• Title/Summary/Keyword: Acrylic material

Search Result 340, Processing Time 0.029 seconds

Propylene Hydrogenation over Cubic Pt Nanoparticles Deposited on Alumina

  • Yoo, Jung-Whan;Lee, Sung-Min;Kim, Hyung-Tae;El-Sayed, M.A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.843-846
    • /
    • 2004
  • Pt nanoparticles loaded on alumina through an impregnation at room temperature was prepared using $K_2PtCl_4$ and acrylic acid as capping material. Transmission electron microscopy showed that the deposited Pt particles indicate ca. 80% cubic shapes with a narrow distribution of 8-10 nm in size. Propylene hydrogenation over the catalyst has been carried out to evaluate their catalytic performance by the values of activation energy. It is determined from the initial rate, reaction order, and rate constant and is found to be $9.7{\pm}0.5$ kcal/mol. This value has been discussed by comparing to those of encapsulated- and truncated octahedral Pt nanoparticles deposited on alumina, respectively, to study influence of the particle size and shape, and capping material used on the activation energy.

A Study on the Evaluation Method of Water Leakage Repair in Polyacrylic Resin (폴리 아크릴 레진의 누수 보수 평가에 관한 연구)

  • Cho, Il-Kyu;Kim, Keun-Hur;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.223-224
    • /
    • 2017
  • In this study, various materials such as epoxy material, urethane material, cement material, and acrylic material are used to solve the water leakage occurring in underground structures. However, in the reality that the durability is insufficient and the effect is insufficient, it is aimed to improve the repairing effect by using cement and acrylics in combination. As a first study, we tried to verify the performance of improve the performance by checking the product properties according to the composition ratio of polyacrylic resin. Polyacrylic resin is evaluated in three different composition ratios. When the material is selected for polyacrylic resin, it is applied to the field to understand the maintenance effect and durability.

  • PDF

The Synthesis and Characterization of (TBMA)Macromer Grafted Anionic Acrylic Copolymer ((TBMA)Macromer를 그라프트시킨 음이온성 아크릴 공중합체의 합성과 물성)

  • Kim, Hyoung-Ook;Noh, Si-Tae;Kang, Shin-Chun
    • Applied Chemistry for Engineering
    • /
    • v.4 no.3
    • /
    • pp.627-636
    • /
    • 1993
  • Anionic acrylic resin utilizing macromer(TBMA-g-MMA) copolymer was synthesized by preparing (TBMA) macromer using anionic living polymerization, followed by graft copolymerization with MMA macromer. To control the anionic site content in graft copolymer, the relative composition((TBMA) macromer/MMA ratio) of the graft copolymer was controlled at 7/3, 10/90, 15/85, 20/80, 30/70, 40/60, 50/50 in weight content. In the course of anionic living polymerization of(TBMA) macromer, broad molecular weight distribution (1.4~1.5) was obtained by using n-butyllithium-diphenyethylene initiatior system at $-78^{\circ}C$. To introduce the double bond at the end of chain in termination step, methacryloyl chloride was reacted after insertion of benzaldehyde as capping material. Moreover, TBMA parts in graft copolymer were hydrolyzed in the presence of p-toluenesulfonic acid catalyst, and neutralization of graft copolymer with triethylamine was granted acrylic resin to anionic site. Molecular weight and molecular weight distribution of(TBMA) macromer were determined by GPC, and the hydrolysis of TBMA with neutralization of acrylic resin were determined by IR and NMR. From water dispersion and stability point of view, stable dispersion state appeared at low molecular weight(TBMA) macromer with a small TBMA content as a result of scrutiny about the relation to TBMA content and branch length for(TBMA) macromer molecular weight in graft copolymer.

  • PDF

The stress analysis of supporting tissues according to crown restorative materials in Brånemark osseointegrated implant (Brånemark 골유착성 매식체의 금관 수복재료에 따른 지지조직의 응력분석)

  • Jeong, Gwan-Ho;Bae, Tae Seong;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.199-215
    • /
    • 1990
  • This study was to analyze the stress distribution of implant and supporting tissue in $Br{\aa}nemark$ osseointegration implant. The analysis has been conducted by using the axisymmetric finite element method and type of model according to crown material. Tests have been performed at 1 kg load on central fossa of crown portion. Each type of model was designed differently according to crown material. 1) Porcelain fused to metal crown(Model A) 2) Composite resin veneered crown(Model B) 3) Acrylic resin veneered crown(Model C) 4) Type III gold crown(Model D) The displacements and stresses of implant and supporting structures were analyzed to investigate the influence of the type of crown material. The results were obtained as follows : 1. Displacement of implant was shown uniformly downward displacement in all models and abutments were observed distally downward displacement. 2. In supporting tissues, stress was concentrated on the crest of compact bone and the spongy bone below implant. 3. The PFM and the type III gold crown showed the largest concentration of stress at the crest of compact bone and the spongy bone below implant, respectively. Acrylic resin artificial teeth and composite resin veneered crown indicated almost the same distribution of stress. 4. The gold screw, the abutment screw and the top of abutment showed the concentration of stress in implants of every model.

  • PDF

Characterization of superhydrophilic thin films fabricated by a layer-bylayer self-assembly method (교호흡착법에 의해 제조된 초친수 박막 특성)

  • Kim, Jin-Ho;Hwang, Jong-Hee;Lim, Tae-Young;Jang, Jang-Hoon;Kim, Sae-Hoon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.4
    • /
    • pp.168-172
    • /
    • 2010
  • Superhydrophilic thin film consisted of positively charged poly (allylamine hydrochloride) (PAH) and negatively charged poly (acrylic acid) (PAA) was fabricated by a layer-by-layer (LBL) self-assembly. Glutaraldehyde (GA) was used in order to increase an adhesion hardness by amine-aldehyde reaction. The surface morphology, thickness, transmittance, water contact angle and adhesion hardness of PAH/PAA thin film with or without GA were measured. The adhesion hardness of PAH/PAA thin film with GA deposition increased over 2 times although the film thickness of PAH/GA/PAA decreased than that of PAH/PAA thin film. The increase of adhesion hardness by amine-aldehyde reaction between PAH and GA was measured by fourier transform infrared (FT-IR) spectroscopy. Fabricated PAH/PAA and PAH/GA/PAA thin films showed water contact angel under $5^{\circ}$ and high transmittance over 91.3% at 550 nm.

Wettability of denture relining materials under water storage over time

  • Jin, Na-Young;Lee, Ho-Rim;Lee, Hee-Su;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 2009
  • STATEMENT OF PROBLEM. Poor wettability of denture relining materials may lead to retention problems and patient discomfort. PURPOSE. Purpose of this study is to compare and evaluate wettability of nine denture relining materials using contact angle measurements under air and water storage over time. MATERIAL AND METHODS. Nine denture relining materials were investigated in this study. Two heat-curing polymethyl-methacrylate(PMMA) denture base materials: Vertex RS, Lang, one self-curing polyethyl-methacrylate(PEMA) chairside reline resin: Rebase II, six silicone relining materials: Mucopren soft, Mucosoft, $Mollosil^{{R}}$ plus, Sofreliner Touch, GC $Reline^{TM}$ Ultrasoft, Silagum automix comfort were used in this experiment. Contact angles were measured using high-resolution drop shape analysis system(DSA 10-MK2, KRUESS, Germany) under three conditions(in air after setting, 1 hour water storage, and 24 hours water storage). Nine materials were classified into three groups according to material composition(Group 1: PMMA, Group 2: PEMA, Group 3: Silicone). Mean values of contact angles were compared using independent samples t-test and one-way ANOVA, followed by a Scheffe's post hoc analysis($\alpha$=0.01). RESULTS. Contact angles of materials tested after air and water storage increased in the following order: Group 1(PMMA), Group 2(PEMA), Group 3(Silicone). Heat-cured acrylic denture base resins had more wettability than silicone relining materials. Lang had the highest wettability after 24 hours of water storage. Silicone relining materials had lower wettability due to their hydrophobicity. Wettability of all denture relining materials, except Rebase II and $Mollosil^{{R}}$ plus, increased after 24 hours of water storage. CONCLUSIONS. Conventional heat-cured resin showed the highest wettability, therefore, it can be suggested that heat-cured acrylic resin is material of choice for denture relining materials.

A Study on the Crack Response and Waterproof Properties of High-Functional Water-Based Acrylic Paints for Exterior Walls (고기능성 외벽용 수성 아크릴계 도료의 균열 대응성 및 방수 특성 평가 연구)

  • Kim, Yong-Ro;Ko, Hyo-Jin;Park, Jin-Sang;Kim, Dong-Bum;Lee, Sang-Wook
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.593-604
    • /
    • 2021
  • In this study, a comparative test was conducted on a specially developed elastic waterproof paint and general water-based paint for the purpose of responding to cracks occurring on the outer wall of concrete structures and improving watertightness. Through the comparative experiment, it was confirmed that the watertightness could be improved by securing the crack shielding property, and it was also confirmed that about 10 times more crack responsiveness was secured compared to general water-based paint. In addition, it was confirmed that the adhesion performance of at least 1.3MPa and resistance to a water permeation pressure of 0.1MPa were possible, confirming that stability was secured from a waterproofing perspective.

IN VITRO STUDY OF TOOTH TEMPERATURE CHANGE DURING POLYMERIZATION REACT10N OF THE COLD-CURED RESINS USED IN PROVISIONAL CROWN AND FIXED PARTIAL DENTURES (자가 중합 임시수복용 레진의 경화 시 외부환경 변화에 따른 치아의 온도변화)

  • Oh, Wu-Sik;Baik, Jin;Kim, Hyung-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.503-513
    • /
    • 2006
  • Statement of the problem: The cold-cured resins used in fabrication of the provisional crown and fixed partial dentures could cause pulpal damage by heat generated during exothermic polymerization reactions. Purpose: In this in vitro study investigates the how external conditions such as material of the matrix, thickness of the matrix and thickness of dentin affect the temperature of the tooth during polymerization reaction of the cold-cured resins. Material and methods : To measure the temperature of the resin, metal die was maintained to the temperature of $37^{\circ}C$ with water bath to simulate the temperature of thetooth and thermocouple was placed in the center of the metal die. Acrylic pipe was cut in height of 1, 2, 3, 6, 10 mm and placed on the metal die and mixed resin was pored in the acrylic pipe As the resin polymerized temperature was recorded with the thermometer. Temperature of the resin using matrix was recorded by using the individual tray relieved in different thickness 2, 5, 7, 10 mm. The material of the matrix was irreversible hydrocolloid impression material, vinyl polysilloxane impression material and vacuum-formed template Temperature rise of the resin using different thickness of tooth section was record ed by placing tooth section on the metal die and placing resin over the tooth section. Results : Conclusion : 1. Temperature rise increased as the thickness of the resin increased but there was no significant differences over 3 mm thickness of the resin. 2. The lowest temperature rise was showed in irreversible hydrocolloid impression material and vinyl polysilloxane impression material vacuum-formed template as in orders. 3, Temperature rise of the resin decreased regardless of the thickness of the matrix when vinyl polysilloxane impression material was used as the matrix. 4 When irreversible hydrocolloid impression material was used as matrix, the temperature rise of the resin decreased as the thickness of the matrix increased and there was no temperature rise when thickness of the matrix reached 10 mm, 5. The temperature rise of the resin did not decreased when Polypropylene vacuum-formed template was used as the matrix. 6, The temperature of the resin increased as the thickness of the dentin decreased.

The Realization of Intensity-modulated Radiation Therapy Using the Liquid Shielding Material (액체 차폐물을 이용한 강도변조방사선치료의 구현)

  • 오영기;김진기;신교철;김기환;윤상모;김재철;박인규
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • We developed a new method that the radiation field shape and intensity could be controlled automatically with a insertion of the liquid shielding material box having a rotatable model imitated the 3-dimensional target volume within. The molded box filled with the mercury was mounted to the tray. A acrylic model imitated the 3-dimensional target volume was fixed into the center of the interior of the box. Although the gentry rotate, the acrylic model can be returned to the original direction of the target due to the action of the gravity. The film measurements at the gantry rotation angle 0$^{\circ}$, 45$^{\circ}$, and 90$^{\circ}$, respectively were shown that the radiation intensities were modulated properly and the field shapes were conformed to the target. We verified the dose distribution for our method with a cylindrical acrylic phantom inserted a film within. In the case of the 8-field irradiation, the 80% isodose line was enclosed the target shape properly. This results show the realization of a new intensity-modulated radiation therapy(IMRT).

  • PDF

Properties of Eco-friendly Acrylic Resin/Clay Nanocomposites Prepared by Non-aqueous Dispersion (NAD) Polymerization (비수계 분산중합으로 제조된 환경친화성 아크릴수지/나노클레이 복합재료의 특성 연구)

  • Kim, Yeongho;Lee, Minho;Jeon, Hyeonyeol;Lee, Young Chul;Min, Byong Hun;Kim, Jeong Ho
    • Korean Chemical Engineering Research
    • /
    • v.54 no.1
    • /
    • pp.120-126
    • /
    • 2016
  • Eco-friendly acrylic resin/clay nanocomposites containing pristine montmorillonite (PM) or modified clays (30B and 25A) were prepared from acrylic and styrenic monomers using non-aqueous dispersion (NAD) polymerization. Effect of nanoclays on physical properties of polymerization product and resulting nanocomposites was investigated. In view of NAD particle stability, addition of nanoclay at the beginning of polymerization is proved to be good. Results of gel fraction, acid value and viscosity of the NAD product showed that nanocomposites containing clay 25A showed better physical properties than the ones with other clays. GPC results exhibit the increase in molecular weight and decrease in polydispersity index for the 25A nanocomposite. Increase in layer distance confirmed from XRD analysis showed good dispersion of 25A in the nanocomposite. Thermal and dynamic mechanical analysis showed that highest glass transition temperature and storage modulus for 25A nanocomposites. These results indicate that 25A nanoclay gives the best properties in the process of non-aqueous dispersion polymerization of acrylic resin/nanoclay nanocomposites.