• Title/Summary/Keyword: Acoustic source

Search Result 935, Processing Time 0.03 seconds

Daily change and acoustical characteristics of underwater noise on a submerged sea tunnel in Jinhae Bay, Korea (진해만 침매터널 상부의 수중소음의 일변화 및 음향적 특성)

  • SHIN, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.3
    • /
    • pp.461-473
    • /
    • 2015
  • Jinhae Bay located in the southern of Korean Peninsular is an important spawning area in Korea. By some preliminary studies it was measured several times that adult Pacific codes (Gadus microcephalus) were passed (swimming layer: 15 to 18 m) over a submerged sea tunnel (sea bottom: about 30 m) rather than another immigration route when the Pacific codes were tagged surgically with an acoustic transmitters and released inside of the Bay. There is a possibility that the Pacific codes and the other fishes use the route on the sea tunnel as an immigration route are affected by a human-generated underwater noise around the sea tunnel due to the sea tunnel traffic. On this study the 25-hour measurements of the underwater noise level by water layer were conducted with a hydrophone attached on a portable CTD and an underwater noise level meter during four seasons, and the acoustical characteristics of the underwater noise was analyzed. The mean traffic volume for one hour at the sea tunnel on the spring was shown the largest value of 1,408 [standard deviation (SD): 855] vehicles among four seasons measurement. The next one was ordered on the autumn [1,145 (SD: 764)], winter [947 (SD: 598)] and summer [931 (SD: 558)] vehicles. Small size vehicle was formed 84.3% of the traffic volume, and ultra-small size, medium size, large size and extra-large size of the vehicle were taken possession of 8.7%, 3.2%, 2.0% and 1.8%, respectively. On the daily change of the noise level in vertical during four seasons the noise level of 5 m-layer was shown the highest value of 121.2 (SD: 3.6) dB (re $1{\mu}Pa$), the next one was 10 m-layer [120.7 (SD: 3.5)], 2 m- and 15 m-layer [120.3 (SD: 3.5 to 3.7)] and 1 m-layer [119.2 (SD: 3.6)] dB (re $1{\mu}Pa$). In relation with the seasonal change of the noise level the average noise level measured during autumn was shown the highest value of 123.9 (SD: 2.6) dB (re $1{\mu}Pa$), the next was during summer [121.4 (SD: 3.2)], spring [118.0 (SD: 3.4)] and winter [116.5 (SD: 5.1)] dB (re $1{\mu}Pa$). In results of eigenray computation when the real bathymetry data (complicate shape of sea bed) was applied the average number of eigenray was 2.68 times (eigenrays: 11.03 rays) higher than those of model bathymetry (flat and slightly sloped sea bottom). When the real bathymetric data toward inside (water depth becomes shallow according to a distance between the source of noise and hydrophone) of the Bay was applied on the eigenrays calculation the number of the eigenray was 1.31 times (eigenrays: 12.49 rays) larger than the real bathymetric data toward outside (water depth becomes deep with respect to the distance). But when the model bathymetric data toward inside of the Bay was applied the number of the eigenray was 1.05 times (eigenrays: 4.21 rays) larger than the model bathymetric data toward outside.

Seismic reflection survey in a tidal flat: A case study for the Mineopo area (갯벌 지역에서의 탄성파 탐사: 민어포 조간대 지역의 사례)

  • Jou Hyeong-Tae;Kim Han-Joon;Lee Gwang-Hoon;Choi Dong-Lim;Kim Min-Ji;Cho Hyun-Moo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.67-84
    • /
    • 2002
  • A shallow high-resolution seismic reflection survey was carried out at the Mineopo tidal flat on the western coast of Korea. The purpose of the survey was to investigate shallow sedimentary structure of the tidal (fat associated with the recent sea level change. A total of 795 shots were generated at 1 m interval from a 5-kg hammer source and recorded on 48 channels of 100 Hz geophones along two mutually perpendicular profiles. The water-saturated ground condition resulted in suppressed ground rolls by significantly decreasing rigidity. In addition, seismic velocities over 1500 m/s provided easy segregation of reflected arrivals from lower velocity noise. As a consequence, seismic sections were created that are high in resolution and signal to noise ratio as well. The stack sections show that the tidal flat consists of 5 sedimentary sequences above acoustic basement. Although deposition is largely characterized by the transgressive sedimentary facies resulting from sea level rise, erosional surfaces are well-resolved within the sequences.

  • PDF

Transmission Noise Seduction Performance of Smart Panels using Piezoelectric Shunt Damping (압전감쇠를 이용한 압전지능패널의 전달 소음저감 성능)

  • 이중근
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.1
    • /
    • pp.49-57
    • /
    • 2002
  • The possibility of a transmission noise reduction of piezoelectric smart panels using piezoelectric shunt damping is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing materials are bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to reduce the sound transmission at low panel resonances, piezoelectric damping using the measured electrical impedance model is adopted. Resonant shunt circuit for piezoelectric shunt damping is composed of register and inductor in series, and they are determined by maximizing the dissipated energy throughout the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a tube with square crosses section and a loud-speaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across panels is measured. Noise reduction performance of a smart panels possessing absorbing material and/or air gap shows a good result at mid frequency region but little effect in the resonance frequency. By enabling the piezoelectric shunt damping, noise reduction of 10dB, 8dB is achieved at the resonance frequencise as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.

  • PDF

A study on the Frequency Analysis Function of the Auricle Using A Notch Filter

  • Park, Dong-Cheol
    • International journal of advanced smart convergence
    • /
    • v.10 no.4
    • /
    • pp.241-255
    • /
    • 2021
  • The human auricle is the first part to receive sound from the outside. In this part, the frequency range of human recognizable form is divided and organized. In this study, we propose modeling by applying a single sound source to the surface of the human auricle. This means that when the sound pressure of a low frequency (low frequency) sound enters the pinna, the impedance felt at the tip of a part of the non-linear surface of the pinna is mainly due to the tensile force at the end of the part of the non-linear surface of the pinna. By expressing the situation of moving at a very small speed, the characteristic impedance of the pinna was confirmed to be negative infinity, and it was also confirmed that the speed at the tip of a part of the non-linear surface of the pinna was 0 in the anti-resonance state. It was found that the wave propagation phenomenon that determines the characteristics of the filter is determined by how large the wavelength, kL, is compared to the length of the tip of a part of the non-straight surface of the pinna. Humans first receive sounds from outside through their ears. The auricle is non-linear and has a curved shape, and it is known that it analyzes frequencies while receiving external sounds. The human ear has an audible frequency range of 20Hz - 20,000Hz. Through the study, we applied the characteristics of the notch filter to hypothesize that the human audible frequency range is separated from the auricle, and applied filter theory to analyze it, and as a result, meaningful results were obtained. The curved part and the inner part of the auricle function as a trumpet, collecting sounds, and at the same time amplifying the weak sound of a specific band. The point was found and the shape of the envelope detected in the auricle was found. Selectivity for selecting sounds coming from the outside is the formula of the pinna that implements the function of Q. The function of distinguishing human-recognizable sound from the pinna from low to high through frequency analysis is performed in the pinna, and the 2-3kHz area, where human hearing threshold is the most sensitive, is also the acoustic impedance of the most recessed area of the pinna. It can be seen that starting from.

Effect of Noise in Human Body (소음이 인체에 미치는 영향)

  • 이영노
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.7-8
    • /
    • 1972
  • The effects of noise exposure are of two types: Nonauditory effects and auditory effects. Nonauditory effects of noise exposure are interference with communication by speech, sleeping and emotional behavior. The noise will cause the high blood pressure and rapid pulse, also that decrease the salivation and gastric juice. in experimentaly showed that the Corticoid hormon: Gonatotropic hormone were decrease and Thyrotropic hormoone is increase. Auditory effect of noise exposure. when the normal ear is exposed to noise at noise at hamful intensities (above 90㏈) for sufficiently long periods of time, a temoral depression of hearing results, disappearing after minutes or hours of rest. When the exposure longer or intesity greater is reached the Permanent threshold shift called noise-induced hearing loss. Hearing loss resulting from noise exposure presents legal as well as medical problems. The otologist who examines and evaluates the industrial hearing loss cases must be properly informed, not only concerning the otologic but also about the physical and legal aspects of the problems. The measurement of hearing ability is the most important part of a hearing conservation, both preplacement and periodic follow-up tests of hearing. The ideal hearing conservation program would be able to reduce or eliminate the hazardous noise at its source or by acoustic isolation of noisy working area and two ear protections (plugs and muff type) were developed for personal protection.

  • PDF