• Title/Summary/Keyword: Accelerating Degradation

Search Result 74, Processing Time 0.025 seconds

An Accelerated Degradation Test of a Electronics Appliance Compressor (전자제품용 컴프레서의 가속열화시험에 관한 연구)

  • Lee, Hoo-Jin;Yun, Won-Young
    • Journal of Applied Reliability
    • /
    • v.10 no.1
    • /
    • pp.25-38
    • /
    • 2010
  • In this paper, an accelerated degradation test procedure for an electronic appliance compressor is proposed. We investigate the amount of wear of the compressor and consider several factors as accelerating factors. Finally we select the operating pressure as a main accelerating factor. The test condition of accelerated degradation test is determined. The modified accelerating test reduces the test time in design phase by using the suggested accelerating factor.

A technology State of Accelerating Degradation and Life Estimation on the Traction Motor for Railway Rolling Stock (철도차량 견인전동기의 가속열화수명평가 기술현황)

  • Wang, Jong-Bae;Kim, Ki-Jun;Choi, Young-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.25-28
    • /
    • 2000
  • In this paper, the technology for accelerating degradation & life estimation on the traction motor was introduced with the stator form-winding sample coils of the 200 Class insulation system The accelerative degradation was performed in 10 cycles, which were composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of $20{\sim}160^{\circ}C$. Relationship between degradation conditions and diagnosis results were analyzed to find an dominative degradation factor at the end-life point

  • PDF

Estimation of Elevator Wire Life Using Accelerated Degradation Model (가속 열화 모형을 이용한 엘리베이터 와이어 수명 예측)

  • Kim, Sang Boo;Kim, Seung Ho
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.3
    • /
    • pp.409-420
    • /
    • 2015
  • Purpose: This study is to estimate the life of elevator wire rope by using the accelerated degradation test with two accelerating variables of applied load and corrosion. Methods: Linear regression method is used to find the pseudo life of elevator wire rope at each combination of accelerating variables and the median life of elevator wire rope at use condition is estimated under the assumption that the life of elevator wire rope follows lognormal distribution. Results: The particular case study demonstrated that the results of the elevator wire life estimation by using the proposed method can provide the better solutions than existing methods. Conclusion: It can be economical to use accelerated degradation model for estimating the life of elevator wire rope.

A Study on the Complex Accelerating Degradation and Condition Diagnosis of Traction Motor for Electric Railway (전기철도용 견인전동기의 복합가속열화 상태진단에 관한 연구)

  • 왕종배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.1
    • /
    • pp.93-101
    • /
    • 2002
  • In this study, the stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the C-Class(200$\^{C}$ ) insulation system of traction motors. The complex accelerative degradation was periodically performed during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, the condition diagnosis test such as insulation resistance '||'&'||' polarization index, capacitance '||'&'||' dielectric loss and partial discharge properties were investigated in the temperature range of 20 ∼ 160$\^{C}$. Relationship among condition diagnosis tests was analyzed to find a dominative degradation factor and an insulation state at end-life point.

Fault Prediction & Reliability Estimation of the Traction Motor by the Complex Accelerating Degradation and Condition Diagnosis (견인전동기의 복합가속열화 상태진단에 의한 고장예측 및 신뢰성 평가)

  • 왕종배;김명룡
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.763-766
    • /
    • 2000
  • In this paper, stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the 200 Class insulation system of traction motors. The complex accelerative degradation was performed by periods during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of 20∼160$^{\circ}C$. Relationship among condition diagnosis test was analyzed to find an dominative degradation factor and an insulation state at end-life point.

  • PDF

The Degradation Characteristics of Phosphor Layers by Environmental Temperature and Plasma Discharge in AC-PDPs (분위기 온도와 플라즈마 방전에 의한 AC-PDP의 형광막 열화 특성)

  • Kim, Hyun;Jang, Sang-Hun;Tae, Heung-Sik;Choi, Kyung-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.9
    • /
    • pp.443-448
    • /
    • 2002
  • The degradation characteristics of R, G, B phosphor layers in AC-PDP, which is due to the discharge of plasma, are still unknown. For the successful commercialization of AC-PDP, the degradation of phosphor layers, caused by the plasma discharge must be investigated and improved. In this paper, the degradation properties of phosphor layers in AC-$PDP_S$ are investigated. It takes long time to investigate the degradation in real condition, so that the device for accelerating the degradation is devised. To prove the performance of the device, the visible emission characteristics of phosphor layers and discharge with the environmental temperature are examined. As a result, it is shown that the phosphor layers are easily degraded when the discharge is sustained under high environmental temperature condition. After accelerating the degradation of blue Phosphor layer((Ba,Eu)Mg$AI_10$$O_17$) for 48 hours, its luminance decreases about 38 % and the corresponding color purity deteriorates severely.

Condition Diagnosis by the Complex Accelerating Degradation for Fault Prediction & Estimation of Reliability on the Traction Motor - Dielectric loss and PD Properties according to High Voltage (견인전동기의 고강예측 및 신뢰성 평가를 위한 복합가속열화 상태진단 - 고전압 인가에 따른 유전손실 및 부분방전 특성 연구)

  • Wang, Jong-Bae;Baek, Jong-Hyen;Byun, Yoon-Sub;Park, Hyun-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1371-1373
    • /
    • 2000
  • In this paper, the complex accelerating degradation of traction motor driven with VVVF controlled inverter were performed on the form coil samples with the 200 Class insulation system. in order to evaluate the reliability and the long-term life. After aging, the dielectric and PD properties were investigated on the 10 cycles aging sample in the range of $20{\sim}160[^{\circ}C]$ and AC $250{\sim}2250[V]$ to diagnosis the condition of end-life and find the dominative factors of degradation.

  • PDF

Degradation of Coatings under Atmospheric Tropical Conditions

  • To, Thi Xuan Hang;Pham, Gia Vu;Vu, Ke Oanh;Trinh, Anh Truc;Kodama, Toshiaki;Tanabe, Hiroyuki;Taki, Tohru;Nagai, Masanori
    • Corrosion Science and Technology
    • /
    • v.2 no.5
    • /
    • pp.207-211
    • /
    • 2003
  • The weather resistance of five coatings systems based on alkyd, chlorinated rubber, epoxy, polyurethane and fluoropolymer were studied by natural exposure test and accelerated test. The coatings were exposed at Hanoi station with urban industry atmosphere and at Baichay station with marine atmosphere. The degradation of coatings was evaluated by gloss measurement and surface analysis by scanning electronic microscopy. The results obtained show that among coatings tested the gloss of polyurethane and fluoropolymer coatings remained highly and those of alkyd, chlorinated rubber and epoxy coatings were very low after two years of atmospheric exposure. Under accelerating conditions the gloss of fluoropolymer coatings remained highly after 80 cycles of testing. By comparison with accelerating test in UV-condensation chamber the conditions at atmospheric stations are more aggressive.

Accelerated Life Test of Industrial Cleaner Motor (산업용 청소기 모터의 가속수명시험)

  • Eom, Hak-Yong;Lee, Gi-Chun;Chang, Mu-Seong;Park, Jong-Won;Lee, Yong-Bum
    • Journal of Applied Reliability
    • /
    • v.18 no.3
    • /
    • pp.193-200
    • /
    • 2018
  • Purpose: In this study, the life of the motor is investigated by performing the accelerated life test with the brush wear of the industrial cleaner motor as the main failure mode. Methods: The accelerating stress factor of the accelerated life test is a voltage, which can increase the number of revolutions of the motor to accelerate the brush wear due to the friction between the brush and the commutator. Also, the accelerating stress level was determined after determining the maximum allowable level of the voltage through the preliminary test. Results: The motor failure time at each accelerating stress level was predicted by regression analysis with brush wear length as performance degradation data. The main failure mode, which is brush wear, of the motor was reproduced by this test. The shape parameter of the Weibull distribution was confirmed to be the same statistically at all accelerating stress levels by the likelihood ratio test. Conclusion: The life of the motor was investigated by performing the accelerated life test with the brush wear of the industrial cleaner motor as the main failure mode. Through the accelerating test method of the cleaner motor, various life expectancy and life expectancy of the acceleration factor are predicted.

Degradation of Ascorbic acid in Limited Dissolved Oxygen Environment (제한된 산소 존재중의 Ascorbin 산의 분해에 대하여)

  • Rhee, Sook-Hee
    • Journal of Nutrition and Health
    • /
    • v.9 no.4
    • /
    • pp.54-58
    • /
    • 1976
  • Deterioration of ascorbic acid content is the important factor in the food quality. The degradation of ascorbic acid undergoes as a first-order of reaction in the presence of excess oxygen content. However, under the limited oxygen content, ascorbic acid decomposes as a psudo-first order of reaction. The ascorbic acid, in this study, under the limited dissolved oxygen content in the presesce of iron(III) and copper(II) decomposed as first-order reaction with a little influence in rate constant and the light was an accelerating factor on the ascorbic acid degradation.

  • PDF