• Title/Summary/Keyword: Activated Sludge

Search Result 789, Processing Time 0.033 seconds

Effects of Landfill Leachate on the Treatment of Municipal Wastewater (매립지 침출수가 도시하수처리에 미치는 영향)

  • Jang, Ji-Hee;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.2
    • /
    • pp.117-123
    • /
    • 1996
  • A bench-scale continuous activated sludge system was operated in order to study the effects of solid waste landfill leachate on municipal wastewater treatment. The leachate sample was collected from Nanjido landfill. During the 7 weeks of operational period, the leachate content in the influent fed to the system was increased stepwise from 3% to 5% and 7%. The solids retention time was the major process control parameter, and it was 10 days. With the municipal wastewater alone, COD removal was 75%. The removal percents, however, decreased to 60% and 45% when the leachate content was 3% and 7%, respectively. For the wastewater spiked with the leachate, the sludge production was higher than for the municipal wastewater alone. Sludge settleability determined by SVI deteriorated with the increase of leachate content. The specific oxygen uptake rate, however, was measured higher as leachate content increased.

  • PDF

Anaerobic Digestion Biochemical Sludge Produced from Municipal Sewage Treatment Process (하수처리시설에서 발생된 약품 잉여슬러지의 혐기성 소화 특성)

  • Cho, Sang Sun;Kang, Ho;Lim, Bong Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.561-569
    • /
    • 2014
  • This study was carried out to get the characteristics of anaerobic digestion for chemical/biological sludge produced from municipal sewage treatment plant for phosphorus. Anaerobic mesophilic batch tests showed that the ultimate biodegradability of waste activated sludge showed 31%, PACl sludge 24%, Alum sludge 26%, respectively. At the S/I 1.0, 75% of total biodegradable volatile solids (TBVS) of waste activated sludge was degraded with an initial rapid decay coefficient, k1 of $0.1129day^{-1}$ and 74% of TBVS of PACl sludge with k1 of $0.0998day^{-1}$, and 76% of TBVS of Alum sludge with k1 of $0.1091day^{-1}$ for 20 days. During the operation of SCFMRs, the 3 reactor (Control, PACl, Alum) pH maintained 6.7~7.0 and the reactor alkalinity maintained 1,800~ 2,200 mg/L as $CaCO_3$. The average biogas production rates of SCFMRs fed with PACl sludge and Alum sludge were 0.089 v/v-d and 0.091 v/v-d, respectively, which was 27~28% lower than that of the control (0.124 v/v-d) at an HRT (hydraulic retention times) of 20 days. And the methane content during the operation ranged 70~76% in 3 reactor. The average TVS removal efficiency of SCFMRs fed with PACl sludge and Alum sludge were 19.6% and 19.9%, respectively, at an HRT of 20 days, which showed 4% lower than that of the control (23.8%). The average BVS removal efficiency of SCFMRs fed with PACl sludge and Alum sludge were 25.8% and 26.9%, respectively, at an HRT of 20 days, which was 8~9% lower than that of the control (34.5%).

Adsorption Characteristics of Benzene by Carbonized Cast (탄화분변토를 이용한 Benzene의 흡착특성)

  • 김재홍;손희정;김미룡
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.1
    • /
    • pp.97-102
    • /
    • 1999
  • This study was carried out view that reuse of sludge of adsorbent for benzene in carbonized cast compare with activated carbon. Not only the carbonized cast is good than carbonized carbon in cation exchange capacity and 12 adsorption capacity, but also benzene adsorption capacity is no differences compare to activated carbon. As results, benzene adsorption capacity of carbonized cast and activated carbon are decreased as temperature increase($25~70^{\circ}C$).It is compatible in Lamgmuir model. Therefore, carbonized cast is applied general adsorbent. From experimental results and data regression, in model concerning effect of temperature, relative errors between the experimental data and those calculated by the model are within the range of 1.2~7.8%. In relative humidity effect (RH 0.25~0.50) of benzene adsorption, modified Freundlich model : $QB_{enzene}{;\}QB_{enzene},{\}_{RH=0}=1-kRH^{IN}$, relative errors between the experimental data and those calculated by the model are within are range of 0.5-5.1%. The constants k and l/n in equation were found to be 1.25, 1.89 in carbonized cast.

  • PDF

Thickening of Activated Sludge Using Low Pressure Flotation Pilot System (파일롯 규모의 저압형 부상장치를 이용한 하수슬러지 농축에 관한 연구)

  • Kim, Ji Tae;Oh, Joon Taek;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.3
    • /
    • pp.172-177
    • /
    • 2014
  • Low pressure air flotation (LAF) pilot plant for sludge thickening was installed in Chung Nam N.S. municipal waste water treatment plant to verify its application possibility. Effects of operating conditions such as coagulant dosages and microbubble water ratio on thickening of the mixed sludge were examined. Microbubbles which were generated in the chamber of $1.5kgf/cm^2$ by high speed collision method with foaming agent were used to float sludge. Solid loading of $30kg/m^2/hr$, solid contents in thickened sludge of 60,300 mg/L and SS removal efficiency of 99% were obtained through long period operating LAF in conditions of mixed sludge concentration of 14,400 mg/L, coagulant dosage of 27.6 mg/L, foaming agent addition of 4.0 mg/L and microbubble water injection ratio of 9.7%.

A study on an intermittent aeration membrane bioreactor system using ammonia sensor to decrease energy consumption and sludge concentration by tubular membrane (암모니아 센서를 이용한 간헐폭기 Membrane bioreactor공정에서의 전력비 저감과 관형막을 이용한 슬러지 농축에 관한 연구)

  • Kang, Heeseok;Lee, Euijong;Kim, Hyungsoo;Jang, Am
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.161-170
    • /
    • 2014
  • It is essential to decrease energy consumption and excess sludge to economically operate sewage treatment plant. This becomes more important along with a ban on sea dumping and exhaustion of resource. Therefore, many researchers have been study on energy consumption reduction and strategies for minimization of excess sludge production from the activated sludge process. The aeration cost account for a high proportion of maintenance cost because sufficient air is necessary to keep nitrifying bacteria activity of which the oxygen affinity is inferior to that of heterotrophic bacteria. Also, additional costs are incurred to stabilize excess sludge and decrease the volume of sludge. There were anoxic, aerobic, membrane, deairation and concentration zone in this MBR process. Continuous aeration was provided to prevent membrane fouling in membrane zone and intermittent aeration was provided in aerobic zone through ammonia sensor. So, there was the minimum oxygen to remove $NH_4-N$ below limited quantity that could be eliminated in membrane zone. As the result of this control, energy consumption of aeration system declined by between 10.4 % and 19.1 %. Besides, we could maintain high MLSS concentration in concentration zone and this induced the microorganisms to be in starved condition. Consequentially, the amount of excess sludge decrease by about 15 %.

Estimation of polycyclic aromatic hydrocarbons emission from sewage sludge of sewerage treatment plants in Korea

  • Kim, Dong-Hwan;Hwang, Jong-Seob;Lee, Min-Hee;Ok, Gon
    • Journal of Environmental Science International
    • /
    • v.12 no.11
    • /
    • pp.1167-1171
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PAHs) are an important group of organic contaminants present in sewage sludge, due to their persistence, toxic, bioaccumulative and long range transfer. These characters make themselves as Persistent Organic Pollutants(POPs) in Long Range Transboundary Air Pollutions convention(LRTAP) of Europe. A method of the gas chromatographicmass spectrometric (GCMS) determination of PAHs present in sewage sludge was developed and applied to analyzed samples from five sewerage treatment plants (SWTPs), having different treatment types. PAHs were extracted from freeze-dried samples by toluene 16 hours in a soxhlet extraction system. The sludge extracts were cleaned-up by an activated silica gel column chromatography. The sum of the 16 US Environmental Protection Agency PAHs sewage sludge samples varied from 2.44 to 4.82 $\mu\textrm{g}$/g. Concentration of emission carcinogen PAHs(PAHcarc), such as Benzo(a)anthracene, Benzo(b)f1uoranthene, Benzo(k)f1uoranthene, Benzo(a)pyrene, Dibenzo(a,h)anthracene and Indeno( 1,2,3-cd)pyrene ranged from 0.62 to 1.03 $\mu\textrm{g}$/g. The total amount of PAHs emission from sewage sludge in Korea was calculated as a top-down approach. PAHs and $\Sigma$PAHcarc from sewage treatment plants had emitted to environment by several pathway. The highest amount of emission to the environment was remarked in the ocean dumping(PAHs and $\Sigma$PAHcarc emissions were 1155.95 kg/year and 5040.32 kg/year, respectively).

Removal Characteristics of Total Coliforms in a Rotating Activated Bacillus Contactor Process (회전식 부착 바실러스를 이용한 하수고도처리 공정에서의 총대장균군 제거 특성)

  • Kim, Eung-Ho;Cho, Yeon-Je;Park, Seong-Joo;Shin, Kwang-Soo;Yim, Soo-Bin;Park, Hyun-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.73-78
    • /
    • 2005
  • This study was performed to examine the disinfection capability of a Rotating Activated Bacillus Contactor (RABC) system, in which the predominant species, Bacillus sp. was expected to have a removal or inactivation effect of total coliforms. In a settling test with mixtures of E. coli and Bacillus sp., a high removal of E. coli was observed at $20{\sim}40^{\circ}C$, while insignificant removal at $10^{\circ}C$. In a batch test, a 4.5% addition of Bacillus sp. to activated sludge considerably enhanced the removal effect of total coliforms, indicating Bacillus sp. played an important role in improving the settlability of the sludge and coliforms. In a pilot scale RABC system, the concentration of total colifroms reduced remarkably in the settling tank, suggesting that total coliforms in the RABC process were eliminated through coagulation and precipitation, probably due to extracellular polymeric substance (EPS) of Bacillus sp. The fraction of Bacillus sp. in the total cell count in the RABC process was in the range of 4.5%~6.3%. The majority (75%) of the Bacillus sp. in the RABC process was Bacillus subtilis which is known to enhance coagulation and precipitation by producing EPS. Hence, an adoption of a RABC process might be able to eliminate the disinfection unit process from a wastewater treatment system.

Membrane-Coupled Sequencing Batch Reactor System for the Advanced Treatment of Rural Village Sewage (막결합 연속회분식 반응기를 이용한 농촌마을 하수의 고도처리)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.24 no.1
    • /
    • pp.20-30
    • /
    • 2014
  • A membrane-coupled sequencing batch reactor (MSBR) was used for the advanced treatment of rural village sewage which is very low C/N ratio. The effect of powdered activated carbon, aeration rate, and external organic material loadings on the treatment efficiency and filtration performance were investigated in sequencing batch reactor, in which a flat-sheet type microfiltration membrane with a pore size of $0.4{\mu}m$ was submerged. At the initial operation (within 54 days) MLSS concentration, and the removal efficiencies of COD, T-N, and T-P were increased with the increase of C/N ratio. After 89 days the removal efficiencies of COD, T-N, and T-P were 97.1%, 75.0%, and 48.3%, respectively. Suspended solid-free effluent was obtained by membrane filtration. The T-P removal was relatively low because of depending on the amount of excess sludge wasting. During the operation of MSBR with powdered activated carbon, the particle size of the sludge reduced by the increase of collision frequency and mixing intensity. In comparison with MSBR without powdered activated carbon, TMP of MSBR with that was significantly elevated.

Thermophilic Sewage Sludge Digestion by Anaerobic Sequencing Batch Reactor (고온 협기성 연속회분식 공정에 의한 도시하수슬러지 소화)

  • 허준무;박종안;이종화;손부순;장봉기
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.3
    • /
    • pp.130-138
    • /
    • 1999
  • The feasibility of municipal sewage sludge digestion was investigated by using thermophilic anaerobic sequencing batch reactor(ASBR). One-day settle time was enough for the high performance of solid-liquid separation. The conversion of semi-continuous mode to sequencing batch mode is easily achieved without any adverse effects, although the large amount of sludge equal to the volume ratio of 0.3~06 to reactor volume was added in the feed step of the start-up. The ASBRs had higher conversion capability of organics to biogas than the control reactor. Gas yields of the ASBRs were increased by the average of 50% over the control reactor across a range of hydraulic retention time(HRT)s from 10days to 5days. The thermophilic reactors showed higher gas production than mesophilic reactor. Removal efficiencies of organic matter exceeded 80% on the basis of supernatants, except that at the reactor. Solid-liquid separation was essential in the performance of the ASBR, especially, at the lower HFT. The ASBRs were highly efficient in the retention of activated biomass within the reactor. thus compensating for increased equivalent organic loading rate through increased solids retention times followed by the increased solids, while maintaining shorter HRTs.

  • PDF

Process variations in SBR and BS-SBR treatment (SBR 및 BS-SBR 처리의 공정변화 연구)

  • 양형재;정윤철;신응배
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.1
    • /
    • pp.59-68
    • /
    • 1997
  • The main purpose of this study was to determine effects of BS-SBR compared with SBR on the removal of soluble organics and sludge separation. In the BS-SBR process, soluble organics were removed by suspended activated sludge as well as biological fixed films and these two processes occurred simultaneously in one tank. The removal efficiency of soluble COD in the BS-SBR, approximately 97% in both 1 and 3-cycle/d was higher than for SBR. The BS-SBR process was very efficient for SS removal. The averaged SS concentration were 4.8 mg/l over the operation period, the daily SS values were consistently below 10 mg/l in both of 1-cycle and 3-cycle a day. The sludge settling characteristics in BS-SBR were totally different from SBR's. The sludge, dark brown, was well flocculated and its floc size was visible larger than the SBR's.

  • PDF