A vibration based acoustic wave propagation technique for assessment of crack and corrosion induced damage in concrete structures
-
- Structural Engineering and Mechanics
- /
- 제78권5호
- /
- pp.599-610
- /
- 2021
Early detection of small concrete crack or reinforcement corrosion is necessary for Structural Health Monitoring (SHM). Global vibration based methods are advantageous over local methods because of simple equipment installation and cost efficiency. Among vibration based techniques, FRF based methods are preferred over modal based methods. In this study, a new coupled method using frequency response function (FRF) and proper orthogonal modes (POM) is proposed by using the dynamic characteristic of a damaged beam. For the numerical simulation, wave finite element (WFE), coupled with traditional finite element (FE) method is used for effectively incorporating the damage related information and faster computation. As reported in literature, hybrid combination of wave function based wave finite element method and shape function based finite element method can addresses the mid frequency modelling difficulty as it utilises the advantages of both the methods. It also reduces the dynamic matrix dimension. The algorithms are implemented on a three-dimensional reinforced concrete beam. Damage is modelled and studied for two scenarios, i.e., crack in concrete and rebar corrosion. Single and multiple damage locations with different damage length are also considered. The proposed methodology is found to be very sensitive to both single- and multiple- damage while being computationally efficient at the same time. It is observed that the detection of damage due to corrosion is more challenging than that of concrete crack. The similarity index obtained from the damage parameters shows that it can be a very effective indicator for appropriately indicating initiation of damage in concrete structure in the form of spread corrosion or invisible crack.
최근 유량 측정을 위해 사용되는 ADCP를 통해 부가적으로 측정되는 초음파산란도 자료를 활용하여 부유사농도를 측정하는 연구가 수행되고 있다. 이에 국내에서는 국가하천에 설치되어 있는 자동유량관측소의 초음파산란도를 활용하여 연속적인 부유사농도를 측정하는 연구가 수행되고 있다. 이를 통해 10분 단위로 연속적인 유사량 자료를 생산할 수 있을 것으로 기대되며, 현재 유사량 측정결과의 제공을 위해 사용되는 유량-유사량 관계곡선의 산포로 인한 신뢰도 문제를 개선할 수 있을 것으로 기대되고 있다. 그러나, 이미 설치된 자동유량관측소의 H-ADCP 원시데이터를 활용하여 다지점에서 부유사농도를 측정에 대한 분석을 수행하기 위해서는 초음파산란도의 보정, 관계식 개발, 관계식 적용을 통한 유사량 측정 결과의 분석을 위한 소프트웨어 개발이 필요하다. 이에 본 연구에서는 초음파산란도 자료를 이용하여 부유사농도를 분석할 수 있는 소프트웨어 개발하고자 하였다. 개발된 소프트웨어는 Microsoft Visual Studio를 이용하여 C# 언어를 사용하여 개발하였으며, ComponentOne 라이브러리를 활용하여 그래픽 사용자 인터페이스(GUI)를 구현하였다. 소프트웨어의 구성은 H-ADCP 원시자료와 실측 부유사농도 자료와의 시간동기화를 통해 동일시간에서 측정된 자료를 획득, 초음파산란도의 보정과 지표로 활용할 초음파산란도의 측정영역 분석, 초음파산란도-부유사농도와의 다중 회귀를 통한 관계식 개발 및 통계 분석결과 도출, 관계식을 활용한 부유사농도 계산을 수행할 수 있도록 구성하였다. 본 연구를 통해 개발된 소프트웨어를 통해 추후에 시범적용 예정인 자동유량관측소의 초음파산란도를 활용 부유사농도 측정 방법에 대한 분석 효율성을 향상시키고, 지속적인 개선을 통해서 실제 실무에서 활용이 가능할 것으로 기대된다.
Underwater wireless communication is a challenging issue for realizing the smart aqua-farm and various marine activities for exploring the ocean and environmental monitoring. In comparison to acoustic and radio frequency technologies, the visible light communication is the most promising method to transmit data with a higher speed in complex underwater environments. To send data at a speedier rate, high-performance photodetectors are essentially required to receive blue and/or cyan-blue light that are transmitted from the light sources in a light-fidelity (Li-Fi) system. Here, we fabricated high-performance organic phototransistors (OPTs) based on P-type donor polymer (PTO2) and N-type acceptor small molecule (IT-4F) blend semiconductors. Bulk-heterojunction (BHJ) PTO2:IT-4F photo-active layer has a broad absorption spectrum in the range of 450~550 nm wavelength. Solution-processed OPTs showed a high photo-responsivity >1,000 mA/W, a large photo-sensitivity >103, a fast response time, and reproducible light-On/Off switching characteristics even under a weak incident light. BHJ organic semiconductors absorbed photons and generated excitons, and efficiently dissociated to electron and hole carriers at the donor-acceptor interface. Printed and flexible OPTs can be widely used as Li-Fi receivers and image sensors for underwater communication and underwater internet of things (UIoTs).
수중음향측정 방식은 어류이동에 대한 연속적인 자료를 확보하기 위해 사용되는 방식으로, 대형하천이나 하구에서 이동하는 어류의 이동에 용이하게 활용된다. 낙동강은 남한에서 가장 긴 하천으로 연속적인 보의 설치로 인하여 하천의 변형이 이루어지고 있다. 본 연구에서는 국내에 서식하는 잉어과 어류인 강준치를 대상으로 하여 수중음향측정방식을 적용, 서식처범위(home range)와 이동거리, 이동패턴에 대한 모니터링을 시행하였다. 연구는 낙동강 하구둑부터 창녕함안보까지의 약 80 km 구간을 대상으로 총 14개체의 강준치를 3지점에 방류하여 모니터링을 수행하였다. 하구둑(N02)에서 방류한 8개체들은 방류지점으로부터 15.9 km 상류지점까지를 서식처 범위로 하여 이동하였고, 삼랑진(N07)에서 방류한 4개체들은 신호가 사라진 E12개체를 제외하고 하류로 이동하였으며, 9.7 km 구간을 서식처 범위로 활용하였다. 2개체가 방류된 창녕함안보(N10)에는 모두가 하류로 이동 하였으며, 이 중 E14개체는 32일 동안 가장 긴 누적감지거리(36.7 km)를 이동하였다. 강준치의 체장과 누적감지거리, 서식처 범위와는 상관성이 없는 것으로 확인되었다(Spearman rank correlation, p>0.05). 비록 본 연구 방식이 담수어류의 이동에 유용하지만 좀 더 자세한 결과를 확보하기 위해서는 수신기의 수와 적용하는 발신기의 수를 증가시킬 필요성이 있다.
이 연구의 목적은 원하는 지점까지 자동으로 이동하고 정확한 수심에서 채수 하고 수질을 측정할 수 있는 무인장비를 개발하는데 있다. 이를 위해 채수 리프트 및 채수 컨테이너를 제작하고, VRS-GPS, 음향측심기, 및 수질 측정기를 장착한 무인 탐사체를 제작하였으며, 자동운항 알고리즘 및 프로그램, 자동 채수 프로그램, 수질분포도 작성 프로그램을 개발하였다. 유수지에서 실험한 결과 무인 탐사체는 오차범위 3m 내에서 약 93%의 정확도로 계획 경로를 따라 운항하였다. 또한 채수 리프트에 장착한 수질측정 센서로 대상지역의 수질을 실시간으로 획득하고 무선 인터넷을 통하여 서버에 전송하여 각 지점의 수질을 실시간으로 모니터링 할 수 있었다. 육상에서의 실험을 통해 채수 리프트는 약 94%의 정확도로 원하는 길이를 조절할 수 있었다. 무인 탐사체를 활용하여 자동화된 수질측정 방법은 접근이 어려운 지역에서의 수질측정이 가능하고, 작업자의 안전을 확보할 수 있을 것으로 판단된다.
There are two types of phonetic study, acoustic and physiologic, for differentiating the three manner categories of Korean stop consonants. On the physiologic studies, there are endoscopic, electromyographic(EMG), electroglottographic(EGG) and aerodynamic studies. In this study, I tried to investigate general features of Korean stops using EGG study for the open quotient of vocal fold and baseline shift during speech, and aerodynamic characteristics for e subglottal air pressure, air flow and glottal resistance at consonants. On the aerodynamic study, the glottalized and aspirated stops may be characterized by e increasing subglottal pressure comparing with lenis stop at consonants. The airflow is largest in the aspirated stops followed by lenis stops and glottalized. The glottal airway resistance (GAR) showed highest in the glottalized followed by the lenis, but lowest in e aspirated during e production of consonants, and showed highest in e aspirated, but low in the glottalized and lenis during the production of vowel. The glottal resistance at consonant showed significant difference among consonants and significant interaction between subject and types of consonant. The glottal resistance at vowel showed significant difference among consonants, and e interaction occured between subject and types of consonant. The electroglottography(EGG) has been used for investigating e functioning of e vocal folds during its vibration. The EGG should be related to the patterns of the vocal fold vibration during phonation in characterizing the temporal patterns of each vibratory cycle. The purpose of this study is to investigate the dynamic change of EGG waveforms during continuous speech. The dynamic changes of EGG waveforms fir the three-way distinction of Korean stops were characterized that the aspirated stop appears to be characterized by largest open quotient and smallest glottal contact area of the vocal folds in e initial portion of vocal fold vibration ; the lenis stop by moderate open quotient and glottal contact area ; but the glottalized stop by smallest open quotient and largest glottal contact area. There may be close relationship between the OQ(open quotient) in the initial voice onset and the glottal width at the time of consonant production, the larger glottal width just before vocal fold vibration results in the smaller OQ of the vocal fold vibration in the initial voice onset. The EGG changes of baseline shift during continuous speech production were characterized by the different patterns for the three types of Korean consonants. The small and less stiffness change of baseline shift was found for the lenis and the glottalized, and the largest and stiffest change was found for the aspirated. On the baseline shift for the initial voice onset, they showed so similar patterns with for the consonant production, larger changed in the aspirated. for the lenis and the glottalized during the initial voice onset, three subjects showed individual difference each other. I suggest at s characteristics were strongly related with articulatory activity of vocal tract for the production of consonant, especially for the aspirated stop. The suspecting factors to affect EGG waveforms are glottal width, vertical laryngeal movement and the intrapharyngeal pressure to neighboring tissue during connected spech. So the EGG may be an useful method to describe laryngeal activity to classify pulsing conditions of the larynx during speech production, and EGG research can be controls for monitoring the vocal tract articulation, although above factors to affect EGG would have played such a potentially role on vocal fold vibratory behavior obtained using consonant production.
본 연구에서는 임계하균열성장 변수를 구하기 위해 제안된 Wilkins의 시험법을 압열인장시험과 결합하여 화강암의 인장강도, Mode I 파괴인성과 임계하균열성장지수를 동시에 구하였으며 이를 사용하여 암석의 장기거동을 평가하였다. 또한 내부압력을 받는 압축공기저장(CAES) 공동에 대한 장기안정성을 수치해석코드인 FRACOD를 사용하여 해석하였다. 시험 결과 화강암의 임계하균열성장지수(n)는 29.39로 결정되었으며 5 ~ 6 MPa의 내압은 저장공동의 장기안정성에 큰 영향을 미치지 않는 것으로 나타났다. 또한 시험 과정에서 측정한 미소파괴음을 분석한 결과 암석내의 미소균열 생성 및 전파에 따른 암석의 손상을 정량적으로 기술할 수 있었다. 만약, 실내와 동일한 조건으로 현장에서 AE 모니터링을 수행할 경우 AE 모니터링을 통해서 하중을 받는 암석의 현재 상태를 정량적으로 평가하는 것이 가능할 것으로 판단된다.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70