PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교 (Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images)

  • 김영재;박훈희;이주영;소영;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.

메타버스 투자 추진이 기업 가치에 미치는 영향 분석: 이벤트 연구 방법론 (How Market Reacts on the Metaverse Initiatives? An Event Study)

  • 백민아;김정하;이동원
    • 경영정보학연구
    • /
    • 제25권4호
    • /
    • pp.183-204
    • /
    • 2023
  • 전 세계적으로 유행한 COVID-19로 인해 비대면 행사가 많이 개최되며, 2021년도에 메타버스가 많은 관심을 받게 되었다. 많은 회사들이 메타버스에 대한 투자를 발표하고 주식 시장에도 큰 변화를 일으킴으로써 메타버스의 가치에 대한 연구의 중요성이 커지고 있다. 본 논문은 이러한 사회 현상을 기반으로 메타버스 투자 계획과 주가 사이의 관계를 분석한다. 2019년부터 2021년까지 수집된 Lexis-Nexis 뉴스 데이터를 토대로 이벤트 연구방법론(event study method)을 사용하여 이러한 관계를 실증적으로 검토하였으며, 세부적인 요인들을 설정하여 선형회귀분석을 실시하였다. 결과적으로, 메타버스 관련 계획은 기업 가치에 긍정적인 영향을 미친다는 결과를 확인할 수 있었다. 기술적인 측면에서는 메타버스 가능 기술(예: NFT, VR 기기, 디지털 트윈)과 공통 기술(예: 반도체, 인공지능, 클라우드) 두 변수 모두 시장 수익률에 긍정적인 영향을 미치는 것으로 나타났으며, 특히 가상 환경의 중요성이 강조되었다. 또한 전략적 관점에서 급진적 혁신(예: 피보팅, 기업 인수)은 점진적 혁신(예: 파트너십, 기술 투자)보다 시장 수익에 더 긍정적인 영향을 미치는 것으로 나타났다. 마지막으로 메타버스 산업은 서비스 산업군에 속하지 않은 회사(예: 전자 장치, 기계 장치)에서 더 긍정적일 수 있다는 결과를 보였다. 학술적으로 메타버스의 혁신적 가치와 중요 요인에 대해 실증적으로 규명하였다는 점에서 연구의 의의가 있다.

Total Bilirubin Level as a Predictor of Suboptimal Image Quality of the Hepatobiliary Phase of Gadoxetic Acid-Enhanced MRI in Patients with Extrahepatic Bile Duct Cancer

  • Jeong Ah Hwang;Ji Hye Min;Seong Hyun Kim;Seo-Youn Choi;Ji Eun Lee;Ji Yoon Moon
    • Korean Journal of Radiology
    • /
    • 제23권4호
    • /
    • pp.389-401
    • /
    • 2022
  • Objective: This study aimed to determine a factor for predicting suboptimal image quality of the hepatobiliary phase (HBP) of gadoxetic acid-enhanced MRI in patients with extrahepatic bile duct (EHD) cancer before MRI examination. Materials and Methods: We retrospectively evaluated 259 patients (mean age ± standard deviation: 68.0 ± 8.3 years; 162 male and 97 female) with EHD cancer who underwent gadoxetic acid-enhanced MRI between 2011 and 2017. Patients were divided into a primary analysis set (n = 184) and a validation set (n = 75) based on the diagnosis date of January 2014. Two reviewers assigned the functional liver imaging score (FLIS) to reflect the HBP image quality. The FLIS consists of the sum of three HBP features, each scored on a 0-2 scale: liver parenchymal enhancement, biliary excretion, and signal intensity of the portal vein. Patients were classified into low-FLIS (0-3) or high-FLIS (4-6) groups. Multivariable analysis was performed to determine a predictor of low FLIS using serum biochemical and imaging parameters of cholestasis severity. The optimal cutoff value for predicting low FLIS was obtained using receiver operating characteristic analysis, and validation was performed. Results: Of the 259 patients, 140 (54.0%) and 119 (46.0%) were classified into the low-FLIS and high-FLIS groups, respectively. In the primary analysis set, total bilirubin was an independent factor associated with low FLIS (adjusted odds ratio per 1-mg/dL increase, 1.62; 95% confidence interval [CI], 1.32-1.98). The optimal cutoff value of total bilirubin for predicting low FLIS was 2.1 mg/dL with a sensitivity of 95.1% (95% CI: 88.9-98.4) and a specificity of 89.0% (95% CI: 80.2-94.9). In the validation set, the total bilirubin cutoff showed a sensitivity of 92.1% (95% CI: 78.6-98.3) and a specificity of 83.8% (95% CI: 68.0-93.8). Conclusion: Serum total bilirubin before acquisition of gadoxetic acid-enhanced MRI may help predict suboptimal HBP image quality in patients with EHD cancer.

PLS 경로모형을 이용한 IT 조직의 BSC 성공요인간의 인과관계 분석 (A PLS Path Modeling Approach on the Cause-and-Effect Relationships among BSC Critical Success Factors for IT Organizations)

  • 이정훈;신택수;임종호
    • Asia pacific journal of information systems
    • /
    • 제17권4호
    • /
    • pp.207-228
    • /
    • 2007
  • Measuring Information Technology(IT) organizations' activities have been limited to mainly measure financial indicators for a long time. However, according to the multifarious functions of Information System, a number of researches have been done for the new trends on measurement methodologies that come with financial measurement as well as new measurement methods. Especially, the researches on IT Balanced Scorecard(BSC), concept from BSC measuring IT activities have been done as well in recent years. BSC provides more advantages than only integration of non-financial measures in a performance measurement system. The core of BSC rests on the cause-and-effect relationships between measures to allow prediction of value chain performance measures to allow prediction of value chain performance measures, communication, and realization of the corporate strategy and incentive controlled actions. More recently, BSC proponents have focused on the need to tie measures together into a causal chain of performance, and to test the validity of these hypothesized effects to guide the development of strategy. Kaplan and Norton[2001] argue that one of the primary benefits of the balanced scorecard is its use in gauging the success of strategy. Norreklit[2000] insist that the cause-and-effect chain is central to the balanced scorecard. The cause-and-effect chain is also central to the IT BSC. However, prior researches on relationship between information system and enterprise strategies as well as connection between various IT performance measurement indicators are not so much studied. Ittner et al.[2003] report that 77% of all surveyed companies with an implemented BSC place no or only little interest on soundly modeled cause-and-effect relationships despite of the importance of cause-and-effect chains as an integral part of BSC. This shortcoming can be explained with one theoretical and one practical reason[Blumenberg and Hinz, 2006]. From a theoretical point of view, causalities within the BSC method and their application are only vaguely described by Kaplan and Norton. From a practical consideration, modeling corporate causalities is a complex task due to tedious data acquisition and following reliability maintenance. However, cause-and effect relationships are an essential part of BSCs because they differentiate performance measurement systems like BSCs from simple key performance indicator(KPI) lists. KPI lists present an ad-hoc collection of measures to managers but do not allow for a comprehensive view on corporate performance. Instead, performance measurement system like BSCs tries to model the relationships of the underlying value chain in cause-and-effect relationships. Therefore, to overcome the deficiencies of causal modeling in IT BSC, sound and robust causal modeling approaches are required in theory as well as in practice for offering a solution. The propose of this study is to suggest critical success factors(CSFs) and KPIs for measuring performance for IT organizations and empirically validate the casual relationships between those CSFs. For this purpose, we define four perspectives of BSC for IT organizations according to Van Grembergen's study[2000] as follows. The Future Orientation perspective represents the human and technology resources needed by IT to deliver its services. The Operational Excellence perspective represents the IT processes employed to develop and deliver the applications. The User Orientation perspective represents the user evaluation of IT. The Business Contribution perspective captures the business value of the IT investments. Each of these perspectives has to be translated into corresponding metrics and measures that assess the current situations. This study suggests 12 CSFs for IT BSC based on the previous IT BSC's studies and COBIT 4.1. These CSFs consist of 51 KPIs. We defines the cause-and-effect relationships among BSC CSFs for IT Organizations as follows. The Future Orientation perspective will have positive effects on the Operational Excellence perspective. Then the Operational Excellence perspective will have positive effects on the User Orientation perspective. Finally, the User Orientation perspective will have positive effects on the Business Contribution perspective. This research tests the validity of these hypothesized casual effects and the sub-hypothesized causal relationships. For the purpose, we used the Partial Least Squares approach to Structural Equation Modeling(or PLS Path Modeling) for analyzing multiple IT BSC CSFs. The PLS path modeling has special abilities that make it more appropriate than other techniques, such as multiple regression and LISREL, when analyzing small sample sizes. Recently the use of PLS path modeling has been gaining interests and use among IS researchers in recent years because of its ability to model latent constructs under conditions of nonormality and with small to medium sample sizes(Chin et al., 2003). The empirical results of our study using PLS path modeling show that the casual effects in IT BSC significantly exist partially in our hypotheses.

3T Multi Voxel Spectroscopy에서 SENSE와 NEX 변화에 따른 정상인 뇌 대사물질 변화 분석 (Alteration Analysis of Normal Human Brain Metabolites with Variation of SENSE and NEX in 3T Multi Voxel Spectroscopy)

  • 성열훈;임재동;이재현;조성봉;우동철;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.256-262
    • /
    • 2008
  • 자기공명분광법(magnetic resonance spectroscopy: MRS)은 인체내 대사물질을 정량분석하여 병변의 조기진단 및 정밀진단에 도움을 주고 있으며, 최근 임상에 이용되고 있는 자기공명분광법은 single voxel spectroscopy (SVS) 기법과 multi voxel spectroscopy (MVS) 기법이 있다. 본 연구에서는 SENSE와 NEX를 변화시킨 multi voxel spectroscopy (MVS)의 데이터와 기존 single voxel spectroscopy (SVS)의 데이터를 비교 분석하여, 각각의 데이터의 유의성 차이를 평가하고자 하였다. 정상 성인 지원자 13명(남자: 5명, 여자: 8명, 평균 41세, 표준편차 11.65세)을 대상으로 chemical shift image (CSI)를 이용한 MVS검사를 시행하였다. 장비는 3.0T Achieva Release Version 2.1 (Philips Medical System, Netherland)을 이용하였고, 8 channel head coil을 사용하여 brain thalamus 부위에서 CSI spectrum을 1 slice 획득하였다. Scan parameter로는 FOV (field of view): $230{\times}184mm^2$, TR (time to repetition): 2000 msec, TE (time to echo): 288 msec, matrix: $15{\times}12$, VOI(view of interest): $110{\times}110mm^2$, voxel size: $15{\times}15{\times}15mm^3$로 하였다. SENSE factor (S)와 NEX (N)는 S1*N1, S2*N1, S2*N2, S3*N2로 변화하여 스펙트럼을 획득하였고, 각 scan time은 5분 54초, 3분 32초, 6분 20초, 4분 20초였다. 얻은 모든 MRS 데이터는 jMRUI 3.0 Version 프로그램에서 분석하였고, SENSE factor와 NEX를 변화시켜 얻은 MVS data 그룹들이 정상 성인 뇌 대사물질의 변화에 영향을 주는지 검증하기 위해 그룹 간에 ANOVA분석을 실행하여 P 값이 0.05보다 크게 나오면 그룹들 사이에 유의한 차이가 없다고 분석하였다. NAA/Cr과 Cho/Cr의 상대적 비율은 MV와 SVS사이에서는 유의한 차이가 없었다. 즉, SENSE factor와 NEX를 변화시켜 얻은 MVS data에서 정상 성인 뇌조직의 대사물질의 변화를 관찰한 결과, S1*N1의 NAA/Cr은 $1.45{\pm}0.03$, Cho/Cr은 $0.88{\pm}0.03$이고, S2*N1의 NAA/Cr은 $1.44{\pm}0.03$, Cho/Cr은 $0.87{\pm}0.05$, S2*N2의 NAA/Cr은 $1.43{\pm}0.02$, Cho/Cr은 $0.87{\pm}0.04$이며, S3*N2의 NAA/Cr은 $1.45{\pm}0.03$, Cho/Cr은 $0.87{\pm}0.03$으로 나타났다(F-value : 1.37, D.F : 3, P-value : 0.262). 그러나 데이터의 질을 측정하기 위한 MVS 데이터의 NAA Peak line-width는 SVS 데이터의 NAA Peak line-width 보다 약 3배 정도 넓었다. 본 연구에서는 MVS에서 SENSE factor와 NEX 값을 다양하게 변화시킨 MVS의 데이터와 SVS의 데이터가 큰 차이가 없음을 확인하였다. 즉, 어는 특정 부위의 뇌 조직의 대사물질은 MVS와 SVS 기법 모두 큰 차이가 없음을 확인할 수 있었다. 그러므로 MVS는 SVS보다 광범한 부위를 짧은 시간 안에 검사할 수 있으므로 매우 유용한 방법이라고 사료된다.

  • PDF

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.122-125
    • /
    • 2004
  • 폐, 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range 3 cm${\sim}$3 m), Computer(RS232C), Servo Motor (Torque 2.3 Kg)등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램 하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터 간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터 간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}$1% 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 2.34 ${\times}$ 10-4 초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정 간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정 간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}$1%이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34 ${\times}$ 10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.

  • PDF

PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가 (The Effectiveness Evaluation of Reconstruction Method Using DFOV Position Changes for Reduction of Artifact Around Hotspot in PET/CT Images)

  • 한동찬;홍건철;최춘기;이혁;최성욱
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.90-94
    • /
    • 2013
  • PET/CT 영상에서 인공물은 정량성을 저하시키는 원인이 된다. 여러 인공물 중 방사성의약품 주사 시 주사오류로 인해 발생할 수 있는 열소는 그 주변부에 인공물을 발생시켜 영상의 질을 저하시킬 뿐 아니라 정량평가의 정확도를 저하시킨다. 본 연구에서는 영상의 재구성시 표시시야(Display Field of View, DFOV)의 중심이동법을 이용하여 주사부위에 발생한 열소부위를 제거하고 정량평가에 미치는 영향을 평가해 보고자 한다. GE Discovery STE 16 (GE Healthcare, Milwaukee, USA) 장비에 1994 NEMA 모형을 이용하였다. 모형에 0.005 MBq/mL의 $^{18}F-FDG$를 채우고 모형주변에 열소대 배후방사능의 농도비가 200:1이 되도록 열소를 만들어 모형외곽에 인위적으로 두었다. 영상획득 후 DFOV의 중심 위치를 이동하여 열소부위가 DFOV로부터 벗어나도록 영상을 재구성한 후 적용 전, 후를 비교하였다. 영상에 대한 평가는 열소의 영향을 받지 않은 부위에서 DFOV 중심이동 전, 후의 배후방사능의 평균 표준섭취계수와 표준편차를 산출하여 재구성에 의한 영향을 비교, 평가하였다. 또한 인공물이 발생한 부위에 관심영역을 설정하고 인공물의 발생 전, 후의 평균 표준섭취계수와 표준편차를 산출하여 백분율 오차를 각각 비교하였다. 모형영상 내 열소로 인한 인공물의 영향을 받지 않은 부위에서 DFOV 중심이동 법을 적용하기 전 평균 표준 섭취계수는 $0.67{\pm}0.06g/mL$이었고, 적용 후에는 $0.65{\pm}0.06g/mL$로 나타났다. 또한 영상에서 열소에 의해 발생한 인공물이 있는 부위의 평균 표준섭취계수와 표준편차는 $0.32{\pm}0.08g/mL$였으며, DFOV 중심이동을 적용한 경우는 $0.56{\pm}0.12g/mL$로 나타났다. 이 때 열소의 영향을 받은 열소 인접부위와 상대적으로 영향을 받지 않은 부위에 대한 백분율 오차는 65.3%와 97.4%로 각각 나타났다. PET/CT 영상에서 열소에 의해 발생 된 인공물은 DFOV의 중심이동법 적용 시 평균 표준섭취계수를 32.1% 향상시킬 수 있으며, 이 때 중심이동 법에 의한 다른 부위의 영향은 유의한 차이가 없음을 알 수 있다. 결과에서와 같이 방사성의약품의 주사오류 시 발생한 종 창 등으로 발생되는 인공물의 영향은 DFOV 중심이동법을 적용할 경우 보다 정확한 정량평가가 가능해지고 그로 인하여 영상의 진단적 가치를 높일 수 있을 것이다.

  • PDF

Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교 (Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T)

  • 김성길;이규수;임채평
    • 한국방사선학회논문지
    • /
    • 제5권6호
    • /
    • pp.401-407
    • /
    • 2011
  • TE를 변화시킨 정상인 대뇌의 MR spectrum에서 주요 대사물질의 면적과 SNR을 측정하여 PRESS 펄스파형과 STEAM 펄스파형 그리고 1.5T와 3.0T간의 자장세기에 따른 spectrum 간의 차이를 알아보고자 하였다. Phantom 실험을 통하여 적절한 TR을 정한 후, 정상인 지원자 10명(3.0T 5명, 1.5T 5명 ; 남 22~30세 : 평균 26세)을 대상으로 단일용적기법의 STEAM과 PRESS 기법을 시행하였다. 사용된 장비는 3.0T MR scanner(Magnetom Trio, SIEMENS, Germany)와 1.5T MR scanner(Signa Twinspeed GE, USA)이였다. 영상변수는 TR은 2000ms, TE는 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA는 96, 용적 크기는 $20{\times}20{\times}20mm3$로 하였으며, spectrum 획득시간은 3분 20초였다. 획득한 데이터는 후처리과정을 통하여 PRESS와 STEAM, 그리고 1.5T와 3.0T system 간의 NAA, Cho, Cr 등의 단순면적값과 SNR을 비교하였다. 또한 육안적 관찰을 통하여 각 대사물질들의 관찰정도를 비교하였다. 1.5T와 3.0T MR spectrum을 분석한 결과, STEAM과 PRESS의 주요 대사물질의 단순 면적값과 SNR은 TE가 증가함에 따라 감소하는 경향을 보였으며, PRESS는 STEAM보다 1.5T에서 1.4배, 3.0T에서 1.3배 높은 SNR을 보였다. 자장의 세기에 따른 SNR 비교에서는 TE가 30ms에서 3.0T가 1.5T보다 약 2배 정도 높은 SNR을 보였으나 TE값이 증가함에 따라 3.0T에서의 SNR 감소율이 1.5T에서의 SNR 감소율보다 커서 TE가 90ms 이상부터는 큰 차이가 없었다. 반면 3.0T의 spectrum에서는 1.5T에서 구분할 수 없었던 ${\alpha}$-Glx, ${\beta}{\cdot}{\gamma}$-Glx, NAA complex등 작은 대사물질들을 보다 정확히 감별 할 수 있었고 short TE의 PRESS일 때 short TE의 STEAM보다 작은 대사물질들이 잘 관찰 되었다. 3.0T spectrum의 해상도와 SNR이 1.5T spectrum에 비하여 우수함을 알 수 있었다. 그러나 90ms이상의 long TE에서는 3.0T와 1.5T spectrum간의 SNR은 차이가 없었다. 따라서 고자장하에서의 자기공명분광법은 30ms 이하의 짧은 TE를 이용한 PRESS 펄스 파형을 사용하는 것이 임상적으로 유용하게 사용될 수 있을 것이라 사료된다.

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • Radiation Oncology Journal
    • /
    • 제22권4호
    • /
    • pp.316-324
    • /
    • 2004
  • 목적 : 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사 체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 대상 및 방법 : 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range $3\~3$ m), Computer (RS232C), Sewo Motor (Torque 2.3 Kg) 등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 결과 : 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}1\%$ 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 $2.34{times}10^{-4}$초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 결론 : 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}1\%$ 이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34H10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.

Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가 (The Evaluation of Dynamic Continuous Mode in Brain SPECT)

  • 박선명;김수영;최성욱
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.15-22
    • /
    • 2017
  • 본원에서 시행하는 Brain SPECT 검사는 $^{99m}Tc-ECD$ 또는 $^{99m}Tc-HMPAO$를 주사 한 후 뇌 영상을 얻어 뇌 관류상태를 평가하는 검사이다. 하지만 검사 중 일부 환자 상태가 불안정할 경우 움직임이 발생하여 재촬영이나 검사실패로 이어지는 경우가 발생 된다. 이에 현재의 Step and Shoot Mode(SSM)이 아닌 움직임이 발생되더라도 재구성을 통해 영상 구현이 가능한 Dynamic Continuous Mode(DCM)를 적용하여 환자의 재촬영과 피폭선량을 감소시키고 검사실에 운영 효율성을 높이고자함에 있다. Deluxe PET/SPECT Phantom과 Hoffman 3D Brain Phantom으로 Filtered Back Projection(FBJ)과 Iterated Reconstruction(IR)으로 재구성하여 영상을 구현하였다. 이미지를 가지고 핵의학과 5년이상의 임상경력이 있는 의사 5명과 방사선사 5명을 대상으로 리커트 5점 척도(Likert 5 Scale)와 블라인드 판독 테스트를 실시 하였다. 판독의 블라인드 테스트 결과 최소 DCM 3Repeat (30%)에서 7Repeat (50%)까지 판독에 영향을 주지 않는다고 답해 주었다. DCM으로 검사 시 환자 움직임이 발생되면 불필요한 부분을 제거하여 재촬영, 재주사의 감소를 가져올 수 있고, 장비 오류 시 영상을 재구성 후 구현 할 수 있어 검사실 운영 효율도 높을 수 있을 것으로 기대된다. 또한 SPECT검사뿐 만 아니라 SPECT/CT검사 에서도 활발한 연구가 적용 될 거라 기대 되며 마지막으로 실제 환자 적용은 환자 데이터의 충분한 수집 후 병원 판독 실정에 맞게 도입이 필요 하리라 사료된다.

  • PDF