• 제목/요약/키워드: Accounted Water Rate

검색결과 51건 처리시간 0.03초

A successful province of agriculturalwater-saving: Gansu

  • Bin, Jiang
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.194-194
    • /
    • 2016
  • Gansu, located in the northwestern region, is a typical agricultural province of arid, semiarid in China. The shortage of water resources is the biggest obstacle of Gansu Province's development, and the dry farming water-saving is the eternal theme of Gansu agricultural sustainable development. In recent years, intensify reform in Gansu, has walked out a successful way in the agricultural water-saving. Using the integrated river basin governance as opportunity, the total water-using quantity was regarded as rigidity to retrain, distributed to counties (districts), irrigated areas, towns, associations, groups step by step. Agricultural water price was substantially increased, with the surface water price from about $0.1RMB/m^3$ to more than $0.2 RMB/m^3$, and the ground water from zero to more than $0.1RMB/m^3$. Simultaneously, the difference water prices and over-quota water progression price markup were carried out. The transaction of water rights was encouraged to impel the peasant to establish the consciousness of saving-water. The regulatory documents were formulated to standardize the scope, condition, mode, program etc. of agriculture water-rights transaction, to guarantees the transaction of water rights is carries out in order. The pattern of farming was optimized and adjusted, reducing the high water-consumption crop, increasing economic crops with high benefit and low water-consumption, developing industrialized agricultures such as green house. The relative engineering and measuring facility were comprehensively improved, with the anti-seepage of canal system and the enforcement of dynamo-electric well, developing high-efficient water-saving irrigation and overall metering facilities. The water fine-grained management has realized, and obvious water-saving effect has obtained: water-using rate in the irrigation area by river water has brought up to 0.57 from 0.52, and by well water up to 0.84 from 0.76. Although the water price has increased, the proportion that the water rate expenditure accounted for the cost lasts decline, and the farmers' income has gone up. The peasants express, the used water is few, and it is few to till land, but the income is many, and life is better.

  • PDF

종이 물성에 따른 판형 전열교환기의 성능 (Performance of a Plate-Type Enthalpy Exchanger Made of Papers Having Different Properties)

  • 김내현;조진표;송길섭;김동훈
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.547-555
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Papers having different properties were made from the same pulp by calendering or refining. Enthalpy exchanger samples were made from the papers, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were obtained, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that effective efficiency of latent heat transfer was approximately the same independent of the samples, which suggests that papers made of the same pulp show similar water vapor transmission characteristics independent of the degree of calendering or refining. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

Group Separation of Water-soluble Organic Carbon Fractions in Ash Samples from a Coal Combustion Boiler

  • Park, Seung-Shik;Jeong, Jae-Uk;Cho, Sung-Yong
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권1호
    • /
    • pp.67-72
    • /
    • 2012
  • The chemical characterization of water-soluble organic carbon in ash emitted from a coal combustion boiler has not been reported yet. A total of 5 ash samples were collected from the outlet of an electrostatic precipitator in a commercial 500 MW coal-fired power plant, with their chemical characteristics investigated. XAD7HP resin was used to quantify the hydrophilic and hydrophobic water-soluble organic carbons (WSOC), which are the fractions of WSOC that penetrate and remain on the resin column, respectively. Calibration results indicate that the hydrophilic fraction includes aliphatic dicarboxylic acids and carbonyls (<4 carbons), amines and saccharides, while the hydrophobic fraction includes aliphatic dicarboxylic acids (>4-5 carbons), phenols, aromatic acids, cyclic acid and humic acid. The average mass of the WSOC in the ash samples was found to depend on the bituminous coal type being burned, and ranged from 163 to 259 ${\mu}g$ C/g of ash, which corresponds to 59-96 mg C of WSOC/kg of coal combusted. The WSOC mass accounted for 0.02-0.03 wt% of the used ash sample mass. Based on the flow rate of flue gas produced from the combustion of the blended coals in the 500 MW coal combustion boiler, it was estimated that the WSOC particles were emitted to the atmosphere at flow rates of 4.6-7.2 g C/hr. The results also indicated that the hydrophilic WSOC fraction in the coal burned accounted for 64-82% of the total WSOC, which was 2-4 times greater than the mass of the hydrophobic WSOC fraction.

한강권역 우심지류 하천의 유기물 분포 특성 (The Distribution Characteristics of Organic Matters in the Contaminated Tributaries of Han River Region)

  • 김호섭;박윤희;김용삼;김상용
    • 한국물환경학회지
    • /
    • 제34권5호
    • /
    • pp.494-502
    • /
    • 2018
  • The purpose of this study was to understand distribution characteristics of organic matters through concentration of $BOD_5$, $COD_{Mn}$ and TOC in 31 streams in Han River region, and to establish the relationship among organic matter concentration, and discharge load and flow rate. Concentration of $BOD_5$ and TOC in 22 streams were above IV grade except 9, and the average 80.9 % of total organic matter (by TOC) accounted for dissolved organic type. Correlation among organic matter parameters were higher ($r^2$ > 0.78) and the relationship between TOC and $COD_{Mn}$ concentration was higher than $BOD_5$. Ratio of biodegradable organic matter/total organic matter in the 31 streams was estimated at 41.4 % with $BOD_5$ oxidation rate, and 78.0 % with $BOD_5/COD_{Mn}$ concentration ratio. Ratio of $NBOD/BOD_5$ concentration in four sites with $BOD_5/COD_{Mn}$ concentration ratio exceeding 1 ranged from 54.5 % ~ 79.3 %. Among 979 flow rate data measured at 31 streams, 87 % of measured data was below 0.1 cms and increased water pollution under low flow conditions. Correlation between $BOD_5$ concentration and $BOD_5$ discharge load in the watershed was low, and it was revealed that several streams have more $BOD_5$ delivery load than $BOD_5$ discharge load. Results suggest that many biodegradable forms of organic matter are being introduced into the stream from pollutant sources in the watershed.

열교환기 휜에서의 착상 거동 (Behavior of frost formed on heat exchanger fins)

  • 김정수;이관수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2334-2339
    • /
    • 2008
  • This paper proposes an improved mathematical model for predicting the frosting behavior on a two-dimensional fin considering the heat conduction of heat exchanger fins under frosting conditions. The model consists of laminar flow equation in airflow, diffusion equation of water vapor for frost layer, and heat conduction equation in fin, and these are coupled together. In this model, the change in three-dimensional airside airflow caused by frost growth is accounted for. The fin surface temperature increased toward the fin tip due to the fin heat conduction. On the contrary, the temperature gradient in the airflow direction(x-dir.) is small throughout the entire fin. The frost thickness in the direction perpendicular to airflow, i.e. z-dir., decreases exponentially toward the fin tip due to non-uniform temperature distribution. The rate of decrease of heat transfer in the airflow direction is high compared to that in the z-direction due to more decrease in the sensible and latent heat rate in x-direction.

  • PDF

공공하수처리시설에서 에너지 사용현황 및 절감방안 연구 (A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant)

  • 김종락;이가희;유광태;김동윤;이호식
    • 한국물환경학회지
    • /
    • 제36권6호
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

경북 고령군 강변여과 취수 지역의 지하수 유동 모사 및 민감도 분석 (Simulation of Groundwater Flow and Sensitivity Analysis for a Riverbank Filtration Site in Koryeong, Korea)

  • 원이정;구민호;김형수
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제11권2호
    • /
    • pp.45-55
    • /
    • 2006
  • 강변여과수 취수 방식의 도입이 고려되었던 경상북도 고령군 낙동강변의 충적대수층을 대상으로 2차원 지하수 유동모사를 수행하여, 취수정 및 주변 대수층에서의 지하수위와 하천수 유입량의 계절적 변화를 분석하였다. 개념모델의 하천 경계조건은 연평균 하천수위를 고정 수두로 설정하는 경우와 실제 관측된 시계열 자료를 이용하여 변동 수두로 설정하는 경우로 구분하여 모사를 수행하였다. 모사 결과 산정된 하천수 유입 비율은 고정하천수두 모사의 경우 연중 $74.3{\sim}87.0%$의 범위를 보이며 연평균 82.4%인 반면, 변동하천수두 모사의 경우 $52.7{\sim}98.1%$, 연평균 78.5%로 나타났다. 따라서 시기별로 변동하는 하천수위가 하천수 유입 비율에 큰 영향을 미치며, 하천수 유입 비율을 정확하게 산정하기 위해서는 변동하천수두 조건을 이용해야 하는 것으로 해석된다. 강변으로부터 취수정까지의 이격거리를 변화시키면서 모사를 반복 수행한 결과 취수정 이격거리가 커질수록 하천수 혼합 비율은 다소 감소하지만 그 영향이 수 % 정도로 매우 작게 나타났다. 강변여과 취수 시 지하수위 및 하천수 혼합비율에 영향을 미치는 인자인 대수층의 수리전도도 및 저유계수, 지하수 함양량, 취수량 등에 대한 민감도 분석을 수행하였다. 대수층의 평균 지하수위와 하천수 유입 비율은 취수량과 지하수 함양량 변화에 민감한 반면, 취수정의 지하수위는 수리전도도와 취수량에 민감한 것으로 나타났다.

합천호의 TOC 분포 특성 (Characteristics of TOC Distribution in Lake Hapcheon)

  • 성진욱;김형진;박제철
    • 한국환경과학회지
    • /
    • 제20권6호
    • /
    • pp.711-719
    • /
    • 2011
  • This study was conducted to estimate the distribution characteristics and budget of organic matter in the Lake Hapcheon. In the dry season, the concentration ranges of organic carbons were similar, but in the rainfall season, it showed about double concentrations. Changes of vertical water quality in the lake, there were no big differences with the concentration by the depth. However, it tends to be relatively high on the surface, a little low on the mid-depth and high in the lake bottom. DOC rate at TOC, it was lower than POC rate at inflow and DOC rate was higher than POC rate in the lake and discharging water. R-DOC accounted for more 80% of DOC rate in all investigated areas, therefore we judge that this R-DOC is to increase the organic carbon pollution gradually. As the result of the calculated organic carbon budget in the Lake Hapcheon, the amount of allochthonous, autochthonous and release were 3,552, 3,288, 228 tonC/year, respectively. the amount of discharge, decomposition and sedimentation were 504, 1,344, 5,520 tonC/year, respectively. According to this investigation, the changed amount of organic matter in the Lake Hapcheon recorded -300 tonC/year with the increase of 7,068 tonC/year and the decrease of 7,368 tonC/year.

연속회분식 반응 공정에서 동역학적 계수 및 미생물합성에 사용된 영양물질 산정 (Estimation of Kinetic Coefficient and Assimilated Nutrients Mass in SBR Process)

  • 지대현;신상우;이광호;이재근
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.607-612
    • /
    • 2007
  • In this study, we investigated the variations of the kinetic coefficients and Chemical Oxygen Demand (COD), N and P mass used for assimilation of a sequencing batch reactor (SBR) system with the variation of SRTs; SRTs of 7.5, 10.0, 12.5, 15.0 and 20.0 days were tested in one cycle of SBR operation to determine the optimum conditions for the operation of the SBR and estimate its COD, nitrogen and phosphorus removal efficiencies. The SBR system was operated under the conditions as follows: an operation time of 6 hours per cycle, a hydraulic retention time (HRT) of 12 hours, an influent COD loading of $0.4kg/m^3/day$, and an influent nitrogen loading of $0.068kgT-N/m^3/day$. The yield coefficient (Y) and decay rate coefficient ($k_d$) were estimated to be 0.4198 kgMLVSS/kgCOD and $0.0107day^{-1}$ by calculating the removal rate of substrate according to the variation of SRT. Considering total nitrogen amount removed by sludge waste process, eliminated by denitrification, and in clarified water effluent with reference to 150 mg/cycle of influent nitrogen amount, the percentage of nitrogen mass balance from the ratio of the nitrogen amount in effluent (N output) to that in influent (N input) for Runs 1~5 were 95.5, 97.0, 95.5, 99.5, and 95.5%, respectively, which is well accounted for, with mass balances close to 100%.

도시 소하천에서 유속, 비표면적에 따른 사상형 부착조류의 Chlorophyll-a 변화 (Variation of Filamentous Periphyton Chlorophyll-a in accordance with Water Velocity and Specific Surface Area of Media in Small Urban Stream)

  • 안창혁;주진철;이새로미;오주현;안호상;송호면
    • 한국물환경학회지
    • /
    • 제29권4호
    • /
    • pp.551-558
    • /
    • 2013
  • The feasibility of water supply as in-stream flow for Mangwall stream was analyzed in terms of water quality and cultivation periphyton using two different types of water resources (e.g., surface water and bank filtration from Han River basin) and three different types of media (e.g., tile, concrete and pebble). The concentrations of organic and inorganic contaminants from the bank filtration were lower than those from surface water by 17.5 - 55.0%. Using water samples collected from Mangwall stream, surface water, and bank filtration, chlorophyll-a, phaeopigment, and growth rate of periphyton were investigated. During 30 day incubation for each water sample, it was observed that filamentous cyanobacteria, Oscillatoriaceae, accounted for 98%, and water velocity of 5 cm/s was optimum for the in situ filamentous cyanobacteria growth. Also, it was deducted for water velocity and chl-a to have an inverse correlation. Meanwhile, the greater the specific surface area of media, the higher the concentration of chl-a. From these results, both water velocity and specific surface area of media should be considered as an combined parameter to deter the growth of filamentous cyanobacteria.