• 제목/요약/키워드: Acoustic Measurement

검색결과 900건 처리시간 0.026초

수중청음기 배열의 간격 및 깊이 변화에 따른 측정 소음준위 오차 (Sound Source Level Error on Element Spacing and Depth of Hydrophone Array)

  • 윤종락
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1997년도 영남지회 학술발표회 논문집 Acoustic Society of Korean Youngnam Chapter Symposium Proceedings
    • /
    • pp.68-74
    • /
    • 1997
  • Ship radiated noise is an infortant parameter which dtermines Anti Submarine Warfare(ASW) countermeansure or passive Sonar detection and classification performance. Its measurement should be performed under controlled ocean acoustic environment. In data reduction of the measured data from hydrophone array, theeffect fo ambient noise, surface reflection and bottom reflection etc. should be compensated to obtain the source level of the ship radiated noise. This study describes the measurement hydrophone array design criteria based on the analysis of transimission anomaly due to the surface reflection.

  • PDF

SAW를 이용한 CaAs 및 $Al_{0-3}Ga_{0-7}As$ 에너지 갭 측정 (Energy gap measurement of GaAs and $Al_{0-3}Ga_{0-7}As$ using SAW)

  • 박남천;이건일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.389-392
    • /
    • 1987
  • The energy gaps of undoped and Cr doped GaAs and $Al_{0-3}Ga_{0-7}As$ was measured nondestructively using surface acoustic wave (SAW) technique. The result is good agreement with other reported result. This technique is inexpensive and simple one for the measurement of mole fraction of $Al_xGa_{1-x}As$.

  • PDF

건축음향을 위한 MLS 측정방법 (MLS for Building Acoustics Measurement)

  • Borjabad, Roberto
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.386-393
    • /
    • 1996
  • The paper describes how a Maximum Length Sequence(MLS) and correlation technique in the form of Hadamard transformation may be applied for the measurement of airborne sound reduction. It is shown that in most cases, the values obtained by the MLS technique will be equal to the expected values obtained by the classical method. However, due to the correlation process involved, the MLS method will be much less sensitive to disturbances from extraneous noise. The described method has been implemented in an RTA acoustic analyser.

  • PDF

사무공간의 음향성능 측정, 평가 방법의 표준화와 유럽 국가들의 음향성능 기준 비교 (Comparison of acoustics performance measurement and evaluation standard of office space and office acoustics criteria of European countries)

  • 정정호
    • 한국음향학회지
    • /
    • 제42권2호
    • /
    • pp.133-142
    • /
    • 2023
  • 업무 형태 변화와 Information Technology(IT) 기술 발전 그리고 Coronavirus disease(COVID)-19 상황 등에 따라 사무환경도 변화되고 있다. 사무공간 사용자가 쾌적하고 효율적으로 업무를 수행하기 위해서는 구성원 사이의 교류는 물론 개인의 프라이버시 확보가 필요하다. 우리나라도 사무공간의 음향성능 개선에 대한 요구가 증가하고 있으나, 관련 성능 기준과 지침은 수립되어 있지 않은 실정이다. 본 연구에서는 사무공간 음향성능 측정, 평가 방법의 표준화와 유럽 국가들의 음향성능 기준을 비교, 검토하였다. 국제표준화 동향과 각국의 음향성능 기준을 종합적으로 검토하고 우리나라 사무공간 음향 실태 조사 등을 통해 사무공간 음향성능과 만족도 평가 기준을 수립하여 활용하는 것을 제안한다. 국제표준화 방향과 통신, 전기음향 시스템과의 호환 등을 고려하여 음성전달지수 또는 음성전달지수 응용지표를 활용한 기준을 수립하는 것이 적절하고 활용도와 호환성이 높을 것으로 판단된다. 또한, 사무용 가구류 업계에서도 사무공간의 음향성능 개선에 관심을 나타내고 있어, 사무용 가구류의 음성 레벨 저감량에 관한 성능 기준을 수립하고 표시하는 방안을 마련하는 것이 필요하다.

자기탄성체 리본의 공진을 이용한 인-라인 오일 점도센서 (In-line Oil Viscosity Sensor Implementing An Elastomagnetic Ribbon Resonance)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제26권2호
    • /
    • pp.97-104
    • /
    • 2010
  • A new magnetoelastic technique of oil viscosity measurement, where the oil viscosity is estimated by frequency shift of natural oscillations of magnetoelastic ribbon, is implemented in this study. Laboratory tests of the detector prototype are performed for measurement of viscosity of base synthetic and mineral oils. It was found that measurement accuracy was better when damping factor was estimated in comparison with accuracy of frequency of damped oscillations. Thus the oil viscosity was calibrated as a function of number of pulses of the damped oscillations of magnetoelastic ribbon. Result generally showed that developed detector is promising for in line oil viscosity measurement in wide viscosity range from 10 cSt up to 600 cSt, while the viscosity measurement was relatively instable when the viscosity of test oil was over 400 cSt.

시뮬레이션과 청감실험을 통한 공연장 형태별 음향성능 비교분석 (Comparison of the acoustical performance of auditoria by shapes using acoustic simulation and listening tests)

  • 강찬우;한찬훈
    • 한국음향학회지
    • /
    • 제42권3호
    • /
    • pp.189-202
    • /
    • 2023
  • 본연구에서는 홀의 건축형태에 따른 음향성능을 분석하였다. 홀에는 4가지 건축 형태가 있다. 장방형, 말발굽형, 서라운드형(Surround), 부채꼴형이다. 음향성능을 분석하는데 RT60, EDT, C80, BQI, LF, Gmid, G125, ITDG 총 8개의 음향인자를 사용하였으며 건축형태에 따른 음향성능을 연구하기 위해 두 가지 접근 방식을 사용하였다. 첫째 전세계 유명 콘서트홀의 측정 데이터를 분석하였다. 설문조사로 조사한 홀의 주관적 선호도와 측정된 음향 인자 사이의 관계를 회귀 분석해 상관계수 R을 얻었으며 각 공연장 형태별 음향인자 측정데이터 평균을 구하였다. 각각의 음향 인자에 대한 가중치로 상관계수 R을 사용해 각 형태별 음향 성능을 계산하였다. 그 결과 장방형 홀과 말밥굽형 홀이 좋은 음향 성능을 보였으나 부채꼴형 홀의 음향성능은 좋지 않았다. 둘째, 각 건축형태별 3D 모델을 만들어 음향 시뮬레이션을 수행했다. 동일한 체적과 흡음계수를 가지는 장방형, 말밥굽형, 서라운드형, 부채꼴형 3D 모델을 만들어 시뮬레이션을 진행해 음향인자 값을 산출하였다. 또한 형태별 3D 모델의 임펄스 응답을 사용해 가청화 시제를 만들어 청감실험을 진행하였다. 그 결과 장방형 홀과 말굽 홀이 가장 좋은 음향성능을 나타냈으며 서라운드형과 부채꼴형은 상대적으로 떨어지는 음향성능을 나타내었다.

해면 산란효과에 의한 선박 방사소음 추정치 오차 (Error Characteristics of Ship Radiated Noise Estimation by Sea Surface Scattering Effect)

  • 박규칠;박지현;서철원;최재용;이필호;윤종락
    • 한국소음진동공학회논문집
    • /
    • 제23권6호
    • /
    • pp.563-573
    • /
    • 2013
  • The ship radiated noise level fluctuates by the interference between direct and reflected paths. The effect of sea surface reflection path on interference depends strongly on sea surface roughness. This paper describes error characteristics of ship acoustic signature estimation by sea surface scattering effect. The coherent reflection coefficient which explains a magnitude of sea surface scattering and its resultant interference acoustic field is analyzed quantitatively as a function of a grazing angle, effective surface height, frequency, source-receiver range and depths of source and receiver. Theoretical interference acoustic field is compared with experimental result for two different sea surfaces and five different frequencies by changing source-receiver range. It is found that both matches well each other and a magnitude of interference acoustic field is decreasing by increasing a grazing angle, effective surface height, frequency, and depths of source and receiver and decreasing source-receiver range. For given experimental conditions, the transmission anomaly which is a bias error of ship acoustic signature estimation, is about a range of 1~3 dB. The bias error of an existing ship radiated noise measurement system is also analyzed considering wind speed, source depth and frequency.

수온약층이 존재하는 천해역 수중음향 채널의 장거리 신호 전달 특성 (Long-Range Sound Transmission Characteristics in Shallow-Water Channel with Thermocline)

  • 변성훈;김시문;임용곤
    • 한국음향학회지
    • /
    • 제33권5호
    • /
    • pp.273-281
    • /
    • 2014
  • 본 논문은 수온약층이 존재하는 제주도 근처 천해역 환경에서 획득한 수중음향 실험 데이터를 이용하여 장거리 신호 전달에 수온약층이 미치는 영향을 분석한 결과를 제시한다. 제주도 인근 해역에 서 장기간 측정된 한국해양자료센터의 수온 및 염분 관측자료는 계절에 따라 수온약층이 형성되는 것을 보여주며, 수온약층이 형성되는 시기에는 음향 신호가 해저면 방향으로 굴절하며 전파되므로 해저면에서의 반사 손실이 장거리 전파에 매우 큰 영향을 가진다. 본 연구에서는 2013년 5월에 수행한 제주 음향 통신 실험 (JACE13) 데이터를 이용하여, 수온약층이 존재할 때의 해저면 반사 손실을 추정하였다. 추정된 반사 손실은 약 3 dB 미만의 손실 값을 가지는 것으로 나타났으며, 수신기의 수심이 깊을수록 수신 신호 준위가 높게 나타났다. 이는 수온약층이 형성되는 천해역 환경에서는 수온약층 아래의 음향 트랩핑이 장거리 신호 전달의 주요 경로가 될 수 있음을 보여준다.

CAM 곡선 개선에 의한 차량용 공조기의 소음 저감 평가 (Evaluation for Noise Reduction of the HVAC by Modification of CAM Curve)

  • 정재은;정창용;서범준;정운창;오재응
    • 한국소음진동공학회논문집
    • /
    • 제21권9호
    • /
    • pp.787-797
    • /
    • 2011
  • The noise in a vehicle is an important factor for customers purchasing a car. Particularly, reduction of the noise that is generated from HVAC(heating, ventilation and air conditioning) is very important since it has considerable effects on interior noise. In general, identification of noise source is crucial to reduce noise level. The complex acoustic intensity method is widely used to obtain the accurate measurement and identification of noise source. Therefore, in the previous study, noise source of HVAC was identified through experimental approach using the complex acoustic intensity method. In this study, we are intended to confirm reduced level of noise by comparing the result between before and after modification of cam curve that is based on identified noise source of HVAC. It is found out that noise source of HVAC are motor and cam area using the complex acoustic intensity method in the previous study. We performed experiments to compare noise level between before and after modification of cam curve. Especially, it can be seen that complex acoustic intensity method using both active and reactive intensity is vital in devising a strategy for comparison to noise level. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.

소형 송풍기 소음의 음향학적 상사성에 관한 연구 (Acoustical Similarity for Small Cooling Fans Revisited)

  • 김용철;진성훈;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1995년도 춘계학술대회논문집; 전남대학교, 19 May 1995
    • /
    • pp.196-201
    • /
    • 1995
  • The broadband and discrete sources of sound in small cooling fans of propeller type and centrifugal type were investigated to understand the turbulent vortex structures from many bladed fans using ANSI test plenum for small air-moving devices (AMDs). The noise measurement method uses the plenum as a test apparatus to determine the acoustic source spectral density function at each operating conditions similar to real engineering applications based on acoustic similarity laws. The characteristics of fans including the head rise vs. volumetric flow rate performance were measured using a performance test facility. The sound power spectrum is decomposed into two non-dimensional functions: an acoustic source spectral distribution function F(St,.phi.) and an acoustic system response function G(He,.phi.) where St, He, and .phi. are the Strouhal number, the Helmholtz number, and the volumetric flow rate coefficient, respectively. The autospectra of radiated noise measurements for the fan operating at several volumetric flow rates,.phi., are analyzed using acoustical similarity. The rotating stall in the small propeller fan with a bell-mouth guided is mainly due to a leading edge separation. It creates a blockage in the passage and the reduction in the flow rate. The sound power levels with respect to the rotational speeds were measured to reveal the mechanisms of stall and/or surge for different loading conditions and geometries, for example, fans installed with a impinging plate. Lee and Meecham (1993) studied the effect of the large-scale motions like impinging normally on a flat plate using Large-Eddy Simulation(LES) and Lighthill's analogy.[ASME Winter Annual Meeting 1993, 93-WA/NCA-22]. The dipole and quadrupole sources in the fans tested are shown closely related to the vortex structures involved using cross-correlations of the hot-wire and microphone signals.

  • PDF