• Title/Summary/Keyword: Access Floor Systems

Search Result 19, Processing Time 0.023 seconds

Prediction of Stratification Model for Diffusers in Underfloor Air Distribution System using the CFD (CFD를 활용한 바닥공조시스템 디퓨저의 성층화 모델 예측)

  • Son, Jeong-Eun;Yu, Byeong-Ho;Pang, Seung-Ki;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.105-110
    • /
    • 2017
  • Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings. UFAD systems use the underfloor plenum beneath a raised access floor to provide conditioned air through floor diffusers that create a vertical thermal stratification during cooling operations. Thermal stratification has significant effects on energy, indoor air quality, and thermal comfort performance. The purpose of this study was to characterize the influence of a linear bar grille diffuser on thermal stratification in both interior and perimeter zones by developing Gamma-Phi based prediction models. Forty-eight simulations were carried out using a Computational Fluid Dynamics (CFD) technique. The number of diffusers, the air flow supply, internal heat gains, and solar radiations varied among the different cases. Models to predict temperature stratification for the tested linear bar grille diffuser have been developed, which can be directly implemented into dynamic whole-building simulation software such as EnergyPlus.

Optimal Supply Scheme of Solar Hot Water Heating Systems for the Apartment Complexes (공동주택용 태양열 급탕시스템 최적공급 방안 해석연구)

  • Lee, Chul-Sung;Park, Ja-Son;Park, Jae-Wan;Shin, U-Cheul;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.245-250
    • /
    • 2008
  • This study is on the availability of solar thermal energy in Korean high-rise apartment complex depending on the installation type of solar collectors to roof or facade of building. Firstly, solar access evaluation on the roof and the facade of apartment buildings was carried out. The total thermal load of each apartment unit and building was investigated and matched with the energy which was produced by solar thermal systems on the facade. The considered layout patterns of apartment buildings were '一type', 'alternative 一type', 'ㄱtype' and 'ㅁtype' and that was analyzed in prior studies. Extensive dynamic hourly energy simulations with the solar thermal system were Performed with the TRNSYS of SEL. We assumed that the apartment complex is composed of 9 buildings and located in Daejeon. The collectors are the heat-pip evacuated tube collectors and the number of collectors are 45 tubes We assumed that the collectors are installed on the balcony of each unit and the angle of incilnation is $90^{\circ}$. As a result, the supply amount of solar thermal systems is about 4,850,086kJ/hr and the solar fraction is about 66%. The solar fraction according to each azimuth is about 66% on the south, 62% on the south-east $30^{\circ}$ and 56% on the south-east $60^{\circ}$. So, we quantitatively got a line on the optimal azimuth for installing the solar thermal systems. The solar fraction has differences from 5% to 15% of each floor, 6th, 12th and 20th and those tendencies are same in analyzed each 4 types of the apartment complexes.

  • PDF

Design of kitchen cabinet using complex link mechanism (복합 링크기구를 이용한 주방 상부장 설계)

  • Geon-Hyeok Lim;Kibum Shim;Hoon Shim;Jiwon Jang;Sang-Hyun Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.429-434
    • /
    • 2023
  • Kitchen cabinets are essential furniture for storing the kitchen tools, but their high installed location makes it difficult for users to access the upper of the cabinets. Therefore, in this paper, we propose a new type of kitchen cabinet that allows users to easily take out or store items by adding new height adjustment features while maintaining the function of the existing cabinet. For convenience and safety, an appropriate complex link mechanism is designed so that the selected floor, not the entire cabinet, can come down to a desired height with one operation. Moreover, the optimal descent path is set to prevent the floor tilting or interfloor interference during descent, and appropriate link shapes, lengths, and joint types are selected to implement it. FEA analysis is performed to ensure that the stretched complex linkage can support the load of the stored items and the feasibility of the height adjustable kitchen cabinet is verified through fabrication.

A Study on the Space Composition for Department of Kidney Dialysis in Regional Public Hospital(1) (지역거점 공공병원의 인공신장부 공간구성에 관한 연구(1))

  • Chai, Choul Gyun;Park, Kyeong Hyeon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.2
    • /
    • pp.31-38
    • /
    • 2022
  • Purpose: This study presents the results of the analysis on space utilization of kidney dialysis units in regional public hospitals, which plays a key role in local public medical services. The result aims to achieve safety from infection, allow comfort for the dialysis environment, and stability for medical support. The purpose of this study is to present fundamental data for architectural plans for the kidney dialysis unit, as well as to alleviate potential infectious diseases such as COVID-19. Methods: For research purposes, the investigation and analysis of space utilization were based on architectural floor plans, research papers and literature, related legal systems, and public statistics. Of the main 35 regional public hospitals, in regards to data accessibility, 15 facilities were selected to conduct the survey and analysis for the objective. Results: The space composition by area research results of kidney dialysis units in public hospitals are as follows: Firstly, most targets do not have required rooms in the access and support area, except for the hemodialysis beds in the treatment section. Secondly, the access area requires necessary room and space design that took into consideration of convenience and accessibility for patients. Thirdly, in regards to infection prevention and control, proper circulation and room plan is essential for storage and disposal of contaminated products and linen after use. For the treatment area, the arrangement plan needs to establish a visual connection between the isolation room, the nursing station, and the bed area. Additionally, consideration of circulation in the preparation, treatment, observation, examination, and all other rooms in the facility is required. Lastly, for the support area, the room is designed to consider adequate working and meeting spaces for the medical staff, consultation space for patients or guardians, separate storage and disposal of clean and contaminated items, and the storage of various equipment for dialysis. Implications: In preparation for the increase in chronic kidney failure patients and the spread of infectious diseases, such as COVID-19, the researched data demonstrates the basic guidelines for space composition of kidney dialysis units and the significant role of regional public hospitals.

Evaluation of an Efficient Channel Estimator for the STTD Schemes

  • Kim, Seong-Hwan;Na, Cheol-Hun;Ryoo, Sang-Jin;Hwang, In-Tae
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.3
    • /
    • pp.185-193
    • /
    • 2007
  • This paper evaluates the performance combining space-time transmit diversity (STTD) and an efficient channel estimator (ECE) for wideband code division multiple access (WCDMA) systems in various mobile channels. Using decision variable (DV), we also derive the analytic bit error rate (BER) and mean square error (MSE) for WCDMA applying ECE for STTD schemes. The simulation results show that the ECE performance is superior to the previous works in [1] as because we use additional pilot diversity which is so called secondary common control physical channel (S-CCPCH). The performance in case of the channel estimator using only one-channel or two-channel is worse than that of an ECE as about the maximum 4 dB at BER 1.0E-3 satisfying voice service over Rician fading channel. Our results show that, even with ICE, an ECE algorithm are effective in improving the output SNR and significantly reduce the error floor. In addition, the simulation results investigated in this paper also reveal that WCDMA combining an ECE and the STTD scheme could provide appreciable performance improvements in Rayleigh fading channel.

Study Improvement of the Evacuation Performance in a Double-Skin Structure (이중외피 구조 건축물의 피난성능 개선에 관한 연구)

  • Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.98-107
    • /
    • 2017
  • This study examined an effective way of measuring the evacuation performance in buildings, which are applied to a double skin facade through an evaluation of the escape safety. Buildings with a double skin facade appeared to have a faster combustion expansion speed for the upper floor if a fire occurs. Moreover, a double skin facade is more difficult to escape safely than a general building construction because of the limited design standards. Accordingly, this study suggested virtual modeling including single emergency stairs and alarm systems considering the risk in each structure of buildings. These results showed that box-type double skin, corridor access type, shaft-box type, and multistory facade systems showed a 26.4%, 29.1%, 23.4%, and 26.3% increase in evacuation performance, respectively, as well as securing the safety of occupants.

A Study on the Space Composition for Department of Delivery in Regional Public Hospital (지역거점 공공병원의 분만부 공간구성에 관한 연구(1))

  • Park, Kyeong Hyeon;Shin, Hwa Kyoung;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.3
    • /
    • pp.47-54
    • /
    • 2022
  • Purpose: This study presents the analysis on space usage of delivery departments in regional public hospitals. The results intention is to achieve improvement of the delivery environment for the mothers and newborns regarding exposure prevention and efficient infection control. The purpose of this study is to provide fundamental data for architectural plans and guidelines for the delivery department. Method: The investigation and analysis were based on research papers, legal systems, public medical statistical data, and the architectural floor plan drawing. For research, 20 regional public hospitals with an operating delivery room were excluded. Regarding data accessibility, 15 regional public hospitals were selected. Results: To overcome the increased vulnerability of the delivery department, the research results of basic data is provided for the establishment to address urgent needs and rapid response. Thus, the research results are as follows: Firstly, the delivery department needs to respond promptly according to the type of patients. For example, in a case of emergency surgery, a connected circulation plan with the related departments is needed. Secondly, for the environment of the delivery area, alleviating anxiety is imperative for pregnant patients and guardians, labor, childbirth, and recovery. Therefore, these needs must be addressed for treatment space and circulation. Lastly, the delivery department is classified into three areas for analysis: access area, treatment area, and support area. In most of the delivery departments of the 15 selected hospitals, there is no space for the access and support area except for the labor and delivery rooms in the treatment area. For the access area, a waiting area, changing room for pregnant women and guardians, and a storage space for contaminated linens are required for infection prevention, safety, and efficiency. For the treatment area, childbirth processes and circulation should have space reserved for labor, delivery, recovery, examination, and treatment. In preparation for an emergency during childbirth, emergency response measures and supporting space needs to be established. For the support area, circulation and rooms are to be designed for medical staff support, activity space, storage and transportation of equipment, and urgent medical treatment. Implications: Along with the low fertility rate and the decrease of medical institutions that operate delivery departments, for the purpose of establishing a public medical service system and a healthy medical environment for mothers and newborns, the researched information demonstrates basic data on space plan of delivery departments in regional public hospitals.

Design of lift-down kitchen cabinet for elderly and disabled (고령자 및 장애인을 위한 승강형 주방 상부장 설계)

  • Kibum Shim;Hoon Shim;Geon-Hyeok Lim;Jiwon Jang;Sang-Hyun Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.465-470
    • /
    • 2024
  • Kitchen cabinets are widely used for their spacious storage and efficient use of space, but their high installed location makes it difficult for the elderly and disabled to access. Therefore, in this paper, we propose a new height-adjustable kitchen cabinet that can be used more easily and safely. The lift-down range of cabinet was set considering the installation location of cabinet for efficient use of kitchen space and the maximum height accessible to the elderly and disabled, and the link geometry and driving method of the complex link mechanism were determined through the mechanism design procedure to ensure that the selected floor come down safely along the optimal descend path. In addition, the appropriate motor and control algorithm were added to allow the user to descend to the desired height with a simple button operation. It was confirmed through actual production that the proposed linkage mechanism performs the desired lift-down motion.

Development of Self-Managed Food Sanitation Check-List and On-Site Monitoring of Food Sanitation Management Practices in Restaurants for Control of Foodborne Illness Risk Factors (식중독 발생 위험요인 관리를 위한 외식업체 자가위생관리점검표 개발 및 현장모니터링)

  • Chung, Min-Jae;Choi, Jung-Hwa;Ryu, Kyung;Kwak, Tong-Kyung
    • Korean journal of food and cookery science
    • /
    • v.26 no.5
    • /
    • pp.603-616
    • /
    • 2010
  • Based on recent dramatic increases in foodborne outbreaks in restaurants, self-managed sanitation systems are now recommended to control contributing risk factors. This study aimed to improve sanitation management practices in restaurants and had two objectives. First, we tried to develop a self-managed sanitation check-list, including risk factors contributing to foodborne illness and Korean food hygiene regulation articles. We also tried to evaluate current sanitation management practices in restaurants according to operation and restaurant type. Thirty restaurants were evaluated by on-the-spot inspectors using an auditing tool consisting of four dimensions, seventeen categories, and forty-one items. Total compliance rate categorized by operation type significantly differed between chain restaurants and self-managed restaurants, with values of 85.5% and 51.6%, respectively. Therefore, self-managed restaurants, which showed the lowest compliance rate of below 30.0%, need more strict control to improve current unsanitary management practices, specifically relating to 'sterilization of knives, chopping boards, and wiping cloths', 'sanitation training', 'not allowing access into the kitchen to outsiders', 'handling of food or utensils on shelves at a 15 cm distance away from floor', 'prevention of cross-contamination of cooked foods or vegetables', and 'records of kitchen access or inspection'. Thus, an effective food sanitation system is essential and should be implemented to improve the existing sanitary conditions in restaurants. However, the most important factor to achieving food sanitation management objectives is food handlers' self-motivation.