• Title/Summary/Keyword: Acoustic transducer

Search Result 391, Processing Time 0.026 seconds

Scanning Acoustic Microsope System Using 200MHZ ZnO Transducer (ZnO를 이용한 초음파 현미경의 제작과 평가)

  • Jang, Ji-Won;Do, Si-Hong;Lee, Jong-Gyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.4
    • /
    • pp.200-208
    • /
    • 1989
  • To the purpose of preparation for investigating aspect of material that not revealed by the light microscope and extending our knowledge in applicable field, a scanning acoustic microscope system of 200MHz was organized and appraised its performance with experiments. Professor N.CHUBACHI in Tohoku University in Sendai, Japan provided the ZnO transducer with lens. The system for transmitting and receiving ultrasonic pulses of 200nsec was organized with a rectangular audio wave generator for modulation of 200MHz carrier wave, gating system for transmitting and receiving, mixer for converting intermediate frequency, a directional coupler, ZnO transducer, radio frequency amplifiers. detecter and personal computer. The Scanning system was driven in micro steps with three stepping motors in the direction of x, y and z axes. The system was a reflecting type scanning acoustic microscope and the operation program processed graphics data from receiving echo intensities. Photograph of fish scale obtained by optical microscope was compared with its image by the scanning acoustic microscope organized here. The result was satisfiable.

  • PDF

Development of Ultrasonic Sensor to Measure the Distance in Underwater (수중 거리 측정을 위한 초음파 센서의 개발)

  • Kim, Chi-Hyo;Kim, Tae-Sung;Jung, Jun-Ha;Lee, Jin-Hyung;Lee, Min-Ki;Jang, In-Sung;Shin, Chang-Joo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.293-298
    • /
    • 2013
  • This research develops an ultrasonic sensor to measure the distance in underwater. The ultrasonic transducer transmits an acoustic signal to an object and receives the echo signal reflected from the object. The ultrasonic driver calculates a distance by multiplying the acoustic speed to the time of flight(TOF) which is the time necessary for the acoustic signal to travel from the transducer to the object. We apply a thresholding and a cross correlation methods to detect the TOF and show their results. When an echo pulse is corrupted with noise and its shape is distorted, the cross correlation method is used to find the TOF based on the maximum similarity between the reference and the delayed echo signals. The echoes used for the reference signal are achieved at the different environments, which improves the performance of the sensor. This paper describes the driver of the acoustic sensor and analyzes the performance of sensors in different measurement environments.

  • PDF

Acoustic field simulation of a PZT4 disc projector using a coupled FE-BE method

  • Jarng, S.S.
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.211-218
    • /
    • 1999
  • This paper describes the application of a coupled finite element-boundary element method (FE-BEM) to obtain the steady-state response of a piezoelectric transducer. The particular structure considered is a PZT4 disc-typed projector. The projector is three-dimensionally simulated to transduce applied electric charge on axial surfaces of the piezoelectric disc to acoustic pressure in air or in water. The directivity pattern of the acoustic field formed from the projected sound pressure is also simulated. And the displacement of the disc caused by the externally applied electric charge is shown in temporal motion. The coupled FE-BE method is described in detail.

  • PDF

Behavior of ultrasonic transducer in air by using finite element method simulation (FEM 시뮬레이션을 이용한 공기 중에서의 초음파 트랜스듀서의 거동)

  • Chae, Yeon-Hwa;Choi, Kyoon;Lee, Ho-Yong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.28 no.5
    • /
    • pp.185-190
    • /
    • 2018
  • The Tonpilz transducer was implemented using the structural module of COMSOL which is a FEM simulation tool. In order to compare the sound pressure characteristics of the transducer with the simulated results, the spacial distribution of the sound pressure level (SPL) was simulated by the acoustic module of COMSOL and then compared with the SPL distribution measured by a microphone. As a result, the resonance frequency and the peak in SPL for the simulation were predicted to be 28 kHz and 163.5 dB, respectively. And the resonance frequency and the peak in SPL for the actual transducer were measured to be 28.84 kHz and 137.8 dB, respectively. It is also confirmed that the simulated SPL distribution and the actually measured one are formed in a similar pattern.

Application of Ultrasonic Wave to the Squeezing Process From the Seeds (식물 씨앗의 착유과정에 있어서 초음파의 적용)

  • Kim, Jung-Soon;Lee, Hui-Uk;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.2
    • /
    • pp.91-96
    • /
    • 2010
  • To improve the limit of efficiency of squeezing oil in a conventional method, which seeds are compressed simply, the adoptability of the additional energy by the ultrasonic wave was investigated experimentally. As the results, using the ultrasonic vibration from the Langevin-type transducer, the efficiency was increased up to 25 %, whereas the conventional method has 15% efficiency. To investigate the additional pressure by the ultrasonic wave, the acoustic impedance of the sample and the vibration velocity of the transducer were measured. Although the amplitude of the ultrasonic is about 2.8 % of the compression pressure, the efficiency is increased a lot as mentioned above because the pressure is changed according to ultrasonic period.

Development of a Spherically Focused Capacitive-film Air-coupled Ultrasonic Transducer

  • Song, Jun-Ho;Chimenti Dale E.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.6
    • /
    • pp.446-450
    • /
    • 2005
  • We have built a spherically focused, not using acoustic mirrors, capacitive micromachined air-coupled ultrasonic transducer. A flexible backplate of a copper/polyimide backplate is used, permitting it to conform to a spherically shaped substrate. The backplate is patterned with $40-{\mu}m$ depressions having $80-{\mu}m$ center-to-center spacing. A $6-{\mu}m$ thick aluminized Mylar film completing the transducer is deformed to allow it to conform to the spherical backplate. The device's frequency spectrum is centered at 805kHz with -6dB points at 440 and 1210kHz.

Optimal Transducer Positions of an Active Noise Control System with an Opening in an Enclosure (개구부를 가지는 실내의 능동소음제어시스템의 최적 트랜스듀서 위치)

  • 백광현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.157-163
    • /
    • 2004
  • Optimal transducer positions are important as much as the control algorithms and hardware performance in the active noise control system. This study is similar to the past researches on the optimal transducer locations but with a far field noise source having a plane wave characteristic and the noise coming through an opening such as a window in an enclosure. Optimization techniques are used to find sets of optimal loudspeaker positions from a larger possible loudspeaker positions. Loudspeakers are placed on the surface of opening at the wall and inside of the enclosure. Using the measured acoustic transfer impedances and numerical simulations with the optimization technique, optimal positions are identified and compared. When a small number of loudspeakers are used. loudspeaker positions on the opening near the center seems to be the best place, but when a larger number of loudspeakers are used it was difficult to find simple patterns in the optimal positions. With the optimally positioned loudspeakers, optimal microphone positions are also studied.

Pulse-echo Response of Piezoceramic-Polymer 1-3 Type Composite Transducer for a Level Limit Switch Applications (Level Limit스위치용 1-3형 복합압전체 트랜스듀서의 펄스-에코응답특성)

  • Choi, H.I.;Sohn, M.H.;Kim, H.K.;Park, K.I.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.224-228
    • /
    • 2002
  • In this study, the piezoelectric ceramics PZT powder was synthesized by the Wet-Dry combination method. Flexible 1-3 type composite specimens were fabricated with the piezoceramics PZT filler phase and Eccogel polymer matrix phase. This paper represents the pulse-echo response of the 1-3 type composite transducer to check it out to investigate a basic property regarding a level limit switch. The acoustic impedance of 1-3 type composite was improved than that of single phase PZT ceramics. The pulse-echo response of transducer fabricated with the self-made 1-3 type composites resonator was better than that of the solid PZT transducer.

  • PDF

Analysis and verification of the characteristic of a compact free-flooded ring transducer made of single crystals (압전단결정을 이용한 소형 free-flooded ring 트랜스듀서의 성능 특성 예측 및 검증)

  • Im, Jongbeom;Yoon, Hongwoo;Kwon, Byungjin;Kim, Kyungseop;Lee, Jeongmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.278-286
    • /
    • 2022
  • In this study, a 33-mode Free-Flooded Ring (FFR) transducer was designed to apply piezoelectric single crystal PIN-PMN-PT, which has high piezoelectric constants and electromechanical coupling coefficient. To ensure low-frequency high transmitting sensitivity characteristics with a small size of FFR transducer, the commercial FFR transducer based on piezoelectric ceramics was compared. To develop the FFR transducer with broadband characteristics, a piezoelectric segmented ring structure inserted with inactive elements was applied. The oil-filled structure was applied to minimize the change of acoustic characteristics of the ring transducer. It was verified that the transmitting voltage response, underwater impedance, and beam pattern matched the finite element numerical simulation results well through an acoustic test. The difference in the transmitting voltage response between the measured and the simulated results is about 1.3 dB in cavity mode and about 0.3 dB in radial mode. The fabricated FFR transducer had a higher transmitting voltage response compared to the commercial transducer, but the diameter was reduced by about 17 %. From this study, it was confirmed that the feasibility of a single crystal-applied FFR transducer with compact size and high-power characteristics. The effectiveness of the performance prediction by simulation was also confirmed.

An Introduction to the Underwater Survey Operations using a Side Scan Sonar System (천해역 해저탐사 및 영상분석 기법 소개)

  • 주영석;우종식
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.156-159
    • /
    • 2001
  • Recently, side scan sonar system has been developed and operated to survey cable laying, sunken bodies, geometry of sea bottom and so on. It uses the acoustic signals, which are emitted from two transducer arrays, left and right sides, to get geometric information of the specified area. This system consists of transceiver board, towed body, deck unit and GPS receiver. The transceiver board, nested in a watertight canister, controls the transmitting and receiving of the acoustic pulses from transducer arrays. After receiving the scattered signals, it processes BP(Band Pass) filtering, AGC(Automatic Gain Control), TVG(Time Varying Gain) and Heterodyne. The deck init has the signal processing part, A/D converter, power supplier, and real-time monitoring part. The towed body has been designed to satisfy the optimal hydrodynamic behavior during towing, In this paper, brief introductions on the design theory of transceiving part and some results from the field which have been operated recently will be introduced.

  • PDF