• Title/Summary/Keyword: Absorption Heat Pump

Search Result 105, Processing Time 0.025 seconds

Comparison Study of Air-conditioning Systems using LCC Analysis (LCC를 이용한 공조 방식별 비교 연구)

  • Kim, Joung-Kuk;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.3
    • /
    • pp.12-18
    • /
    • 2012
  • The purpose of this study is to make an economic analysis(Life cycle cost) of selecting optimal air conditioning system for a research building which is 8 stories with a total floor area of $32,010m^2$. Energy consumptions of three proposed air-conditioning systems(Alt-1,2,3) that reflect the government green-growth policy are calculated and compared. The results show that life cycle cost of Alt-3(Ventilation DX AHU+EHP) is less than Alt-1(EHP+ventilation DX AHU) by 5.1%, and Alt-2(Absorption chiller/heater+EHP) by 34.3%. Annual energy consumption of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 37.4%. Annual $CO_2$ emission of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 0.2%.

Measurement and Analysis on the Physical Properties of Multi Lithium Salts Solution in Absorption Heat-Pumps (흡수식냉난방기용 다성분 리튬염 작동매체의 증기압 및 용해도 측정)

  • Ju, Woo-Sung;Kim, Hee-Taik;Oh, Young-Sam;Baek, Young-Soon
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.82-88
    • /
    • 1998
  • In an effort to obtain high efficiency in air cooled absorption heat pump, a new working fluid has developed with the addition of $LiNO_3$ and LiCl to the conventional solution of $LiBr-H_2O$. The solubility and vapor pressure of the multicomponent salts solution developed in this work were measured and compared with the results of $LiBr-H_2O$ solution. It was observed that there exists an optimal molar ratio of the inorganic salts in terms of solubility. The molar ratio of LiBr, $LiNO_3$ and LiCl was found to be about 5:1 in the $LiBr-LiNO_3$ mixture, and in the case of $LiBr-LiNO_3-LiCl$ mixture, the molar ratio of LiBr, $LiNO_3$ and LiCl was found to be around 5:1:2. The vapor pressure of the multicomponent salts solution of the optimal molar ratio was increased with adding $LiNO_3$, while decreased with adding LiCl.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 (공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.

Study on The Supplying effect of Gas Air Conditioning Systems (가스냉방 보급효과에 대한 연구)

  • Han, J.O.;Chae, J.M.;Choi, K.S.;Hong, S.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.19-25
    • /
    • 2011
  • Generally, the generation methods of cooling energy are electric air conditioning (EAC) and gas air conditioning (GAC). The EAC system is caused by increasing peak power during summer. Because the electric energy has a characteristic of non-storage, the peak electric load has been issued social problem annually whether the facility to supply is enough or not. Another way to supply cooling energy, GAC system is worked by gas energy. The absorption chiller and gas engine heat pump have been commercialized for cooling. However, the total capacity of GAC is much less than EAC and it almost depends on EAC for small market. This paper described the status of cooling energy consumption in domestic and expected the cooling energy to be consumed by electric and gas energy up to 2024 year. And also the benefit of GAC was analyzed with the case of its expansion and it was aimed to give background to fit the GAC policy.

Noncondensable gas's influence in waster vapor absorption accompanying interfacial disturbance into aqueous solution of LiBr

  • Dong-Ho RIE;Keun-Oh Lee
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.2
    • /
    • pp.63-70
    • /
    • 1992
  • The aim of this research is to obtain a basic quantitative understanding of the effect of a noncondensable gas on the absorption of water vapor by a $H_2O$ / LiBr combination with n-octanol as the surfactant. Nonflowing aqueous solutions of LiBr (40,45,50 mass%) were exposed to saturated water vapor following the addition of an n-octanol sufactant (0.01 and 0.6 mass%). A small amount of a noncondensable gas (air) was allowed into the absorber (0.03 volume%) and its effect was analyzed by measuring the amount of water vapor absorbed. This study will aid to predict the performance of heat pump and safety operating condition when the noncondensable gas is not allowed in the absorber The results indicate that, in the presence of small amounts of a noncondensable gas, vapor absorption enhancement ratios are less than half o( those obtained under the same experimental conditions when a noncondensable gas is not present (1). The presence of a noncondensable gas causes the partial vapor pressure of air to increase at the vapor / liquid interface, which results in an instability of vapor absorption rate nd. hence, in an inhibition of interfacial disturbance.

  • PDF