of phenol was added, 0.1457 mg of microorganism was grown in the medium. The pure culture could not utilizes PNP, one of the xenobiotics, as a growth substrate. When the bacteria was induced by phenol enrichment medium. PNP could be effectively transformed with cometabolic process. The induction of the bacteria requires 1 mg of phenol for the destruction of 0.027 mg PNP. When PNP concentration in the medium contained phenol and PNP increased. the degradation rate of phenol was decreased. The degradation rate of phenol and PNP in the slurry reactor was about two times faster than in the reactor without slurry because of higher dissolved oxygen supply in the aqueous phase and adsorption on the surface of the soil.

  • PDF

Establishment of Resilient Infrastructures for the Mitigation of an Urban Water Problem: 2. Robustness Assessment of Structural Alternatives for the Problems of Water Pollution (도시 물 문제 저감을 위한 회복탄력적 사회기반시설 구축: 2. 수질오염 문제 구조적 대안의 내구성 평가)

  • Jung, Jihyeun;Lee, Changmin;An, Jinsung;Kim, Jae Young;Choi, Yongju
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.3
    • /
    • pp.182-188
    • /
    • 2016
  • This study evaluated structural alternatives for managing water quality problems by reinterpreting and then applying the robustness-cost index (RCI) for urban flood problems. Cases of endogenous hormone pollution in treated sewage and proliferation of protozoa in intake-water were chosen as representative examples because they have different types of regulation standards for the treatment. Current facilities and structural alternatives with robustness indices (RIs) greater than unity were determined to be robust. The RI was combined with the cost index (CI) to obtain the RCI values. For the endogenous hormone pollution in treated sewage, a human-oriented estrogen $17{\beta}$-estradiol was selected as a target pollutant. The RI and RCI values for a structural alternative, extension of the current sewage treatment facility for advanced treatment, were greater than the values for the current practice of conventional activated sludge process. For the intake-water pollution by protozoa, UV and ozone disinfection facilities were evaluated for inactivation of Cryptosporidium parvum. The RCI values for ozone disinfection were greater than those for UV disinfection. Based on the results and the logics involved in the calculation of RCI for water quality issues we studied, we proposed procedures for establishing and implementing structural alternatives for the restoration from and prevention of outbreaks of water quality problems.

Survey and model development of the mechanization for swine farming (양돈농가의 기계화 실태분석 및 모델개발)

  • 이성현;박원규;강창호;오권영
    • Journal of Bio-Environment Control
    • /
    • v.7 no.2
    • /
    • pp.91-108
    • /
    • 1998
  • This study was carried out to survey basic information of swine farms on the machine holdings. facility type. management of manure by farm scale and operation, and then to develop the mechanization model. Manual feeding was common for sows and nursing sows. but automation feeding was normally furnished for weaners. growing pigs and castrated male pigs. Water supplies was completely automated for all of the surveyed swine farms. Fully mechanized and automated system would not be feasible and affordable for the small scale farms breeding less than 500 heads. Because the environmental control for the nursing sows and weaner was important, some swine houses were constructed with the windowless type. However, the furnished rates ranged from 22.2% to 44.4% of the surveyed nursing sow and weaner houses at the farm scales. In the future, a computerized ventilation system would be commended for the efficient use of heat energy and to maintain the desirable temperature of swine buildings. Over-investment for large scale farm and over-crowded pigpen of small farm would cause wasting construction expenses and spreading epidermic diseases Hence, the size of swine building should follow the recommended scale. The fermentation drier was recommended for the manure management. Urine could be recycled or discharged after treating by the activated sludge process.

  • PDF

Changes in the Organic Compounds and Molecular Weight Distribution in Pig Wastewater by Each Treatment Steps. (양돈폐수의 정화처리 과정별 유기물질 성분과 분자량 분포 변화 연구)

  • 최희철;이덕수;권두중;강희설;유용희;연규영;최영수;곽정훈;최동윤
    • Journal of Animal Environmental Science
    • /
    • v.10 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • These experiments were conducted to analyze the characteristics of organic compounds and molecular weight distribution according to the treatment steps of purifying system for pig wastewater. The results obtained are summarized as follow. 1. Raw pig wastewater contained 31 kinds of organic compounds such as acetic acid, 2-butanone, hexane, chloroform, propionic acid, butanoic acid etc. 2. After ozone treatment, 13 kinds of organic compounds such as ethene, pentane, 2-methylopropanal, hexane, furan and so on were detected in the wastewater. 3. After $TiO_2$ treatment, 12 kinds of organic compounds such as ethene, hexane, chloroform, 1-decene, silane and so on were detected from the effluent. 4. After both ozone and $TiO_2$ treatment, portion of molecular weight smaller than 500 Daltons and molecular weight between 500 to 1,000 Daltons in the wastewater increased.

  • PDF

Simultaneous Nitrification and Denitrification using Submerged MBR packed with Granular Sulfur and Non-woven Fabric (부직포 및 황 충진 MBR을 이용한 포기조내 동시 질산화/탈질에 관한 연구)

  • Moon, Jin-Young;Hwang, Yong-Woo;Park, Ji-Hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.439-446
    • /
    • 2009
  • This study was performed to evaluate SND(simultaneous nitrification and denitrification)efficiency, nitrogen removal efficiency and filtration function of non-woven fabric by using submerging MBR packed with granular sulfur covered with non-woven fabric filter. Synthetic wastewater was used as influent wastewater. Concentration of $NH_4{^+}-N$ in influent was maintained about 40 mg/L and the experiment was performed in four phases according to the flow rate. Nitrogen loading rate divided four phases ranging from $0.04 kg\;NH_4{^+}-N/m^3-day$ to $0.16 kg\;NH_4{^+}-N/m^3-day$. As a result, the maximum $NH_4{^+}-N$ removal rate was accomplished at $0.142 kg\;NH_4{^+}-N/m^3-day$ in nitrogen loading of $0.147 kg\;NH_4{^+}-N/m^3-day$. Nitrification efficiency was higher than 95% in all phases. $NO_3{^-}-N$ loading rate was adjusted ranging from $0.22 kg\;NO_3{^-}-N/m^3-day$ to $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal rate was accomplished up to $0.71 kg\;NO_3{^-}-N/m^3-day$ in $NO_3{^-}-N$ loading of $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal efficiency was 95% in $NO_3{^-}-N$ loading of $0.22 kg\;NO_3{^-}-N/m^3-day$. T-N removal rate was 90% and concentration of T-N in effluent was 3.7 mg/L in T-N loading rate of $0.039 kg\;NO_3{^-}-N/m^3-day$. In this study, TMP in reactor with and without non-woven fabric filter were observed to define fouling of hollow-fiber membrane module. Reaching time to standard washing pressure(22 cm Hg) of two reactors were 29 days with non-woven fabric But the reactor without non-woven fabric reached standard washing pressure only after 4 days. Accordingly, non-woven fabric was demonstrated the superiority as a filtration ability. With high nitrogen removal rate and decreasing of fouling of membrane, MBR packed with granular sulfur covered with non-woven fabric filter submerging in activated sludge aeration tank can be used as an advanced treatment process.

Isolation of Microorganisms and Development of Microbial Augmentation for Treatment of Paper Mill Wastewater (제지폐수 처리용 미생물의 분리 및 복합 미생물제제의 개발)

  • Kang, Dae-Ook;Suh, Hyun-Hyo
    • Journal of Life Science
    • /
    • v.21 no.4
    • /
    • pp.554-560
    • /
    • 2011
  • This study was performed to investigate the effects of microbial augmentation on the biological treatment of paper mill wastewater. Three bacteria (KN11, KN13, KN27) capable of degrading aromatic compounds and a bacterial strain (GT21) producing an extracellular cellulase were isolated from soil and wastewater by selective enrichment culture. Through morphological, physiological, and biochemical taxonomies, isolated strains of KN11, KN13, KN27, and GT21 were identified as Acinetobacter sp., Neisseria sp., Bacillus sp., and Pseudomonas sp. and named Acinetobacter sp. KN11, Neisseria sp. KN13, Bacillus sp. KN27, and Pseudomonas sp. GT21, respectively. For analysis of non-biodegradable and chemical oxygen demand (COD)-increasing matter in a paper mill wastewater, we utilized GC/MS to detect aromatic compounds and their derivatives containing several substituted functional groups. The microbial augmentation, J30 formulated with the mixture of bacteria including Acinetobacter sp. KN11, Neisseria sp. KN13, Bacillus sp. KN27, and Pseudomonas sp. GT21, was used for the treatment of paper mill wastewater. The optimum temperature and pH for COD removal of the microbial augmentation, J30, were $30^{\circ}C$ and 7.5, respectively. For evaluation of the industrial applicability of the microbial augmentation, J30 in the pilot test, treatment efficiency was examined using paper mill wastewater. The microbial augmentation, J30, showed a COD removal rate of 87%. On the basis of the above results, we designed the wastewater treatment process of the activated sludge system.

Water Reuse of Sewage Discharge Water Using Fertilizer Drawn Forward Osmosis - Evaluating the Performance of Draw Solution - (비료 유도용액의 정삼투를 이용한 하수처리수의 재이용 - 유도용액의 성능 평가 -)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.26 no.2
    • /
    • pp.108-115
    • /
    • 2016
  • This study is to evaluate the performance of draw solutions in the water reuse of sewage discharge water using fertilizer drawn forward osmosis. Feed water used in all experiments was the effluent from secondary sedimentation tank in activated sludge process. Considering osmotic pressure, solubility, and pH, $NH_4H_2PO_4$, KCl, $KNO_3$, $NH_4Cl$, $(NH_4)_2HPO_4$, $NH_4NO_3$, $NH_4HCO_3$, and $KHCO_3$ were screened from a comprehensive lists of fertilizer. Their performances were evaluated in terms of water permeate flux and reverse solute flux. KCl showed the highest average water flux followed by $NH_4Cl$, $NH_4NO_3$, $KNO_3$, $KHCO_3$, $NH_4HCO_3$, $NH_4H_2PO_4$, and $(NH_4)_2HPO_4$. Using KCl as draw solution, the average water permeate flux was 13.49 LMH. There was no big difference in osmotic pressure between the effluent from secondary sedimentation tank and deionized water. $NH_4H_2PO_4$ showed the lowest reverse solute flux followed by $NH_4Cl$, $(NH_4)_2HPO_4$, $KNO_3$, $NH_4HCO_3$, and $NH_4NO_3$. Using $NH_4H_2PO_4$ as draw solution, the reverse solute flux was $4.96{\times}10^{-3}mmol/m^2{\cdot}sec$.

Evaluation and Comparison with Standard 48 hr Acute Bioassay and High Temperature Rapid Toxicity Test for Sewage Toxicity Test (하수의 독성평가를 위한 표준독성시험법과 온도증가 단기독성평가법의 비교 평가)

  • Lee, Sang-Ill;Jun, Byong-Hee;Weon, Seung-Yeon;Kim, Yi-Jung;Kim, Keum-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.191-197
    • /
    • 2005
  • A new method, ToxTemp (TOXcity test based on TEMPerature control) using Ceridaphnia dubia was applied to evaluate the toxicity of insecticide materials and compared with the standard 48 hr acute bioassay. BPMC, diazinon and fenitrothion may cause the inhibition to the biological process in sewage treatment plant and need to detect toxicity within short contact time. The ToxTemp method showed sensitive detection with more shorter contact of 1-1.5 hr time than that of the standard 48 hr acute bioassay. To evaluate toxicity of real wastewater/sewage, the inhibition rate of nitrification and oxygen uptake rate (OUR) using activated sludge, the standard 48hr acute bioassay and ToxTemp method using C. dubia were compared, respectively. On the basis of the inhibition rate of nitrification, the OUR test showed the less sensitive results at the relatively strong toxic sewage. On the other hands, the standard 48hr acute bioassay and ToxTemp method using C. dubia represented the toxicity of each wastewater/sewage with high sensitivity. Even the slightly low (about 1.5%) sensitivity, the ToxTemp method showed the high applicability to the real site of sewage treatment plant.

Sampling Survey of Hazardous Water Pollutants in Industrial Wastewater Treatment Plants (산업단지 폐수종말처리장의 특정수질유해물질 유입 및 방류 현황조사)

  • Park, Soo-Hyung;Jung, Jin-Young;Kim, Jaehoon;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.10
    • /
    • pp.590-595
    • /
    • 2015
  • Sampling campaigns were conducted for hazardous chemicals and heavy metals in influents and effluents of industrial wastewater treatment plants (WWTPs) in Korea for best management practices (BMPs) of those pollutants through the plants and the receiving water bodies. Twenty seven WWTPs, receiving wastewater from industrial complexes and treating more than $2,000m^3/day$, were selected for the sampling campaign. Influents and effluents of each WWTPs were sampled once a month (total three times per plant) between July and September, 2012, and analyzed for 22 hazardous water pollutants among 28 regulated for effluents limits in Korea. Concentrations of mercury, arsenic, 1,1-dichloroethylene, and benzene in the influents were relatively higher; concentrations of mercury and arsenic in effluents were relatively higher than those of other pollutants. Most of the hazardous chemicals and heavy metals were removed (including phase transfer) more than 60% through the treatment processes except for selenium (30% removal) and 1,4-dioxane (18% removal).

Development of New BNR Process Using Fixed-Biofilm to Retrofit the Existing Sewage Treatment Plant (고정생물막을 이용한 기존 하수처리장의 생물학적 영양염 제커 신공정개발)

  • Kim, Mi-Hwa;Lee, Ji-Hyung;Chun, Yang-Kun;Park, Tae-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1093-1101
    • /
    • 2000
  • The object of this study was to develop new BNR process using fixed-biofilm which could be applied to retrofit the existing wastewater treatment plant or to introduce as tertiary treatment plant. To achieve complete denitrification from typical raw sewage in Korea, external carbon source must be supplied because $SCOD_{cr}/T-N(NH_4{^+}-N+NOx-N)$of raw sewage was lower than other countries. In this study, the ratio of $SCOD_{cr}/NH_4{^+}-N$ was 2.49 and the influent $NH_4{^+}$-N concentration during the experimental period was varied from 25 to 37 mg/L. To enhance nitrogen removal from the sewage, the two processes using fixed biofilm were adopted as R-Hanoxic/mid.settler/aerobic/anoxic/ aerobic) and R-2(aerobic/mid.settlerlanoxic/anoxic/aerobic), respectively. In the comparison of $NH_4{^+}$-N, T-N effluent quality and T-N removal efficiency in both processes without external carbon source, R-1 process was better than R-2 process for nitrogen removal from raw sewage. With respect to $SCOD_{cr}$/NOx-N ratio and total nitrogen removal in each anoxic reactor of two processes, R-1's was more effective than R-2's for distributing organic matters of raw sewage. In the both processes using fixed biofilm, the amount of required alkalinity to remove unit $NH_4{^+}$-N were 5.18 and 5.76($g{\cdot}CaCO_3/g{\cdot}NH_4{^+}-N_{removed}$), respectively and were lower than activated sludge BNR process(7.14).

  • PDF