Fracture Behavior for Carbon Fiber Reinforced Plastic by Immersion (흡수에 따른 탄소섬유 강화수지의 파괴거동)

  • Kim, O. G.;Nam, K. W.;Ahn, B. H.
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.4
    • /
    • pp.402-410
    • /
    • 1996
  • Recently carbon fiber reinforced plastic(CFRP) has been used structural materials in corrosive environment such as for water, chemical tank and chemical pipes. However, mechanical properties of such materials may change when CFRP are exposed to corrosive environment for long periods of time. Therefore, it is important to understand the effect of moisture absorption on mechanical properties of the CFRP. In this study, degradation behavior of immersed carbon fiber/epoxy resin composite material was investigated using acoustic emission(AE) technique. Fracture toughness test are performed on the compact tension(CT) test specimens that are pilled by two types of laminates $[0^{\circ}_2$/$90^{\circ}_2]_3s$ and $[0^{\circ}_2$/$90^{\circ}_2]_6s$During the fracture toughness test, AE test was carried out to monitor the damage of CFRP by moisture absorption. In spite of the change of moisture absorption rate, the fracture toughness of CFRP was not change. As immersion time increased, AE event count numbers decreased in low amplitude range of AE for amplitude distribution histogram. The event in low amplitude range was known to be generated by debonding of matrix-fiber interface. Therefore, decrease of AE event count numbers in low amplitude range represents that debonding of matrix-fiber interface which was probably generated by moisture absorption.

  • PDF

A Proposal on Evaluation Method of Neutron Absorption Performance to Substitute Conventional Neutron Attenuation Test

  • Kim, Jae Hyun;Kim, Song Hyun;Shin, Chang Ho;Choe, Jung Hun;Cho, In-Hak;Park, Hwan Seo;Park, Hyun Seo;Kim, Jung Ho;Kim, Yoon Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.384-388
    • /
    • 2016
  • Background: For a verification of newly-developed neutron absorbers, one of guidelines on the qualification and acceptance of neutron absorbers is the neutron attenuation test. However, this approach can cause a problem for the qualifications that it cannot distinguish how the neutron attenuates from materials. Materials and Methods: In this study, an estimation method of neutron absorption performances for materials is proposed to detect both direct penetration and back-scattering neutrons. For the verification of the proposed method, MCNP simulations with the experimental system designed in this study were pursued using the polyethylene, iron, normal glass and the vitrified form. Results and Discussion: The results show that it can easily test neutron absorption ability using single absorber model. Also, from simulation results of single absorber and double absorbers model, it is verified that the proposed method can evaluate not only the direct thermal neutrons passing through materials, but also the scattered neutrons reflected to the materials. Therefore, the neutron absorption performances can be accurately estimated using the proposed method comparing with the conventional neutron attenuation test. Conclusion: It is expected that the proposed method can contribute to increase the reliability of the performance of neutron absorbers.

Air Density Measurement in a Narrow Test Section Using a Laser Absorption Spectroscopy (레이저 흡수 분광법을 사용한 좁은 시험 구간 내 공기 밀도 측정)

  • Shim, Hanseul;Jung, Sion;Kim, Gyeongrok;Park, Gisu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.11
    • /
    • pp.893-900
    • /
    • 2021
  • In this study, air density in a narrow test section is measured using a laser absorption spectroscopy system that detects oxygen absorption lines. An absorption line pair at 13156.28 and 13156.62 cm-1 are detected. A gas chamber with a height of 40 mm is used as a narrow test section. A triangular spiral-shaped laser path is applied in the gas chamber to amplify absorption strength by extending laser beam path length. A well-known logarithm amplifier and a secondary amplifier are used to electrically amplify absorption signal. An AC-coupling is applied after the logarithm amplifier for signal saturation prevention and noise suppression. Procedure of calculating spectral absorbance from output signal is introduced considering the logarithm amplifier circuit configuration. Air density is determined by fitting the theoretically calculated spectral absorbance to the measured spectral absorbance. Test conditions with room temperature and a pressure range of 10~100 kPa are made in a gas chamber using a Bourdon pressure gauge. It is confirmed that air density in a narrow test section can be measured within a 16 % error through absorption signal amplification using a triangular spiral-shaped beam path and a logarithm amplifier.

Experimental Investigation of Factors Influencing Chair Absorption Characteristics (의자 흡음특성에 영향을 미치는 인자에 관한 실험적 연구)

  • Choi, Young-Ji;Koo, JaeOh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.4
    • /
    • pp.282-287
    • /
    • 2015
  • This paper examines the combinations of factors influencing the absorption characteristics of theatre chairs. One-tenth scale model chairs and listeners that closely approximated the absorption characteristics of full scale theatre chairs were used to measure the interactive effects of the test variables on the chairs absorption characteristics. The test variables were the type of chairs, the row spacing, as well as the presence of people and carpet. The variations of absorption increments with varied row spacing tended to be smallest when the chairs were less absorptive, i.e. with less carpet or occupants. The incremental effects of adding occupants or carpet averaged over three row spacings varied over frequency.

Durability Characteristics of Glass Fiber Reinforced Polymer Composite Clapping Plates for Application of Rubber Dam (고무댐에 적용하기 위한 유리섬유보강 복합재료 클랩핑 플레이트의 내구 특성)

  • Lee, Jeong-Woo;Park, Chan-Gi;Kim, Jong-Ok;Lee, Seung-Kee;Kim, Pil-Sik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.5
    • /
    • pp.17-23
    • /
    • 2011
  • Steel clapping plate is used to connecting rubber body in rubber dam. However, once the steel clapping plate corrodes, it may cause faults, such as the same problems experienced by typical reinforcing steel. This study evaluated the applicability of glass fiber reinforced polymer composite(GFRP) clapping plate as a substitute for steel clapping plate. Absorption and load test were conducted to evaluate the decrease in durability of GFRP clapping plate exposed to deterioration environments. In the durability test results, the absorption rate of GFRP clapping plate was appeared as 0.6~1.0% in 50 day of immersion time. Also, the fracture load decreased with accelerated degradation environment exposure. Moreover, the absorption rate in GFRP clapping plate increased as degradation progressed, reducing the fracture load.

Investigation on the Effects of Air-Damping on the Sound Absorption Coefficients Measured in the Tube (관내법 시험시 Air-Damping이 흡음률에 미치는 영향 고찰)

  • 정완섭;서재갑;황재호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.443-446
    • /
    • 1997
  • This paper raises issues in testing the absorption coefficients of sound-absorptive samples in the standing wave tube according to the Korean standard of KS F 2814. The code does not consider any effect of air-damping during test. This limitation has been shown to yield much variation of sound absorption coefficients for recent sample tests whose coefficients are less than 10 %. An improved method of calculating the sound absorption coefficients is proposed in this work and its effectiveness in real test is also illustrated. Finally, the guide line for the modification of our national standard code KS F 2814 is suggested for the future.

  • PDF

The characteristics of bending collapse of aluminum/GFRP hybrid tube (알루미늄/GFRP 혼성튜브의 굽힘붕괴 특성)

  • 송민철;이정주
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.84-87
    • /
    • 2000
  • Square tubes used for vehicle structure components have an important role on keeping its stiffness and preserving occupant safety in vehicle collision and rollover in which it experience axial collapse, bending collapse or both. Bending collapse, which absorbs kinetic energy of the impact and retains a survival space for the occupant, is a dominant failure mode in oblique collision and rollover. Thus, in this paper, the bending collapse characteristics such as the maximum bending moment and energy absorption capacity of the square tube replaced by light-weight material were evaluated and presented. The bending test of cantilever tubes which were fabricated with aluminum, GFRP and aluminum/ GFRP hybrid by co-curing process was performed. Then the maximum bending moment and the energy absorption capacity from the moment-angle curve were evaluated. Based on the test results, it was found that aluminum/ GFRP hybrid tube can show better specific energy absorption capacity compared to the pure aluminum or GFRP tube and can convert unstable collapse mode which may occur in pure GFRP tube to stable collapse mode like a aluminum tube in which plastic hinge is developed.

  • PDF

Biological Monitoring on the Absorption of Antineoplastic Drugs in Nursing Personnel (항암제 취급간호사의 항암제 체내흡수에 관한 조사)

  • 김봉임
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.3
    • /
    • pp.520-530
    • /
    • 1997
  • Antineoplastic agents may exhibit effects not only in patients therapeutically exposed, but also in health workers who prepare and administer these drugs. This study was done to clarify whether nurses who handle anticancer drugs show signs of drug absorption. The experimental group was 14 nurses handling anticancer drugs at three medical wards of a hospital in J city ; the control group was 12 psychiatric nurses at the same hospital. The test materials were the nurses' 24hr urine specimens, which were concentrated by XAD-2 column chromatograpy. Tester strains were TA98(±S9mix), TA100(±S9 mix), TA1535(±S9 mix) and TA1537(±S9 mix) : the salmonella mammalian microsomal test (Ames test) was used for the urinary mutagenicity assay. The results are summarized as follow : 1. In qualitative analysis of the results, both experimental group and control group showed 15.4% urine toxicity. 2. The experimental group revealed significantly higher urinary mutagenicity both in the activation method test and non-activation method test of the tester strains TA98, TA100 and TA1535. In the case of TA1537, the two groups showed no difference in the non-activation method test, but the activation method revealed a difference. 3. In urinary mutagenicity of the experimental group by ward career, there was a significant difference between the group with more than 20 months experience and the group with less than 20 months on the tester strains TA98, TA100, and TA1537. No Significant difference was found between two groups by the tester strain TA1535.

  • PDF

Effect of Ginseng on the Intestinal Absorption of Ethanol (인삼 성분이 Ethanol의 장관내 흡수에 미치는 영향)

  • Huh, Keun;Choi, Chong-Won
    • YAKHAK HOEJI
    • /
    • v.27 no.2
    • /
    • pp.163-168
    • /
    • 1983
  • The effect of ginseng butanol fraction (total sponin) on the absorption rate of ethanol in rat intestine was examined. Ginseng butanol fraction showed inhibitory effect on the intestinal absorption of ethanol in situ as well as in vitro test. Ginseng butanol fraction markedly decreased the ethanol blood level, delayed onset time of ethanol effect and shortened sleeping time when it was adminstered orally together with ethanol. These results suggest that ginseng may alter the ethanol blood level by decreasing the intestinal absorption of ethanol.

  • PDF

A Study on the Systematic Mechanical Integrity Evaluation Methods of Water-Cooled Generator Stator Windings (수냉각 발전기 고정자의 기계적 건전성 평가방법)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Wook-Ryun;Lee, Doo-Young;Choi, Hong-Il;Yeon, Se-Heum
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3059-3066
    • /
    • 2008
  • It is reported that the life of generator stator windings is expected about 30 years and a leak and water absorption phenomena can be progressed by fatigue, vibration, and corrosion. The water-cooled generator stator windings which were operated over 15 years are over 20 units and the mechanical problems such as leak and water absorption were found in the generator stator windings. In this paper, the systematic mechanical integrity evaluation methods which are applied to the water-cooled generator stator windings within the country are introduced.