• Title/Summary/Keyword: Accelerated Aging Test

Search Result 229, Processing Time 0.029 seconds

Study on Accelerated Life-time Test of O-ring Rubber by Thermal Stress (열 스트레스에 의한 고무 오링의 가속수명시험에 관한 연구)

  • Shin, Young-Ju;Chung, Yu-Kyung;Choi, Kil-Yeong;Shin, Sei-Moon
    • Journal of Applied Reliability
    • /
    • v.7 no.1
    • /
    • pp.31-43
    • /
    • 2007
  • The function of O-ring seals is to prevent leakage during the service life of the components in which they are installed. The life prediction of O-ring is very important at various industry fields. Generally, to evaluated the long-term performance of O-ring in severe environments has applied a life prediction technique based on accelerated life test (ALT). In this work, Accelerated thermal aging test(l20, 130, 140, $150^{\circ}C$) of O-ring was applied for life prediction of O-ring. The property changes after thermal aging test was measured using TGA, DSC, FT - IR, Video Microscope and SEM. Shape parameter and life prediction were obtained using MINITAB program.

  • PDF

Analysis on the Electric Characteristics of Natural Ester after Accelerated Thermal Aging (식물성 절연유의 열 열화에 따른 전기적 특성 연구)

  • Shim, Meoung-Seop;An, Jung-Sik;Choi, Sun-Ho;Jung, Joong-Il;Kim, Nam-Ryul;Huh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.81-81
    • /
    • 2010
  • This paper presents results of experimental investigations on natural ester regarding the breakdown strength. Aging of insulating material in a pole transformer has been studied by performing accelerated thermal aging test. Sealed aging test vessels containing copper, laminated core, Krapt paper and insulating oil(Natural oil and Mineral oil) were aged at $140^{\circ}C$ for 30days. Compared to the conventional transformer oil, electric property of the natural ester fluid is excellent.

  • PDF

Accelerated Aging Characteristics of a Double Base Propellant (복기추진제의 가속 노화 특성 연구)

  • Go, Cheongah;Park, Youngchul;Seo, Taeseok;Moon, Youngtaek;Kim, Junhyung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.4
    • /
    • pp.61-69
    • /
    • 2019
  • Accelerated aging test for the double base propellant was carried out at three different temperatures (60, 70, and $75^{\circ}C$) for over a year. To evaluate the aging characteristics of the double base propellant, the stabilizer contents and thermal decomposition kinetics were analyzed by using high performance liquid chromatography (HPLC) and AKTS-Thermokinetics software. As a result, stabilizer contents in the double base propellant gradually decreased according to the aging temperature and aging duration. The consumption rate of 2-NDPA in the accelerated aged propellants showed that it was two times faster at $75^{\circ}C$ in compared with ther rate at $70^{\circ}C$. These experimental values were simulated by the SB kinetic model, and it was shown that the two-step model with constant reaction orders n1=1 and n2=0 best describes the process of the stabilizer depletion for the double base propellant.

Studies on the Physical Properties of Base Paper for the Manufacture of Mulching Mat for Afforestation Seedling (조림묘목 mulching mat 제조용 base paper의 물리적 특성 연구)

  • Kim, Hyoung-Jin;Oh, Dong-Geun;Yoo, Yeong-Jeong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.41 no.1
    • /
    • pp.37-43
    • /
    • 2009
  • In this study, the physical properties of base paper for the manufacture of mulching mat for afforestation seedling were investigated. The base paper for mulching mat was prepared by stock conditions of PAE and AKD addition into the screened slurry of KOCC for the strengthening effects of wet tensile and burst strength. The optimum additions of PAE and AKD were considered at 2% and 0.5%, respectively. The accelerated aging by ISO 5630-1 and wet heat aging method under hot water for 2 kinds of commercial mulching and wet strength paper were compared with the base paper prepared for mulching mat manufacture. The accelerated aging test for the base paper prepared for mulching mat manufacture resulted in the same tendency of physical properties as two kinds of commercial products. However, the results of wet heat aging test under hot water indicated that the physical strength for base paper prepared was much higher than others. In addition, the opacity behavior for base paper prepared was enough effects to obstruct weeds growth by isolating transmission of sunlight.

Study on the Experimental Aging Estimation Technique for HTPB based Solid Propellant Considering Post Curing Effect (후경화를 고려한 HTPB 고체 추진제의 실험적 노화평가 기법 연구)

  • Jung, Gyoo Dong;Park, Jae Beom;Kim, Shinhoe
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.3
    • /
    • pp.51-57
    • /
    • 2019
  • Post curing effects are estimated by specimen tests. Propellant specimen accelerated aging tests are performed when post curing is estimated to be complete and the coefficients of Arrhenius aging equations are acquired. Simulated motors with cylindrical grain are designed and fabricated to confirm the application. Accelerated aging tests are conducted, and aged properties are measured and estimated for the inner bore, center and bond parts of the grain. The measured aging ratios of the modulus are compared with the ones predicted by the equations. As the results, the accelerated aging equations predict well the propellant aging trends; however, some differences are observed at the bond part. Therefore, the specimen extraction part must be carefully chosen to suit the test purpose when a rocket motor grain is used for the aging test.

Multi-phase Accelerating Test Method of Thermal Aging Considering Heat Generation of Electric Equipment (전기기기의 발열을 고려한 다단계 가속열노화 방법)

  • Lim, Byung-Ju;Park, Chang-Dae;Chung, Kyung-Yul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.5
    • /
    • pp.18-23
    • /
    • 2013
  • Thermal aging test is performed to qualify the life time of equipment in thermally aged condition. Due to long life time more than 10 years like as in power plant, the equipment is subjected to the accelerated thermal aging condition which is able to shorten the long aging test period by increasing aging temperature. Normally, conservatism of thermal aging test causes to impose unbalanced and excessive thermal load on components of the equipment, and deformation and damage problems of the components. Additionally, temperature rise of each component through heat generation of the electric equipment leads to long-term problem of the test period. Multi-phase accelerating aging test is to perform thermal aging test in multiple aging conditions after dividing into groups with various components of equipment. The groups might be classified considering various factors such as activation energy, temperature rise, glass transition temperature and melting temperature. In this study, we verify that the multi-phase accelerating aging test method can reduce and equalize the thermal over load of the components and shorten aging test time.

Accelerated Heat Aging Test for Predicting Useful Lifetime of Elastomeric Rearing (가속 열 노화시험에 의한 탄성받침용 합성고무의 수명 예측에 관한 연구)

  • Park, K.H.;Park, J.H.;Lee, H.H.;Kwon, Y.I.
    • Journal of Applied Reliability
    • /
    • v.4 no.2
    • /
    • pp.73-90
    • /
    • 2004
  • We performed the heat aging test to predict the useful lifetime of Elastomeric Bearing Chloroprene Rubber (CR) used for supporting bridge. During the test, we measured elongation that are influenced by temperature and aging time. The failure of a test piece is defined as the point at which the elongation reaches to 75% of the initial value. This failure criterion is based on KS F 4420: 1998 (Elastomeric Bearing for bridge). Through the accelerated heat aging test, we found that the Arrhenius relationship and the Weibull lifetime distribution are appropriate as the life-temperature relationship and lifetime distribution of the CR, respectively. Using the Arrhenius -Weibull model, the parameters of the model are estimated and the lifetime of the CR at use condition is predicted.

  • PDF

A Study of Life about Naturally Aged Nitrocellulose by Storage (자연 노화된 니트로셀룰로오스의 수명에 관한 연구)

  • Kim, Dong-seong;Jin, Hong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.595-601
    • /
    • 2020
  • During the safety inspection of nitrocellulose-made explosive containers stored for more than 10 years, cracks were found in the containers. Therefore, a failure cause analysis test was performed. First, the cause of failure through the failure tree analysis was conducted to select the factors that influenced failure. The changes in the properties of the container caused by the acceleration of the reaction were found to be the cause of the failure by confirming the influence on the environment and internal/external factors that may occur during storage. To confirm this, environmental tests, such as thermal shock test and vacuum thermal stability test, were performed using a naturally aged container to analyze the cause of failure, and an accelerated aging test was performed to reproduce the failure. Through this, the chemical reaction was accelerated by heat and charge, as in the result of the fault tree analysis, and it was confirmed that the physical properties of the container were changed. In addition, the service life of the container was estimated using the Arrhenius model for the storage life due to thermal aging.

Performance Evaluation of Polymer Insulator using Tracking Wheel and Multi-Aging Test (트래킹 휠과 복합열화시험에 의한 폴리머 애자의 성능 평가)

  • 조한구;안명상;한세원;허종철;이운용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.119-122
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymer insulators are a relatively new technology, but their expected life is still unknown. Therefore these estimating technique are very important. Their life time is related to weathering and operating condition. Multi-aging test is requested because aging factor is occurred by multi-aging than unique aging. The aging test about polymer insulators have mainly carried out by IEC 61109. This paper presents multi-stress chamber experiments and tracking wheel test to examine the tracking and erosion performance of polymer insulator for transmission. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. We have investigated IEC 61109 Annex C (5000h aging test) and CEA tracking wheel test as test methods of artificial accelerated aging. The aging degree of polymer insulator is estimated by leakage current, measurement of hydrophobicity degree, damage conditions of insulator surface, withstand voltage test etc.

  • PDF

Changes in Insulation Performance of Organic Insulating Materials for Building Construction by Accelerated Durability Test Conditions (가속내구성 조건에 따른 건축용 유기계 단열재의 단열성능 변화)

  • Lim, Soon-Hyun;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.595-601
    • /
    • 2016
  • The insulation performance of the insulation currently used in building structures is reflected only during design based on initial performance and the reduction in heat insulation performance due to the degradation of long-term durability is not reflected. This study reviewed the degradation of heat insulation performance due to the durability degradation of insulating materials through the accelerated durability test. The study findings showed that the foamed polystyrene insulation bead method did not show performance degradation due to aging in the standard environmental condition and laboratory accelerated test condition but the performance is degraded in the freeze-thaw test condition. On the other hand, in the case of the extrusion method, the degradation of the heat insulation performance was less in the freeze-thaw test condition, but the rapid performance degradation was caused by the release of the internal gas at the beginning of aging. In addition, the hard polyurethane foam insulation showed better initial insulation performance than other insulation materials, but the performance was found to be degraded somewhat under laboratory accelerated test conditions and freeze-thaw test conditions.