• 제목/요약/키워드: Abutment teeth

검색결과 181건 처리시간 0.023초

Clinical and radiographic evaluations of implants as surveyed crowns for Class I removable partial dentures: A retrospective study

  • Yoo, Soo-Yeon;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권2호
    • /
    • pp.108-121
    • /
    • 2022
  • PURPOSE. The purpose of this study was to evaluate survival rates and marginal bone loss (MBL) of implants in IC-RPDs. MATERIALS AND METHODS. Seventy implants were placed and used as surveyed crowns in 30 RPDs. The survival rates and MBL around implants based on multiple variables, e.g., position, sex, age, opposing dentitions, splinting, type of used retainer, and first year bone loss, were analyzed. Patient reported outcome measures (PROMs) regarding functional/esthetic improvement after IC-RPD treatment, and complications were also inspected. RESULTS. The 100% implant survival rates were observed, and 60 of those implants showed MBL levels less than 1.5 mm. No significant differences in MBL of implants were observed between implant positions (maxilla vs. mandible; P = .341) and type of used retainers (P = .630). The implant MBL of greater than 0.5 mm at 1 year showed significantly higher MBL after that (P < .001). Splinted implant surveyed crowns showed lower MBL in the maxilla (splinted vs. non-splinted; P = .037). There were significant esthetic/functional improvements observed after treatment, but there were no significant differences in esthetic results based on implant position (maxilla vs. mandible). Implants in mandible showed significantly greater improvement in function than implants in the maxilla (P = .002). Prosthetic complication of IC-RPD was not observed frequently. However, 2 abutment teeth among 60 were failed. The bone loss of abutment teeth was lower than MBL of implants in IC-RPDs (P = .001). CONCLUSION. Class I RPD connected to residual teeth and strategically positioned implants as surveyed crowns can be a viable treatment modality.

A simple technique for impression taking of teeth and functionally generated paths

  • Yamamoto, Takatsugu;Sato, Yohei;Watanabe, Hidehiko;Punj, Amit;Abe, Minoru;Momoi, Yasuko;Ohkubo, Chikahiro
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.9.1-9.6
    • /
    • 2018
  • The objective of this case report is to introduce a simple technique for simultaneously taking a closed-mouth impression and functionally generated path (FGP) for a full coverage crown restoration. A monolithic zirconia crown was the restoration of choice. An alginate impression of the abutment tooth was taken to fabricate a custom-made closed-mouth impression tray covering the abutment tooth and the adjacent teeth. The tray had an FGP table and an abutment tray in cameo and intaglio surfaces, respectively. The impression was taken with silicone impression material after adjusting the abutment tray and inscribing the FGP using self-curing acrylic resins. Plaster casts were made from the impression, and a zirconia crown was fabricated. The crown was cemented to the abutment tooth with minimal adjustments. This simple technique resulted in a well-fitting crown that accounted for mandibular movements. Using the custom closed-mouth impression tray incorporating an FGP table simultaneously aids in fabricating an accurately fitting restoration that incorporates harmonious mandibular movements using a single impression capture.

간접유치장치 설계변화에 따른 하악유리단 국소의치의 광탄성 응력분석 (A PHOTOELASTIC STRESS ANALYSIS IN MANDIBULAR DISTAL - EXTENSION REMOVABLE PARTIAL DENTURES WITH VARIOUSLY DESIGNEO INDIRECT RETAINERS)

  • 강승종;계기성
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.183-197
    • /
    • 1990
  • The purpose of this study was to analyse the magnitude and distribution of stresses using a Photoelastic model from and distal - extension removable partial dentures With four designed indirect retainers. The designs of the indirect retainers were as follows : Design No. 1 : Aker's clasp on 1st bicuspid with no indirect retainer. Design No. 2 : Aker's clasp on 1st bicuspid with indirect retainer on canine. Design No. 3 : Extension of the reciprocal arm of Aker's clasp toward incisal rest on canine. Design No. 4 : Connection with the indirect retainer as in No. 2 and extension of reciprocal arm of Aker' s clasp. A photoelastic model was made of the epoxy resin(PL - 1) and hardner(PLH - 1) and coated with plastic cement -1(PC -1) at the lingual surface of the epoxy model and set with chrome - cobalt partial dentures. A unilateral vertical load of 10kg to the right 1st molar and a vertical load of 10kg to the middle portion of the metal bar crossing both the 1st molars of the right and left, were applied. With the use of specially designed jig, fixture; loading device and the reflective circular polariscope, we obtained the following results : 1. When the unilateral vertical load and the vertical load of the middle portion of the metal bar were applied, design No. 2, 3 and 4 exhibited the higher stress concentration at the root apices and their surrounding tissues of the primary and secondary abutment teeth. 2. When the unilateral vertical load applied to design No. 2,3 and 4 the root apices of the primary and secondary abutment teeth and their surrounding tissues and the nonloaded side of edentulous area exhibited and even stress distribution. 3. When the vertical load was applied, the stress concentration fringe in the primary and secondary abutment teeth was in the order of No. 1,4,2 and 3. 4. No.1 and 4 exhibited the higher distrorted stress concentration at the primary teeth and the edentulous area in the nonloaded side. 5. No.2 design reduced the stresses at the apices of the alveoli of the primary abutment teeth bilaterally as well as on the crest of the residual ridge on the nonloaded side. 6. No. 2 design exhibited the most favorable stress distribution.

  • PDF

캐드캠 기능을 이용한 전치부 심미 수복 및 전치부 임플란트에서 지르코니아 링크 지대주(Hybrid abutment)의 사용 (The use of zirconia hybrid abutment for the anterior esthetic restoration and anterior implant utilizing CAD/CAM technology)

  • 김종엽
    • 대한심미치과학회지
    • /
    • 제22권1호
    • /
    • pp.9-21
    • /
    • 2013
  • 심미의 기준은 시대와 문화 그리고 개개인의 주관적인 관점에 따라 각기 다를 수 있다. 하지만 심미적인 부위를 수복하는 치과의사로서 일반적으로 따라야 할 원칙과 기준들이 있으며 수복물의 형태와 주변치아와의 조화 등을 위해 캐드캠의 몇몇 기능들은 아주 유용한 것으로 보이며, 전통적인 작업 방식에 비해 효율성도 높은 것으로 보인다. 또한 전치부 임플란트에서 치은이 얇은 경우 기계적인 문제를 줄이면서도 지르코니아 등의 도재를 사용하기 위한 한 방법인 링크 지대주에 대해 함께 알아보려 한다.

Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study

  • Kim, Sung-Jun;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.388-394
    • /
    • 2018
  • PURPOSE. To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS. Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at $10N{\cdot}cm$, simulating hand tightening, and then at the manufacturers' recommended torque ($30N{\cdot}cm$) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS. Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION. Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening.

골내 임프란트를 이용한 고정성 국소의치 하에서 변위 및 응력에 관한 유한요소법적 분석 (FINITE ELEMENT ANALYSIS OF STRESSES AND DEFLECTIONS INDUCED BY FIXED PARTIAL DENTURE USING ENDOSTEAL IMPLANT)

  • 최수호;정재헌
    • 대한치과보철학회지
    • /
    • 제29권1호
    • /
    • pp.233-248
    • /
    • 1991
  • The purpose of this study was to qunatatively analyze the stress patterns induced in the abutment, superstructure, supporting bone and to determine the deflection of abutment and superstructure by appling occlusal force to natural teeth supported fixed prostheses and implant-supported fixed prostheses. The analysis has been conducted by using the two dimensional finite element method. The implant and natural tooth-supported bridge has a first molar pontic supported by mandibular second bicuspid and implant posterior retainer, which were rigidly(Model A) or flexible(Model B). The natural teeth-supported bridge has a first molar pontic supported by mandibular second bicuspid and second molar, which were rigidly splinted together(Model C). 63.5kg(Load P1) of localized load on central fossa of first molar pontic and 24kg(Load P2) of distributed load on each occlusal surface were applied respectively. 1. The coronal portion of premolar pontic and posterior abutment in fixed partial denture deflected inferiorly in order of Model B, Model C and Model A under Load P1 and Load P2. 2. Mesial displacement of the coronal portion of premolar showed in Model A, Model B and Model C under Load P1, but mesial displacement of that in Model B and distal displacement of that in Model A and Model C showed under Load P2. 3. Mesial displacement of the coronal portion of the pontic and distal displacement of the coronal portion of posterior abutment showed in Model A, Model B and Model C under Load P1 and Load P2. Displacement in the case of Model B was greater than that of Model A and Model C. 4. In the case Model A under Load P1 and Load P2, high stress apically was concentrated in the mesiocervical portion of the posterior abutment than in the disto-cervical portion of the premolar. 5. In the case of Model B under Load P1 and Load P2 high stress was concentrated in the case of the premolar than in that of posterior abutment and high stress especially was concentrated in the connected portion of pontic and posterior abutment. 6. In the case of Model C under Load P1 and Load P2, high stress was concentrated in the distal area of the cornal portion of premolar and the mesial area of the coronal portion of posterior abutment, and stress pattern was anteroposterially symmetric around the pontic. 7. Load P1 and Load P2 compared, stress magnitude was different but stress pattern was similar in Model A, Model B and Model C. 8. Under Load P1 and P2, stress magnitude in the mesial distal portion and the portion of root apex of the posterior abutment was in order of Model B, Model A and Model C.

  • PDF

지대주 혹은 지대주 나사 파절이 발생한 임플란트 보철물에서 효과적인 수리 방법 (Repairment of abutment and abutment screw fracture in implant prosthesis: A case report)

  • 김제훈;유진주;김만용;윤준호
    • 대한치과보철학회지
    • /
    • 제57권1호
    • /
    • pp.37-41
    • /
    • 2019
  • 치과 임플란트는 상실된 치아의 수복에 효과적이고 예측 가능한 치료 방법이다. 하지만 임플란트 사용이 증가함에 따라 합병증도 증가하고 있다. 이 중 기계적 합병증은 발생 빈도가 높을 뿐 아니라 임플란트의 수명이 길어질수록 더 많이 발생하므로 이에 대한 대책이 필요하다. 이에 임플란트의 가장 흔한 기계적 합병증인 지대주 파절과 지대주 나사 파절의 증례에서 파손된 부위만 재제작하여 파손되지 않은 구성요소를 최대한 보존할 수 있는 방법을 소개하고자 한다.

하악 4전치 상실 시 임플란트 수복 (Mandibular 4 incisors implant restoration)

  • 박종현
    • 대한심미치과학회지
    • /
    • 제31권2호
    • /
    • pp.56-63
    • /
    • 2022
  • 하악 4전치 수복은 치아가 작고 공간도 좁아서 지대주 선택에 어려움이 따른다. 치주적으로 좋지 못한 상황에서 치아를 발거하는 경우가 대부분이고, 이러한 경우 치간공극을 크게 열어주는 것이 구강위생 관리 측면에서 유리하다1. 커스텀 지대주로 아무리 작은 직경으로 포스트 부위를 만든다 해도, 스크류가 들어가는 공간 때문에 작은 직경으로 지대주의 포스트 부위를 만드는 것에는 한계가 있다. One body implant2의 경우, post 부위를 넓은 정면으로 설정하는 것 보다는, 보다 d 얇은 측면(90도 회전면)으로 설정하는 것이 치간공극 형성을 위해 유리하다. Internal bone level implant 활용 시 two piece abutment를 활용하는 것 보다, one-piece abutment를 활용한다면 더 효과적으로 치간공극을 위한 공간을 확보할 수 있다.

Konus telescope에 의한 유리단 결손 수복에 관한 임상적 연구(I) (CASE REPORTS ON THE REMOVABLE PARTIAL DENTURES WITH DONUS TELESCOPE)

  • 방몽숙
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.67-77
    • /
    • 1997
  • The purpose of this study was to evaluate a cases which was treated with konus telescope on the patients in bilaterally edentulous mandible. Author made konus telescope for two patients and then X-ray and clinical examination were used for evaluation of the function and change in supporting structure of the abutment teeth during the 60months. Patient complained of difficulties in removal of denture at the beginning but they got used to it soon. X-ray showed that there were no changes in supporting structure of the abutment teeth after 60 months. It was effective in promotion of ridge soreness and also reducing the need of relining. This study suggest that konus telescope was effective for the treatment of bilaterally edentulous situations.

  • PDF

가철성 의치의 유지관리 (Maintenance care for removable denture)

  • 조리라
    • 대한치과의사협회지
    • /
    • 제54권12호
    • /
    • pp.996-1023
    • /
    • 2016
  • There are many kinds of maintenance care services for removable denture patient. Adjustment of the denture base and occlusion should be performed regularly not only for pain relief but also for maintaining the denture function. Direct and indirect relining are needed frequently in specific cases including mandibular distal extension case or non-symmetric residual teeth situation. Surface treatments for metal and resin are essential in the relining procedure. Clinical process for the denture repair is similar to indirect relining which needs inter-occlusal registration. Especially, the peridontal maintenance care and caries prevention are most important way to preserve the abutment teeth in partial edentulism. Moreover, the caring method for the denture and the tissue should be instructed to the denture patient.

  • PDF