• Title/Summary/Keyword: Acceleration Pattern

Search Result 231, Processing Time 0.03 seconds

Unsteady RANS computations of turbulent flow in a high-amplitude meandering channel (고진폭 만곡수로에서 난류흐름의 비정상 RANS 수치모의)

  • Lee, Seungkyu;Paik, Joongcheol
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.2
    • /
    • pp.89-97
    • /
    • 2017
  • Turbulent flow structure in the high amplitude meandering channel is complex due to secondary recirculation with helicoidal motions and shear layers formed by flow separation from the curved sidewall. In this work, the secondary flow and the superelevation of the water surface produced in the high-amplitude Kinoshita channel are reproduced by the unsteady Reynolds-averaged Navier-Stokes (RANS) computations using the VOF technique for resolving the variation of water surface elevation and three statistical turbulence models ($k-{\varepsilon}$, RNG $k-{\varepsilon}$, $k-{\omega}$ SST). The numerical results computed by a second-order accurate finite volume method are compared with an existing experimental measurement. Among applied turbulence models, $k-{\omega}$ SST model relatively well predicts overall distribution of the secondary recirculation in the Kinoshita channel, while all three models yield similar prediction of water superelevation transverse slope. The secondary recirculation driven by the radial acceleration in the upstream bend affects the flow structure in the downstream bend, which yields a pair of counter-rotating vortices at the bend apex. This complex flow pattern is reasonably well reproduced by the $k-{\omega}$ SST model. Both $k-{\varepsilon}$ based models fail to predict the clockwise-rotating vortex between a pair of counter-rotating vortices which was observed in the experiment. Regardless of applied turbulence models, the present computations using the VOF method appear to well reproduce the superelevation of water surface through the meandering channel.

Development of Gait Distance Measurement System Based on Inertial Measurement Units (관성측정장치를 이용한 보행거리 측정 시스템 개발)

  • Lee, K.H.;Kang, S.I.;Cho, J.S.;Lim, D.H.;Lee, J.S.;Kim, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.161-168
    • /
    • 2015
  • In this paper, we present an inertial sensor-based gait distance measurement system using accelerometer, gyroscope, and magnetometer. To minimize offset and gain error of inertial sensors, we performed the calibration using the self-made calibration jig with 9 degrees of freedom. For measuring accurate gait distance, we used gradient descent algorithm to remove gravity error and used analysis of gait pattern to remove drift error. Finally, we measured a gait distance by double-integration of the error-removed acceleration data. To evaluate the performance of our system, we walked 10m in a straight line indoors to observe the improvement of removing error which compared un-calibrated to calibrated data. Also, the gait distance measured by the system was compared to the measurement of the Vicon motion capture system. The evaluation resulted in the improvement of $31.4{\pm}14.38%$(mean${\pm}$S.D.), $78.64{\pm}10.84%$ and $69.71{\pm}26.25%$ for x, y and z axis, respectively when walked in a straight line, and a root mean square error of 0.10m, 0.16m, and 0.12m for x, y and z axis, respectively when compared to the Vicon motion capture system.

  • PDF

Seismic Performance Evaluation of a Cone-type Friction Pendulum Bearing System (원추형 마찰진자베어링의 내진성능평가)

  • Jeon, Bub-Gyu;Chang, Sung-Jin;Park, Kyung-Rock;Kim, Nam-Sik;Jung, Duk-Young
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.23-33
    • /
    • 2011
  • In this study, a CFPBS (Cone-type Friction Pendulum Bearing System) was developed which controls the acceleration delivered to the structure to prevent damage and degradation of the critical communication equipment in case of an earthquake. The isolation performance of the CFPBS was evaluated by numerical analysis. The CFPBS was manufactured in the shape of a cone differenced from the existing FPS (Friction Pendulum System), and a pattern was engraved on the friction surface. The natural frequencies of the CFPBS were evaluated from a free-vibration test with the seismic isolator system consisting of four CFPBSs. In order to verify its earthquake-resistant performance, a numerical analysis program was created from the equation of the CFPBS induced from the equations of motion. A simplified theoretical equation of the CFPBS was proposed to manufacture the equipment which could demonstrate the necessary performance. Artificial seismic waves satisfying the maximum earthquake scale of the Korean Building Code-Structural (KBC-2005) were created and verified to review the earthquake-resistant performance of the CFPBS by numerical analysis. The superstructural mass of the CFPBS and skew angle of the friction surface were considered for numerical analysis with El Centro NS (1940), Kobe NS (1995) and artificial seismic waves. The CFPBS isolation performance evaluation was based on the results of numerical analysis and the executed comparative analysis between the results from numerical analysis and the simplified theoretical equation under the same conditions.

The Kinematic Analysis of Horizontal Velocity and Records from Start to Finish of the Elite Women 100m Hurdler (엘리트 여자 100m 허들선수의 스타트에서 피니쉬까지 구간별 수평속도 및 기록에 관한 운동학적 분석)

  • Lee, Jung-Ho;Ryu, Jae-Kyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.31-39
    • /
    • 2007
  • The purpose of this study was to observe the kinematic pattern of elite women 100m hurdler race from start to finish and analyze how the change of horizontal velocity makes an influence on the athletes' performance. The analysis was based on the performance of Korean elite 100m hurdler A and international elite hurdlers B and C. Following results were drawn from the analyzation of elite 100m hurdlers' technical characteristics; During the race, hurdler A made more than 8 m/s of horizontal velocity at the 3rd, 4th, 6th, and the 7th hurdle. The horizontal velocity peaked at the 4th hurdle with 8.23 m/s. On the other hand, hurdler B and hurdler C maintained more than 8 m/s of horizontal velocity from the 2nd hurdle through the 10th hurdle. Hurdler B's fastest horizontal velocity was 8.67 m/s from the 6th to the 7th hurdle and hurdler C's fastest horizontal velocity was 8.85 m/s from the 5th to the 8th hurdle. From the start line to the 3rd hurdle, the times achieved by hurdlers A, B, and C were 4.90 sec, 4.65 sec, and 4.52 sec. In the middle of the race, which is from the 4th hurdle to the 7th hurdle, hurdlers A, B, and C ran in 9.10 sec, 8.60 sec, and 8.38 sec. And the latter part of the race to the 10th hurdle, the times hurdlers A, B, and C hit were 12.32 sec, 11.66 sec, and 11.32 sec. To the finish line, it took 1.15 sec for hurdler A, 1.1 sec for B, and 1.06 sec for C. Hence, to set the record of sub-13 sec, hurdler A should improve her acceleration from the start line to the 1st hurdle with the speed more than 5.4 m/s and should maintain more than 8 m/s of horizontal velocity from the 2nd hurdle through the 10th hurdle. In addition, hurdler A should improve her speed endurance to minimize the deceleration of horizontal velocity from the 4th hurdle to the final hurdle. If hurdler A could shorten 0.05 sec of time in each hurdle section, she would be able to set the record under 13 seconds.

Fall Detection for Mobile Phone based on Movement Pattern (스마트 폰을 사용한 움직임 패턴 기반 넘어짐 감지)

  • Vo, Viet;Hoang, Thang Minh;Lee, Chang-Moo;Choi, Deok-Jai
    • Journal of Internet Computing and Services
    • /
    • v.13 no.4
    • /
    • pp.23-31
    • /
    • 2012
  • Nowadays, recognizing human activities is an important subject; it is exploited widely and applied to many fields in real-life, especially in health care and context aware application. Research achievements are mainly focused on activities of daily living which are useful for suggesting advises to health care applications. Falling event is one of the biggest risks to the health and well-being of the elderly especially in independent living because falling accidents may be caused from heart attack. Recognizing this activity still remains in difficult research area. Many systems equipped wearable sensors have been proposed but they are not useful if users forget to wear the clothes or lack ability to adapt themselves to mobile systems without specific wearable sensors. In this paper, we develop a novel method based on analyzing the change of acceleration, orientation when the fall occurs and measure their similarity to featured fall patterns. In this study, we recruit five volunteers in our experiment including various fall categories. The results are effective for recognizing fall activity. Our system is implemented on G1 smart phone which are already plugged accelerometer and orientation sensors. The popular phone is used to get data from accelerometer and results showthe feasibility of our method and significant contribution to fall detection.

Immunological Characteristics of Hyperprogressive Disease in Patients with Non-small Cell Lung Cancer Treated with Anti-PD-1/PD-L1 Abs

  • Kyung Hwan Kim;Joon Young Hur;Jiae Koh;Jinhyun Cho;Bo Mi Ku;June Young Koh;Jong-Mu Sun;Se-Hoon Lee;Jin Seok Ahn;Keunchil Park;Myung-Ju Ahn;Eui-Cheol Shin
    • IMMUNE NETWORK
    • /
    • v.20 no.6
    • /
    • pp.48.1-48.11
    • /
    • 2020
  • Hyperprogressive disease (HPD) is a distinct pattern of progression characterized by acceleration of tumor growth after treatment with anti-PD-1/PD-L1 Abs. However, the immunological characteristics have not been fully elucidated in patients with HPD. We prospectively recruited patients with metastatic non-small cell lung cancer treated with anti-PD-1/PD-L1 Abs between April 2015 and April 2018, and collected peripheral blood before treatment and 7-days post-treatment. HPD was defined as ≥2-fold increase in both tumor growth kinetics and tumor growth rate between pre-treatment and post-treatment. Peripheral blood mononuclear cells were analyzed by multi-color flow cytometry to phenotype the immune cells. Of 115 patients, 19 (16.5%) developed HPD, 52 experienced durable clinical benefit (DCB; partial response or stable disease ≥6 months), and 44 experienced non-hyperprogressive progression (NHPD). Patients with HPD had significantly lower progression-free survival (p<0.001) and overall survival (p<0.001). When peripheral blood immune cells were examined, the pre-treatment frequency of CD39+ cells among CD8+ T cells was significantly higher in patients with HPD compared to those with NHPD, although it showed borderline significance to predict HPD. Other parameters regarding regulatory T cells or myeloid derived suppressor cells did not significantly differ among patient groups. Our findings suggest high pre-treatment frequency of CD39+CD8+ T cells might be a characteristic of HPD. Further investigations in a larger cohort are needed to confirm our results and better delineate the immune landscape of HPD.

INFLUENCE OF TOPICAL IRRIGATION USING THE HA & PURE Ti IMPLANTS ON BONE FORMATION;A STUDY ON THE IRRADIATED RABBIT TIBIA (방사선 조사후 매식한 임프란트와 관주에 따른 골치유에 대한 비교연구)

  • Hong, Sung-Pal;Rhee, Gun-Joo;Cha, Yong-Doo;Oh, Se-Jong;Hyun, Jung-Min;Choi, Dong-Joo;Park, Young-Joo;Park, Jon-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.1
    • /
    • pp.59-72
    • /
    • 2000
  • In this study, the rate of bone formation and the pattern of bone to implant contact surface around HA coated implant and pure Ti implant inserted into the irradiated tibia of rabbit were compared. Sixteen mongrel mature male rabbits were used as experimental animal. Each rabbit received 15 Gy of irradiation. Four weeks after irradiation, two holes were prepared on the tibia of each rabbit for placement of HA coated type and pure Ti type implants. Prior to implant placement, one group received steroid irrigation and the control group was similarly irrigated with normal saline. This was immediately followed by placement of the two different types of implants. Postoperatively, tetracycline was injected intramuscularly for 3 days. For fluorescent labelling, 3 days of intramuscular alizarine red injection was given. 2 weeks before sacrifice, followed by intramuscular calcein green on the last 3 days before specimen collection. Each rabbit was sacrificed on the second, fourth, sixth and eighth week after the implantation. The specimens were observed by the light microscope and the fluorescent microscope. The results were as follows; 1. All implants inserted into the irradiated tibia of rabbit were free from clinical mobility and no signs of bony resorption were noted around the site of implant placement. 2. Under the light microscope, new bone formation proceeded faster around implants that received steroid irrigation compared to the control group irrigated with saline. Bone to implant contact surface was greater in the steroid irrigated group than the saline irrigated group. Therefore, better initial stabilization was observed in the group pretreated with steroid irrigation. 3. Under the light microscope. HA coated implants showed broader bone to implant contact surface than pure Ti implants, and HA coated implants had better bone healing pattern than pure Ti implants. 4. In the steroid pretreated group, acceleration of bone formation was demonstrated by fluorescent microscopy around the 2, 4 weeks group and the 6 weeks HA coated implant group. The difference in the rate of bone formation proved to be statistically significant(P<0.05). Faster bone formation was noted in the saline irrigated group in the 6 weeks pure Ti implants and 8 weeks group. The difference was not statistically significant(P<0.05). 5. For the rabbits that were sacrificed on the second and fourth week after the implant placements, the rates of bone formation around HA coated implants proceeded faster than those around pure Ti implants under the fluorescent microscopy. For the rabbits that were sacrificed on the sixth week after the implant placements, the rates of bone formation around pure Ti implants proceeded faster than those around HA coated implants under the fluorescent microscopy. But this result did not show statistical significance (P<0.05) For the rabbits that were sacrificed on the eighth week after the implant placements, the rates of bone formation around HA coated implants proceeded faster than those around pure Ti implants under the fluorescent microscopy. This result was statistically significant (P<0.05).

  • PDF

The Individual Discrimination Location Tracking Technology for Multimodal Interaction at the Exhibition (전시 공간에서 다중 인터랙션을 위한 개인식별 위치 측위 기술 연구)

  • Jung, Hyun-Chul;Kim, Nam-Jin;Choi, Lee-Kwon
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.2
    • /
    • pp.19-28
    • /
    • 2012
  • After the internet era, we are moving to the ubiquitous society. Nowadays the people are interested in the multimodal interaction technology, which enables audience to naturally interact with the computing environment at the exhibitions such as gallery, museum, and park. Also, there are other attempts to provide additional service based on the location information of the audience, or to improve and deploy interaction between subjects and audience by analyzing the using pattern of the people. In order to provide multimodal interaction service to the audience at the exhibition, it is important to distinguish the individuals and trace their location and route. For the location tracking on the outside, GPS is widely used nowadays. GPS is able to get the real time location of the subjects moving fast, so this is one of the important technologies in the field requiring location tracking service. However, as GPS uses the location tracking method using satellites, the service cannot be used on the inside, because it cannot catch the satellite signal. For this reason, the studies about inside location tracking are going on using very short range communication service such as ZigBee, UWB, RFID, as well as using mobile communication network and wireless lan service. However these technologies have shortcomings in that the audience needs to use additional sensor device and it becomes difficult and expensive as the density of the target area gets higher. In addition, the usual exhibition environment has many obstacles for the network, which makes the performance of the system to fall. Above all these things, the biggest problem is that the interaction method using the devices based on the old technologies cannot provide natural service to the users. Plus the system uses sensor recognition method, so multiple users should equip the devices. Therefore, there is the limitation in the number of the users that can use the system simultaneously. In order to make up for these shortcomings, in this study we suggest a technology that gets the exact location information of the users through the location mapping technology using Wi-Fi and 3d camera of the smartphones. We applied the signal amplitude of access point using wireless lan, to develop inside location tracking system with lower price. AP is cheaper than other devices used in other tracking techniques, and by installing the software to the user's mobile device it can be directly used as the tracking system device. We used the Microsoft Kinect sensor for the 3D Camera. Kinect is equippedwith the function discriminating the depth and human information inside the shooting area. Therefore it is appropriate to extract user's body, vector, and acceleration information with low price. We confirm the location of the audience using the cell ID obtained from the Wi-Fi signal. By using smartphones as the basic device for the location service, we solve the problems of additional tagging device and provide environment that multiple users can get the interaction service simultaneously. 3d cameras located at each cell areas get the exact location and status information of the users. The 3d cameras are connected to the Camera Client, calculate the mapping information aligned to each cells, get the exact information of the users, and get the status and pattern information of the audience. The location mapping technique of Camera Client decreases the error rate that occurs on the inside location service, increases accuracy of individual discrimination in the area through the individual discrimination based on body information, and establishes the foundation of the multimodal interaction technology at the exhibition. Calculated data and information enables the users to get the appropriate interaction service through the main server.

The effect of chitosan/ACS on bone regeneration in rat calvarial defects (백서두개골 결손부에서 키토산/흡수성 콜라겐 전달체의 골재생)

  • Kim, Soo-Kyoung;Suk, Hun-Joo;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.457-474
    • /
    • 2003
  • The ultimate objective of periodontal treatment is to get rid of an on-going periodontal disease and further regenerate the supporting tissue, which is already destroyed, functionally. Currently, the bone grafting operation using various kinds of bone grafting materials and the operation for induced regeneration of periodontal tissue using the blocking membrane are performed for regeneration of the destroyed periodontal tissue. However, there are respective limitations Galenical preparations, which are used for regeneration of periodontal of tissue, has less risk of rejective reaction or toxicity that may be incidental to degradation and their effect is sustainable. Thus, in case they are applicable to a clinic, they can he used economically. Chitosan has such compatibility, biological actions including antibacterial activity, acceleration of wound treatment, etc., and excellent mechanical characteristics, which has recently aroused more interest in it. Also, it has been reported that it promotes osteogenesis directly or indirectly by functioning as a matrix to promote migration and differentiation of a specific precussor cell (for example, osteoblast) and further inhibiting the function of such a cell as fibroblast to prevent osteogenesis. In this study, the pure chitosan solution, which was obtained by purifying chitosan, was used. However, since this chitosan is of a liquiform, it is difficult to sustain it in a defective region. It is, therefore, essential to use a carrier for delivering chitosan to, and sustaining it gradually in the defective region. In the calvarial defect model of the Sprague-Dawley rat, it is relatively easy to maintain a space. Therefore, in this study, the chitosan solution with which ACS was wetted was grafted onto the defective region, For an experimental model, a calvarial defect of rat m s selected, and a critical size of the defective region was a circular defect with a diameter of 8 mm. A group in which no treatment was conducted for the calvarial defect was set as a negative control group. Another group in which treatment was conducted with ACS only was set as a positive control group (ACS group). And another group in which treatment was conducted was conducted with by grafting the pure chitosan solution onto the defective region through ACS which was wetted with the chitosan solution was set an experimental group (Chitosan/ACS group). Chitosan was applied to the Sprague-Dawley rat's calvarial bone by applying ACS which was wetted with the chitosan solution, and each Sprague-Dawley rat was sacrificed respectively 2 weeks and 8 weeks after the operation for such application. Then, the treatment results were compared and observed histologically and his tometrically. Thereby, the following conclusions were obtained. 1. In the experimental group, a pattern was shown that from 2 weeks after the operation, vascular proliferation proceeded and osteogenesis proceeded through osteoblast infiltration, and at 8 week after the operation, ACS was almost absorbed, the amount of osteogensis was increased and many osteoid tissue layers were observed. 2. At 2 weeks after the operation, each amount of osteogenesis appeared to be 8.70.8 %, 13.62.3 % and 4.80.7 % respectively in the experimental group, the positive control group and the negative control group. Accordingly, it appeared to be higher in the Experimental group and the positive control group than in the negative control group, but there was no significant difference statistically (p<0.01). 3. At 8 weeks after the operation, each amount of osteogenesis appeared to be 62.26.1%, 17.42.5 % and 8.21.4 % respectively in the experimental group, the positive control group and the negative control group. Accordingly, it appeared to be substantially higher in the experimental group than in the positive control group and the negative control group, and there was a significant difference statistically (p<0.01). As a result of conducting the experiment, when ACS was used as a carrier for chitosan, chitosan showed effective osteogenesis in the perforated defective region of the Sprague-Dawley rat's calvarial bone.

A Study on Classroom Interactions by Student's Cognitive Level in the Performance of Controlling Variable Tasks (변인통제 문제해결 활동에서 학생들의 인지수준에 따른 상호작용 분석)

  • Nam, Jeong-Hee;Kim, Sung-Hee;Kang, Soon-hee;Park, Jong-Yoon;Choi, Byung-Soon
    • Journal of The Korean Association For Science Education
    • /
    • v.22 no.1
    • /
    • pp.110-121
    • /
    • 2002
  • In this study, the verbal interactions occurred during the CASE(Cognitive Acceleration through Science Education) activities in the middle school science class has been analyzed regarding with students cognitive level. The subjects were 24 students of 6 groups in a middle school in Korea. Verbal interactions within group discussions during CASE activities were audio-taped, transcribed, and analyzed. Also, classroom observation and interview with students were carried out. The results showed that the student with higher cognitive level tended to be a group leader. They had strong influences on the group discussions in each step of problem solving. Also, the higher cognitive level students were more active in metacognitive discussion and more often used scientific terms. When their group met difficulties in each stage of problem solving, such as perception of problem and designing experiment, the higher cognitive level students suggested some ideas to help their peers and gave them an explanation of how they worked. Low cognitive level students had difficulties in perception and solving the problem as compared with high cognitive students. It was common during activities for the low cognitive level students to fail to identify variables and to distinguish between dependent variables and independent variables. They failed to hold a number of variables at once. However, the metacognitive questions from their peers or teacher were helpful for them to construct the concept of controlling variables. If there is no student who has a high level of thinking in a group, it was necessary to intervene for teacher. A well judged questions from teacher created the cognitive conflict which causes the students to reconstruct their strategy for problem solving and reinforce the control of variables reasoning pattern. From the above results, it is concluded that students' cognitive levels are much related to the verbal interaction patterns. This suggests that teacher should consider individual student's cognitive level in organizing groups and intervene to facilitate the environment for metacognitive interaction.