Effects of Different Averaging Operators on the Urban Turbulent Fluxes (평균 방법이 도시 난류 플럭스에 미치는 영향)

  • Kwon, Tae Heon;Park, Moon-Soo;Yi, Chaeyeon;Choi, Young Jean
    • Atmosphere
    • /
    • v.24 no.2
    • /
    • pp.197-206
    • /
    • 2014
  • The effects of different averaging operators and atmospheric stability on the turbulent fluxes are investigated using the vertical velocity, air temperature, carbon dioxide concentration, and absolute humidity data measured at 10 Hz by a 3-dimensional sonic anemometer and an open-path $CO_2/H_2O$ infrared gas analyzer installed at a height of 18.5 m on the rooftop of the Jungnang KT building located at a typical residential area in Seoul, Korea. For this purpose, 7 different averaging operators including block average, linear regression, and moving averages during 100 s, 300 s, 600 s, 900 s, and 1800 s are considered and the data quality control procedure such as physical limit check and spike removal is also applied. It is found that as the averaging interval becomes shorter, turbulent fluxes computed by the moving average become smaller and the ratios of turbulent fluxes computed by the 100 s moving average to the fluxes by the 1800 s moving average under unstable stability are smaller than those under neutral stability. The turbulent fluxes computed by the linear regression are 85~92% of those computed by the 1800 s moving average and nearly the same as those computed by 900 s moving average, implying that the adequate selection of an averaging operator and its interval will be very important to estimate more accurate turbulent fluxes at urban area.

Interannual Variability of the Water Masses Observed in the Tropical Northwestern Pacific (북서태평양 열대해역에서 관측된 수괴의 경년변동성)

  • Choi, Eunji;Jeon, Dongchull
    • Ocean and Polar Research
    • /
    • v.38 no.2
    • /
    • pp.161-169
    • /
    • 2016
  • The interannual variability of the water masses was analyzed from the CTD data measured in the tropical northwestern Pacific from 2006 to 2014. There are two typical water masses NPTW and NPIW that reveal the interannual variability in the survey area, in addition to two other water masses; the surface water mass TSW with a large seasonal variability and the deep water mass AACDW with a constant temperature-salinity characteristic at the depths deeper than 2,000 meters. In 2012 and 2014 NPTW was the most widely extended horizontally and thicker than 100 meters vertically, which was found over the entire survey area. However, NPTW was reduced and became much narrower in 2009 than in the other years. NPIW seemed to expand southwards from the north of $21^{\circ}N$ to $15^{\circ}N$ in 2008 and in 2012, which showed the salinity minimum in 2013 (< 34.15 psu). The sea surface height estimated by Absolute Dynamic Topography (ADT) approximately along $135^{\circ}E$ section showed the high peaks (> $1.45dyn{\cdot}m$) between $16^{\circ}N$ and $18^{\circ}N$ during the periods between 2007 and 2009 and between 2012 and 2013; the former peak lasted wider and longer in latitude and time (about three times) than the latter. The vertical section of the geostrophic currents in the upper 1,000 meters shows that there was a mesoscale pattern of repeated eastward and westward flows a few times in some years (2010 and 2014), which seemed to disappear in some other years (2008 and 2012); the former was closely related to the mesoscale eddies and the latter implied the pattern with the permanent currents. The persistent eastward flow between $17^{\circ}N$ and $19^{\circ}N$ seems to be related to the Subtropical Countercurrent (STCC).

Cryosurgery in the Treatment of Keloids (Cryosurgery를 이용(利用)한 Keloid의 치료(治療))

  • Jung, Young-Sik;Choi, See-Ho;Seul, Jung-Hyun;Lee, Tae-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.23-30
    • /
    • 1985
  • Keloids are abnormally healed skin wounds that develop in the subpapillary layer of the dermis. They are a lesion with wide, raised and deep scars. They exceed the original dimensions of the wound and grow mounds upon mounds of collagen in a pseudotumor fashion. Their treatment may take several forms such as surgery, intralesional injection of steroid, compression, superficial irradiation, and combination therapy. However, absolute method is nothing until now. Recently, the cryosurgery shows relatively good effect in treatment, so we tried the clinical experience with cryosurgery in the treatment of keloids. Material and methods: During the past 2 years, we treated 20 individuals of the keloids with severe itching and pain. The age ranged from 5 to 45 years old. Only 6 cases were biopsied before and after cryotherapy. The cryosurgery set we used was Toitu model CR 201 $N_2O$ gas (tip temperature is $-80^{\circ}C$) and was applied directly on the lesion about 4 to 5 minutes with slight compression. After cryosurgery in keloids, the following results were obtained: 1. It is both quick and easy method. 2. It causes little or no pain and no loss of blood. 3. Integumentary normalization is rapid. The new scar tissue is smaller, and more elastic and soft. 4. The pain, itching and paresthesia commonly associated with keloid is usually disappeared. 5. Other treatment can be used after cryosurgery. 6. Histologic picture after cryosurgery is similar with the result of steroid injection. 7. The mechanism of the cryosurgery in keloids is the result of the direct tissue destroying action and cryoimmunologic reaction.

  • PDF

Effects of Cyclic Thermal Load on the Signal Characteristics of FBG Sensors Packaged with Epoxy Adhesives (주기적인 반복 열하중이 패키징된 FBG 센서 신호 특성에 미치는 영향)

  • Kim, Heonyoung;Kang, Donghoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.4
    • /
    • pp.313-319
    • /
    • 2017
  • Fiber optics sensors that have been mainly applied to aerospace areas are now finding applicability in other areas, such as transportation, including railways. Among the sensors, the fiber Bragg grating (FBG) sensors have led to a steep increase due to their properties of absolute measurement and multiplexing capability. Generally, the FBG sensors adhere to structures and sensing modules using adhesives such as an epoxy. However, the measurement errors that occurred when the FBG sensors were used in a long-term application, where they were exposed to environmental thermal load, required calibration. For this reason, the thermal curing of adhesives needs to be investigated to enhance the reliability of the FBG sensor system. This can be done at room temperature through cyclic thermal load tests using four types of specimens. From the test results, it is confirmed that residual compressive strain occurs to the FBG sensors due to an initial cyclic thermal load. In conclusion, signals of the FBG sensors need to be stabilized for applying them to a long-term SHM.

Development of the Infrared Space Telescope, MIRIS

  • Han, Won-Yong;Lee, Dae-Hee;Park, Young-Sik;Jeong, Woong-Seob;Ree, Chang-Hee;Nam, Uk-Won;Moon, Bon-Kon;Park, Sung-Joon;Cha, Sang-Mok;Pyo, Jeong-Hyun;Park, Jang-Hyun;Ka, Nung-Hyun;Seon, Kwang-Il;Lee, Duk-Hang;Rhee, Seung-Woo;Park, Jong-Oh;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.64.1-64.1
    • /
    • 2011
  • MIRIS (Multipurpose Infra-Red Imaging System), is a small infrared space telescope which is being developed by KASI, as the main payload of Science and Technology Satellite 3 (STSAT-3). Two wideband filters (I and H) of the MIRIS enables us to study the cosmic infrared background by detecting the absolute background brightness. The narrow band filter for Paschen ${\alpha}$ emission line observation will be employed to survey the Galactic plane for the study of warm ionized medium and interstellar turbulence. The opto-mechanical design of the MIRIS is optimized to operate around 200K for the telescope, and the cryogenic temperature around 90K for the sensor in the orbit, by using passive and active cooling technique, respectively. The engineering and qualification model of the MIRIS has been fabricated and successfully passed various environmental tests, including thermal, vacuum, vibration and shock tests. The flight model was also assembled and is in the process of system optimization to be launched in 2012 by a Russian rocket. The mission operation scenario and the data reduction software is now being developed. After the successful mission of FIMS (the main payload of STSAT-1), MIRIS is the second Korean space telescope, and will be an important step towards the future of Korean space astronomy.

  • PDF

Deep Learning Forecast model for City-Gas Acceptance Using Extranoues variable (외재적 변수를 이용한 딥러닝 예측 기반의 도시가스 인수량 예측)

  • Kim, Ji-Hyun;Kim, Gee-Eun;Park, Sang-Jun;Park, Woon-Hak
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.5
    • /
    • pp.52-58
    • /
    • 2019
  • In this study, we have developed a forecasting model for city- gas acceptance. City-gas corporations have to report about city-gas sale volume next year to KOGAS. So it is a important thing to them. Factors influenced city-gas have differences corresponding to usage classification, however, in city-gas acceptence, it is hard to classificate. So we have considered tha outside temperature as factor that influence regardless of usage classification and the model development was carried out. ARIMA, one of the traditional time series analysis, and LSTM, a deep running technique, were used to construct forecasting models, and various Ensemble techniques were used to minimize the disadvantages of these two methods.Experiments and validation were conducted using data from JB Corp. from 2008 to 2018 for 11 years.The average of the error rate of the daily forecast was 0.48% for Ensemble LSTM, the average of the error rate of the monthly forecast was 2.46% for Ensemble LSTM, And the absolute value of the error rate is 5.24% for Ensemble LSTM.

Analysis of Hyperbolic Heat Conduction in a Thin Film (박막에서 쌍곡선형 열전도 방정식에 의한 열전도 해석)

  • 정우남;이용호;조창주
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.540-545
    • /
    • 1999
  • The classical Fourier heat conduction equation is invalid at temperatures near absolute zero or at very early times in highly transient heat transfer processes. In such situations, a hyperbolic equation model for heat conduction based on the modified Fourier law is introduced because the wave nature of heat propagation becomes dominant. The Fourier model and the hyperbolic model for heat conduction are analyzed by using the Green's function technique together with the integral transform. Analytical expressions for the heat flux and temperature distributions in a finite slab subjected to a periodic surface heating at one of its surfaces are presented and the results obtained from each model are compared with each other. The thermal wave implied b the hyperbolic model is shown to travel through a medium and to reflect back toward the origin at the other insulated surface. On the other hand, the heat by the Fourier model propagates at an infinite speed instantaneously after a thermal disturbance is felt throughout the medium.

  • PDF

Numerical Analysis on the Flow Characteristics in Steam Ejector

  • Shin, You-Sik;Jin, Zhen-Hua;Chun, You-Sin;Lee, Sang-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.749-754
    • /
    • 2006
  • This study performed of a water cooling system by using a steam ejector and jet condenser to drop the temperature of the water in aquafarm by about $5^{\circ}C$ from $25^{\circ}C$ or higher in this research, to replace the present water cooling system, Ive focused on a water cooling system operated by latent heat of evaporation, thus this system needs a vacuum pressure to evaporate the water in enclosed tank. The water cooling effects are dependent on the vacuum pressure in the enclosed tank, and the cooling water is generated by evaporation. As the experimental results, the absolute vacuum pressure obtained was about $5{\sim}8mmHg$ using a steam driven ejector with jet condenser in experiments. The obtained results are respectively ${\Delta}T=7^{\circ}C$, ${\Delta}T=5^{\circ}C$ and ${\Delta}T=5.5^{\circ}C$ at heat exchanger flow rate 4L/M. The obtained results are respectively ${\Delta}T=5.5^{\circ}C$, ${\Delta}T=5.5^{\circ}C$ and ${\Delta}T=5.5^{\circ}C$ at heat exchanger flow rate 4.5L/M.

  • PDF

Applicability Analysis of FAO56 Penman-Monteith Methodology for Estimating Potential Evapotranspiration in Andong Dam Watershed Using Limited Meteorological Data (제한적인 기상자료 조건에서의 잠재증발산량 추정을 위한 FAO56 Penman-Monteith 방법의 적용성 분석 - 안동댐 유역을 사례로 -)

  • Kim, Sea Jin;Kim, Moon-il;Lim, Chul-Hee;Lee, Woo-Kyun;Kim, Baek-Jo
    • Journal of Climate Change Research
    • /
    • v.8 no.2
    • /
    • pp.125-143
    • /
    • 2017
  • This study is conducted to estimate potential evapotranspiration of 10 weather observing systems in Andong Dam watershed with FAO56 Penman-Monteith (FAO56 PM) methodology using the meteorological data from 2013 to 2014. Also, assuming that there is no solar radiation data, humidity data or wind speed data, the potential evapotranspiration was estimated by FAO56 PM and the results were evaluated to discuss whether the methodology is applicable when meteorological dataset is not available. Then, the potential evapotranspiration was estimated with Hargreaves method and compared with the potential evapotranspiration estimated by FAO56 PM only with the temperature dataset. As to compare the potential evapotranspiration estimated from the complete meteorological dataset and that estimated from limited dataset, statistical analysis was performed using the Root Mean Square Error (RMSE), the Mean Bias Error (MBE), the Mean Absolute Error (MAE) and the coefficient of determination ($R^2$). Also the Inverse Distance Weighted (IDW) method was performed to conduct spatial analysis. From the result, even when the meteorological data is limited, FAO56 PM showed relatively high accuracy in calculating potential evapotranspiration by estimating the meteorological data.

Machine Learning-based Quality Control and Error Correction Using Homogeneous Temporal Data Collected by IoT Sensors (IoT센서로 수집된 균질 시간 데이터를 이용한 기계학습 기반의 품질관리 및 데이터 보정)

  • Kim, Hye-Jin;Lee, Hyeon Soo;Choi, Byung Jin;Kim, Yong-Hyuk
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.17-23
    • /
    • 2019
  • In this paper, quality control (QC) is applied to each meteorological element of weather data collected from seven IoT sensors such as temperature. In addition, we propose a method for estimating the data regarded as error by means of machine learning. The collected meteorological data was linearly interpolated based on the basic QC results, and then machine learning-based QC was performed. Support vector regression, decision table, and multilayer perceptron were used as machine learning techniques. We confirmed that the mean absolute error (MAE) of the machine learning models through the basic QC is 21% lower than that of models without basic QC. In addition, when the support vector regression model was compared with other machine learning methods, it was found that the MAE is 24% lower than that of the multilayer neural network and 58% lower than that of the decision table on average.