• 제목/요약/키워드: Absorbent

검색결과 486건 처리시간 0.026초

소규모 오수처리 시스템에서의 제올라이트에 의한 질소 제거 (Nitrogen Removal using Zeolite at On-site Wastewater Treatment System)

  • 방천희;권순국
    • 한국농공학회지
    • /
    • 제44권2호
    • /
    • pp.161-173
    • /
    • 2002
  • Recently, absorbent biofilters, which are inexpensive and easy to manacle, have been supplied to the rural areas, but have limitations in removing the nutrients effectively. Accordingly, as an alternative plan. natural zeolites were arranged in front or at the rear of the absorbent biofilters, and their removal efficiency for nitrogen and, ultimately, their applicability to the on-site wastewater treatment system were studied. Furthermore, the same experiments were carried out on artificial zeolites, made from coal ashes at National Honam Agricultural Experiment Station, to compare natural zeolites with artificial ones. Treated wastewater through the Absorbent Biofilter showed 22.6% nitrogen removal efficiency, while 64.6% was attained when natural Zeolites were placed in front of the absorbent biofilters (Zeolite-Aerobic process). As an addition, phosphorus was also efficiently removed. On the other hand, Aerobic-Zeolite process, which arranged natural zeolites at the rear of the biofilters, did not have significantly higher nitrogen removal as compared to the treatment using only the absorbent biofilters. Furthermore, upon regeneration of the natural zeolite, the ion exchange rate was fecund to increase over 10% as compared to before regeneration. Our results show that natural zeolites, applied to the on-site wastewater treatment system through the Zeolite-Aerobic process, not only increase the removal efficiency of nutrients, but, by choosing the appropriate regeneration time, can also be cast-effective. Artificial zeolites, on the other hand, though more efficient in removing nutrients, cannot be regenerated and, therefore, are not cost-effective.

흡음 석고보드 천장재에 의한 저주파 중량 바닥충격음의 저감 효과 (Effects of sound absorbent gypsum board in the ceiling on low-frequency heavyweight floor impact sound)

  • 송한솔;류종관
    • 한국음향학회지
    • /
    • 제37권5호
    • /
    • pp.323-330
    • /
    • 2018
  • 본 연구에서는 흡음 석고보드 천장재에 의한 바닥충격음 저감 효과를 조사하기 위해 잔향실에서의 흡음률 측정과 바닥충격음 성능평가 시험동에서의 바닥충격음 성능평가를 실시하였다. 먼저, 흡음률 측정은 흡음 석고보드, 흡음석고보드+글라스울, 흡음 석고보드 이중 천장재(흡음 석고보드+글라스울+흡음 석고보드)를 대상으로 실시하였다. 측정결과, 흡음 석고보드의 경우 200 Hz과 630 Hz 대역에서 약 0.1~0.5의 흡음률을 나타냈으며, 글라스울을 추가하였을 때 전체 측정 주파수대역(50 Hz ~ 630 Hz)에서 흡음률이 상승하였다. 흡음 석고보드를 추가 설치하였을 때 250 Hz 대역까지 흡음률이 크게 상승하였으나, 315 Hz 이상 대역에서는 흡음률이 감소하였다. 상기 3개의 흡음석고보드 및 일반 석고보드 천장재와 맨슬래브(천장 무) 대상으로 바닥충격음 차단 실험동에서 바닥충격음 차단성능 측정을 실시하였다. 측정결과, 흡음석고보드+글래스울과 흡음석고 보드 이중 천장재의 일반 석고보드 대비 중량충격음의 저감량은 단일평가지수 기준으로 3 dB ~ 4 dB인 것으로 나타났다. 맨슬래브 대비 중량충격음의 저감은 주로 125 Hz ~ 500 Hz 대역에서 발생하였으며 250 Hz 대역에서 최대의 저감량을 나타냈다.

연소 전 CO2 포집 흡수제들의 마모특성 (The Characteristics of Attrition of Absorbents for Pre-combustion CO2 Capture)

  • 류호정;이동호;문종호;박영철;조성호
    • 한국수소및신에너지학회논문집
    • /
    • 제24권5호
    • /
    • pp.428-436
    • /
    • 2013
  • Attrition characteristics of $CO_2$ absorbents for pre-combustion $CO_2$ capture were investigated to check attrition loss of those absorbents and to determine solid circulation direction and the better $CO_2$ absorbent. The cumulative attrition losses of two absorbents increased with increasing time. However, attrition loss under a humidified condition was lower than that under a non-humidified condition case. Between two absorbents, attrition loss of PKM1-SU absorbent was higher than that of P4-600 absorbent. The average particle sizes of the attrited particles were less than $2.5{\mu}m$ for two absorbents under a non-humidified condition case, and therefore, we could conclude that the main mechanism of attrition for two absorbents is not fragmentation but abrasion. Based on the results from the test for the effect of humidity on the attrition loss, we selected solid circulation direction from SEWGS reactor to regeneration reactor because the SEWGS reactor contains more water vapor than regeneration reactor. Attrition loss and make-up rate of two absorbents were compared based on the results from $CO_2$ sorption capacity tests and attrition tests. Required make-up rate of P4-600 absorbent was lower than that of PKM1-SU absorbent. However, more detail investigation on the optimum regeneration temperature, manufacturing cost, solid circulation rate, regeneration rate, and long-term sorption capacity should be considered to select the best $CO_2$ absorbent.

마직물 및 마혼방직물의 온열특성에 대한 흡습의 영향 (The Effect of Absorption Water on Thermal Properties of Pure Linen and Linen Blended Woven Fabrics)

  • 권오경;이참미;성우경
    • 한국의류산업학회지
    • /
    • 제1권2호
    • /
    • pp.160-165
    • /
    • 1999
  • The thermal properies of the pure linen fabrics available in the market and linen blended woven fabrics were measured at the moisture content of 0%, 20%, 40% and 60% using KES-F7 system (Thermo Iabo II type). The experimental properties were statistically analyzed by the rate of water absorbent. The main results were as follows; There is a positive correlation between the thermal insulation value (TIV) and thickness of pure linen fabrics and linen blended woven fabrics by water absorption. Whereas an negative correlation exists between the TIV and cover factor. There is a high positive correlation among the thermal conductivity (k), thickness and weight of pure linen fabrics and linen blended woven fabrics by water absorption. Wherase a high negative correlation exist between the k and air' permeability (Ap). There is a high positive correlation between the feeling of warmth/coldness and bulk density of pure linen and linen blended woven fabrics by water absorption. Wherase a high negative correlation exists between the feeling of warmth/coldness and porosity. There is a negative correlation between TIV and $q_{max}$ of pure linen fabrics and linen blended woven fabrics. The higher the rate of water absorbent, the lower the TIV. This means that TIV decreases by water absorption. As for the thermal property by rate of water absorbent $q_{max}$ and k increase by water absorption and reach max-value at 60% rate of water absorbent. The TIV decreases by water absorption and has +value at 0% rate of water absorbent, whereas it has -value with a feeling of coldness at 20%, 40%. and 60% rate of water absorbent.

  • PDF

고흡수성 수지를 이용한 흡수성 실리콘의 특성 연구 (Study on the Characteristics of the Absorbency Silicone by Super Absorbent Polymers)

  • 차국찬;송점식;이석민
    • Elastomers and Composites
    • /
    • 제47권2호
    • /
    • pp.141-147
    • /
    • 2012
  • 실리콘 수지는 소수성이 강한 고분자이기 때문에 수분을 흡수하는 기능이 전혀 없다. 하지만 고흡수성 수지(Super Absorbent Polymer)를 첨가제로 사용하면 기존의 실리콘보다 월등한 흡수성을 갖게 된다. 본 연구에서는 무정형 형태의 입자 크기가 다른 아크릴계 고흡수성 수지 3가지를 선택하여 배합비를 설정하고 2액형 타입의 의료용 실리콘 소재에 적용해서 수분을 흡수하는 기능을 갖는 새로운 실리콘 소재를 개발하였다. 고흡수성 수지의 첨가에 의한 실리콘 수지의 제조시 입자 사이즈와 함량을 달리하면서 인장, 인열, 압축, 경도에 대한 기계적 물성 변화를 알아보았으며, 시간에 따른 실리콘 수지의 흡수성을 측정하였다. 또한 전자 현미경을 통해 고흡수성 수지의 입자형태와 실리콘 수지와의 분포도를 관찰하였다.

첨단 흡수속건소재의 수분전달 특성 평가방법에 관한 연구 - 인체-의복-환경 System에서의 투습성 평가 - (Evaluation Method for the Water Transport Properties of Sweat Absorbent Fabrics - Water Vapour Transport in the of Human-Clothing-Environment System -)

  • 김은애
    • 한국의류학회지
    • /
    • 제17권2호
    • /
    • pp.329-338
    • /
    • 1993
  • The purpose of this study was to design an instrument to simulate the Human-Clothing-Environment system and evaluate the water vapour transport properties of sweat absorbent PET fabrics. The instrument was composed of sweat generating part, clothing part which can simulate clothing layers, and enviromental part. As specimens, sweat absorbent PET, regular PET, cotton, nylon and acrylics fabrics were included. For the water vapour transport(WVT), relative humidities and temperatures were measured by film type humidity sensors and thermocouples, respectively. Water vapour pressures were calculated with measured RH's and temperatures. For the liquid water transport, wickability and demand wettability were measured. Results showed that there was a difference in terms of water vapour transport mechanism depending on the fiber type ; sweat absorbent PET showed higher WVT at the transient period then equilibrated, whereas other fabrics showed lower WVT at the transient period then increased continuously. These differences are expected to affect to the difference in the comfort properties of clothings. Sweat absorbent PET showed higher demand wettability and wickability than other fabrics. Wide application of the instrument was also suggested.

  • PDF

접촉 냉감 및 흡수 냉감을 갖는 트리아세테이트 함유 기능성 냉감 직물 개발 (Development of Triacetate-containing Functional Coolness Fabrics with Cool-Touch and Cool-Absorbent)

  • 김명옥;이정순
    • 한국의류학회지
    • /
    • 제42권5호
    • /
    • pp.799-808
    • /
    • 2018
  • This study develops triacetate-containing functional fabrics with a cool-touch and cool-absorbent. For this purpose we used composite yarns made using triacetate filament and PET High absorbance quick dry filament as well as the composite fabric woven. The fineness of the yarn and structure of fabric varied the cover factor varied. The blend ratio of triacetate was differently set. When the triacetate content was the same, the cool touch of the fabric having a large cover factor and small SMD increased. The surface became smooth and the contact area became large; in addition, both the Qmax value and the cool-touch became large. In the case of similar density, the cool-touch of the fabric having a large content of triacetate increased. The cool-absorbent of the fabric containing triacetate showed a similar level of the PET High absorbance quick dry filament fabric treated with and endothermic cooling agent. It was possible to develop a functional coolness fabric with a cool-touch and a cool-absorbent when the content of triacetate and cover factor were well combined.

고흡수성(高吸水性) Polymer와 Cellulose의 흡수특성(吸水特性) 비교(比較) (The Comparison of Absorption Characteristics between High Absorbent Polymers and Cellulose)

  • 양인;안원영
    • Journal of the Korean Wood Science and Technology
    • /
    • 제18권2호
    • /
    • pp.36-48
    • /
    • 1990
  • This experiment was carried out to improve the quality of high absorbent polymer which has excellent absorptivity and water retention compared to pulp and absorption sheet, through absorption characteristics-absorptive power, water retention, absorption rate, gel strength, pH, particle size, and moisture content. - of six polymers, namely, anionic polyacrylamide, cationic polyacrylamide, polyacrylic, acid polyvinyle alcohol 500, and 1500, and a-cellulose. and to examine the possibility of substitution of amide groups for carboxyl group and/or hydroxyl group which were commercial high absorbent polymer by comparing the absorption characteristics of the polymers. Polyacrylamide has high absorptive power and water retention, but has low gel strength and poor absorption rate. The rest of polymers were similiar to ${\alpha}$-cellulose in every respect. Thus, polyacrylamides could be replaced with polyacrylic acid and polyvinyl alcohol which are presently a high absorbent polymers. In comparing the absorption characteristics and the absorptive power of the polymers-anionic polyacrylamide, cationic polyacrylamide, polyacrylic acid, polyvinyle alcohol. a-cellulose-the absorptive power was in inverse proportion to the gel strength and absorption rates, affected by the particle size and pH change.

  • PDF

공기층을 갖는 공조덕트 구조물에서 흡음재의 흡음특성에 관한 연구 (A Study on the Absorption Characteristics of Absorbents in Duct System with the Air Cavity)

  • 김찬묵;김도연;방극호
    • 소음진동
    • /
    • 제10권5호
    • /
    • pp.892-897
    • /
    • 2000
  • In this paper, experimental methods to find acoustic characteristics of acoustically treated air-conditioning duct system are proposed. Existing methods to analyze acoustic properties of duct with absorbent material have dilemma which has to assume the wave in duct to be a plane wave. Under this assumption. applicable frequency limitation makes accurate analysis of practical air-conditioning system impossible. In order to analyze the properties of in-lined treated absorbent with high degree of accuracy, in this experiments the range of exciting frequency of sound source is broadband, which means that source speaker excited higher mode of in-duct sound field. Also, to define the relations of air cavity to the acoustic characteristics, acoustic experiments on ducts with air cavity of different depth are operated. In conclusion, air-cavity makes the absorbing ability of duct improved in low frequency range. Due to the interactions between the air cavity depth and the depth of absorbents, according to depth of cavity, the magnitude of absorption coefficients vs frequencies in specific range is changed. In lower frequency range, the absorption of sound energy by air cavity is more dominant than by absorbent itself, in higher range, the inversion is true.

  • PDF

Curdlan을 이용한 기름 흡착제의 개발에 관한 연구 (Development of Oil-Absorbent Using by Curdlan)

  • 이창문;이기영;최춘순;이인영
    • KSBB Journal
    • /
    • 제16권2호
    • /
    • pp.216-219
    • /
    • 2001
  • Experimental studies were carried out to develop oil-absorbent using curdlan solution or gel. Curdlan sponge was prepared by freeze drying. Surface of curdlan sponge was observed with Scanning electron microscopy(SEM). Curdlan sponge absorbed more than 9 times oil and curdlan was recovered by gellation. Curdlan solution gelled at higher temperature than 50$^{\circ}C$ and dissolved at pH 11.0 and viscosity of curdlan solution increased at 40∼50$^{\circ}C$.

  • PDF