• Title/Summary/Keyword: Accumulated temperature

Search Result 553, Processing Time 0.031 seconds

A Study on an Address Discharge Time Lag and a Wall-Charge Loss Due to the Potential (AC-PDP구동에서 전위차로 인한 벽전하의 소실과 어드레스 방전 지연시간에 관한 연구)

  • Jeon, Won-Jae;Kim, Dong-Hoon;Kim, Jong-Yeol;Lee, Seok-Hyun;Lee, Cheon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1315-1317
    • /
    • 2008
  • The plasma display panel is an image expression display using gas discharge. However gas discharge characteristics vary with temperature. Furthermore, the potential difference among three electrodes appears in sustain period due to external applied voltages. It affects to the wall charge state accumulated on the electrodes. This research aims at identifying that the discharge characteristics depend on the potential difference and temperature. The results show that the wall charge loss increases with increase of the number of applied pulse during sustain period and it severely appears at high temperature.

  • PDF

Diagnosis of Cast Resin Transformer Using Analysis of Surface Temperature Distribution (표면온도분포 분석을 이용한 몰드 변압기 진단)

  • Lim, Yong-Bae;Chun, Jong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.444-447
    • /
    • 2003
  • All objects with some temperature above absolute zero radiate in the infrared. The intensity of the infrared radiated from a object defends on the condition and temperature on the surface of the one. The present, these techniques are frequently adopted into diagnosis for electricity equipments. Simply, however, the applied techniques are passive thermal testing for the detection of loosened terminals and overcurrent. In this paper, a infrared thermal imager was applied to high voltage windings of cast resin transformers, and the accumulated value of the result temperatures was used for evaluating remained lifetime of them. At each aging level, dielectric loss tangent test was carried out. The results offered capabilities for deciding the condition of the transformers suffering difficulties to diagnose.

  • PDF

A Study on Hot Straining Embrittlement of Subcritical HAZ in Steel Weldments (강 용접 열영향부 취화역 의 열변형취화 에 관한 연구)

  • 정세희;김태영;임재규
    • Journal of Welding and Joining
    • /
    • v.3 no.2
    • /
    • pp.35-41
    • /
    • 1985
  • The fracture toughness of subcritical HAZ in the hot strained weldments of two structural steels(SB 41 and SA 537) has been investigated by COD test method and metallurgical study. The obtained results are summarized as follows; 1. The hot straining embitterment of subcritical HAZ depends on the hot straining amounts of notch tip, and the transition temperature( $T_{tr}$ ) increases with the accumulated hot straining amounts(.SIGMA. vertical bar .delta.$_{t}$vertical bar). 2. The fracture toughness of subcritical HAZ depends on materials and microstructure. The transition temperature( $T_{tr}$ ) of subcritical HAZ in SB 41 is almost same as that of parent material, however in SA 537 the temperature is higher than that of parent and lower than that of transformed HAZ. 3. The subcritical HAZ in SA 537 shows a higher toughness at small amounts of hot straining (.SIGMA. vertical bar .delta. $_{t}$vertical bar<0.3mm).mm).

  • PDF

A Study on the PM Oxidation Characteristics of Electrical Heater DPF System (전기히터방식 매연여과장치의 PM 산화 특성에 관한 연구)

  • Ham, Yun-Young;Kim, Dae-Ha;Kim, Kyung-Woon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.183-190
    • /
    • 2006
  • For continuously regenerative PM collecting system which adopted thermally stable SiC DPF and electrical heater which was placed upstream of the filter and driven by well constructed control logic, PM oxidation characteristics were investigated varying air flow rate, amounts of PM accumulated on the DPF and filter inlet temperature in order to get optimized PM regeneration performance. This study showed that the operating condition of air flow rate 70 lpm, high PM loading around 30g and filter inlet temperature $700^{\circ}C$ with heat insulation was effective in achieving high regeneration efficiency. Also, in this condition, we could decrease the electric energy consumption by reducing the regeneration time.

Interfacial Charge Behaviors in SXLPE/XLPE Laminates (SXLPE/XLPE laminate의 계면전하 거동)

  • 고정우;남진호;서광석
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.127-132
    • /
    • 2002
  • Space charge distributions and behaviors in silane crosslinked polyethylene(SXLPE)/ crosslinked polyethylene(XLPE) laminates were investigated using a pulsed electroacoustic (PEA) method. In case of monolayer, XLPE shows heterocharge while SXLPE shows homocharge. It was observed that charges were accumulated at the interface of SXLPE/XLPE laminate when applied electric field was more than 20kV/mm. The charge profile at various temperatures was also acquired using temperature-controllable PEA system. Although applied electric field is only 8.6 kV.mm, positive interfacial charge starts to appear near 50$^{\circ}C$. It was found that the interfacial charge behavior of SXLPE/XLPE laminate under low voltage at high temperature is corresponding to that under high voltage at room temperature.

Temporal Variation of Air Temperature in Ice-Valley at Milyang in Association with Ice Formation

  • Lee, Soon-Hwan;Hwang, Soo-Jin
    • Journal of the Korean earth science society
    • /
    • v.28 no.5
    • /
    • pp.598-602
    • /
    • 2007
  • A long-term in situ observation was carried out in the Ice-valley at Milyang in order to explain the factors and processes associated with the summertime ice formation. The variation of temperature inside Ice-valley in relation with ice formation in summer time was found to depend on precipitation rate in spring and cold air sinking in autumn and winter. The rate of temperature rising tends to correspond to sensible heat release depending on the precipitation amount at the freezing location. The reason of the cold air accumulation in a talus in the Ice-valley is the cold air sinking over the surface of talus due to the occurrence of outside clod air mass and the accumulated cold air from autumn to spring flow outside at the bottom of talus. The out-flowing cold air can result in the ice formation in the hot summer.

STUDY ON ALGORITHM FOR CALCULATION REMAINING CAPACITY OF INDUSTRIAL LEAD-ACID BATTERY (산업용 연축전지의 잔존용량 산출 알고리즘(Algorithm)에 관한 연구)

  • Lim, Gyu-Ryeong;Chun, Soon-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2187-2189
    • /
    • 2001
  • The proposed algorithm has produced the rules of relationship between the load voltage, current, discharging electric power and ampere-hours, electric power capacity of battery on the basis of the data. Which were acquired through the battery discharging experiment that is defined by the battery's ambient temperature and various load conditions. Especially, by calculating the parameter of second order polynomial equation relation between the remaining capacity and the electric power, the algorithm is proposed adapting for the discharging pattern. And as the depth of discharging is increasing, the calculation-method of electric power is applied to decrease the accumulated error in the calculation method of capacity accumulation. Also, the proposed algorithm has compensated the temperature considering the capacity change of battery to the temperature.

  • PDF

Temperature-dependent dielectric relaxation in ITO/Alq3/Al organic light-emitting diodes

  • Ahn, Joonho;Kim, Tae Wan;Lee, Won Jae
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.163-165
    • /
    • 2012
  • Impedance spectroscopy informs electrical properties of materials as accumulated charges, contact status between electrode and organic materials. We carried out impedance spectroscopy of organic light-emitting diodes as ITO/Alq3(60 nm)/Al on temperatures from 10 K to 300 K. The result described Z'-Z" plot, cole-cole plot and dielectric relaxation time τ. Z'-Z" plot means that real and imaginary part of materials in organic and electrode by frequencies and temperature. Z' as real part of impedance by applied frequency depending on temperature shows the plateau in low frequency region as Rs+ Rp and over 100 kHz in high frequency region as Rs. Cole-cole plot shows resistance of materials in equivalent circuit of the device by temperatures. And equivalent circuit and dielectric relaxation could be accomplished by using the complex impedance analysis.

Effect of External Factors on Heavy Metal Accumulation in the Cell of Heavy Metal-Tolerant Microorganisms (중금속내성균의 중금속 축적에 미치는 외부요인의 영향)

  • Cho, Ju-Sik;Lee, Hong-Jae;Lee, Won-Kyu;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.2
    • /
    • pp.124-129
    • /
    • 1997
  • This study was performed to develop the biological treatment technology of wastewater polluted with heavy metals. Heavy metal-tolerant microorganisms, such as Pseudomonas putida, P. aeruginosa, P. chlororaphis and P. stutzeri possessing the ability to accumulate cadmium, lead, zinc and copper, respectively, were isolated from industrial wastewater and mine wastewater polluted with various heavy metals. The effect of several external factors, such as temperature, pH and heavy metal compounds on heavy metal accumulation in the cells was investigated. The amount of heavy metal accumulation into cells according to the kind of heavy metal compound was slightly increased in the case of the heavy metal compound with -nitrate group, but generally, there is little change according to the kind of compound in the amount of heavy metal accumulation. The amount of heavy metal accumulation according to the precultured time was increased in the case of the cell precultured for 24 hours, but generally the precultured time did not affect to the amount of heavy metal accumulation. Heavy metal accumulation into cells was affected by several external factors, such as temperature and pH. The optimum temperature and optimum pH of the accumulation of heavy metal into cells were $20{\sim}37^{\circ}C$ and pH $6{\sim}8$, respectively. By increasing the concentration of each heavy metal-tolerant microorganism in the solution, the total amount of heavy metal accumulated was increased, whereas the amount of heavy metal accumulated per cell(mg, heavy metal/g, dry cells) was decreased. These results indicated that the amount of heavy metal accumulated was not proportional to the concentration of microorganisms.

  • PDF

Correlationship between Climatic Elements and External Characteristics of Red Pepper Fruit in Different Growing Periods (홍고추 생육시기별 기상여건과 외형적 특성과의 상관관계)

  • 조병철;박권우;강호민;윤형권
    • Journal of Bio-Environment Control
    • /
    • v.13 no.2
    • /
    • pp.73-80
    • /
    • 2004
  • Two red pepper(Capsicum annuum L.) cultivars, 'Geumtap' and 'Bugang', were cultivated at main producing areas in Korea and harvested four times in 1998 and 1999. Length, weight, dry matter ratio and color of red peppers were measured at each harvest. The relations between external characteristics with regional climatic elements such as total accumulated air temperature, total amount of precipitation and duration of sunshine during the fruit growing periods were compared. Length and fruit weight decreased by delayed harvest. These characteristics were shown significant difference according to cultivars, but not to growing year. Dry matter ratio had a tendency to increase at the 3rd and 4th harvest. The red color as measured a${\times}$L values of pepper powder, increased with being later in harvesting, but the trend was uncertain. In fruit growth, fruit length showed a positive correlation with total accumulated air temperature in later growth period of fruits(from 1st to 20th day before harvesting), and fruit weight had relationships with accumulated air temperature and total amount of precipitation in later growth period of fruit. There was no relation between dry matter ratio and climate elements. The red color was shown high correlations with total amount of precipitation and duration of sunshine. There was highest coefficient of determination($r^2$) in all external characteristics.