• 제목/요약/키워드: Absorption measurement

검색결과 783건 처리시간 0.022초

반도체레이져를 이용한 온도 및 농도의 계측 (Temperature and Concentration measurement using Semi-conductor diode laser)

  • 정대헌;노동순;지전유이
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.168-174
    • /
    • 2000
  • A diode laser sensor system based on absorption spectroscopy techniques has been developed to measure $CO_2$ concentration and temperature non-intrusively in high temperature combustion environments using a 2.0 ${\mu}m$ DFB(Distributed Feedback) laser. Two optics was fabricated in pig-tail fashion and all optical components were implemented in a single box. The evolution of measurement sensitivity was done using test cell by changing sweep frequency and $CO_2$ concentration. Gas temperature was determined from the ratio of integrated line strengths. Species concentration was determined from the integrated line intensity and the measured temperature. The result show that the system has 2% error in wide operation frequency range and accuracy of $CO_2$ concentration was about 3%. The system was applied to measure temperature and concentration in the combustion region of a premixed $CH_4$ +air triangular flame. The measurement results of gas temperature agreed well with thermocouple results. Many considerations were taken into account to reduce optical noise, etalon effect, beam steering and base line matching problem. The evaluations results and actual combustion measurement demonstrate the practical and applicability for in-situ and real time combustion monitoring in a practical system.

  • PDF

순간흡수 분광학 측정장치 구성 및 DDI의 순간흡수율 변화 측정 (Fabrication of Transient Absorption Spectroscopic System and Measurement of Transient Absorption Changes of DDI)

  • 서정철;이민영;김동호;정홍식;박승한;김웅
    • 한국광학회지
    • /
    • 제2권4호
    • /
    • pp.209-213
    • /
    • 1991
  • 최근들어 극초단 광학펄스를 생성하고 증폭하는 기술의 발달로 인하여 시분해 레이저 분광학에 많은 영향을 끼치게 되었다. 그 중에서도 응용성이 넓은 순간흡수분광학장치를 본 연구실에서 개발하였다. 이 기술은 고출력 레이저 펄스를 이용하여 white light continuum pulse를 생성시켜 이를 조사빔으로 이용하고, pump pulse는 원래 상태의 레이저를 이용하는 것이다. 순간흡수율 변화를 여러 파장에서 측정가능하도록 photodiode array를 이용하였으며, pump와 probe pulse의 시간차이에 의한 순간흡수율 변화를 색소의 일종인 DDI를 이용하여 측정하였다.

  • PDF

관내법을 이용한 흡.차음 성능 측정방법 (A measuring technology of the absorption ratio and the transmission loss using the tube method)

  • 이장명;김동률
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.659-663
    • /
    • 1998
  • To measure the absorption ratio and the transmission loss of a material, a usage of the reverberation room has been popular. However, the reverberation room is expensive to build it and, sometimes, test procedure is not easy. Therefore, to get the data of absorption ratio, several possible technologies has been proposed using the tube. Among these technologies, with the analysis of the spectral density, a convenient method has been introduced to measure both the absorption ratio and transmission loss. The measured data has been compared with the results of the measurement at the reverberation room.

  • PDF

셀프레벨링 모르타르용 Primer 성상에 따른 특성평가에 관한 실험적 연구 (An Experimental Study on the Characteristics of Evaluation with Feature of Self Levelling Primer)

  • 강동균;김경덕;김정환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.505-508
    • /
    • 2006
  • Self-leveling mortar is walkable bottom mortar which can maintain the horizontality of self fluid and have the the quick-setting quality, the low-human-effort practicable material of high-quality bottom in construction. In accordance with more adhesive strength with bottom side and absorption control, Primer is used for purpose to prevent pin-hole occurrence by self leveling mortar application prior to construction. This study is composed measurement of absorption, adhesive strength. Used material is NP-40 as nonionic emulsifying agent, uses SA-210L as negative ion emulsifying agent, uses APS, SBS as ridical initiator. A result of test, in accordance with image of Primer, as low temperature and application frequency, indicates low absorption rate and adhesive strength, as solid powder and dryness time is increse, absorption rate and adhesive strength lowly shows figure.

  • PDF

수소 기체에 의한 Al/Pd 박막의 전기 특성 변화 (Electrical Characteristic Change of Al/Pd Film by Hydrogen Gas)

  • 조영신
    • 한국수소및신에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.386-390
    • /
    • 2005
  • Al film(135.5 nm thick) with Pd film(39.6 nm thick) on the top of it was made by thermal evaporation method. Electrical resistance change due to hydrogen absorption and desorption was measured by four point measurement method. The sample was activated by hydrogen absorption and desorption cycling at room temp. Hydrogen was introduced into the film by increasing hydrogen gas pressure step by step up to 640 torr at room temp. The resistance change ratio was decreased to 12 % with increasing hydrogen pressure in contrast to normal metal behavior. This strange tendency was not understood yet. Further study is needed to find out the mechanism of hydrogen absorption in Al in Al/Pd film.

PZT박막 적외선 감지소자의 적외선 흡수층으로 증착된 니켈 박막의 광학 및 전기적 특성 분석 (Absorptance and Electrical Properties Evaluation of Nickel Layer Deposited onto Thin Film Pyroelectric PZT IR Detector)

  • 고종수
    • 대한기계학회논문집A
    • /
    • 제28권11호
    • /
    • pp.1727-1732
    • /
    • 2004
  • A nickel layer was deposited onto the PZT thin films, serving both as a selective radiation absorption layer and as a top electrode. The absorption properties of such nickel coated multi-layered infrared detectors were studied in the visible and infrared wavelength ranges. The optimal thickness of the nickel layer on our substrate was 10nm. The maximum absorption coefficient of the deposited 10nm thick nickel layer was 0.7 at a 632nm wavelength. However, a striking asymmetric polarization hysteresis loop was observed in these PZT thin films with nickel as the top electrode. This asymmetric polarization was attributed to the difference between the dynamic pyroelectric responses in these Ni/PZT/Pt films poled either positively or negatively before the measurement. A positively poled film showed a 40% higher voltage response than a negatively poled detector.

파장변조 광흡수 분광법을 이용한 농도 계측 기법 (Species Concentration Measurement Technique Using Wavelength Modulation Absorption Spectroscopy)

  • 안재현;김용모
    • 한국분무공학회지
    • /
    • 제9권4호
    • /
    • pp.67-76
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, reasonable cost, robustness, and ease of use. In addition, diode lasers we fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develop new gas sensing system and to verify feasibility of this system. Wavelength modulation spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

전계흡수형 도파로에서 광전류를 이용한 전계에 따른 흡수변화의 측정 (Measurement of field-induced absorption changes in an electroabsorption waveguide using photocurrent)

  • 강병권;박승한;최중길
    • 한국광학회지
    • /
    • 제10권3호
    • /
    • pp.254-258
    • /
    • 1999
  • 전계흡수형 반도체 광도파로에서 흡수된 빛에 의해 발생된 광전류는 전파되는 파장에 따라 Fabry-Perot 모드의 간섭패턴을 나타냄을 보이고, 이로부터 인가전압에 따른 흡수계수의 변화를 측정할 수 있는 방법을 제시하였다. 광전류 신호는 파장에 따라 공명 반공명을 반복해서 나타내며 그 진폭은 흡수계수의 크기에 의존하므로 전계에 따른 흡수계수의 변화량을 측정 할 수 있었고, 1.55 $\mu\textrm{m}$ 파장에서 역전압 1.5V 인가시 bulk in GaAsP의 흡수계수 변화는 대략 157cm-1임을 알 수 있었다.

  • PDF

Measurement of excited species in discharges using Laser Absorption spectroscopy

  • Sakai, Yosuke
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.5-8
    • /
    • 2000
  • The population density of excited species in dc, rf and laser ablation plume plasmas has been measured using laser absorption spectroscopy. It was shown that, when the plasma was modulated by on and off with, the sensitivity and signal to noise (S/N) ratio became high. For example, the atomic O(3$^{5}$ S$^{o}$ $_2$) Population density, No* in $O_2$/He mixtures was obtained by the highest S/N ratio at a frequency of 2.7kHz. In a 20Torr room air, the lowest No* level to be detectable was shown to be an order of 10$^{7}$ cm$^{-3}$ . The population densities of resonance Ar(1S$_2$) and Xe(1S$_4$) levels were also measured in barrier discharges and laser ablation plasmas.

  • PDF

SEA 기법을 이용한 저중량 대시판넬 흡,차음재 성능에 대한 연구 (Acoustic Study of light weight insulation system on Dash using SEA technique)

  • 임효석;박광서;김영호;김인동
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.51-55
    • /
    • 2007
  • In this paper Statistical Energy Analysis has been considered to predict high frequency air borne interior noise. Dash panel Insulation is major part to reduce engine excitation noise. Transmission loss and absorption coefficient are considered to predict dash insulation performance. Transmission lose is derived from coupling loss factor and absorption coefficient is derived from internal damping loss factor. Material Biot properties were used to calculate each loss factors. Insulation geometry thickness distribution was hard to measure, so FeGate software was used to calculate thickness map from CAD drawing. Each predicted transmission losses between conventional insulation and light weight insulation were compared with SEA. Transmission loss measurement was performed to validate each prediction result, and it showed good correlation between prediction and measurement. Finally interior noise prediction was performed and result showed light weight insulation system can reduce 40% weight to keep similar performance with conventional insulation system, even though light weigh insulation system has lower sound transmission loss and higher absorption coefficient than conventional system.

  • PDF