• 제목/요약/키워드: Abrupt

검색결과 1,256건 처리시간 0.031초

The Gas Liquid Partition Coefficients of Eleven Normal, Branched and Cyclic Alkanes in Sixty Nine Common Organic Liquids II: The Effect of Solvent Structure

  • Cheong, Won-Jo
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권8호
    • /
    • pp.1207-1210
    • /
    • 2003
  • The effect of solvent structure on the slope in the plot of ln K vs. solute carbon number was examined. It was found that the free energy of methylene group transfer from the gas phase into a solvent was always negative and that the absolute magnitude of interaction free energy between the methylene group and the solvent was always larger than the absolute magnitude of cavity formation free energy of the methylene group in the solvent. Thus, the slope in the plot of ln K vs. solute carbon number was always positive and its value decreases with increase of solvent polarity since the cavity formation energy of the CH₂ unit increases with increase of solvent polarity while the dispersive interaction energy of the CH₂ unit is virtually invariant. We also examined the effect of sequential addition of CH₂ unit to a solvent molecule upon ln K for three homologous series of solvents: n-alkanes, n-alcohols, and n-nitriles. Characteristic trends in the plots of ln K vs. solvent carbon number were observed for individual solvent groups. A decrease of ln K with solvent carbon number was observed for n-alkanes. An abrupt increase in ln K followed by levelling off was observed for n-alcohols while a final slight decrease in ln K after an abrupt increase followed by rapid levelling off was noted for n-nitriles. All of theses phenomena were found related to variation in cavity formation energy. It was clearly shown that a structural change of a polar solvent by sequential addition of CH₂ units causes an abrupt polarity decrease initially, then gradual levelling off, and finally, conversion to a virtually nonpolar solvent if enough CH₂ units are added.

동적 임계값과 컷 프레임 차를 이용한 점진적 전환 검출 기법 (Gradual scene change detection using Cut frame difference and Dynamic threshold)

  • 염성주;김우생
    • 정보처리학회논문지B
    • /
    • 제9B권3호
    • /
    • pp.293-302
    • /
    • 2002
  • 내용기반 검색을 위한 비디오 데이터 장면전환 검출에서 점진적인 전환을 검출하는 것은 갑작스런 전환을 검출하는 것에 비해 일반적으로 어려운 문제로 알려져 있다. 본 논문에서는 가변형 동적 임계값과 가장 최근에 검출된 컷 프레임과 현재 프레임간의 특징값 차이인 컷 프레임 차를 이용하여 갑작스런 전환과 점진적인 전환을 찾아내는 기법을 제안한다. 이를 위하여 본 논문에서는 점진적인 전환이 갖는 특성과 수학적 모델을 제시하고 컷 프레임 차를 이용하여 점진적인 전환을 검출할 수 있음을 보인다. 그리고 이를 바탕으로 갑작스런 전환과 점진적인 전환을 함께 검출할 수 있는 방법을 제시한다. 실세계 동영상 데이터를 대상으로 한 실험을 통해 제안하는 기법이 점진적인 전환 효과의 종류에 종속적이지 않으며 적은 연산 비용으로 쉽게 점진적인 전환 유무를 검출 할 수 있음을 보인다.

2008년부터 가습기 살균제 건강 피해 급증: 우연인가, 필연인가? (Abrupt Rise of Humidifier Disinfectant Associated Health Problems since 2008: Was it chance or inevitable?)

  • 박동욱;박소영;박주현;박지훈;홍수종;백도명
    • 한국환경보건학회지
    • /
    • 제46권2호
    • /
    • pp.128-135
    • /
    • 2020
  • Objective: The objectives of this study are to report the number of humidifier disinfectant (HD) associated health problems, including HD associated lung injury (HDLI), by year. This data was analyzed by the type of HD and HD brand. Methods: A total of 530 patients registered with the national program on HD through its third round were distributed based on the year when they developed their first health problem including HDLI (N=221). The distribution of health problems at diagnosis was clinically evaluated in order to examine the association between their lung injury and the use of HD. Results: The number of HD associated victims and HDLI patients was found to rise sharply from 2008 to 2011, with a peak in 2011. This trend was found not only for HD brands containing polyhexamethylene guanidine phosphate (PHMG), but also chloromethylisothiazolinone/methylisothiazolinone (CMIT/MIT). The number of patients who responded as developing health problems in the specific year was 35 for 2008, 51 for 2009, 108 for 2010 and 182 for 2011. Other types of HD brands and HD chemicals did not follow the trend of abrupt increase in HD associated patients since 2008. Conclusion: This study found the number of HD associated victims and HDLI patients who used HD brands containing PHMG sharply increased starting in 2008. A significant change in the process of manufacturing PHMG can be suspected with the abrupt rise in HD associated patients in specific years.

방해기류 존재시 추적자 가스법을 이용한 푸쉬풀 후드 효율 평가 (Evaluation of Capture Efficiencies of Push-Pull Hood Systems by Trace Gas Method under the Presence of Some Cross-draft)

  • 김태형;하현철;강호경
    • 한국산업보건학회지
    • /
    • 제16권3호
    • /
    • pp.290-301
    • /
    • 2006
  • A push pull hood system is frequently applied to control contaminants evaporated from an open surface tank. Efficiency of push pull hood system is affected by various parameters, such as, cross draft, vessel shapes, tank surface area, liquid temperature. A previous work assisted by flow visualization technique qualitatively showed that a strong cross draft blown from the pull hood to push slot could destroy a stable wall-jet on the surface of tank, resulting in the abrupt escape of smoke from the surface. In this study, the tracer gas method was applied to determine the effect of cross-draft on the capture efficiency qualitatively. A new concept of capture efficiency was introduced, that is, linear efficiency. This can be determined by measuring the mass of tracer gas in the duct of pull hood while the linear tracer source is in between push slot and pull hood. By traversing the linear tracer source from the push slot to the pull hood, it can be found where the contaminant is escaped from the tank. Total capture efficiency can be determined by averaging the linear efficiencies. Under the condition of cross-draft velocities of 0, 0.4, 0.75, 1.05 and 1.47m/s, total capture efficiencies were measured as 97.6, 95.4, 94.6, 92.7 and 70.5% respectively. The abrupt reduction of efficiency with cross-draft velocity of 1.47m/s was due to the destruction of tank surface wall-jet by the counter-current cross-draft. The same phenomenon was observed in the previous flow visualization study. As an alternative to overcome this abrupt efficiency drop, the 20% increase of hood flow rates was tested, resulting in 20% efficiency increase.

I-V and C-V measurements or fabricated P+/N junction mode in Antimony doped (111) Silicon

  • Jung, Won-Chae
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권2호
    • /
    • pp.10-15
    • /
    • 2002
  • In this paper, the electrical characteristics of fabricated p+-n junction diode are demonstrated and interpreted with different theoretical calculations. Dopants distribution by boron ion implantation on silicon wafer were simulated with TRIM-code and ICECaEM simulator. In order to make electrical activation of implanted carriers, thermal annealing treatments are carried out by RTP method for 1min. at $1000^{circ}C$ under inert $N_2$ gas condition. In this case, profiles of dopants distribution before and after heat treatments in the substrate are observed from computer simulations. In the I-V characteristics of fabricated diodes, an analytical description method of a new triangular junction model is demonstrated and the results with calculated triangular junction are compared with measured data and theoretical calculated results of abrupt junction. Forward voltage drop with new triangular junction model is lower than the case of abrupt junction model. In the C-V characteristics of diode, the calculated data are compared with the measured data. Another I-V characteristics of diodes are measured after proton implantation in electrical isolation method instead of conventional etching method. From the measured data, the turn-on characteristics after proton implantation is more improved than before proton implantation. Also the C-V characteristics of diode are compared with the measured data before proton implantation. From the results of measured data, reasonable deviations are showed. But the C-V characteristics of diode after proton implantation are deviated greatly from the calculated data because of leakage currents in defect regions and layer shift of depletion by proton implantation.

급격한 밝기 변화가 있는 비디오 시퀀스에서 효율적인 비디오 색인 알고리즘 (An Efficient Video Indexing Algorithm for Video Sequences with Abrupt Brightness Variation)

  • 김상현;박래홍
    • 대한전자공학회논문지SP
    • /
    • 제41권5호
    • /
    • pp.35-44
    • /
    • 2004
  • 디지털 미디어 데이터의 증가에 따라 디지털 미디어를 효과적으로 관리하고 사용하기 위하여 다양한 비디오 색인 및 비디오 시퀀스 정합 알고리즘이 제안되었다. 본 논문에서는 급격한 밝기 변화를 가지는 비디오 시퀀스에 대해서 효율적인 비디오 색인 알고리즘과 비디오 시퀀스 질의에 대한 비디오 시퀀스 정합 알고리즘을 제안한다. 급격한 밝기 변화를 고려한 비디오 색인의 정확도를 향상시키고 계산량을 줄이기 위해 제안한 알고리즘은 칼라 특성뿐만 아니라 에지 특성도 함께 사용하였으며 기존의 알고리즘에 비해 현저한 성능 향상을 보였다. 제안한 알고리즘은 먼저 칼라 히스토그램을 사용하여 후보 샷경계 지점을 추출하고 에지 정합과 밝기 보상을 이용하여 후보점들이 샷경계인지 밝기 변화인지를 결정한다 장면내의 밝기 변화가 작은 경우 에지 정합과 밝기 보상은 샷경계에서만 일어난다. 실험 결과 제안한 방법은 기존의 방법에 비해 비슷한 계산량으로 현저히 향상된 성능과 효율을 보였다.

동공 움직임, 각막 반사광 및 Kalman Filter 기반 시선 추적에 관한 연구 (A Study on Gaze Tracking Based on Pupil Movement, Corneal Specular Reflections and Kalman Filter)

  • 박강령;고유진;이의철
    • 정보처리학회논문지B
    • /
    • 제16B권3호
    • /
    • pp.203-214
    • /
    • 2009
  • 본 연구에서는 모니터, 카메라 및 눈동자 좌표계간의 복잡한 3차원 관계를 고려하지 않고, 동공의 중심 위치와 모니터의 구석에 설치된 적외선 조명에 의한 네 개의 조명 반사광 사이의 관계를 사용하여 2차원적인 변환 방법으로 사용자의 시선 위치를 파악한다. 동공중심과 조명 반사광을 정확하게 추출하고, 이를 통해 계산된 시선 위치 계산의 정확도에 영향을 줄 수 있는 오차 요소들을 보정하는 것이 본 연구의 목적이다. 이를 위하여, 동공 중심을 통해 계산된 시선위치와 실제 시선 축이 이루는 카파에러를 초기 1회의 사용자 캘리브레이션을 통해 보정하였다. 또한, 칼만 필터를 기반으로 눈의 급격한 움직임 변화에도 각막 조명 반사광을 안정적으로 추적하여 시선 위치를 정확하게 추적한다. 실험 결과, 제안한 연구방법의 시선 위치 추출 오차는 눈의 급격한 움직임 변화에 상관없이 약 1.0$^\circ$ 를 나타냈다.

Multi-Pass 구조를 가지는 Shot 경계 검출기법 (Shot Boundary Detection Algorithm using Multi-Pass Mechanism)

  • 성창우;강대성
    • 융합신호처리학회논문지
    • /
    • 제1권1호
    • /
    • pp.58-63
    • /
    • 2000
  • 본 논문에서는 MPEG으로 압축된 영상에 대해서 급격한 장면 변화에 의한 shot 경계(cut)와 점진적 장면 변화에 의한 shot 경계(dissolve)를 검출하여 비디오 shot을 분할하는 기법을 제안한다. 제안하는 shot 경계 검출 기법은 기존에 잘 검출하지 못하였던 점진적 장면 변화에 의한 shot의 경계검출을 위한 알고리즘이다. 먼저 압축영역의 기법 중 DCT DC 값을 비교하는 방법을 이용하여 급격한 장면 변화에 의한 shot 경계를 검출한다. 그리고 움직임 벡터(MV)의 비를 비교하는 방법을 사용하여 점진적 장면 변화에 의한 shot 경계의 후보지들을 얻어내고, 선택된 후보지들 중 n번째와 n+2번째 후보지 영상으로 feded image를 만들어 n+1번째 후보지의 영상과 유사도를 비교하여 점진적 장면 변화에 의한 shot 경계를 검출한다. 이와 같이 압축영역의 기법으로 급격한 장면 변화에 의한 shot 경계와 점진적 장면 변화에 의한 shot 경계 후보지를 검출해 내고, 검출된 shot 경계 후보지들에서 점진적 장면 변화에 의한 shot 경계를 검출하는 방법을 함으로서 MPEG 비디오 영상의 복원량을 최소화하여 수행 속도를 높이면서도 급격한 장면 변화에 의한 shot 경계와 점진적 장면 변화에 의한 shot 경계, 두 가지 모두를 효과적으로 검출할 수 있었다.

  • PDF

Gradual Reperfusion Lowers the Incidence of Reperfusion-Induced Ventricular Fibrillation in a Cat Model of Regional Ischemia

  • Kim, You-Ho;Na, Heung-Sik;Nam, Hyun-Jung;Hur, Gyu-Young;Lee, Seung-Whan;Park, Sung-Sook;Hong, Seung-Kil
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제3권1호
    • /
    • pp.47-52
    • /
    • 1999
  • Blood flow restoration to ischemic zone of the heart is essential to salvage of ischemic tissue. However, there is a large body of evidence documenting that the reperfusion can induce reperfusion injury like reperfusion-induced malignant arrhythmias. In the present study, employing a cat model of regional cardiac ischemia, we examined if reperfusion rendered in a gradual fashion could lower the incidence of reperfusion-induced ventricular fibrillation (VF), which usually precipitated within a few to several tens of seconds after abrupt reperfusion. The experiments were conducted with male mongrel cats (n=46, 2.5-5 kg). The animals in the control and 30 MIN groups were subjected to an episode of 20- and 30-min left anterior descending coronary artery occlusion, respectively, followed by abrupt reperfusion. The animals in 5 G and 10 G groups received gradual reperfusion over a 5- and 10-min period, respectively, following a 20-min occlusion. The proportion of animals that exhibited VF during the reperfusion phase was 11/15 in the control, 7/10 in the 30 MIN, 5/10 in the 5 G and 2/11 in the 10 G groups. The incidence of VF in the 10 G group was significantly lower than that in the control or 30 MIN group subjected to abrupt reperfusion. These results suggest that the gradual reperfusion is a useful procedure against reperfusion-induced VF.

  • PDF

High Intensity Exercise Induced a Redistribution of Pyridoxal 5-Phosphate Levels with Different Vitamin $B_6$ Status in Rats

  • Cho, Youn-Ok
    • Nutritional Sciences
    • /
    • 제3권1호
    • /
    • pp.31-35
    • /
    • 2000
  • The purpose of this study was to compare the changes in PLP concentrations induced by regular, moderate, and abrupt, high-intensity exercise in the plasma and tissues of vitamin B6 deficient and normal rats. Forty-eight rats were fed either a vitamin B6 deficient (-B6) diet or a normal (+B6) diet for 5 weeks and were subdivided into 4 groups:non-exercise(NE) group: regular, moderate-intensity exercise (RME) group; abrupt, high-intensity exercise (AIE) group; abrupt, high-intensity exercise and recuperation(IRE) group. The RME group was exercised on treadmill ($10^{\circ}$, 0.5-0.8km/h) for 2 hours just before sacrifice at the end of 5th week on the diet and the IER group was recuperated for three days on the diet after being exercised like the AIE group. Pyridoxal 5 -phosphate(PLP) levels were compared in the plasma, liver and skeletal muscle of the rats. Plasma PLP concentration tended to decrease in -B6 rats and tended to increase in +B6 rats with AIE. Plasma PLP concentration in both +B6 rats with AIE and no change in both -B6 and +B6 rats with RME. Muscle PLP concentration decreased in +B6 rats, showed no change in -B6 rats with AIE. Muscle PLP concentrations in both +B6 and -B6 rats did not change with RME. Plasma PLP, liver PLP and muscle PLP concentration of IER returned to those of NE in both +B6 and -B6 rats. These results suggest that changes in PLP concentration in plasma, liver and muscle occur with exercise and are affected by exercise intensity and vitamin B6 status. These changes may be due to interorgan redistribution of PLP.

  • PDF