• 제목/요약/키워드: Activated Sludge

검색결과 789건 처리시간 0.026초

혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I) (Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I))

  • 이민규;서근학
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.123-123
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

회전매체를 가진 완전혼합 활성슬러지/Solid Contact 공법을 이용한 하수처리에 관한 연구 (Sewage Treatment using Moving Media Complete Mixing Activated Sludge/Solid Contact Process)

  • 김홍태
    • 한국농공학회지
    • /
    • 제35권4호
    • /
    • pp.67-75
    • /
    • 1993
  • This study was carried out to investigate the applicability of Solid Contact Process for the improvement of Moving Media Complete Mixing Activated Sludge(MMCMAS) effluents. Laboratory MMCMAS Reactor and MMCMAS/Solid Contact were operated at the hydraulic loading of 122~340 L/m$^2$/d. The conclusions from this study were as follows ; The addition of Solid Contact tank to the MMCMAS reactor has increased the SCOD and SBOD removal efficiencies of 4 to 67% and 2 to 41%, respectively. In addition, the increments of nitrification rates were about 13 to 46%. It was also observed that the addition of Solid Contact tank has greatly increased the organic removal efficiencies at the higher hydraulic loading rates and also decrement of sludge production rates was 0.1 gVSS/gBODrem. It was therefore concluded that the addition of Solid Contact tank could have polished the effluent of MMCMAS at the higher hydraulic loading rates.

  • PDF

고정화 미생물 반응조의 운전특성 및 생활하수처리 적용 (Operational characteristics and application of reactor using entrapped microorganism in the sewage treatment)

  • 차수길;이병헌;정승현
    • 한국환경보건학회지
    • /
    • 제28권1호
    • /
    • pp.79-84
    • /
    • 2002
  • Entrapped media with cellulous triacetate in which activated sludge was applied to induce operating factors and sewage treatment on site. The results are summarized as follows; The treatment efficiency of entrapped media is 92%, 90% and 80% at the size of 5mm, 7mm, and 12mm, respectively. Also, treatment efficient rate was increased by the packed amount of media in less than 30 % packed, while in more than 40 % packed that was decreased. It takes 10 day to reach the steady states and it is less than the existing activated sludge method. The slopes of oxygen consumption rate are almost parallel both in the entrapped media and free sludge. When organic loading rate is less than 1.0 kg/m$^3$ㆍd on site, it is achieved good removal rate independent of changes of loading rate.

OSA 공정을 이용한 하수슬러지 감량화 및 질소제거 가능성 평가 (Estimation of Sludge Reduction and Nitrogen Removal Possibility using OSA Process)

  • 주재영;윤수철;남덕현;박철휘
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.497-503
    • /
    • 2008
  • The Oxic-Settling-Anaerobic(OSA) process is a modified activated sludge processes for sludge reduction. It is evaluated that the sludge production in OSA process can decrease to 88% because of biomass decay and kinetic parameter($Y_H$ 0.237mgVSS/mgCOD, $b_H$ $0.195d^{-1}$) in anaerobic reactor, when compared with CAS process. However, it has problems caused by sludge reduction such as increase of nutrient loading. In case that the anoxic condition through the introduction of the intermittent aeration for the enhancement of nitrogen removal ability build up and enough rbCOD is suppled, maximum 88% of nitrogen is removed in the OSA process. If the OSA process optimizing the intermittent aeration cycle is applied to the separate sewage system with high rbCOD fraction, it can be converted to advanced process in terms of the sludge reduction and nitrogen removal, simultaneously.

제지산업의 지속가능한 처리공정을 위한 제지슬러지 재활용 기술

  • 임미희;이종규;남성영;안지환
    • 세라미스트
    • /
    • 제14권2호
    • /
    • pp.7-14
    • /
    • 2011
  • This paper has investigated physicochemical properties and conventional and environmental-friendly treatment methods of paper mill sludge to emphasize the importance and necessity of the sludge recycling. The paper mill sludge generally shows high contents of calcium and water, and is mostly discharged by landfill after incineration process rather than being recycled due to technical or economical problems. In recent years, however, several possible methods for recycling the paper mill sludge have been suggested for its sustainable process as follows; compost, raw material for the construction and paper industry, new energy source for reducing fossil fuel use and raw material of activated carbon for treating paper mill wastewater. Thus the authors suggest that practical recycling technologies of the paper mill sludge must be developed for substantiality in the paper industry through comprehending physicochemical compositions and generation status of the sludge and actively performing various related studies. Furthermore, this investigation could be used as preliminary information for the study on recycled paper development using paper mill sludge incineration ash.

  • PDF

슬러지의 탈수성(脫水性)에 대한 농도(濃度)의 영향(影響)과 케이크 폐색현상(閉塞現象)의 해석(解析) (Effect of sludge concentration on sludge dewaterability and cake clogging analysis)

  • 권재현;박중현
    • 상하수도학회지
    • /
    • 제10권1호
    • /
    • pp.85-95
    • /
    • 1996
  • Although the specific resistance to filtration is the most frequently employed means for characterizing dewaterability of a sludge, it presently is not possible to design nor to prediet performance of dewatering facilities using traditional linearized parabolic filtration equation, that is, the specific resistance model because of theoretical and practical inadequacies of the concept. Limitations of the specific resistance model reflect the need to examine fundamental sludge properties and filtration behaviors affecting dewaterability. From this study, two major limitations of the specific resistance model were noted. First, specific resistance values are very dependent on the sludge concentration because of the variations of particle size distribution and cake clogging to occur when surface area mean diameter is less than $25{\mu}m$ for activated sludge, $18{\mu}m$ for water treatment plant sludge. Second, nonparabolic filtration behavior can result from cake clogging, caused by the migration of fine particles into the cake pores, accelated by skin effect with highly compressible sludges.

  • PDF

전기분해를 이용한 하수 슬러지 감량 (Volume Reduction of Waste Water Sludge using Electrolysis)

  • 이병헌;방명환;김건하
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.264-270
    • /
    • 2006
  • In this research, volume reduction of activated sludge using electrolysis was studied to find an optimum condition using lab scale experiments. Wasted sludge was treated by electrolysis with controlling current density, chloride concentration, electrode distance, and reaction time. Volume of return sludge was reduced by 9.79% in average while maximum was 16.7%. Sludge volume reduction efficiency was affected by current density and reaction time. It was reversely proportional to the electrode distance. Especially current density was effective on the system performance significantly. Electric conductivity, salinity and COD were increased by electrolysis implying sludge disintegrated and converted to COD in part. An empirical equation for total solid removal efficiency by electrolysis was proposed by multiple linear regression analysis as: $TS_{rem}$(%) = 5.534 ${\times}$ current density (A/l) + 0.178 ${\times}$ reaction time (m) + 2.758.

Application of a Thermophilic Aerobic Digestion Process to Industrial Waste Activated Sludge Treatment

  • Kim, Young-Kee;Eom, Yong-Suk;Oh, Byung-Keun;Lee, Won-Hong;Choi, Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권4호
    • /
    • pp.570-576
    • /
    • 2001
  • Thermophilic aerobic bacteria were applied in the degradation of industrial waste activated sludge (WAS) on a laboratory scale expreiment. The performance of digestion was estimated by measuring the reduction of total suspended solids (TSS), dissolved organic carbon (DOC), and total organic carbon (TOC). Among three strains of Bacillus stearothermophilus and three strains of Thermus species, B. stearothemophilus ATCC 31197 showed the best overall efficiency level for the degradation of industrial WAS, which was collected from a wastewater treatment plant in an oil refinery factory. Industrial WAS coul be successfully detraded in a batch digestion with ATCC 31197. The stability of the digestion process with ATCC 31197 was successfully verified by semi-continuous (fill-and-draw) digestion experiment. From the results of this study, it was shown that the thermophilic aerobic digestion process with ATCC 31197 could efficiently be applied to the degradation of industrial WAS.

  • PDF

알루미늄의 전기분해를 이용한 오수 중의 인 제거 (Phosphorus Removal from Domestic Sewage by Electrolysis with Aluminium Electrodes)

  • 정경훈;최형일;정오진
    • 한국환경보건학회지
    • /
    • 제25권3호
    • /
    • pp.70-76
    • /
    • 1999
  • A laboratory experiment was performed to investigate the phosphorus removal using the activated sludge-electrolysis reactor which consisted of A$^2$/O system and aluminium electrodes as cathode and anode. In this system, the phosphorus was removed by aluminium ion, which was eluted from aluminiumelectrodes by electrolysis. In the batch experiments, when the current densities were 0.026, 0.052 and 0.08 A/dm$^2$, the phosphorus removal efficiencies for synthetic sewage were 66.4, 86.4 and 98.7% respectively. These results showed that the phosphorus removal efficiency increased with the increase of the current density. When the current values were 13, 26 and 40 mA respectively, the amounts of Al$^{3+}$ eluted from electrodes according to Faraday's law were 0.049, 0.07 and 0.12 g and Al/P mole ratio were 1.1, 2.0 and 3.41. In the continuous experiments, As hydraulic retention time(HRT) increased, COD and total nitrogen(T-N) removal efficiencies for domestic sewage increased. The average phosphorus removal rates of the activated sludge-electrolysis system were 97, 91, 80 and 80% at the HRT of 48, 24, 18 and 12 hours, respectively. Especially, the phosphorus removal rate in the activated sludge system with aluminium electrodes was higher than that in the system without aluminium electrodes.

  • PDF

원생동물을 이용한 하수처리장의 수질 예측 (Protozoa as an Indicator of Activated In Sludge Plant Effluent Quality)

  • 이찬형;문경숙
    • 한국미생물·생명공학회지
    • /
    • 제28권6호
    • /
    • pp.361-366
    • /
    • 2000
  • Genera and number of protozoa were investigated in the conventional activated sludge pilot plant used for the treatment of municipal sewage and pre-treated night soil-containing sewage. In both case, the predominant protozoa was ciliates and among them Vorticella was the most common. In the pilot plant where pre-treated night soil was mixed with municipal sewage, genera of free-swimming ciliates, flagellates and amoeba was higher than in those withour night soil. Correlation analysis on the quality of effluent and protozoa indicates that municipal sewage has positive correlation with protozoa. However in the pilot plan 샐 sewage contatinin pre-treated night coil soil more samples show negative correlation. Followed equations were derived by the regression analysis of BOD in both the pilot plants. In case of pilot plant A of municipal sewage, the analysis B of munici-pal and pre-treated night soil-containing sewage, the analysis of BOD was $6.731$\times$10_{-2}$ $\times$Bodo+0.306(Adjusted $R^2$=0.864). At low temperature, number of protozoa was decreased to 35% and among therm, Aspidisca was the most common genus. Therefore, protozoa can be used as indicator of quality of the effluent in sewage treatment plants.

  • PDF