Diagnostic Technique for Cast Resin Molded Transformer Windings Using Active Thermography

  • Lim Young-Bae;Jung Jong-Wook;Jung Jin-Soo;Cho Seong-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.376-380
    • /
    • 2006
  • Temperature distribution measured to estimate the condition of an electrical apparatus is an absolute reference for the apparatus conditions and the difference between the reference temperature and the current temperature. Because of passive thermography, without the external thermal stimulation, the difference in surface temperature between the region of interest and back ground shows that the results can apply only to the estimation or the monitoring for the condition of loose terminal and the overload pertaining to the rise in temperature. However, a thermal diffusion in the active thermography is differently generated by the structure and condition of the surface and subsurface. This paper presents a nondestructive test using this behavior and deals with the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

The Effects of Micro-Environmental Factors on the House Dust Mite

  • Jo, Wan-Je;Sohn, Jang Yeul
    • Architectural research
    • /
    • v.9 no.2
    • /
    • pp.37-45
    • /
    • 2007
  • The proliferation of the House Dust Mite(HDM) is affected by temperature, humidity, ventilation, etc. Measuring temperature and humidity was performed at the very location where dust samplings take place and where they live in reality together with temperature and humidity of the ambient of the room. There has been discussion over the key environment factor of HDM survival; absolute humidity or relative humidity. It seems that relative humidity is the more important determinant for the mite's survival through the analysis of previous studies. Temperature, humidity, ventilation rate and Der P1 were measured in 4 flats in London. Mite allergen was detected in every house. Levels of Der P1 varied between <100ng/g and 22,778ng/g. Flats with high relative humidity(>50%) and poor ventilation(<0.5ach) showed higher levels of mite allergen than flats with lower humidity and adequate air change rate. Questionnaire survey was conducted and the result helped to confirm the findings from monitoring of environmental factors and the dust sampling.

Thermal System Analysis for Optimization of Torch Position in The Core Making Machine. (중자조형기의 토치위치 최적화를 위한 열계해석)

  • 한근조;안성찬;심재준;한동섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.587-590
    • /
    • 2000
  • The new core making method economized on core sand requested. The new method is heating core box until it reaches reasonable temperature and then spraying core sand with core binder into core box. Inner temperature distribution have to uniform in order to form core of uniform thickness. Therefore, in this study we treat of inner temperature distribution of core box in priority. First, determine proper torch number. Next, optimize the torch position to minimize the average of absolute deviation(AVEDEV) of inner temperature. The results are as followed : 1. The torch number that makes inner temperature distribution about $300^\circ{C}$ uniformly is 25. 2. When $S_H$ and $S_V$ is 0.7, the torch position is optimized and AVEDEV is 5.85.

  • PDF

Reaction of $CO_2$ with Korean Anthracites at Temperature of $850^{\circ}C$ to $1100^{\circ}C$ (無煙炭의 反應性 (第2報) 國産無煙炭의 反應成과 溫度)

  • Tae Hee Hahn
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.4
    • /
    • pp.288-292
    • /
    • 1963
  • The rates of reaction of various Korean anthracites with carbon dioxide were measured at temperatures ranging from $850^{\circ}C$ to $1100^{\circ}C$ with coal -6, +8 sieve size and the residence time of reactant gas in the fixed coal bed 14.0 to 15.0 seconds. The primary variables studied were the coal sources and temperature. The reactivity was considerably varies with the coal sources and the general trends show that the reactivity sharply increases with increasing reaction temperature except the Yongwol coal where the increase is not so sharp, which is considered to be due to high reactivity and high-pore structure of the coal. It was also found that a straight line was produced when a logarithm of the rate constant is plotted against the reciprocal of the absolute temperature up to 1000^${\circ}C$, but above that temperature it deviates from linearity. The information obtained will be of value in the design of the coal gasifier using Korean anthracites.

  • PDF

The Electrical Property of Polymer Matrix Composites Added Carbon Powder

  • Shin, Soon-Gi
    • Korean Journal of Materials Research
    • /
    • v.25 no.12
    • /
    • pp.678-682
    • /
    • 2015
  • The electrical property of polymer matrix composites with added carbon powder is studied based on the temperature dependency of the conduction mechanism. The temperature coefficient of the resistance of the polymer matrix composites below the percolation threshold (x) changed from negative to positive at 0.20 < x < 0.21; this trend decreased with increasing of the percolation threshold. The temperature dependence of the electrical property(resistivity) of the polymer matrix composites below the percolation threshold can be explained by using a tunneling conduction model that incorporates the effect of the thermal expansion of the polymer matrix composites into the tunneling gap. The temperature coefficient of the resistance of the polymer matrix composites above the percolation threshold has a positive value; its absolute value increased with increasing volume fraction of carbon powder. By assuming that the electrical conduction through the percolating paths is a thermally activated process and by incorporating the effect of thermal expansion into the volume fraction of the carbon power, the temperature dependency of the resistivity above the percolation threshold can be well explained without violating the universal law of conductivity.

Diagnostic of Cast Resin Using Active Infrared Thermal Testing Method (능동열시험법을 이용한 몰드변압기 진단)

  • Lim, Young-Bae;Jeong, Seung-Cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.481-484
    • /
    • 2004
  • A form of measured temperature distribution to estimate condition of a electrical apparatus is a absolute reference for condition of the apparatus, time rate of transition, and difference between reference and currently temperature. Because passive thermography which has not injection of external thermal stimulation shows difference of temperature being on surface of a structure and temperature difference between the structure and back ground, the result could apply only to estimation or monitor for condition of terminal relaxation and overload related with temperature rising. However, a thermal flow in active thermography is differently generated by structure and condition of surface and subsurface. This paper presents the nondestructive testing using the properties and includes the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

  • PDF

Analysis of Decompression Control Characteristics of Pneumatic Pressure Control System Considering Heat Transfer Characteristics (열전달 특성을 고려한 공기압 압력제어계의 감압제어특성 해석)

  • Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.90-95
    • /
    • 2006
  • Pneumatic control systems have been mainly used as a high speed operating system. Therefore, state change of air in a control volume was assumed to be adiabatic change and, pneumatic control systems have been analyzed by using this assumption. Especially, when absolute value of pressure change in the control volume is small, there is a tendency to neglect effect of temperature change on pneumatic control system because temperature change owing to pressure change is small. In this study, an effect of temperature change of air on the decompression control process was analyzed by considering change of mass flow rate, and heat transfer characteristics between air in the chamber and the chamber wall. As a result, this study could confirm that a slight temperature change of the air in the pneumatic pressure control system can influence on the dynamic characteristics of pressure response, and pressure control performance.

  • PDF

A Sub-1V Nanopower CMOS Only Bandgap Voltage Reference (CMOS 소자로만 구성된 1V 이하 저전압 저전력 기준전압 발생기)

  • Park, Chang-Bum;Lim, Shin-Il
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.192-195
    • /
    • 2016
  • In this paper, we present a nanopower CMOS bandgap voltage reference working in sub-threshold region without resisters and bipolar junction transistors (BJT). Complimentary to absolute temperature (CTAT) voltage generator was realized by using two n-MOSFET pair with body bias circuit to make a sufficient amount of CTAT voltage. Proportional to absolute temperature (PTAT) voltage was generated from differential amplifier by using different aspect ratio of input MOSFET pair. The proposed circuits eliminate the use of resisters and BJTs for the operation in a sub-1V low supply voltage and for small die area. The circuits are implemented in 0.18um standard CMOS process. The simulation results show that the proposed sub-BGR generates a reference voltage of 290mV, obtaining temperature coefficient of 92 ppm/$^{\circ}C$ in -20 to $120^{\circ}C$ temperature range. The circuits consume 15.7nW at 0.63V supply.

Comparison between Gel Pad Cooling Device and Water Blanket during Target Temperature Management in Cardiac Arrest Patients

  • Jung, Yoon Sun;Kim, Kyung Su;Suh, Gil Joon;Cho, Jun-Hwi
    • Acute and Critical Care
    • /
    • v.33 no.4
    • /
    • pp.246-251
    • /
    • 2018
  • Background: Target temperature management (TTM) improves neurological outcomes for comatose survivors of out-of-hospital cardiac arrest. We compared the efficacy and safety of a gel pad cooling device (GP) and a water blanket (WB) during TTM. Methods: We performed a retrospective analysis in a single hospital, wherein we measured the time to target temperature ($<34^{\circ}C$) after initiation of cooling to evaluate the effectiveness of the cooling method. The temperature farthest from $33^{\circ}C$ was selected every hour during maintenance. Generalized estimation equation analysis was used to compare the absolute temperature differences from $33^{\circ}C$ during the maintenance period. If the selected temperature was not between $32^{\circ}C$ and $34^{\circ}C$, the hour was considered a deviation from the target. We compared the deviation rates during hypothermia maintenance to evaluate the safety of the different methods. Results: A GP was used for 23 patients among of 53 patients, and a WB was used for the remaining. There was no difference in baseline temperature at the start of cooling between the two patient groups (GP, $35.7^{\circ}C$ vs. WB, $35.6^{\circ}C$; P=0.741). The time to target temperature (134.2 minutes vs. 233.4 minutes, P=0.056) was shorter in the GP patient group. Deviation from maintenance temperature (2.0% vs. 23.7%, P<0.001) occurred significantly more frequently in the WB group. The mean absolute temperature difference from $33^{\circ}C$ during the maintenance period was $0.19^{\circ}C$ (95% confidence interval [CI], $0.17^{\circ}C$ to $0.21^{\circ}C$) in the GP group and $0.76^{\circ}C$ (95% CI, $0.71^{\circ}C$ to $0.80^{\circ}C$) in the WB group. GP significantly decreased this difference by $0.59^{\circ}C$ (95% CI, $0.44^{\circ}C$ to $0.75^{\circ}C$; P<0.001). Conclusions: The GP was superior to the WB for strict temperature control during TTM.

A CMOS-based Temperature Sensor with Subthreshold Operation for Low-voltage and Low-power On-chip Thermal Monitoring

  • Na, Jun-Seok;Shin, Woosul;Kwak, Bong-Choon;Hong, Seong-Kwan;Kwon, Oh-Kyong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • A CMOS-based temperature sensor is proposed for low-voltage and low-power on-chip thermal monitoring applications. The proposed temperature sensor converts a proportional to absolute temperature (PTAT) current to a PTAT frequency using an integrator and hysteresis comparator. In addition, it operates in the subthreshold region, allowing reduced power consumption. The proposed temperature sensor was fabricated in a standard 90 nm CMOS technology. Measurement results of the proposed temperature sensor show a temperature error of between -0.81 and $+0.94^{\circ}C$ in the temperature range of 0 to $70^{\circ}C$ after one-point calibration at $30^{\circ}C$, with a temperature coefficient of $218Hz/^{\circ}C$. Moreover, the measured energy of the proposed temperature sensor is 36 pJ per conversion, the lowest compared to prior works.