Propagation Behavior and Structural Variation of C3H8-Air Premixed Flame with Frequency Change in Ultrasonic Standing Wave (정상초음파의 주파수 변화에 따른 C3H8-Air 예혼합화염의 전파거동 및 구조변이)

  • Lee, Sang Shin;Seo, Hang Seok;Kim, Jeong Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.173-181
    • /
    • 2014
  • The propagation behavior and structural variation of a premixed propane/air flame with frequency change in an ultrasonic standing wave at various equivalence ratios were experimentally investigated using Schlieren photography and pressure measurement. The propagating flame was observed in high-speed Schlieren images, allowing local flame velocities of the moving front to be analyzed in detail. The study reveals that the distorted flame front and horizontal splitting in the burnt zone are due to the ultrasonic standing wave. Vertical locations of the distortion and horizontal stripes are intimately dependent on the frequency of the ultrasonic standing wave. In addition, the propagation velocity of the flame front bounded by the standing wave is greater than that of the flame front without acoustic excitation. As expected, the influence of the ultrasonic standing wave on premixed-flame propagation becomes more prominent as the frequency increases.

Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality (Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로)

  • Park, Ik-Gun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.112-121
    • /
    • 1994
  • This paper discusses the feasibility of ultrasonic C-scan technique for nondestructive evaluation of spot weld quality. Ultrasonic evaluation for spot weld quality was performed by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget, preliminary infinitesimal gap experiment by newton ring is tried in order to set up the optimum ultrasonic test condition. Ultrasonic image data obtained were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be measured with the accuracy of 1.0mm, and voids included in nugget can be detected to $10{\mu}m$ extent with simplicity and accuracy. Finally, it was found that it is necessary to make a profound study of definite discrimination of corona bond from nugget and the approach of quantitative evaluation of nugget diameter by utilizing the various image processing techniques.

  • PDF

Development of Fracture Toughness Evaluation Method for Composite Materials by Non-Destructive Testing Method (비파괴검사법을 이용한 복합재료의 파괴인성 평가법 개발)

  • Lee, Y.T.;Kim, K.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.4
    • /
    • pp.278-291
    • /
    • 1998
  • Fracture process of continuous fiber reinforced composites is very complex because various fracture mechanisms such as matrix cracking, debonding, delamination and fiber breaking occur simultaneously during crack growth. If fibers cause crack bridging during crack growth, the stable crack growth and unstable crack growth appear repeatedly. Therefore, it is very difficult to exactly determine tile starting point of crack growth and the fracture toughness at the critical crack length in composites. In this research, fracture toughness test for CFRP was accomplished by using acoustic emission(AE) and recording of tile fracture process in real time by video-microscope. The starting point of crack growth, pop-in point and the point of unstable crack growth can be exactly determined. Each fracture mechanism can be classified by analyzing the fracture process through AE and video-microscope. The more reliable method ior the fracture toughness measurement of composite materials was proposed by using the combination of R-curve method, AE and video microscope.

  • PDF

Telemetering of the Underwater Noise (수중소음의 원격측정)

  • Sin, Hyeon-Ok;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.1
    • /
    • pp.11-17
    • /
    • 1987
  • This paper describes an availability of the teltmeter device made as a trial to measure the under-water noise, and the results of the test. This telemeter device adopts FM-FM system, and its main carrier wave is 146.2MHz. The trans-mission power is about 1w, and the available distance of transmission is 2.5KM. The timer built in the telemeter device controls transmission time and pause time automatically by the R-C time-constant. The former is 30-32 seconds and the latter is 10-12 seconds. The underwater noise in the set net fishing ground and at the breeding tank was measured, and recorded simultaneously on land and at sea with the telemeter device. When the input voltages of the transmitter is 100-300mV, the value of telemetering ambient noise and bio-acoustic underwater noise well agreed with that of the direct measurement. And the teleme-tered underwater noise decreases in proportion the distance between the transmitter and receiver.

  • PDF

Verification Study on Real-time Automated Discharge Measurement (실시간 자동측정유량의 검증 연구)

  • Roh, Young-Sin;Kim, Dae-Young;Park, Hyun-Geun;Jung, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.329-333
    • /
    • 2008
  • 본 연구에서는 도플러 방식 초음파유속계(ADVM, Acoustic Doppler Velocity Meter) 및 이동시간차방식 초음파유속계(UVM, Ultrasonic Velocity Meter)의 유량자료 검증을 위해 두 가지 방식이 적용된 한강대교와 여주대교의 2007년 운영성과를 검토하고 측정된 결과분석을 통해 자동유량측정시설의 유량측정자료를 검증하였다. 측정된 유량의 검증을 위해 평 저수시 유속계 측정 및 이동 ADCP법에 의한 연속 유량측정결과와 비교하였으며, 또한 봉부자를 이용한 측정결과와의 비교를 통해 홍수시 측정결과를 검토하였다. 또한 댐방류량, 하수처리장 방류량, 각종 취수량을 이용한 물수지 분석을 통해 자동유량측정에 의해 산정된 유출량과 비교하였다. ADVM 방식이 적용된 한강대교의 조위영향에 따른 수위변화를 고려하여 한 주기에 대한 측정을 수행하여 이를 비교한 결과, 흐름이 정체되는 일부구간의 측정결과를 제외하면 대부분 상대오차가 10% 내외가 발생하는 것으로 나타났다. 또한 월별 물수지 분석을 수행한 결과, 설치초기 시스템 안정화작업으로 인해 결측이 많이 발생한 $3{\sim}4$월을 제외하면 10%내외의 오차가 발생하였으며, 홍수기인 $6{\sim}7$월 사이에는 $1.9{\sim}5.5%$의 상대오차를 보여 자동유량측정시설의 측정결과가 매우 양호한 것으로 나타났다. 여주대교의 UVM 방식의 경우 측정장비의 안정화가 이루어진 5월부터 9월까지의 측정결과는 수위유량관계곡선으로 산정된 유량과 비교하였을 때 10%내외의 상대오차를 보인 것으로 나타났다. 아울러 월별 물수지 분석결과에서도 결측이 많이 발생한 5월의 23.7%의 오차를 제외하면, $5{\sim}10%$내의 오차를 보인 것으로 나타났으며 홍수기인 $6{\sim}8$월의 경우 5%이내의 오차가 발생한 것으로 나타났다.

  • PDF

Bistatic Scattering from a Hemi-Spherically Capped Cylinder

  • Park, Sang-Hyun;La, Hyoung-Sul;Cho, Sung-Ho;Oh, Taek-Hwan;Kim, Young-Shin;Lee, Chang-Won;Na, Jung-Yul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.3E
    • /
    • pp.115-122
    • /
    • 2006
  • The bistatic scattering of an incident wave by a hemi-spherically capped cylinder is of particular interest because it has rarely been studied until the present day. The configuration of a hemi-spherically capped cylinder is similar to naval underwater weapons (submarines, mines, torpedos, etc.), but which is not exactly the same. This paper describes a novel laboratory experiment aimed at direct measurement of bistatic scattering by a hemi-spherically capped cylinder. Bistatic scattering by a hemi-spherically capped cylinder was measured in an acoustic water tank (5m long, 5m wide, 5m deep) using a high frequency projector (120kHz) and hydrophone. Measurements of monostatic scattering were also made under the same conditions. The bistatic scattering pattern by a hemi-spherically capped cylinder was measured against the incident angles $(0^{\circ},\;15^{\circ},\;20^{\circ},\;30^{\circ},\;45^{\circ},\;60^{\circ},\;90^{\circ})$ in order to verify various scattering pattern characteristics by the change of incident angle. The results indicate that the bistatic scattering TS at a wide scattering angle is much stronger than the mono static scattering TS. In bistatic scattering, the forward scattering TS is significantly stronger than the backward scattering TS, and the forward scattering pattern is also broader. In case of seven incident angles, the maximum value of forward scattering TS is about 14dB stronger than that of backward scattering TS. It is also found that forward scattering varies with the incident angle of sound to a much less extent than backscattering, and it is not seriously affected by the incident angle. These features could be the advantages of using forward scattering for detecting underwater targets at long range and increasing detection area and probability.

Study on Supersonic Jet Noise Reduction Using a Mesh Screen (메쉬 스크린을 이용한 초음속 제트소음 저감법에 관한 실험적 연구)

  • Kweon, Yong-Hun;Lim, Chae-Min;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.377-381
    • /
    • 2006
  • This paper describes experimental work to control supersonic jet noise using a mesh screen that is placed at the nozzle exit plane. The mesh screen is a wire-gauze screen that is made of long stainless wires with a very small diameter. The nozzle pressure ratio is varied to obtain the supersonic jets which are operated in a wide range of over-expanded to moderately under-expanded jets. In order to perturb mainly the initial jet shear layer, the hole is perforated in the central part of the mesh screen. The hole size is varied to investigate the noise control effectiveness of the mesh screen. A schlieren optical system is used to visualize the flow fields of supersonic jet with and without the mesh screen device. Acoustic measurement is performed to obtain the OASPL and noise spectra. The results obtained show that the present mesh screen device leads to a substantial suppression of jet screech tones. The hole size is an important factor in reducing the supersonic jet noise. For over-expanded jets, the noise control effectiveness of the mesh screen appears more significant, compared to correctly and under-expanded jets

  • PDF

Validation of Assessment for Mean Flow Field Using Spatial Averaging of Instantaneous ADCP Velocity Measurements (ADCP 자료의 공간평균을 이용한 평균유속장 산정에 대한 검증)

  • Kim, Dong-Su;Kang, Boo-Sik
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.107-118
    • /
    • 2011
  • While the assessment of mean flow field is very important to characterize the hydrodynamic aspect of the flow regime in river, the conventional methodologies have required very time-consuming efforts and cost to obtain the mean flow field. The paper provides an efficient technique to quickly assess mean flow field by developing and applying spatial averaging method utilizing repeatedly surveyed acoustic Doppler current profiler(ADCP)'s cross-sectional measurements. ADCP has been widely used in measuring the detailed velocity and discharge in the last two decades. In order to validate the proposed spatial averaging method, the averaged velocity filed using the spatial averaging was compared with the bench-mark data computed by the time-averaging of the consistent fix-point ADCP measurement, which has been known as a valid but a bit inefficient way to obtain mean velocity field. The comparison showed a good agreement between two methods, which indicates that the spatial averaging method is able to be used as a surrogate way to assess the mean flow field. Bed shear stress distribution, which is a derived hydrodynamic quantity from the mean velocity field, was additionally computed by using both spatial and time-averaging methods, and they were compared each other so as to validate the spatial averaging method. This comparison also gave a good agreement. Therefore, such comparisons proved the validity of the spatial averaging to quickly assess mean flow field. The mean velocity field and its derived riverine quantities can be actively used for characterizing the flow dynamics as well as potentially applicable for validating numerical simulations.

Coherent Analysis of vehicle HVAC Using the MDSA Method (다차원 해석법을 이용한 자동차 공조시스템의 기여도분석)

  • Oh Jae-Eung;Hwang DongKun;Abu Aminudin;Lee Jung-Youn;Kim SungSoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.143-150
    • /
    • 2005
  • To verify applicability of multi-dimensional spectral analysis (MDSA) fur noise source identification two different approaches which are frequency response and coherent function have been investigated. The coherence function approach appears able to separate the correlated system when the noise sources were coherent. In this study, we identify contribution of structure-borne-noise of vehicle HVAC system using MDSA method. Firstly, to identify the applicability of MDSA method, 4-inputs of vehicle HVAC system were the signals measured by accelerometers attached on the selected noise sources which were composed of blower, evaporator, heater and duct. While 1-output which was driver's position sound was the SPL signals measured by a remote microphone, when the blower motor was operating. We identify efficiency of systems modeled with four Inputs/single output through ordinary coherence function (OCF) and partial coherence function (PCF). As a result of experiment, the blower accounted for $62-88\%$ of the overall level of sound energy density. Also, according to the analysis of acoustic signal and vibration signals measurement, an investigation of the noise source identification in the vehicle HVAC is presented. With the sound intensity method, the major sources of the vehicle HVAC radiation are verified. Also the method of improving the noise reduction is proposed by attaching damping patch access to blower motor and noise reduction is verified.

Review on Monitoring Volume Transport through Measurement of Submarine Cable Voltages around Korea (한반도 주변의 해저 케이블 전압측정을 통한 해수수송량 관측)

  • Kim, Yun-Bae;Kim, Young-Ho;Lyu, Sang-Jin;Kim, Kuh;Choi, Byeong-Ho
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.2
    • /
    • pp.73-81
    • /
    • 2004
  • Voltage induced by the Tsushima Current on an abandoned submarine telephone cable has been measured since March 1998 in order to monitor the volume transport through the Korea Strait. Voltage has a good linear relationship with the transport measured by bottom-mounted Acoustic Doppler Current Profilers (ADCPs) along a section spanning the Korea Strait. This paper reviews researches using submarine cables briefly; we introduce the method to measure voltage on submarine cables, present some results focusing on the example of the Korea Strait, and mention the future prospect to use other submarine cables around Korea.