• 제목/요약/키워드: Acoustic Analysis

검색결과 2,491건 처리시간 0.024초

직업적인 음성과사용자들의 음성 부담에 대한 평가 (Voice Analysis of Chronic & Daily Voice Burden in Professionals)

  • 남순열;김준모;박형욱;이석우;박혜성;김상윤;유승주
    • 대한후두음성언어의학회지
    • /
    • 제12권1호
    • /
    • pp.17-21
    • /
    • 2001
  • Aims of study : The purpose of this study is to measure the chronic and daily voice burden of the professionals in their actual working places. These will be a valuable guideline for preventing and controlling the voice production of professionals. Material and method : Our study was selected to the 10 female telephone operators in the Asan Medical Center, ages ranging from 22 to 38 years old. The symptoms and acoustic analysis of both telephone operators and the controls were evaluated before and after their working. The symptoms were evaluated with questionaires, and the acoustic analysis was measured by using CSL (computerized speech laboratory) system. Results : The symptoms of the professional voice abusers are same as those symptoms in laryngeal fatigue. The acoustic analysis before their working were significantly increased in jitter and shimmer, in comparison with the data of the control. This shows that the experimental group is exposed to the chronic burden of voice production. The jitter, shimmer, and NHR after their working are significantly increased in comparison with the data of the acoustic analysis before their working. This also shows that the experimental group is exposed to the daily burden of voice production. Conclusion : The acoustic analysis of the professional voice overusers has objectively measured that there are chronic and daily overloading to the voice of operators, and these will be a valuable data for preventing and controlling the professionals that abuse their voice.

  • PDF

밸런스드 아마추어 초소형 스피커의 진동 및 음향특성 연구 (Vibration and Acoustic Analysis of Balanced Armature Micro Speaker)

  • 고동신;허덕재;권상엽;이성수
    • 한국소음진동공학회논문집
    • /
    • 제26권1호
    • /
    • pp.5-12
    • /
    • 2016
  • This paper describes the development process for vibration and acoustic characteristics of a balanced armature speaker. The design parameters were chosen in consideration of the influence of the bending stiffness of balanced armature which is the form of a cantilever structure in the speaker. For study of the performance of the speaker according to the design parameters, in the first step, we analyzed the characteristics of the velocity of the diaphragm to the electrical input. Next step, acoustic characteristics were analyzed by structural-acoustic coupled analysis. And the reliability of the analysis was verified by comparing the result of analysis with test results. Finally, we proposed a design method for implementing an enhanced balanced armature speakers through analysis method.

음향흐름에 의한 음압과 열전달 촉진과의 관계 (The Relation of Enhancement Heat Transfer to Acoustic Pressure by Acoustic Streaming)

  • 양호동;오율권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.591-596
    • /
    • 2005
  • The objectives in the present study are to investigate that the enhancement heat transfer was experimentally measured and was compared with the acoustic pressure obtained by numerical analysis. From the results of the present study, a strong Fluid motion initiated by ultrasonic vibrations can affect heat and mass transfer. This phenomenon. called acoustic streaming, clearly observed by PIV measurement leads to increase in velocity of a Fluid which is a crucial physical concept to explain the enhancement heat transfer. The heat transfer coefficient is increased with increase in the ultrasonic intensities. The largest enhancement heat transfer (about 26%) is measured at the ultrasonic intensity of 300W. Acoustic streaming results from sudden acoustic pressure variations in the liquid. The results of numerical analysis reveal that acoustic pressure is increased by 59.5% at the ultrasonic intensity of 300W. The higher acoustic pressure near four ultrasonic transducers develops more intensive flow destroying the flow instability. Also, the profiles of acoustic pressure variation are consistent with those of enhancement heat transfer.

  • PDF

로켓연소실에서 음향공의 음향학적 감쇠에 대한 정량적 고찰 (A Study on the Acoustic Damping Characteristics of Acoustic Cavities in a Liquid Rocket Combustor)

  • 김홍집;김성구;최환석
    • 항공우주기술
    • /
    • 제5권2호
    • /
    • pp.195-204
    • /
    • 2006
  • 로켓엔진에서의 고주파 연소불안정을 제어하기 위하여 널리 사용되는 음향공에 대하여, 3차원 선형 음향해석을 수행하여 음향공의 감쇠 능력을 정량화하고자 하였다. 선형음향해석에 의한 공진주파수는 상온에서 고전적 이론에 의한 공진주파수와 약 6% 압력 비에 의한 결과와는 약 10%의 차이를 보임을 확인하였다. 음향공의 개수에 따른 acoustic impedance 특성을 살펴보았고, 본 연구의 결과가 기존의 결과와 정량적으로 유사함을 확인하였다. 기하학적으로 동일한 음향공이 여러 개 설치된 연소실에서는 음향장의 특성과는 상관없이 각각의 음향공이 동일한 acoustic impedance 특성을 보임을 확인하였다. 이로써 acoustic impedance를 도입하여 음향공의 최적 동조를 위한 설계 절차를 확립하였다.

  • PDF

구조-음향 연성해석을 통한 모형차실 모델의 소음저감 기술연구 (Noise reduction of a vehicle acoustic cavity sample using coupled Structural-Acoustic element analysis)

  • 김태정;강성종;서정범
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1994년도 추계학술대회논문집; 한국종합전시장, 18 Nov. 1994
    • /
    • pp.288-294
    • /
    • 1994
  • A study of prediction and qualification techniques for structure borne booming noise is presented in this paper. Result from acoustic normal mode finite element analysis of a 1/2 size vehicle cavity sample model is compared to the that from an experiment. Coupled structural-acoustic analysis is performed on a 1/4 size vehicle cavity sample model surrounded by 2 mm thick normal steel plates. Interior noise levels around passensger's ear position are predicted and reduced by structural modification based on panel participation factor analysis about the sample cavity model. Futhermore, optimization technique in application of anti-vibration pad is studied.

  • PDF

음향 상호성 이론을 이용한 승용차 차실 판넬의 기여도 해석 (Analysis of a Panel Contribution of a Vehicle Compartment Using the Acoustic Reciprocal Theorem)

  • 김명규;박태원;이수훈
    • 한국자동차공학회논문집
    • /
    • 제2권2호
    • /
    • pp.59-72
    • /
    • 1994
  • For a panel contribution of the passenger vehicle compartment, a model was created for acoustic analysis of the passenger vehicle compartment and through the acoustic normal modal analysis, frequencies and mode shapes of the resonance modes were calculated. Also, the contribution analysis of each panel was executed using acoustic reciprocal theorem, and through this analysis, normalized responses at the particular point indicate the relative contribution of each panel for generating noise and vibration

  • PDF

직접방사형 스피커의 음향특성 해석및 설계 (Acoustic Analysis and Design of a Direct-Radiator-Type Loudspeaker)

  • 김준태;김정호;김진오
    • 소음진동
    • /
    • 제8권2호
    • /
    • pp.274-282
    • /
    • 1998
  • A systematic procedure for designing a direct-radiator-type loudspeaker has been developed, based on the numerical vibro-acoustic analysis and the Taguchi method. The finite-element model of the speaker cone has been used to calculated the vibration response of the cone excited by the voice coil. The vibration displacement of the speaker cone has been converted into the vibration velocity and used as a boundary condition for the acoustic analysis. The acoustic frequency characteristics of the loudspeaker have been calculated by the boundary element method. The numerical results have been verified by the experiments carried out in an anechoic chamber. Some design parameters have been selected by using the Taguchi method, and the variations of the acoustic characteristics due to the changes of the parameter values have been examined using the numerical model.

  • PDF

발전용 증기밸브 누설량 평가에 관한 연구 (Study on Evaluation of the Leak Rate for Steam Valve in Power Plant)

  • 이상국;박종혁;유근배
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.45-50
    • /
    • 2007
  • Acoustic emission technology is applied to diagnosis the internal leak and operating conditions of the major valves at nuclear power plants. The purpose of this study is to verify availability of the acoustic emission as in-situ diagnosis method. In this study, acoustic emission tests are performed when the pressurized high temperature steam flowed through gate valve(1st stage reheater valve) and glove valve(main steam dump valve) on the normal size of 4 and 8". The valve internal leak diagnosis system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, signal level analysis and RMS(root mean square) analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

교차로 사고음 검지시스템의 방해음향 조사연구

  • 강희구;고영권;김재이
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.805-808
    • /
    • 2008
  • 본 논문에서는 교차로 사고음 자동검지시스템의 검지율 향상을 위하여 다양한 음향패턴을 분석하였는데, 자동검지의 방해요소인 차종별 경적음과 특수목적용 차량의 사이렌음의 음향패턴은 일반적으로 사고음과 비슷한 음압을 가지고 있으나, 각각 다른 주기적인 형태의 주파수 파형으로 구성되어 있음을 확인하였다. 이를 위해, 교차로사고 자동음향감지시스템의 각종 방해요소(자동차 경적, 사이렌음, 기타 잡음 등)들의 파형 및 주파수 특성 등을 분석하는 음향인식기법을 도입하였다. 연구결과, 일반적인 교통소음과 교통사고음의 음향패턴을 비교하면 많은 차이가 있으며, 차량소통의 유무에 따라 약 20[dB]의 오차범위가 존재하는 것으로 나타났다.

  • PDF

채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구 (A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division)

  • 유병철;최흥호;노시철;민해기;권장우
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권5호
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.